Finding | |
|---|---|
| Title | Failure to Provide Adequate Design Control Measures for Verifying or Checking the Adequacy of the Ultimate Heat Sink Thermal Performance Analysis |
| Description | The inspectors identified a non-cited violation of 10 CFR Part 50, Appendix B, Criterion III because the licensee did not provide adequate design control measures for verifying or checking the adequacy of the ultimate heat sink thermal performance analysis. Specifically, the licensee did not ensure that the design calculation used to determine the required number of wet cooling tower fans needed to operate the plant under normal and design conditions utilized the correct equation. As a result, the incorrect calculation provided reasonable doubt as to the operability of the wet cooling tower fans. The licensee entered this issue into their corrective action program as CR-WF3-2012-1395. The immediate corrective actions taken to restore compliance included a preliminary analysis of the condition and actions to perform a review of the methodology, inputs, and assumptions for the ultimate heat sink thermal performance calculations. The failure to provide adequate design control measures for verifying or checking the adequacy of the ultimate heat sink thermal performance analysis is a performance deficiency. The performance deficiency is more than minor because it is associated with the design control attribute of the Mitigating System Cornerstone and affects the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the wet cooling tower fans are required to be operable for heat removal following all accidents and anticipated operational occurrences. The inspectors used the NRC Inspection Manual Chapter 0609, Attachment 4, Phase 1 - Initial Screening and Characterization of Findings, to determine the significance. The inspectors determined that the finding is of very low safety significance (Green) because it is a design deficiency confirmed not to result in a loss of operability or functionality of the ultimate heat sink. This finding has a cross-cutting aspect in the decision making component of the human performance area in that the licensee did not conduct effectiveness reviews of safety-significant decisions to verify the validity of the underlying assumptions, identify possible unintended consequences, and determine how to improve future decisions |
| Site: | Waterford |
|---|---|
| Report | IR 05000382/2012003 Section 1R15 |
| Date counted | Jun 30, 2012 (2012Q2) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.15 |
| Inspectors (proximate) | L Ricketson M Davis D Allen J Laughlin R Azua D Overland N Greene |
| CCA | H.14, Conservative Bias |
| INPO aspect | DM.2 |
| ' | |