Finding | |
---|---|
Title | Failure to Maintain Design Basis Information |
Description | The inspectors identified a noncited violation of 10 CFR Part 50, Appendix B, Criterion III, \\\"Design Control\\\" in that the licensee failed to translate design basis information into procedures for the turbine-driven auxiliary feedwater pump steam admission valves. Specifically, the licensee did not translate into procedures the design requirements to manually close and gag the valves within 30 minutes in response to high energy line breaks, a fire in the auxiliary feedwater pump room, or a steam generator tube rupture event. This issue was entered into the licensee\\\'s corrective action program as Nuclear Notification 200887620. Immediate actions included posting a leveraging device for operators to use should it be necessary, training operators, and scheduling lubrication of the valves. The finding is more than minor because it impacted the Mitigating Systems Cornerstones and its objective to ensure the availability and reliability of equipment that responds to initiating events. The analyst screened the issue to more than one cornerstone due to its effect on early release (steam generator tube rupture), fire protection, and mitigating systems (high energy line break). The analyst performed a Phase 3 analysis that considered the effects of a high energy line break in the pump room, a steam generator tube rupture, and fires in the pump room and auxiliary feedwater pipe tunnel. The analyst determined that the combined significance of these scenarios was a delta- core damage frequency of 5.E-9/yr and a delta- large early release frequency of 1.6E-9/yr. Therefore, the violation was determined to be of very low safety significance (Green). The inspectors determined that cause of the finding has a crosscutting aspect in the area of problem identification and resolution associated with the corrective action program. Specifically, the licensee had previous opportunities to identify this problem when the valve was removed from the in-service testing program and when they evaluated relevant external operating experience. |
Site: | San Onofre ![]() |
---|---|
Report | IR 05000361/2010006 Section 4OA2 |
Date counted | Jun 30, 2010 (2010Q2) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71152 |
Inspectors (proximate) | C Long E Ruesch G Tutak G Wilson M Hay R Smith S Marquez S Matharu S Walker |
CCA | P.1, Identification |
INPO aspect | PI.1 |
' | |
Finding - San Onofre - IR 05000361/2010006 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (San Onofre) @ 2010Q2
Self-Identified List (San Onofre)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||