On December 21, 2009, Cooper Nuclear Station ( CNS) Control Room Operators started the High Pressure Coolant Injection ( HPCI) auxiliary oil pump to obtain an oil sample for the predictive maintenance oil analysis program. Following the start of the auxiliary oil pump, the HPCI governor valve did not respond as expected. The HPCI auxiliary oil pump was operated a second time and the governor valve did not operate at all. HPCI was declared inoperable at 13:37, Central Standard Time ( CST), resulting in entry into Technical Specification Limiting Condition of Operation (LCO) 3.5.1 Condition C, and LCO 3.3.3.2 Condition A.
Offsite analysis found corrosion on internals of the electro-hydraulic governor (EG-R). This bound the EG-R and prohibited positioning the HPCI governor valve. The corrosion originated from particulate introduced during filter change out activities, which induced corrosion in the EG-R internals during standby conditions. CNS replaced the EG-R, flushed the oil system, and revised procedures for HPCI filter change out activities. CNS will identify preventative maintenance and/or design changes to prohibit corrosion.
This event was determined to be reportable as a loss of safety function. Actual nuclear safety significance is minimal as no events occurred which required HPCI to be initiated. HPCI was declared operable at 16:45 CST on December 24, 2009. |
PLANT STATUS
Cooper Nuclear Station (CNS) was in Mode 1, Power Operation, at 100% power at the time of discovery.
BACKGROUND
The High Pressure Coolant Injection (HPCI) System (EllS:BJ) provides protection to the core for the case of a small break in the reactor coolant pressure boundary which does not result in rapid depressurization of the reactor vessel. The HPCI System permits the nuclear plant to be shutdown while maintaining sufficient reactor vessel water inventory until the reactor vessel is depressurized. The HPCI System continues to operate until reactor vessel pressure is below the pressure at which Low Pressure Coolant Injection (El IS:B0) operation or Core Spray System (EllS:BM) operation can be used to maintain core cooling.
HPCI consists of a steam turbine assembly (EllS:TRB) driving a multi-stage booster and main pump assembly (EllS:P) and system piping, valves, controls and instrumentation. The HPCI turbine is driven by steam from the reactor which is generated by decay and residual heat.
A control governor receives a HPCI flow signal and adjusts the turbine steam control valve so that HPCI design pump discharge flow rate is obtained. The flow signal used for automatic control of the turbine is derived from a differential pressure measurement across a flow element in the HPCI pump discharge pipeline. The governor controls the pressure applied to the hydraulic operator of the turbine control valve, which, in turn, controls the steam flow to the turbine.
Upon receipt of the actuation signal, the auxiliary oil pump starts, providing hydraulic pressure for the turbine stop valve and turbine control valve hydraulic operator. The flow signal will ramp the control governor until rated flow is achieved. As hydraulic oil pressure is developed, the turbine stop valve and the turbine control valve open simultaneously and the turbine accelerates toward the speed setting of the control governor. As HPCI flow increases, the flow signal adjusts the control governor setting so that design flow is maintained.
EVENT DESCRIPTION
On December 21, 2009, in support of obtaining an oil sample for the predictive maintenance oil analysis program, Control Room Operators started the HPCI auxiliary oil pump. Immediately following the start of the auxiliary oil pump, the Control Room Operator observed that the HPCI governor valve did not respond as expected. Expected response is for the valve to open and close due to pressurization of the oil header, and then ramp and stay open in response to the electronic demand signal. However, the Control Room Operator observed the governor valve position indication and noted that the valve opened, closed, and remained closed. The auxiliary oil pump was then operated for a second time and the governor valve did not operate at all.
Consequently, HPCI was declared inoperable at 13:37 Central Standard Time (CST), resulting in entry into Technical Specification Limiting Condition for Operation (LCO) 3.5.1 Condition C, ECCS - Operating, HPCI System inoperable; and LCO 3.3.3.2 Condition A, Alternate Shutdown System, One or more required Functions inoperable; and an 8-hour report to the Nuclear Regulatory Commission Operations Center was made (Event Notification 45584).
Troubleshooting activities were initiated and no degradation of the electronic control signal was found. However, the electro-hydraulic controller (EG-R) was not properly porting oil to allow positioning of the governor valve. The EG-R and the remote servo were replaced upon this discovery. During the troubleshooting, it was found that the HPCI oil filter north canister had the top portion of the filter voided of oil and corrosion products were found on the canister and element.
Immediate corrective actions, in addition to replacement of the EG-R and associated remote servo, were to inspect the tubing between the EG-R and associated remote servo. The condition of the tubing was found to be acceptable. The HPCI hydraulic oil filter canisters were cleaned and the disposable filters were replaced. The hydraulic oil was circulated through the oil filters for two hours to flush and clean oil in the system.
Interim actions were put in place to perform sampling of the hydraulic oil on the inlet and outlet of the filters, and inspect the filters to ensure that the oil supplied to the hydraulic controls is within acceptable levels of particulate and moisture. Interim actions also include an additional inspection of the currently installed EG-R internals to ensure that corrosion attack is no longer occurring.
Based on the actions completed during troubleshooting activities and compensatory actions put into place, Operations declared the HPCI System operable at 16:45 CST on December 24, 2009.
The EG-R was sent to an offsite laboratory for analysis. The analysis found that the EG-R hydraulic governor had corrosion attack on the internal pilot plunger and the plunger's bushing.
The buildup of the corrosion products was in a tight tolerance area and directly resulted in binding of the EG-R. Microscopic analysis of the corrosion found that it had characteristics that would require the areas of the corrosion to be exposed to environments that were void of oil.
Because corrosion induced EG-R failures had not occurred in the past, a change analysis was performed. The change analysis found an attributable change in which a March 2009 HPCI oil filter change out maintenance task resulted in the unacceptable introduction of particulate into the oil system. Corrosion was found to be initiated by transport of the particulate in the oil to the EG-R internals. As the particles were trapped, they facilitated corrosion that eventually bound the EG-R and resulted in the failure of the HPCI governor valve to stroke.
BASIS FOR REPORT
The HPCI System is a single train system. This condition is reportable in accordance with 10 CFR 50.73(a)(2)(v) as "any event or condition that could have prevented the fulfillment of the safety function of structures or systems that are needed to... (D) Mitigate the consequences of an accident." The event was reported as Event Notification Number 45584.
SAFETY SIGNIFICANCE
Industrial and personnel safety were not impacted by this event. Nuclear safety was impacted from the standpoint that the HPCI System is relied upon to mitigate a spectrum of small line break accidents as well as assist in maintaining reactor inventory during the initial stages of a station blackout. The potential for these accidents existed when the governor valve degradation was discovered. Thus, this event is significant from the standpoint of degradation of the credited HPCI System.
Actual nuclear safety significance was minimal from the standpoint that no events occurred that relied upon HPCI initiation. This is a Safety System Functional Failure.
CAUSE
During filter change out of the HPCI oil system in March of 2009, procedural guidance allowed mixing of unfiltered oil with filtered oil, and resulted in particulate being introduced into the oil that was transported to the EG-R. This particulate facilitated corrosion on the EG-R pilot plunger and associated bushing, resulted in binding of the EG-R, and subsequently caused failure of the EG-R to position the HPCI governor valve.
During standby conditions, the oil from the EG-R drains back to the sump, thus exposing the EG-R internals to periods of oil voided conditions, and allowed the corrosion attacks to escalate to the point of EG-R binding.
CORRECTIVE ACTION
To prevent recurrence of this event, CNS will identify areas susceptible to voiding and corrosion within the HPCI oil system and identify preventative maintenance and/or design changes to prohibit corrosion due to voiding. CNS has also revised procedural guidance to prevent the mixing of unfiltered and filtered oil during filter change out activities.
Additional actions include periodic visual inspection of the internals of the installed EG-R, inspection of oil piping and components in the hydraulic control flow path, periodic replacement of the EG-R, routine stroking of the HPCI governor, and engineering evaluation of the as found and as left condition of the EG-R recorded during rebuild.
PREVIOUS EVENTS
A review of CNS Licensee Event Reports (LER) from 2006 to present revealed that there was one other occurrence related to a loss of safety function due to HPCI being declared inoperable. On February 7, 2007, HPCI inverter circuit failure alarms were received intermittently indicating a loss of the inverter output. The failure was the result of an intermittent open circuit in the inverter caused by corrosion which resulted from solder flux residue remaining on copper conductors during the manufacturing process. The event was reported under LER 2007-001, dated April 5, 2007, with a supplemental report, LER 2007-001-01, submitted on May 23, 2007.
|
---|
|
|
| | Reporting criterion |
---|
05000410/LER-2009-001 | Momentary Loss of Control Power to High Pressure Core Spray, Pump Due to Degraded Fuse Block Connection | 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident | 05000266/LER-2009-001 | Component Coolina Water PumD Inoperable In Excess of Technical Specification Allowed Completion Time | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | 05000263/LER-2009-001 | Containment Overpressure Not Ensured in the Appendix R Analysis | 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition | 05000250/LER-2009-001 | Procedure Inadequacy Causes Control Room Ventilation Isolation Technical Specification Noncompliance | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | 05000237/LER-2009-001 | Common Mode Failure of Reactor Building Isolation Dampers | 10 CFR 50.73(a)(2)(v)(C), Loss of Safety Function - Release of Radioactive Material 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | 05000530/LER-2009-001 | Manual Reactor Trip Due to a Loss of Instrument Air to the Containment Building | | 05000457/LER-2009-001 | Reactor Trip on Over Temperature Delta Temperature due to a Signal Spike on One Channel With Another Channel Placed in the Tripped Condition for Surveillance Testing | 10 CFR 50.73(a)(2)(iv)(A), System Actuation | 05000413/LER-2009-001 | Both Trains of Chemical and Volume Control, Auxiliary Feedwater and Containment Spray Systems were Inoperable due to a Component Failure | 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | 05000412/LER-2009-001 | Equipment Operability for Steam Generator Tube Rupture Safety Analysis Not Met | 10 CFR 50.73(a)(2)(v)(C), Loss of Safety Function - Release of Radioactive Material 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident 10 CFR 50.73(a)(2)(vi) | 05000461/LER-2009-001 | Safety Function Lost Due to Capacitor Failure on Circuit Card | 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident | 05000382/LER-2009-001 | Waterford 3 Steam Electric Station 05000382 1 OF 3 | | 05000370/LER-2009-001 | | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | 05000346/LER-2009-001 | Containment Air Cooler Fans Inoperable Due to Misapplication of Potter and Brumfield Rotary Relays | 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | 05000336/LER-2009-001 | Reactor Trip Due to High Pressurizer Pressure | 10 CFR 50.73(a)(2)(iv)(A), System Actuation | 05000305/LER-2009-001 | | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | 05000281/LER-2009-001 | Manual Reactor Trip Initiated to Replace a Rod Control Data Logging Card | 10 CFR 50.73(a)(2)(iv)(A), System Actuation | 05000261/LER-2009-001 | Emergency Diesel Generator Inoperable in Excess of Technical Specifications Allowed Completion Time | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | 05000220/LER-2009-001 | Failure to Implement Required Technical Specification Actions Associated with Failed Surveillance Test | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | 05000389/LER-2009-001 | Unit 2 Main Feedwater Isolation Valves Stroke Time Potentially Affected by Temperature | 10 CFR 50.73(a)(2)(I)(B) | 05000321/LER-2009-001 | Pump Suction Swap for HPCI and RCIC Non-Conservative With Respect To Technical Specification Requirements | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | 05000334/LER-2009-001 | Surveillance Test Inadvertently Violates Technical Specification 3.6.1 for Containment Operability | 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | 05000369/LER-2009-001 | III Duke Energy® BRUCE H HAMILTON Vice President McGuire Nuclear Station Duke Energy Corporation MGO1VP / 12700 Hagers Ferry Road Huntersville, NC 28078 704-875-5333 704-875-4809 fax bhhamilton@duke-energy.com June 24, 2009
U.S. Nuclear Regulatory Commission
ATTENTION: Document Control Desk
Washington, D.C. 20555
Subject: Duke Energy Carolinas, LLC
McGuire Nuclear Station, Units 1 and 2
Docket Nos. 50-369, 50-370
Licensee Event Report 369/2009-01, Revision 0
Problem Investigation Process (PIP) M-09-02216
Pursuant to 10 CFR 50.73 Sections (a) (1) and (d), attached
is Licensee Event Report 369/2009-01, Revision 0, regarding
the past inoperability of the Nuclear Service Water System
"A" Trains due to potential for strainer fouling.
This report is being submitted in accordance. with 10 CFR
50.73 (a) (2) (i)- (B), an Operation Prohibited by Technical
Specifications, and 10 CFR 50.73 (a) (2) (v) (B), any Event.
or Condition That Could Have Prevented Fulfillment of the
Safety Function.
This event is considered to be of no significance with
respect to the health and safety of the public. There are
no regulatory commitments contained in this LER.
If questions arise regarding this LER, contact Rick Abbott
at 980-875-4685.
Very truly yours,
Bruce H. Hamilton
Attachment
www.duke-energy.corn m U.S. Nuclear Regulatory Commission
Date
Page 2
CC: L. A. Reyes, Regional Administrator •U.S. Nuclear Regulatory Commission, Region.II
Sam Nunn Atlanta Federal Center
•61 Forsyth Street, SW, Suite 23T85
Atlanta, GA 30303
J. H. Thompson, Jr. (Addressee Only)
Senior Project Manager (McGuire)
U.S. Nuclear Regulatory Commission
Mail Stop 0-8G9A
Washington, DC 20555
J. B. Brady
Senior Resident Inspector
U.S. Nucle'ar Regulatory Commission-
McGuire Nuclear Station
B. 0. Hall, Section Chief
Radiation Protection Section
1645 Mall Service Center.
Raleigh, NC 27699
NRC FORM 366 U.S. NUCLEAR REGULATORY COMMISSION APPROVED BY OMB: NO. 3150-0104t EXPIRES: 08/31/2010
(9-2007) Estimated burden per response to comply with this mandatory collection request: 50 hours. Repoded
lessons learned are incorporated into the licensing process and fed back to industry. Send comments
regarding burden estimate to the Records and FOIA/Privacy Service Branch (T-5 F52), U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, or by internet e-mail to infocollects@nrc.gov, and to the Desk Officer, Office of Information and Regulatory Affairs, NEOB-10202, (3150-0104), Office of Management and Budget, Washington, DC 20503. If a means used to impose an information (See reverse for required number of collection does not display a currently valid OMB control number, the NRC may not conduct or digits/characters for each block) sponsor, and a person is not required to respond to, the information collection. LICENSEE EVENT REPORT (LER) 1. FACILITY NAME 2. DOCKET NUMBER I 3. PAGE _McGuire Nuclear Station, . 0369 8 Unit 1 05000- OF 4. TITLE Nuclear Service Water System (NSWS)d
"A" Trains Past Inoperable when aligned
to the Standby Nuclear Service Water Pond due to'corrosion.
(SNSWP) | 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat | 05000456/LER-2009-001 | Steam Generator Tube Exceeding Plugging Criteria Remained In Service During Previous Cycle | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | 05000395/LER-2009-001 | Inadequate Procedure Results In EDG Not Obtaining Maximum Load Required By Technical Specification | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | 05000336/LER-2009-002 | Reactor Coolant System Pressure Boundary Leakage | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded | 05000373/LER-2009-002 | Loss of Shutdown Cooling Due to Spurious Closure of the Shutdown Cooling Suction Isolation Valve | 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat | 05000382/LER-2009-002 | Waterford 3 Steam Electric Station 05000382 10OF 4 | | 05000278/LER-2009-002 | Inoperable 'A' Wide Range Neutron Monitor Results in Condition Prohibited by Technical Specifications | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | 05000287/LER-2009-002 | Unit 3 Trip Due to Generator Phase Differential Lockout | 10 CFR 50.73(a)(2)(iv)(A), System Actuation | 05000263/LER-2009-002 | | | 05000412/LER-2009-002 | Unacceptable Indications Identified During Reactor Vessel Head Inspection | 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded | 05000354/LER-2009-002 | As Found Values for Safety Relief Valve Lift Setpoints Exceed Technical Specification Allowable | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | 05000346/LER-2009-002 | Vibration Induced Failure of Temperature Instrument Results in Operation above Licensed Power Limit | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | 05000261/LER-2009-002 | Failure to Complete Technical Specifications Required Action Within the Allowed Completion Time | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | 05000334/LER-2009-002 | Feedwater Isolation Initiates Auxiliary Feedwater System During Refueling Shutdown | 10 CFR 50.73(a)(2)(iv)(A), System Actuation 10 CFR 50.73(a)(2)(v), Loss of Safety Function | 05000254/LER-2009-002 | Quad Cities Nuclear Power Station Unit 1 05000254 1 OF 5 | 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident | 05000305/LER-2009-002 | Steam Exclusion Door Blocked Open During Maintenance Activities | 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function | 05000250/LER-2009-002 | Turkey Point Unit 3 05000250 1 of 10 | 10 CFR 50.73(a)(2)(v)(C), Loss of Safety Function - Release of Radioactive Material 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown | 05000220/LER-2009-002 | High Pressure Coolant Injection System Initiation Following a Manual Turbine Trip Due to High Turbine Bearing Vibrations | 10 CFR 50.73(a)(2)(iv)(A), System Actuation | 05000298/LER-2009-002 | Manual Scram On Low Water Level Caused By Turbine Trip From Hydraulic Fluid Leak | 10 CFR 50.73(a)(2)(iv)(A), System Actuation | 05000305/LER-2009-003 | Containment Spray Pump A Inoperable At Degraded Voltage Protection Setpoint | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | 05000395/LER-2009-003 | ..Potential Loss of Residual Heat Removal System Safety Function In Mode 4 Due To An Unanalyzed Condition0 | 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability | 05000389/LER-2009-003 | RCP 2B2 Lower Seal Cavity Line Leak | 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded | 05000323/LER-2009-003 | Containment Sump Recirculation Valve Position Interlock Failure Due to Inadequate Testing | | 05000263/LER-2009-003 | | 10 CFR 50.73(a)(2)(v), Loss of Safety Function | 05000261/LER-2009-003 | Manual Reactor Trip Due to Failure of 'A' Steam Generator Level Module | 10 CFR 50.73(a)(2)(iv)(A), System Actuation | 05000440/LER-2009-003 | Reactor Recirculation Pump Failure Results in Manual Reactor Protection System Actuation | 10 CFR 50.73(a)(2)(iv)(A), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown | 05000361/LER-2009-003 | Pressurizer Auxiliary Spray Failed Inservice Test | 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat | 05000457/LER-2009-003 | Drain Procedure for ECCS Suction Line Creates an Unanalyzed Condition Due to Inadequate Configuration Requirements | 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition | 05000237/LER-2009-003 | Emergency Diesel Generator Oil Leak | 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
|