05000298/FIN-2010007-03
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Inadequate Test Control |
| Description | The team identified four examples of a Green noncited violation of Technical Specification 5.4.1.a, which states in part that, Written procedures shall be established, implemented, and maintained, covering the procedures recommended in Regulatory Guide 1.33, Revision 2, Appendix A.9.b, for the failure to establish adequate procedures. Specifically, as of August 12, 2010, the licensee failed to establish adequate procedures involving 4160 V breaker maintenance, safety-related check valve maintenance, and the operation of residual heat removal pumps. This finding was entered into the licensees corrective action program as Condition Reports CNS- 2010- 05611, CNS-2010-05635, CNS-2010-05556, CNS-2010-05586, CNS-2010-05590, and CNS-2010-05342. The failure to establish adequate procedures for 4160 V breaker maintenance, safety-related check valve maintenance, and the operation of residual heat removal pumps was a performance deficiency. This finding was more than minor because it was associated with the procedure quality attribute of the mitigating systems cornerstone, and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of the 4160 Vac systems, core spray system and the residual heat removal system to respond to events and prevent undesirable consequences. Using the Manual Chapter 0609, Attachment 4, Phase 1 Initial Screening and Characterization of Findings, the issue screened as having very low safety significance (Green) because it was not a design or qualification deficiency and did not represent a loss of safety function. The licensee placed the 4160 V breaker procedures on administrative hold, performed an evaluation of the affected check valves which determined that they would be able to perform their required functions, and revised the procedures related to residual heat removal pump operations. This finding had a crosscutting aspect in the area of human performance resources because the licensee did not provide complete, accurate, and up-to-date design documentation to plant personnel. |
| Site: | Cooper |
|---|---|
| Report | IR 05000298/2010007 Section 1R21 |
| Date counted | Dec 31, 2010 (2010Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.21 |
| Inspectors (proximate) | T Farnholtz S Garchow M Young M Yeminy N Greca N Okonkwo |
| CCA | H.7, Documentation |
| INPO aspect | WP.3 |
| ' | |
Finding - Cooper - IR 05000298/2010007 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Cooper) @ 2010Q4
Self-Identified List (Cooper)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||