Finding | |
---|---|
Title | Failure to Adequately Monitor the Performance of the Screen Wash System |
Description | The inspectors identified that the licensee failed to correctly determine that a plant power reduction caused by a clogged screen wash system for the circulating water system was a maintenance preventable functional failure that exceeded the plant level performance criteria. As a direct consequence, the licensee failed to assess this Maintenance Rule Program function per 10 CFR 50.65(a)(1) as required by station procedures. This issue was determined to involve a noncited violation of 10 CFR 50.65(a)(2) requirements for monitoring the effectiveness of maintenance at nuclear power plants. The licensee entered this issue in their corrective action program as CR-CNS-2010-05631. This finding is more than minor because failure to monitor the effectiveness of the screen wash system function CW-F01 affects the protection against external factors attribute of the initiating events cornerstone, since this system was intended to limit the likelihood of events that upset plant stability. The inspectors determined that this performance deficiency was an additional, but separate consequence of the obstructed screen wash system. The inspectors determined that this finding occurred as a separate consequence of the licensees functional failure assessment process, and that the system performance problem was not directly attributable to this finding. Therefore, this finding cannot be processed through the significance determination process, and was determined to be green using the guidance of Appendix B to Manual Chapter 0612 and Appendix D to Inspection Procedure 71111.12. The finding has a crosscutting aspect in the area of human performance associated with decision-making because the licensee did not use conservative assumptions in the functional failure evaluation of an obstructed screen wash system H.1(b) |
Site: | Cooper ![]() |
---|---|
Report | IR 05000298/2010004 Section 1R12 |
Date counted | Sep 30, 2010 (2010Q3) |
Type: | NCV: Green |
cornerstone | Initiating Events |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.12 |
Inspectors (proximate) | G Guerra T Ross P Elkmann L Carson V Gaddy M Chambers E Ruesch B Hagar N Greene |
CCA | H.14, Conservative Bias |
INPO aspect | DM.2 |
' | |
Finding - Cooper - IR 05000298/2010004 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Cooper) @ 2010Q3
Self-Identified List (Cooper)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||