05000298/FIN-2010007-08
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | URI 05000298/2007011-08, High Pressure Coolant Pump Swap-Over from Emergency Condensate Storage Tank to Torus Vortex Calculation |
| Description | The team identified a Green noncited violation of 10 CFR Part 50, Appendix B, Criterion III, Design Control, for the failure of the licensee to verify the adequacy of design for the high pressure coolant injection system. Specifically, prior to December 2007, the licensee did not have vortex calculations for the high pressure coolant injection system during swap-over from the emergency condensate storage tank to the torus. The calculation was required to establish that the high pressure coolant injection pumps have adequate net positive suction head to operate in accordance with design. This finding was entered into the licensees corrective action program under Condition Report CNS-2010-5763. The failure to establish appropriate design controls for the safety-related high pressure coolant injection pump net positive suction head calculation was a performance deficiency. The finding was more than minor because it was associated with the design control attribute of the mitigating systems cornerstone and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of the high pressure coolant injection system to respond to events and prevent undesirable consequences. Using the Manual Chapter 0609, Attachment 4, Phase 1 Initial Screening and Characterization of Findings, the issue screened as having very low safety significance (Green) because it was not a design or qualification deficiency and did not represent a loss of safety function. The licensee performed an evaluation which determined that the system was capable of meeting its design function. This finding did not have a crosscutting aspect because the most significant contributor did not reflect current licensee performance. |
| Site: | Cooper |
|---|---|
| Report | IR 05000298/2010007 Section 4OA5 |
| Date counted | Dec 31, 2010 (2010Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | |
| Inspectors (proximate) | T Farnholtz S Garchow M Young M Yeminy N Greca N Okonkwo |
| INPO aspect | |
| ' | |
Finding - Cooper - IR 05000298/2010007 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Cooper) @ 2010Q4
Self-Identified List (Cooper)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||