| Description | Title 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures and Drawings, requires activities affecting quality shall be prescribed by instructions appropriate to the circumstances. Contrary to this on December 21, 2009 Operations found the high pressure coolant injection turbine was not operable due to inadequate work instructions to prevent the mixing of unfiltered and filtered oil. Introduction of unfiltered oil resulted in particulate in the electronic governor remote unit leading to corrosion and binding of the electronic governor remote unit rendering the high pressure coolant injection system inoperable. The licensee entered this issue in their corrective action program as CR-CNS-2009-10691. This finding is of very low safety significance as determined by a Manual Chapter 0612 significance determination process Phase 3 analysis. |