Finding | |
|---|---|
| Title | Failure to Follow Procedure Results in Repeat Equipment Failure |
| Description | A self-revealing finding was identified for the licensees failure to follow the guidance of Administrative Procedure 0.5.EVAL, Preparation of Condition Reports, Revision 21. Specifically, corrective actions to fix the Reactor Recirculation Motor Generator field breaker failure from 2009 failed to meet the measurable and reasonable criteria when the actions did not prevent a repeat failure of the same breaker and resulted in a fire in the breaker. The licensee entered this issue in their corrective action program as CR-CNS-2009-04115. The finding is more than minor because it adversely affected the protection against external factors (Fire), attribute of the initiating events cornerstone, and adversely affected the cornerstone objective to limit the likelihood of those events that upset plant stability and challenge critical safety functions during shutdown as well as power operations. Using Manual Chapter 0609, Significance Determination Process, Phase 1 Worksheet (Initial Screening and Characterization of Findings) the finding was determined to have very low safety significance since it did not contribute to the likelihood of a primary or secondary system loss-of-coolant accident, did not contribute to a loss of mitigation equipment, and did not increase the likelihood of a fire or internal/external flood. This finding has a crosscutting aspect in the corrective action program component of the problem identification and resolution area due to licensee corrective actions that failed to implement a resolution of field breaker failures. |
| Site: | Cooper |
|---|---|
| Report | IR 05000298/2010004 Section 4OA3 |
| Date counted | Sep 30, 2010 (2010Q3) |
| Type: | Finding: Green |
| cornerstone | Initiating Events |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71153 |
| Inspectors (proximate) | G Guerra T Ross P Elkmann L Carson V Gaddy M Chambers E Ruesch B Hagar N Greene |
| CCA | P.2, Evaluation |
| INPO aspect | PI.2 |
| ' | |
Finding - Cooper - IR 05000298/2010004 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Cooper) @ 2010Q3
Self-Identified List (Cooper)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||