| Title | Failure to Demonstrate the Ability to Transfer Diesel Fuel Oil Between Unit 1 Fuel Oil Tanks |
| Description | The inspectors identified a finding of very low safety significance and associated NCV of 10 CFR Part 50, Appendix B, Criterion XI, Test Control, for the failure to demonstrate the ability to transfer diesel fuel oil from any Unit 1 fuel oil storage tank to any Unit 1 emergency diesel generator or diesel driven cooling water pump day tank. Specifically, the licensee did not intentionally or periodically verify the ability to transfer fuel between the Unit 1 tanks as credited in the Technical Specification Basis and Updated Safety Analysis Report. This finding was entered into the licensees CAP to test the affected flow paths. The performance deficiency was determined to be more than minor because it was associated with the Mitigating Systems cornerstone attribute of equipment performance and affected the cornerstone objective of ensuring the availability, reliability, and capability of the Unit 1 emergency diesel generators and diesel drivel cooling water pumps to respond to initiating events to prevent undesirable consequences. Specifically, the failure to verify the fuel oil transfer capability did not ensure the minimum fuel oil volume required by Technical Specifications could be supplied to these systems to support their accident mitigating function. The finding screened as of very low safety significance (Green) because it did not result in the loss of operability or functionality. Specifically, the licensee reviewed the recent history of the affected piping system and determined the affected flow paths were successfully used in 2010 and 2011 providing reasonable assurance the flow paths were available. The inspectors did not find an applicable cross-cutting aspect, which represented the underlying cause of this performance deficiency; therefore, no cross-cutting aspect was assigned. |
| Site: | Prairie Island |
|---|---|
| Report | IR 05000282/2013007 Section 1R21 |
| Date counted | Jun 30, 2013 (2013Q2) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.21 |
| Inspectors (proximate) | C Baron R Walton A Stone B Jones A Della Grecan Feliz-Adorno I Hafeez |
| Violation of: | Technical Specification 10 CFR 50 Appendix B Criterion XI |
| INPO aspect | |
| ' | |
Finding - Prairie Island - IR 05000282/2013007 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Prairie Island) @ 2013Q2
Self-Identified List (Prairie Island)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||