05000282/FIN-2013002-02
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to Correct Condition Adverse to Quality for Valve SI-6-4 |
| Description | The inspectors identified a finding of very low safety significance and an non-cited violation of 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Actions, on December 29, 2012, due to the failure to correct a condition adverse to quality. Specifically, the licensee failed to correct safety injection (SI) accumulator check valve SI-6-4 after the valve failed surveillance testing. Corrective actions for this issue included performing an operability evaluation which determined that SI-6-4 was operable but nonconforming, scheduling the testing of SI-6-4 for the next refueling outage, and performing an extent of condition review. The inspectors determined that that this issue was more than minor because if left uncorrected the failure to correct conditions adverse to quality could become a more significant safety concern due to safety-related equipment issues being unresolved. This issue was of very low safety significance because each question provided in IMC 0609, Appendix A, Exhibit 2, Mitigating Systems Screening Questions, was answered no. The inspectors concluded that this issue was cross cutting in the Problem Identification and Resolution, Corrective Action Program area because the licensee did not thoroughly evaluate the problems with SI-6-4 to ensure that the resolution addressed the cause |
| Site: | Prairie Island |
|---|---|
| Report | IR 05000282/2013002 Section 1R22 |
| Date counted | Mar 31, 2013 (2013Q1) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.22 |
| Inspectors (proximate) | A Dunlop C Moore D Passehl J Bozga K Riemer K Stoedter M Holmberg M Learn M Phalen P Zurawski T Bilik |
| Violation of: | 10 CFR 50 Appendix B Criterion XVI |
| CCA | P.2, Evaluation |
| INPO aspect | PI.2 |
| ' | |
Finding - Prairie Island - IR 05000282/2013002 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Prairie Island) @ 2013Q1
Self-Identified List (Prairie Island)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||