Finding | |
|---|---|
| Title | Failure to Monitor SSCs as Required by 10 CFR 50.65 |
| Description | The inspectors identified a finding of very low safety significance (Green) and a violation of 10 CFR 50.65, due to the failure to demonstrate that the performance or condition of multiple SSCs was being effectively controlled through the performance of appropriate preventive maintenance. The licensee also failed to establish goals 2 Enclosure sufficient to provide reasonable assurance that two SSCs were capable of performing their intended safety function after their performance demonstrations became invalid. Specifically, more than 350 evaluations written between January 2012 and April 2013 to demonstrate whether the performance or condition of specific SSCs was being effectively controlled remained unapproved as of May 2013. In addition, the performance demonstration for one SSC was allowed to remained unvalid for approximately one year before designating the SSC as an (a)(1) system. Corrective actions for this issue included approving the previous evaluations, establishing 50.65(a)(1) action plans when required, and establishing actions to improve the maintenance rule program. This issue was determined to be more than minor because it was associated with the equipment performance attribute of the Mitigating Systems cornerstone and impacted the cornerstone objective of ensuring the availability, reliability and capability of systems that respond to initiating events to prevent undesirable consequences. The inspectors utilized IMC 0609, Significance Determination Process, Attachment 0609.04, Initial Characterization of Findings, and concluded that this findings significance was best characterized by using IMC 0609, Appendix M, Significance Determination Process Using Qualitative Criteria. Based upon the fact that none of the equipment issues discussed above rose to a level of greater than very low safety significance, the inspectors determined that this issue was best characterized as having very low safety significance (Green). The inspectors concluded that this finding was cross cutting in the Problem Identification and Resolution, Corrective Action Program area because the licensee failed to take appropriate and timely corrective actions to address the issues identified in November 2011 (P.1(d)). |
| Site: | Prairie Island |
|---|---|
| Report | IR 05000282/2013003 Section 4OA2 |
| Date counted | Jun 30, 2013 (2013Q2) |
| Type: | Violation: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | K Riemer M Phalen K Stoedter V Myers T Daunj Corujo-Sandinj Mancuso K Riemer K Stoedter L Kozak M Bielby M Ziolkowski N Feliz-Adomo P Laflamme P Zurawski T Haverkamp V Meghani |
| Violation of: | 10 CFR 50.65 |
| CCA | P.3, Resolution |
| INPO aspect | PI.3 |
| ' | |