05000282/FIN-2013002-08
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Failure to Correct Condition Adverse to Quality on the D1 EDG |
Description | The inspectors identified a finding of very low safety significance and an non-citied violation of 10 CFR Part 50, Appendix B, Criterion XVI, on August 14, 2012, due to the licensees failure to identify and correct a condition adverse to quality. Specifically, the licensee failed to identify and correct a condition of thick smoke resulting from an exhaust manifold oil leak on the D1 EDG; this condition had existed since April 13, 2012. This issue led to an unplanned shutdown of the Unit 1 reactor due to the discovery of a similar condition on the D2 EDG. Corrective actions included completing an equipment cause evaluation and replacing the EDG exhaust manifold gaskets and bolting. The inspectors determined the finding was more than minor because, if left uncorrected, the failure to promptly identify and correct conditions adverse to quality could become a more significant safety concern. Specifically, the failure to identify and correct emergency diesel generator oil leaks could lead to a fire hazard and the unavailability of safety-related equipment. A Senior Reactor Analyst determined that this finding was of very low safety significance because the overall change in core damage frequency due 4 Enclosure to this issue was 3.3E-7/yr. The inspectors determined the finding was cross-cutting in the Problem Identification and Resolution, Operating Experience area because of the licensees failure to implement and institutionalize operating experience through changes to station processes, procedures, equipment, and training programs |
Site: | Prairie Island |
---|---|
Report | IR 05000282/2013002 Section 4OA3 |
Date counted | Mar 31, 2013 (2013Q1) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71153 |
Inspectors (proximate) | A Dunlop C Moore D Passehl J Bozga K Riemer K Stoedter M Holmberg M Learn M Phalen P Zurawski T Bilik |
Violation of: | 10 CFR 50 Appendix B Criterion XVI |
CCA | P.5, Operating Experience |
INPO aspect | CL.1 |
' | |