05000272/LER-1978-075, Supplemental LER 78-075/03X-1:on 781130,while Containment Entry in Progress,Inner Door of Air Lock Elevation 130 Ft Would Not Fully Open.Caused by Failed Cam Roller on Inner Door Operating Mechanism.Cam Roller Replaced

From kanterella
(Redirected from 05000272/LER-1978-075)
Jump to navigation Jump to search
Supplemental LER 78-075/03X-1:on 781130,while Containment Entry in Progress,Inner Door of Air Lock Elevation 130 Ft Would Not Fully Open.Caused by Failed Cam Roller on Inner Door Operating Mechanism.Cam Roller Replaced
ML18081A947
Person / Time
Site: Salem 
Issue date: 01/22/1980
From: Kapple A
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML18081A946 List:
References
LER-78-075-03X, LER-78-75-3X, NUDOCS 8001280357
Download: ML18081A947 (1)


LER-1978-075, Supplemental LER 78-075/03X-1:on 781130,while Containment Entry in Progress,Inner Door of Air Lock Elevation 130 Ft Would Not Fully Open.Caused by Failed Cam Roller on Inner Door Operating Mechanism.Cam Roller Replaced
Event date:
Report date:
2721978075R00 - NRC Website

text

17*77)

LICENSEE EVENT REPORT UPDATE REPORT - Previous Report Date** 18/78 CONTROL BLOCK: I I

l I

I I.

!PLEASE PRINT OR TYPE ALL REa8o INFORMATION!

1 6

liliJ I~ Cr I s I G Is I 1 IG)I o I o I -1 o Io I o I o.1 o I - I o I o 10)1 4 I 1 I 1 I 1 I 1101 r 1 G) 7 8

9

  • LICENSEE CODE 14 IS LICENSE NUMBER 25 26 LICENSE TYPE
JO 57 CAT 58 CON'T [ffi]

. 7 8

~~~~~~ L1J© I o I s I o I o I o I 2 I 1 I 2 101 1 I 11 3 10 I 1 I B I© I o 11 I 2 I 2 I a I o I G) 60 61 OOCKET NUMBER 68 69 EVENT CATE 74 75 REPORT CATE 80 EVENT DESCRIPTION ANO PROBABLE CONSEQUENCES@

[§JI) I Du.ring normal operations* while a containment entry*was in progress, the inner door of air lock elev. 130' would not fully open.

Maintenance Department was informed and the LCO for T/S 3.6.1.3.a was implemented which requires repair within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.J The air lock was repaired, tested and returned to service within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.

This is the 13th occurrence of this type.

(LER's 77-58, 77-70, 77-73, 78-3, 78-27, 78-28,

!]JI] I 78-45, 78-56, 78-S8, 78-60, 78-66, 78-68)

'.[ill]

I 7 8 9

[]:TI]

7 8

SYSTEM CODE IS I Al@

9 10

  • [.:;\\

LER *Ro CVENT vE.... A 0

REPORT I 7 I 8 I NUMBEl'l 21 22

CAUSE

CAUSE

CODE SUBCODE COMPONENT CODE LIJ@ ~@ IPI EINI EITIRI@

11 12 13 18 SEQUENTIAL.

OCCURRENCE REPORT NO.

COOE l=:J Io I 71 s I I...---1 I o I 3 I 23 24 26 27 28 29 ACTION FUTURE EFFECT SHUTDOWN COMP.

suBcooE 12.J@

19 REPORT TYPE L2Ll 30 VALVE suBCODE L!J@

20 l=.J JI PRIME COMP.

REVISION NC.

LlJ 32 COMPONENT 80 TAKEN ACTION ON PLANT METHOD HOURS SUBMITTED FOAM :iUB.

~

ATTACHMENT NPA04 SUPPL.I EA MANUFACTURER

~@~@ L:J@

l!J@)

I 01o10 33 34 JS 36 37 I I l.EJ@

L...!J@)

40 41 42 l.1:l I c I 311 I o1@

CAUSE DESCRIPTION ANO CORRECTIVE ACTIONS @

43 44 47 OJ)) I The cause of this occurrence was a failed cam roller on the inner door operating mechanism.

The cam roller was replaced and the door closing mechanism was adjusted for positive door seal.

During the refueling outage, the. inner and outer [JJ]J I door upper hinge shaft restraint bearing supports and worn internal door parts on I

lJE]._I _1_o_o_a_n_d ___ l_3_0_'_e_l_e_v_a_t_i_* o_n __

a_i_r_l_o_c_k_s_w_e_r_e __

r_e_p_l_a_c_e_d_t_o_i_* m

.... P--.r_o_v_e_a_i_r_l_o_c_k __

o...

p_e_r_a_t_i_,o_n_. ___ _

7 8

9 FACILITY 13(;\\

STATUS

"'°POWER OTHER STATUS v::::J DE W@ I 0 14 I 6 !@I __ __.N

.... /..... A __

80 METHOD OF DISCOVERY DESCRIPTION @

DISCOVERY

~' Containment Entry 8

9 10 12 1']

ACTIVITY CONTENT

~

RELEASED OF REL.EASE AMOUNT OF ACTIVITY ~

QJI] l.!.J @ l.Ll@) I N /A 7

8 9

10 11 44 4S 46 80

.1 LOCATION OF RELEASE@

Nt:A 4S 80 PERSONNEL. EXPOSURES r::;::.,

NUMBER

~TYPE(.;;;\\ DESCRIPTION IJJI] I o I o I o 1'8W~...__ __

N_../_A _____________________

7 8

9 11 12 13 PERSONNEL. INJURIES t.:".;'\\

BO NUMBER DESCRIPTION~

II@ I QI 0 I 0 l@..__ ___

_.N.....__A _______________________ ~

1 a g 11 12 LOSS OF OR DAMAGE TO FACILITY f43' TYPE

DESCRIPTION

I::;:/

80

  • ITliJ W@

NA 1

e 91

~0-----------------=<.-.;.;'--------------------------------------------'

80 PUBLICITY t::;\\,

RC US

~

ISSUEDt.:7;\\ DESCRIPTION~

N E ONL y l..!....U.I L.zJe-....._ __,.__ ___....

N~A~-----------------' I I I I I I I I I I I I I 7

e 9

10 se 69 ea NAMEOFPREPAAER _________ A __

._...;.w~*;.._K;.._a~p~p-l~e ______ ~-

PHONE: (609) 365-7000 Salem Ext~

628