Finding | |
|---|---|
| Title | Inadequate Corrective Action to Prevent Recurrence of Silent Steam Generator Feed Pump Coast-Downs |
| Description | A Green, self-revealing FIN was identified against NC.WM-AP.ZZ-0002, Performance Improvement Process, Revision 6, because PSEG did not adequately correct and prevent recurrence of steam generator feedpump (SGFP) silent coast-down events. Consequently, on April 8, 2014, PSEG operators manually tripped the Unit 1 reactor in response to lowering level in the 13 steam generator that was caused by a coast-down of the 11 SGFP. PSEG created new overhead alarms dedicated to a loss of power to SGFP governor controls, trained licensed operators on a silent SGFP coastdown event, and created a long term corrective action to automate SGFP runbacks on loss of power to the governor controls. This issue was more than minor since it was associated with the equipment performance attribute of the Initiating Events cornerstone and adversely impacted its objective to limit the likelihood of events that upset plant stability and challenge critical safety functions. In accordance with IMC 0609, Attachment 4 and Exhibit 1 of Appendix A, the inspectors determined that this finding is of very low safety significance, or Green, because the finding did not cause both a reactor trip and the loss of mitigation equipment relied upon to transition the plant from the onset of the trip to a stable shutdown condition. The inspectors determined there was no cross-cutting aspect associated with this finding since it was not representative of current PSEG performance. Specifically, in accordance IMC 0612, the causal factors associated with this finding occurred outside the nominal three-year period of consideration and were not considered representative of present performance. |
| Site: | Salem |
|---|---|
| Report | IR 05000272/2014004 Section 4OA3 |
| Date counted | Sep 30, 2014 (2014Q3) |
| Type: | Finding: Green |
| cornerstone | Initiating Events |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71153 |
| Inspectors (proximate) | A Patel A Ziedonis E Burket G Dentel J Schoppy P Finney R Barkley |
| INPO aspect | |
| ' | |
Finding - Salem - IR 05000272/2014004 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Salem) @ 2014Q3
Self-Identified List (Salem)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||