Finding | |
---|---|
Title | Failure to Perform a 10 CFR 50.59 Evaluation for Changes to SI System Valve Back-Seating Procedures |
Description | The inspectors identified a Severity Level IV NCV, having very low safety significance, of 10 CFR 50.59, AChanges, Tests, and Experiments@, for the licensee=s failure to provide documented basis for determining that changes to procedures did not require prior NRC approval. Specifically, the licensee incorrectly concluded that a 10 CFR 50.59 screening was not required when procedures were revised to eliminate the practice of back-seating normally open gate/globe valves even though the UFSAR stated that normally open gate/globe valves in the Safety Injection (SI) system are back-seated to limit valve stem leakage. The finding was determined to be more than minor because the team could not reasonably determine that the change to the plant procedure which had removed a barrier to release radioactivity into the PAB would not have ultimately required NRC prior approval. The finding was determined to be of very low safety significance because it only represented a degradation of the radiological barrier function provided for the auxiliary building. This finding has a cross-cutting aspect in the area of Human Performance, Decision Making, because during performance of the 10 CFR 50.59 applicability determination for a procedural change, in March 2008, the licensee made an inappropriate decision by failing to require a screen or full 50.59 evaluation. (H.1.(a)). (Section 1R21.3.b.5 |
Site: | Point Beach ![]() |
---|---|
Report | IR 05000266/2008009 Section 1R21 |
Date counted | Sep 30, 2008 (2008Q3) |
Type: | TEV: Severity level IV |
cornerstone | Other |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.21 |
Inspectors (proximate) | A Stone C Edwards D Reeser J Chiloyan J Penchison M Munir Z Falevits |
CCA | H.13, Consistent Process |
INPO aspect | DM.1 |
' | |
Finding - Point Beach - IR 05000266/2008009 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Point Beach) @ 2008Q3
Self-Identified List (Point Beach)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||