Finding | |
|---|---|
| Title | Failure to Maintain RCS Within Procedurally Allowed Level During Reduced Inventory |
| Description | A finding of very low safety significance and associated NCV of TS 5.4.1, Procedures, was identified by the inspectors for the failure to implement operations procedures to remain above the 34 pipe level indications for draining the RCS while in reduced inventory. Specifically, during the second planned orange risk condition of the Unit 2 refueling outage to facilitate removal of the SG nozzle dams, operators drained the RCS below the procedurally required 22 percent level, as indicated by the most conservative reactor vessel level indication. The licensee took immediate corrective actions to address the issue and was performing a causal evaluation and developing corrective actions at the end of the assessment period. The finding was determined to be more than minor because it is associated with the Mitigating Systems Cornerstone attribute of human performance and affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences (i.e., core damage). The finding is of very low safety significance (Green) because the finding did not meet the criteria for a Phase 2 or Phase 3 Analysis, as specified in IMC 0609 Appendix G, Attachment 1, Checklist 3. The inspectors also determined that the finding has a cross-cutting aspect in the area of human performance. Specifically, the licensee failed to use conservative assumptions in decision-making and adopt a requirement to demonstrate that the proposed action was safe in order to proceed rather than a requirement to demonstrate that it is unsafe in order to disapprove the action H.1(b). (Section 1R20.2 |
| Site: | Point Beach |
|---|---|
| Report | IR 05000266/2008003 Section 1R20 |
| Date counted | Jun 30, 2008 (2008Q2) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.2 |
| Inspectors (proximate) | M Kunowski R Krsek S Ghasemian M Jones R Langstaff R Ruiz R Winter J Jandovitz T Bilik W Slawinski C Brown |
| CCA | H.14, Conservative Bias |
| INPO aspect | DM.2 |
| ' | |
Finding - Point Beach - IR 05000266/2008003 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Point Beach) @ 2008Q2
Self-Identified List (Point Beach)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||