Finding | |
|---|---|
| Title | Inadequate Quality Assurance Controls for Nitrogen Supply for the AN2 System |
| Description | The inspectors identified a finding having very-low safety significance, and an associated NCV of Title 10, Code of Federal Regulations (CFR), Part 50, Appendix B, Criterion III, Design Control, for the failure to assure the nitrogen supply for the alternate nitrogen (AN2) system was controlled as safety-related in system specifications, drawings, procedures, and instructions. Specifically, the licensee did not confirm effective quality assurance controls were in place to ensure the bottled nitrogen was acceptable to support the safety-related functions of this system. The licensee entered this finding into the Corrective Action Program (CAP), and subsequently contacted the commercial nitrogen gas supplier to confirm that the vendors quality controls provided a sufficient basis to conclude that the AN2 system was operable. The finding was determined to be more than minor because if left uncorrected, the issue had the potential to lead to a more significant safety concern. Specifically, if the commercial (e.g., non-safety) gas supply vendor quality controls were not adequate to ensure contaminants such as moisture or particulates were excluded from the nitrogen gas bottles, it could potentially disable the AN2 systems capability to support manual operation of safety relief valves during post loss-of-coolant-accident mitigation. The inspectors did not identify a cross-cutting aspect associated with this finding as it did not reflect current performance. |
| Site: | Monticello |
|---|---|
| Report | IR 05000263/2015007 Section 1R21 |
| Date counted | Sep 30, 2015 (2015Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.21 |
| Violation of: | 10 CFR 50 Appendix B Criterion III, Design Control |
| INPO aspect | |
| ' | |
Finding - Monticello - IR 05000263/2015007 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Monticello) @ 2015Q3
Self-Identified List (Monticello)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||