05000286/FIN-2015002-03
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Incomplete 50.73 Report Associated with Failures of Main Steam Safety Valves |
Description | The inspectors identified a Severity Level IV NCV of 10 CFR 50.9(a); in that, Entergy did not provide complete information in a report submitted per 10 CFR 50.73(a)(2)(i)(B). Specifically, a Licensee Event Report (LER) submitted on April 27, 2015, which reported three MSSV test failures (MS-46-2, MS-45-4, MS-47-4) that occurred on February 27, 2015, did not discuss the failure of MSSV 46-3, which also failed its TS as-found lift setting test and was declared inoperable on March 22, 2015. MSSV 46-3 was inoperable for greater than its TS allowed outage time, which is a condition prohibited by TSs, and therefore is required to be reported to the NRC. The inspectors evaluated this performance deficiency in accordance with the Traditional Enforcement process. In accordance with Section 2.2.2.d of the NRC Enforcement Policy, the inspectors determined that the performance deficiency identified with the reporting aspect of the event is a Severity Level IV violation, because it is of more than minor concern, with relatively inappreciable potential safety significance and is related to findings that were determined to be more than minor issues. Specifically, this issue is related to a more than minor corrective action finding, which is documented in Section 1R22 of this report. In accordance with IMC 0612, Appendix B, this traditional enforcement issue is not assigned a cross-cutting aspect. |
Site: | Indian Point |
---|---|
Report | IR 05000286/2015002 Section 4OA3 |
Date counted | Jun 30, 2015 (2015Q2) |
Type: | TEV: Severity level IV |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71153 |
Inspectors (proximate) | A Bolger A Burritt B Pinson G Newman J Bream J Furia J Stewart R Barkley R Montgomery S Rich T Setzer |
Violation of: | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.9 10 CFR 50.73 Technical Specification |
INPO aspect | |
' | |
Finding - Indian Point - IR 05000286/2015002 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Indian Point) @ 2015Q2
Self-Identified List (Indian Point)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||