ML15259A302

From kanterella
Revision as of 21:12, 30 June 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
2015 Duane Arnold Energy Center Initial License Examination Form ES-301-2
ML15259A302
Person / Time
Site: Duane Arnold NextEra Energy icon.png
Issue date: 08/20/2015
From:
NRC/RGN-III
To:
NextEra Energy Duane Arnold
Zoia, C D
Shared Package
ML15118A361 List:
References
Download: ML15259A302 (2)


Text

ES-301 Control Room/In

-Plant Systems Outline Form ES-301-2 Facility: Duane Arnold Energy Center Date of Examination: 4/6/15 - 4/17/15 Exam Level: RO SRO-I SRO-U Operating Test No.: _2015301_____ Control Room Systems

@ (8 for RO); (7 for SRO

-I); (2 or 3 for SRO

-U, including 1 ESF)

System / JPM Title Type Code*

Safety Function a. Start a Recirc MG Set and Recirc Pump. K/A: 202001, A4.01 IR: 3.7/3.7 BANK: #202001-04 D, L 1 b. Establish RPV Level Control Post Scram with RWCU Drain to Condenser (AP with System High Temperature and Failure to Isolate). K/A: 204000, A2.14 IR: 3.2/3.2 BANK: #204000-7. D, A 2 c. Isolate an MSIV at Power. K/A: 239001, A2.10 IR: 3.8/3.9. BANK: #239001

-03. D 3 d. Manually Inject into the RPV with Core Spray to Achieve Alternate Shutdown Cooling. K/A: 209001, A4.05 IR: 3.8/3.6 M, A 4 e. Drain Torus to Radwaste (AP must install Defeat 13). K/A: 219000, A2.12 IR: 3.0/3.1 BANK: #219000-04 D, A 5 f. Placing the Main Generator on the Grid. K/A: 262001, A4.05 IR: 3.3/3.3 BANK 262001

-05. D, L 6 g. APRM Gain Adjust. K/A: 215005, A 1.07 IR: 3.0/3.4. N 7 h. Install EOP Defeat 4 with a Group 7 Isolation. K/A: 400000, A4.01 IR: 3.1/3.0 BANK: #40000-04 D, A, P 8 In-Plant Systems

@ (3 for RO); (3 for SRO

-I); (3 or 2 for SRO

-U) i. Vent the Scram Air Header. K/A 2001001, K1.09, IR: 3.1/3.2 N, E, R 1 j. Operate RCIC from 1C208. K/A: 217000, A1.03 IR: 4.0/4.0 N, R, A 2 k. Shutdown of Regulating Transformer 1Y1A for Maintenance. K/A: 262002, A4.01 IR: 2.8/3.1 BANK: #

262002-05 D, R 6 @ All RO and SRO

-I control room (and in

-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in

-plant systems and functions may overlap those tested in the control room.

  • Type Codes Criteria for RO / SRO

-I / SRO-U (A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in

-plant (EN)gineered safety feature (L)ow-Power / Shutdown (N)ew or (M)odified from bank including 1(A)

(P)revious 2 exams (R)CA (S)imulator 4-6 / 4-6 / 2-3 - / -

ES-301 Control Room/In

-Plant Systems Outline Form ES-301-2 Facility: Duane Arnold Energy Center Date of Examination: 4/6/15 - 4/17/15 Exam Level: RO SRO-I SRO-U Operating Test No.: _2015301_____ Control Room Systems

@ (8 for RO); (7 for SRO

-I); (2 or 3 for SRO

-U, including 1 ESF)

System / JPM Title Type Code*

Safety Function a. Start a Recirc MG Set and Recirc Pump. K/A: 202001, A4.01 IR: 3.7/3.7 BANK: #202001-04 D, L 1 b. Establish RPV Level Control Post Scram with RWCU Drain to Condenser (AP with System High Temperature and Failure to Isolate). K/A: 204000, A2.14 IR: 3.2/3.2 BANK: #204000-7. D, A 2 c. n/a n/a n/a d. Manually Inject into the RPV with Core Spray to Achieve Alternate Shutdown Cooling. K/A: 209001, A4.05 IR: 3.8/3.6 M, A 4 e. Drain Torus to Radwaste (AP must install Defeat 13). K/A: 219000, A2.12 IR: 3.0/3.1 BANK: #219000

-04 D, A 5 f. Placing the Main Generator on the Grid. K/A: 262001, A4.05 IR: 3.3/3.3 BANK 262001

-05. D, L 6 g. APRM Gain Adjust. K/A: 215005, A 1.07 IR: 3.0/3.4. N 7 h. Install EOP Defeat 4 with a Group 7 Isolation. K/A: 400000, A4.01 IR: 3.1/3.0 BANK: #40000

-04 D, A, P 8 In-Plant Systems

@ (3 for RO); (3 for SRO

-I); (3 or 2 for SRO

-U) i. Vent the Scram Air Header. K/A 2001001, K1.09, IR: 3.1/3.2 N, E, R 1 j. Operate RCIC from 1C208. K/A: 217000, A1.03 IR: 4.0/4.0 N, R, A 2 k. Shutdown of Regulating Transformer 1Y1A for Maintenance. K/A: 262002, A4.01 IR: 2.8/3.1 BANK: #

262002-05 D, R 6 @ All RO and SRO

-I control room (and in

-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in

-plant systems and functions may overlap those tested in the control room.

  • Type Codes Criteria for RO / SRO

-I / SRO-U (A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in

-plant (EN)gineered safety feature (L)ow-Power / Shutdown (N)ew or (M)odified from bank including 1(A)

(P)revious 2 exams (R)CA (S)imulator 4-6 / 4-6 / 2-3 - / -