05000272/LER-1979-041-01, During Refuling Outage, Eddy Current Testing of Steam Generator Tubes 12 & 14 Performed.After Testing,One Template Plug Lost in Primary Coolant Sys.Caused by Personnel Error

From kanterella
Revision as of 06:55, 6 January 2025 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
During Refuling Outage, Eddy Current Testing of Steam Generator Tubes 12 & 14 Performed.After Testing,One Template Plug Lost in Primary Coolant Sys.Caused by Personnel Error
ML18081A649
Person / Time
Site: Salem 
Issue date: 11/10/1979
From: Kapple A
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML18081A648 List:
References
LER-79-041-01X, NUDOCS 7912030195
Download: ML18081A649 (1)


LER-1979-041, During Refuling Outage, Eddy Current Testing of Steam Generator Tubes 12 & 14 Performed.After Testing,One Template Plug Lost in Primary Coolant Sys.Caused by Personnel Error
Event date:
Report date:
2721979041R01 - NRC Website

text

.UCLEAR REGULATURV COMMISSION CONTROL BLOCK: I 10 (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION!

1 6

[ill] I N b I s I G I s I 1 l@I o I o I - I o Io I o I o I o I - I o I o 101 4 I 1 I 1 I 1 I 1 101 I I G) 7 8

9 L.ICENSEE CODE 14 15

. L.ICENSE NUMBER 25 26 L.ICENSE TYPE JO S7 CAT SS CON'T [ill]

7 B

  • ~~~~ L1J© I o I s I o I o I o I 2 I 7 I 2 IG)I o I 4 I 21 s I 7 l 9 I© I 1 11 I l I o I 7 I 60 61 DOCKET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE EVENT. DESCRIPTION ANO PROBABLE CONSEQUENCES@

910 80 I During the refueling outage, eddy current testing of No. 12 and 14 S/G tubes was

((l!J f performed.

After testing, 33 of the 34 template plugs used in the S/G were CQJ:[I I accounted for.

The remaining plug assembly must be assumed lost inside the primary

((I[) I coolant system.

A Westinghouse evaluation indicated that the plug is of insignif i-

[§:))] I cant mass and chemical anal!i"sis of plug residue showed the plug wquld haye no

((II] I detrimental effect*on system operation.

This is the first occurrence of this type.

[))))

7 B 9.

BO [ffi]

  • 7 B

SYSTEM

CAUSE

CAUSE COMP.

VAL.VE CODE CODE SUBCODE COMPONENT CODE SUBCODE SUBCOOE JCIAI@ ~@ w@ 1z1z1z1z1z1z1@ W~@

9 10

. 11 12 13 1B 19 20

  • r.::-.

L.ER!RO LVENT VEAR 0

REPORT I 7 I 9 I NUMBER 21 22 SEQUENTIAL.

OCCURRENCE REPORT REPORT NO.

CODE TYPE I I I o I 41 1 I I.....-1 I o I 1 I W

L=J 23 24 26 27 28 29 30 31 ACTION FUTURE EFFECT.

SHUTDOWN t.;::\\

ATTACHMENT NPRD-4.

PRIME COMP.

REVISION NC.

L1J 32 COMPONENT MANUFACTURER

\\

TAKEN ACTION ON PL.ANT METHOD HOURS ~ SUBMITTED FORM l>UB.

SUPPL.I ER L!LJ@UJ@.

  • l..Ll@ W I o I o I o I o I l.XJ@

llLJ@ LlJ@

33 34 35 36 37 40 41 42 43 I zl 9 I 919 I@

CAUSE DESCRIPTION ANO CORRECTIVE ACTIONS @

44 47 I The cause o.f this occurrence was personnel error in that the maintenance contractor o:IIJ !supervisor failed to establish tool and material control as reguired by the job

.J
I]J I procedure.

The supervisors have been instructed to follow written job procedures [ill] I and that no work wiJ.lbe done without written notification and/or procedures.

ITilJ

  • 7 7

8 9

FACll.ITY

'3Q\\

STATUS

'!lo POWER OTHER STATUS* \\::::I ETIJ L.QJ@ 1_9 lo Io l@l __

_.N,.../.....-A~----

8 9

10 12 13 44 ACTIVITY CONTENT

  • t:;;;\\

REL.EASED OF REL.EASE AMOUNT OF ACT1VITY ~

IIIIl UJ (§) l!J@I N /A I

7 B

9 10 11 44

'ERSONNEL. EX,OSURES Q

80 METHOOOF

~

DISCOVERY DISCOVERY DESCRIPTION.

Lfj~l,___c_l_o_s_e_o_u_t __ r_n __

sp._e_c_t_i_o_n ____. ______________ ~I E

~

~

L.OCATION OF REL.EASE

. N/A 80 NUMBER t::;\\ TYPE t.::\\ OESCRiPTION

[!lII I olol ol~L!.J~l----*--N~/-A ________________________________________ ___

7 8

9 11 12 13 PERSONNEL. INJURIES

~

80 NUMBER DESCRlflTION~

EE] I 0 I 0 I 0 l@i..;1 ____

_.:N;.:.L/...:,:A:,.._ ___________________

7 B

9 11 12 80 L.OSS OF OR DAMAGE TO FACIL.ITY 143' TYf'E

DESCRIPTION

~

~

L!.l@).___. __________ =N~A=--------------------------------------------------------~

7 8

9 10 BO ISSU~~~~CRIPTION@

NRC USE ONLY ill1] Lz.Jei... I ------------------*..-..N.._/A

_________________________ __. II I I II II II I I I 7

8 9

10 6B 69 BO NAMEOFPREPARER----------A_. __ w K_a~p~p~l_e ______ ~---

PHONE: (609)365-7000 Salen EXt.

l

~8


- -. -*-* ---- -------------~ l 2 0 8 V.... ~/_J.q __ 5