NRC Inspection Report 05000409/2020001(DNMS); 07200046/2020001 (DNMS)
ML20282A553
Person / Time
Site: La Crosse  File:Dairyland Power Cooperative icon.png
Issue date: 10/08/2020
From: Dave Hills
Division of Nuclear Materials Safety III
To: Sauger J
EnergySolutions
Edwards R
References
IR 2020001
Download: ML20282A553 (12)


Text

October 8, 2020

SUBJECT:

NRC INSPECTION REPORT NO. 05000409/2020001(DNMS); 07200046/2020001 (DNMS) - LA CROSSE BOILING WATER REACTOR

Dear Mr. Sauger:

On September 14, 2020, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at the La Crosse Boiling Water Reactor (LACBWR) in Genoa, Wisconsin. The purpose of the inspection was to determine whether the Independent Spent Fuel Storage Installation (ISFSI) and decommissioning facilities were maintained safely and in accordance with NRC requirements. The enclosed report presents the results of this inspection, which were discussed with Mr. J. Nowak of your staff on September 14, 2020.

The inspection consisted of an examination of activities at the facility as they relate to safety and compliance with the Commissions rules and regulations. Areas examined during the inspection included facility management and control, radiological safety, confirmatory surveys, and ISFSI operations and maintenance. Within these areas, the inspection consisted of a selective examination of procedures and representative records, field observations of activities in progress, and interviews with personnel.

Based on the results of this inspection, the NRC did not identify any violations.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations (CFR) 2.390, Public Inspections, Exemptions, Requests for Withholding. We will gladly discuss any questions you have concerning this inspection. If you have any questions, please contact Mr. Rhex Edwards of my staff at 630-829-9722.

Sincerely, David E. Hills, Chief Materials Control, ISFSI, and Decommissioning Branch Division of Nuclear Materials Safety Docket No. 50-409;72-046 License No. DPR-45 Enclosure:

IR 05000409/2020001 (DNMS);

07200046/2020001 cc w/encl: LaCrosseSolutions Service List