Category:TECHNICAL SPECIFICATIONS
MONTHYEARML20217F9701999-10-14014 October 1999 Proposed Tech Specs,Incorporating ARC for Axial Primary Water Stress Corrosion Cracking at Dented Tube Support Plate Intersections ML20217E4301999-10-12012 October 1999 Proposed Tech Specs,Revising Requirements for Containment Penetrations During Refueling Operations ML20211M7341999-08-30030 August 1999 Marked-up & Revised TS Pages,Providing Alternative to Requirement of Actually Measuring Response Times ML20211K1721999-08-30030 August 1999 Proposed Tech Specs,Providing Clarification to Current TS Requirements for Containment Isolation Valves ML20209B7731999-06-30030 June 1999 Proposed Tech Specs Updating Requirmements for RCS Leakage Detection & RCS Operational Leakage Specifications to Be Consistent with NUREG-1431 ML20196F2211999-06-24024 June 1999 Proposed Tech Specs Pages for Amend to Licenses DPR-77 & DPR-79,allowing Use of Fully Qualified & Tested Spare Inverter in Place of Any of Eight Required Inverters ML20196G4701999-06-24024 June 1999 Proposed Tech Specs Pages Re Amends to Licenses DPR-77 & DPR-79,revising TS to Be Consistent with Rev to ISTS Presently Submitted to NEI TSTF for Submittal as Rev to NUREG-1431 ML20196G7961999-06-22022 June 1999 Proposed Tech Specs Bases,Clarifying Proper Application of TS Requirements for Power Distribution Systems & Functions That Inverters Provide to Maintain Operability & Providing Updated Info on Cold Leg Injection Accumulators ML20195E9841999-06-0707 June 1999 Proposed Tech Specs,Increasing Max Allowed Specific Activity of Primary Coolant from 0.35 Microcuries/Gram Dose Equivalent I-131 to 1.0 Microcuries/Gram Dose Equivalent I-131 for Plant Cycle 10 (U2C10) Core ML20206E1391999-04-29029 April 1999 Proposed Tech Spec Change 99-03, Main Control Room Emergency Ventilation Sys Versus Radiation Monitors. Changes Add LCOs 3.3.3.1 & 3.7.7 to Address Inoperability of Radiation Monitoring CREVS & NUREG-1431 Recommendations ML20206E1611999-04-29029 April 1999 Proposed Tech Spec Change 99-04, Auxiliary Suction Pressure Low Surveillance Frequency Rev. Change Deletes Surveillance ML20204H4081999-03-19019 March 1999 Proposed Tech Specs,Relocating TS 3.8.3.1,3.8.3.2,3.8.3.3 & Associated Bases Associated with Electrical Equipment Protective Devices to Technical Requirements Manual ML20207D6011999-02-26026 February 1999 Proposed Tech Specs Relocating TS 3.7.6, Flood Protection Plan & Associated Bases from TS to Plant TRM ML20207D6331999-02-26026 February 1999 Proposed Tech Specs Providing for Consistency When Exiting Action Statements Associated with EDG Sets ML20206S0131999-01-15015 January 1999 Proposed Tech Specs 3.3.3.3, Seismic Instrumentation & Associated Bases,Relocated to Plant Technical Requirements Manual ML20199K6001999-01-15015 January 1999 Proposed Tech Specs Adding New Action Statement to 3.1.3.2 That Would Eliminate Need to Enter TS 3.0.3 Whenever Two or More Individual RPIs Per Bank May Be Inoperable,While Maintaining Appropriate Overall Level of Protection ML20195H6111998-11-16016 November 1998 Proposed Tech Specs Revising EDG SRs by Adding Note That Allows SR to Be Performed in Modes 1,2,3 or 4 If Associated Components Are Already OOS for Testing or Maint & Removing SR Verifying Certain Lockout Features Prevent EDG Starting ML20154H7251998-10-0808 October 1998 Proposed Tech Specs Pages,Supplementing Proposed TS Change 96-08,rev 1 to Add CRMP to Administrative Controls Section & Bases of TS ML20238F1091998-08-27027 August 1998 Proposed Tech Specs Providing for Insertion of Limited Number of Lead Test Assemblies,Beginning W/Unit 2 Operating Cycle 10 Core ML20238F3001998-08-27027 August 1998 Proposed Tech Specs Replacing 72 H AOT of TS 3.8.1.1,Action b,w/7 Day AOT Requirement for Inoperability of One EDG or One Train of EDGs ML20236G5961998-06-29029 June 1998 Proposed Tech Specs Typed Pages for TS Change 95-19, Section 6 - Administrative Controls Deletions ML20249C6371998-06-26026 June 1998 Proposed Tech Specs Lowering Specific Activity of Primary Coolant from 1.0 Uci/G Dose Equivalent I-131 to 0.35 Uci/G Dose Equivalent I-131,as Provided in GL 95-05 ML20248F0051998-05-28028 May 1998 Proposed Tech Specs for Section 6, Administrative Controls Deletions ML20217N3511998-04-30030 April 1998 Proposed Tech Specs Pages,Modifying Surveillance Requirement 4.4.3.2.1.b to Change Mode Requirement to Allow PORV Stroke Testing in Modes 3,4 & 5 W/Steam Bubble in Pressurizer Rather than Only in Mode 4 ML20203J1681998-02-25025 February 1998 Proposed Tech Specs Pages,Revising EDG Surveillance Requirements to Delete Requirement for 18-month Insp IAW Procedures Prepared in Conjunction W/Vendor Recommendations & Modify SRs Associated W/Verifying Capability of DGs ML20202J7601998-02-13013 February 1998 Proposed Tech Specs Section 3.7.9 Re Relocation of Snubber Requirements ML20202J7141998-02-13013 February 1998 Proposed Tech Specs Adding New LCO That Addresses Requirements for Main Feedwater Isolation,Regulating & Bypass Valves ML20202J6961998-02-13013 February 1998 Proposed Tech Specs Incorporating MSIV Requirements to Be Consistent W/Std TS (NUREG-1431) ML20198T4311998-01-21021 January 1998 Proposed Tech Specs Re New Position Title & Update of Description of Nuclear Organization ML20199K4571997-11-21021 November 1997 Proposed Tech Specs Adding one-time Allowance Through Operating Cycle 9 to Surveillance Requirement 4.4.3.2.1.b to Perform Stroke Testing of PORVs in Mode 5 Rather than Mode 4,as Currently Required ML20211A3191997-09-17017 September 1997 Proposed Tech Specs Re Pressure Differential Surveillance Requirements for Containment Spray Pumps ML20137T0871997-04-0909 April 1997 Proposed Tech Specs Re Elimination of Cycle 8 Limitation for SG Alternate Plugging Criteria ML20137M8581997-04-0101 April 1997 Proposed Tech Specs 2.1 Re Safety Limits & TS 3/4.2 Re Power Distribution Limits ML20137C8421997-03-19019 March 1997 Proposed Tech Specs Re Conversion from Westinghouse Electric Corp Fuel to Framatome Cogema Fuel ML20136J0381997-03-13013 March 1997 Proposed Tech Specs Section 5.6.1.2,revising Enrichment of Fuel for New Fuel Pit Storage Racks ML20134P8631997-02-14014 February 1997 Proposed Tech Specs Requesting Discretionary Enforcement for 48 Hours Which Is in Addition to 72 Hours Allowed Outage Time Provided by TS Action 3.8.1.1.b ML20134K9981997-02-0707 February 1997 Proposed Tech Specs Revising TS Change Request 96-01, Conversion from W Electric Corp Fuel to Framatome Cogema Fuel (MARK-BW-17), to Ensure That Core Analysis Computer Code Output Actions Are Consistent W/Hot Channel Factor SRs ML20134L9261996-11-0808 November 1996 Proposed Tech Specs Re Placing of Channel in Trip for Reactor Trip & Engineered Safety Feature Instrumentation Sys Solely to Perform Testing as Not Requiring Channel to Be Declared Inoperable ML20129D2661996-10-18018 October 1996 Proposed Tech Specs,Removing Existing Footnotes That Limit Application of Apc for Plant S/G Tubes to Cycle 8 Operation for Both Units ML20129G7301996-09-26026 September 1996 Proposed Tech Specs 3/4.3.3 Re Fire Detection instrumentation,3/4.7.11 Re Fire Suppression Systems & 3/4.7.12 Re Fire Protection Penetrations ML20113G2691996-09-20020 September 1996 Proposed Tech Specs Change 96-09, Clarification of Work Shift Durations for Overtime Limits ML20117J3391996-08-28028 August 1996 Proposed Tech Specs Revising Psv & MSSV Setpoint Tolerance from Plus or Minus 1% to Plus or Minus 3% ML20117D1651996-08-22022 August 1996 Proposed Tech Specs of SQN Units 1 & 2,deleting Table 4.8.1, DG Reliability, & Revising Section 3.8.1 to Allow Once Per 18 month,7 Day AOT for EDGs ML20117D3121996-08-22022 August 1996 Proposed Tech Specs,Lowering Minimum TS ice-basket Weight of 1,155 Lbs to 1,071 Lbs.Reduced Overall Ice Weight from 2,245,320 Lbs to 2,082,024 Lbs ML20117D3141996-08-21021 August 1996 Proposed TS 3.7.1.3 Re Condensate Storage Tank ML20117D3341996-08-21021 August 1996 Proposed Tech Specs Re Deletion of Surveillance Requirement 4.8.1.1.1.b ML20112H0431996-06-0707 June 1996 Proposed Tech Specs,Revising Section 6, Administrative Controls, to Be More Closely Aligned W/Requirements of STSs ML20101N7071996-04-0404 April 1996 Proposed Tech Specs,Allowing Conversion from Westinghouse Fuel to Fuel Provided by Framatome Cogema Fuels ML20096B3761996-01-0404 January 1996 Proposed Tech Specs Extending Radiation Monitoring Instrumentation Surveillance Period Per GL 93-05 ML20096C2481996-01-0303 January 1996 Proposed Tech Specs,Revising Bases Section 3/4.7.1.2 to Indicate Current Operational Functions of turbine-driven AFW Level Control Valves Modified During Unit 1 Cycle 7 Refueling Outage 1999-08-30
[Table view] Category:TECHNICAL SPECIFICATIONS & TEST REPORTS
MONTHYEARML20217F9701999-10-14014 October 1999 Proposed Tech Specs,Incorporating ARC for Axial Primary Water Stress Corrosion Cracking at Dented Tube Support Plate Intersections ML20217E4301999-10-12012 October 1999 Proposed Tech Specs,Revising Requirements for Containment Penetrations During Refueling Operations ML20211M7341999-08-30030 August 1999 Marked-up & Revised TS Pages,Providing Alternative to Requirement of Actually Measuring Response Times ML20211K1721999-08-30030 August 1999 Proposed Tech Specs,Providing Clarification to Current TS Requirements for Containment Isolation Valves ML20209B7731999-06-30030 June 1999 Proposed Tech Specs Updating Requirmements for RCS Leakage Detection & RCS Operational Leakage Specifications to Be Consistent with NUREG-1431 ML20196F2211999-06-24024 June 1999 Proposed Tech Specs Pages for Amend to Licenses DPR-77 & DPR-79,allowing Use of Fully Qualified & Tested Spare Inverter in Place of Any of Eight Required Inverters ML20196G4701999-06-24024 June 1999 Proposed Tech Specs Pages Re Amends to Licenses DPR-77 & DPR-79,revising TS to Be Consistent with Rev to ISTS Presently Submitted to NEI TSTF for Submittal as Rev to NUREG-1431 ML20196G7961999-06-22022 June 1999 Proposed Tech Specs Bases,Clarifying Proper Application of TS Requirements for Power Distribution Systems & Functions That Inverters Provide to Maintain Operability & Providing Updated Info on Cold Leg Injection Accumulators ML20196G8071999-06-22022 June 1999 Revs to Technical Requirements Manual ML20195E9841999-06-0707 June 1999 Proposed Tech Specs,Increasing Max Allowed Specific Activity of Primary Coolant from 0.35 Microcuries/Gram Dose Equivalent I-131 to 1.0 Microcuries/Gram Dose Equivalent I-131 for Plant Cycle 10 (U2C10) Core ML20206E1611999-04-29029 April 1999 Proposed Tech Spec Change 99-04, Auxiliary Suction Pressure Low Surveillance Frequency Rev. Change Deletes Surveillance ML20206E1391999-04-29029 April 1999 Proposed Tech Spec Change 99-03, Main Control Room Emergency Ventilation Sys Versus Radiation Monitors. Changes Add LCOs 3.3.3.1 & 3.7.7 to Address Inoperability of Radiation Monitoring CREVS & NUREG-1431 Recommendations ML20204E8501999-03-21021 March 1999 Plant,Four Yr Simulator Test Rept for Period Ending 990321 ML20204H4081999-03-19019 March 1999 Proposed Tech Specs,Relocating TS 3.8.3.1,3.8.3.2,3.8.3.3 & Associated Bases Associated with Electrical Equipment Protective Devices to Technical Requirements Manual ML20207D6331999-02-26026 February 1999 Proposed Tech Specs Providing for Consistency When Exiting Action Statements Associated with EDG Sets ML20207D6011999-02-26026 February 1999 Proposed Tech Specs Relocating TS 3.7.6, Flood Protection Plan & Associated Bases from TS to Plant TRM ML20206S0131999-01-15015 January 1999 Proposed Tech Specs 3.3.3.3, Seismic Instrumentation & Associated Bases,Relocated to Plant Technical Requirements Manual ML20199K6001999-01-15015 January 1999 Proposed Tech Specs Adding New Action Statement to 3.1.3.2 That Would Eliminate Need to Enter TS 3.0.3 Whenever Two or More Individual RPIs Per Bank May Be Inoperable,While Maintaining Appropriate Overall Level of Protection ML20195H6111998-11-16016 November 1998 Proposed Tech Specs Revising EDG SRs by Adding Note That Allows SR to Be Performed in Modes 1,2,3 or 4 If Associated Components Are Already OOS for Testing or Maint & Removing SR Verifying Certain Lockout Features Prevent EDG Starting ML20154H7251998-10-0808 October 1998 Proposed Tech Specs Pages,Supplementing Proposed TS Change 96-08,rev 1 to Add CRMP to Administrative Controls Section & Bases of TS ML20238F1091998-08-27027 August 1998 Proposed Tech Specs Providing for Insertion of Limited Number of Lead Test Assemblies,Beginning W/Unit 2 Operating Cycle 10 Core ML20238F3001998-08-27027 August 1998 Proposed Tech Specs Replacing 72 H AOT of TS 3.8.1.1,Action b,w/7 Day AOT Requirement for Inoperability of One EDG or One Train of EDGs ML20209J1631998-08-0707 August 1998 Rev 41 to Sequoyah Nuclear Plant Odcm ML20236G5961998-06-29029 June 1998 Proposed Tech Specs Typed Pages for TS Change 95-19, Section 6 - Administrative Controls Deletions ML20249C6371998-06-26026 June 1998 Proposed Tech Specs Lowering Specific Activity of Primary Coolant from 1.0 Uci/G Dose Equivalent I-131 to 0.35 Uci/G Dose Equivalent I-131,as Provided in GL 95-05 ML20248F0051998-05-28028 May 1998 Proposed Tech Specs for Section 6, Administrative Controls Deletions ML20217N3511998-04-30030 April 1998 Proposed Tech Specs Pages,Modifying Surveillance Requirement 4.4.3.2.1.b to Change Mode Requirement to Allow PORV Stroke Testing in Modes 3,4 & 5 W/Steam Bubble in Pressurizer Rather than Only in Mode 4 ML20203J1681998-02-25025 February 1998 Proposed Tech Specs Pages,Revising EDG Surveillance Requirements to Delete Requirement for 18-month Insp IAW Procedures Prepared in Conjunction W/Vendor Recommendations & Modify SRs Associated W/Verifying Capability of DGs ML20202J7651998-02-13013 February 1998 Technical Requirements Manual ML20202J7141998-02-13013 February 1998 Proposed Tech Specs Adding New LCO That Addresses Requirements for Main Feedwater Isolation,Regulating & Bypass Valves ML20202J6961998-02-13013 February 1998 Proposed Tech Specs Incorporating MSIV Requirements to Be Consistent W/Std TS (NUREG-1431) ML20202J7601998-02-13013 February 1998 Proposed Tech Specs Section 3.7.9 Re Relocation of Snubber Requirements ML20198T4311998-01-21021 January 1998 Proposed Tech Specs Re New Position Title & Update of Description of Nuclear Organization ML20199F8231997-11-30030 November 1997 Cycle 9 Restart Physics Test Summary, for 971011-971130 ML20199K4571997-11-21021 November 1997 Proposed Tech Specs Adding one-time Allowance Through Operating Cycle 9 to Surveillance Requirement 4.4.3.2.1.b to Perform Stroke Testing of PORVs in Mode 5 Rather than Mode 4,as Currently Required ML20211A3191997-09-17017 September 1997 Proposed Tech Specs Re Pressure Differential Surveillance Requirements for Containment Spray Pumps ML20203B9731997-08-0505 August 1997 Rev 1 to RD-466, Test & Calculated Results Pressure Locking ML20217J5581997-07-31031 July 1997 Cycle Restart Physics Test Summary, for Jul 1997 ML20210J1671997-04-30030 April 1997 Snp Unit 1 Cycle 8 Refueling Outage Mar-Apr 1997,Results of SG Tube ISI as Required by TS Section 4.4.5.5.b & Results of Alternate Plugging Criteria Implementation as Required by Commitment from TS License Condition 2C(9)(d) ML20137T0871997-04-0909 April 1997 Proposed Tech Specs Re Elimination of Cycle 8 Limitation for SG Alternate Plugging Criteria ML20137M8581997-04-0101 April 1997 Proposed Tech Specs 2.1 Re Safety Limits & TS 3/4.2 Re Power Distribution Limits ML20137C8421997-03-19019 March 1997 Proposed Tech Specs Re Conversion from Westinghouse Electric Corp Fuel to Framatome Cogema Fuel ML20136J0381997-03-13013 March 1997 Proposed Tech Specs Section 5.6.1.2,revising Enrichment of Fuel for New Fuel Pit Storage Racks ML20134P8631997-02-14014 February 1997 Proposed Tech Specs Requesting Discretionary Enforcement for 48 Hours Which Is in Addition to 72 Hours Allowed Outage Time Provided by TS Action 3.8.1.1.b ML20134K9981997-02-0707 February 1997 Proposed Tech Specs Revising TS Change Request 96-01, Conversion from W Electric Corp Fuel to Framatome Cogema Fuel (MARK-BW-17), to Ensure That Core Analysis Computer Code Output Actions Are Consistent W/Hot Channel Factor SRs ML20138F2581997-01-17017 January 1997 Rev 39 to Sequoyah Nuclear Plant Odcm ML20134L9261996-11-0808 November 1996 Proposed Tech Specs Re Placing of Channel in Trip for Reactor Trip & Engineered Safety Feature Instrumentation Sys Solely to Perform Testing as Not Requiring Channel to Be Declared Inoperable ML20129D2661996-10-18018 October 1996 Proposed Tech Specs,Removing Existing Footnotes That Limit Application of Apc for Plant S/G Tubes to Cycle 8 Operation for Both Units ML20129G7301996-09-26026 September 1996 Proposed Tech Specs 3/4.3.3 Re Fire Detection instrumentation,3/4.7.11 Re Fire Suppression Systems & 3/4.7.12 Re Fire Protection Penetrations ML20134J9991996-09-23023 September 1996 Fuel Assembly Insp Program 1999-08-30
[Table view] |
Text
. _ _ _
TABLE 3.3-9 REMOTE SHUTDOWN HONITORING INSTRUMENTATION i
S, 2
'
- MINIMUM READ 0UT MEASUREMENT CHANNELS
=
l [ LOCATION RANGE OPERABLE .
j z INSTRUMENT
- w 6
- 1. Source Range Nuclear Flux . NOTE 1 1 to 1 x 10 cps 1
! 2. Reactor Trip Breaker Indication' at trip switchgear OPEN-CLOSE 1/ trip breaker I/ lo6 P
- 3. Reactor Coolant Temperature - NOTE 1 0-650*F l g.
I
~
Hot Leg
- 4. Pressurizer Pressure NOTE 1 0-3000 psig 1 f o- too 9 j ,
- 5. Pressurizer Level NOTE 1 ,
0-525 '- 1 "R i' ) 6. Steam Generator Pressure NOTE 1 0-1200 psig 1/steamgeperator f 7. Steam Generator Level NOTE 2 or l
near Auxilary F. W. 0-100%
Pump 1/ steam generator ,
- 8. Full Length Control Rod Position Auxilary Instrument 1 insertion limit Limit Switches Room: Racks R41-44 On-off switch / rod
- 9. RHR Flow Rate NOTE 1 0-4500 gpa 1 i 10. RHR Temperature NOTE 1 50-400*F 1 o - <4 4 0 eyp w s f shw o,c a n.sk + E
- 11. Auxiliary Feedwater Flow Rate NOTE 1 0-200 ;;- ?
8702090336 870203 PDR ADOCK 05000327 PDR p
'I
. g n g
l l l n
o
~ d ,
1 4
r r t u
o o i m
t t m r
e -
o i
a r
i l
S k e e a n n n m e e e od a .
r g g io e Sl by t r t MLl po m m r/ s UEB a a el i HNA io 1 e e sc 1 1 f,.
I NR 1 rl ! I 1 t t nt s NAL t s s ii I li P // / / w MCO 1 s 1 1 1 s N s O p I c m T
A 6 g p
T T 0 g N N 1 E i 7
. i m
p c) .
E E x
S s' p
s p g :;
M ME O Fo ;;
U G
I L F R RN 1 C 0 4 r
f 0 0 T UA - "0 i l
0! :
0 l f 0 0 4" S SR o N 5 01 2 2 0 o 5 '44" N A L E 6 3 E 1 1 - 4 - - "
I L P - - - - - n - 0 -
9
- G H l O 0 0 O 0 0 0 O 0 5o0 3 N . t 3
. I R
r a
W n4 e4 O e g F
. m-u1 E T I h r4 L
B N O t c y r
tR s
U/.
A T H i a ns t w l Ik N . s ri c W N ox ya 0 I 0 p u rR 0 U1 1 i 1 1 1 1 2A a 1 1 1 l O1 r l :
u DA L t l 0 l l l rp i m E t t l
i AC I l 1 l l l am xo uo I l l S EO O t 0 0 0 0 0eu O 0 o RL N a N N N N NnP AR N N N E
1 0
H E n R o i - ~ e t -
t a e a c r R x i u
u d t e w l n a r ds o F I r u oe l e s l Rh F r r p e s e c a e m r e v lt r e k e u r e oi e l a e
T s l e
P L rw t a
c s tS u r t e v r r n e w N B n r e o o ot r d a P L t t Ci e u e e p l a a m t t e g i o r r t r hi a a f n r o e e e e tL R r a 1 C z z s i
n g e y R i i e e nn w p r r rg r r G G eo o m a e o oe u u Li l e i I
c t tL s s m m t F l l N r c c s s a a~ li i E u a at e e e e l s R R x M o e eol r r t t uo l i
l i u U S R Rl P P S S FP H H A R
T S
N 1 2
3 4
5 6
7 8
9 0
1
) .
I 1 1
,n QESE , c5H m l $ waN
ENCLOSURE 2 PROPOSED TECHNICAL SPECIFICATION CHANGE SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 DOCKET NOS. 50-327, -328 (TVA SQN TS 79)
DESCRIPTION AND JUSTIFICATION FOR PROPOSED CLARIFICATION OF TABLE 3.3-9, REMOTE SHUTDOWN MONITORING INSTRUMENTATION 2
O
DESCRIPTION OF CHANGE This change revises Table 3.3-9, Remote Shutdown Monitoring Instrumentation, on page 3/4 3-51 of unit 1 technical specifications and page 3/4 3-52 of unit 2 technical specifications. The shown measurement range of the pressurizer level (item 5) is changed from 0-525 inch to 0-100 percent, and the shown measurement range of the auxiliary feedwater flow rate (item 11) is changed from 0-880 gpm to 0-440 gpm. The required number of minimum channels operable is clarified by changing the description given for the reactor coolant temperature-hot les (item 3) from 1 to 1/ loop and the description given for the auxiliary feedwater flow rate from 1 to 1/ steam generator.
REASON FOR CHANGE Sequoyah has reviewed the instrument ranges specified in the technical specification. This review identified the two discrepancies in the measurement ranges given in table 3.3-9.
The pressurizer level gauge in the auxiliary control room is calibrated to display percent full from 0 to 100 percent. While the measurement range presently shown in table 3.3-9, 0-525 inches, is used to calibrate the pressurizer level transmitter for a cold system, the pressurizer level gauge of the remote shutdown monitoring instrumentation displays units of percent full. Changing the measurement range to that actually displayed in the auxiliary control room will preclude any possible operator confusion.
The other measurement range discrepancy is the range shown for the auxiliary feedwater flow rate. Each nuclear unit at Sequoyah has two motor-driven auxiliary feedwater pumps (MDAFWP) with a capacity of 440 gpm each and one turbine driven auxiliary feedwater pump (TDAFWP) with a 880 gpm capacity.
This pumping capacity corresponds to 440 gpm of auxiliary feedwater to each of the four steam generators (S/G) per unit. The 0-880 gpm measurement range given in table 3.3-9 is the range for the flow indicator on the discharge of the TDAFWP. Flow indicators on the auxiliary feedwater inlets to the S/G have a range of 0-440 gpm. Since the amount of auxiliary feedwater flow to each S/G is the important parameter, the given measurement range should reflect the 0-440 gpm range of the feedwater inlet indicators. The related surveillance instructions which have been used to satisfy this surveillance requirement calibrate the 0-440 gpm flow indicators. The current range shown is not appropriate.
The two remaining changes which are in the " Minimum Channels Operable" column of table 3.3-9 are for clarification purposes only. These changes will explicitly show what has been assumed in past interpretations.
JUSTIFICATION FOR CHANGE Changing the pressurizer level measurement range from 0-525 inch to 0-100 percent will have no adverse ramifications on nuclear safety. It does not affect the method of calibration for the pressurizer level indicator; however, it will enhance the clarity of table 3.3-9 by establishing a consistency between the units shown on the table and the units shown on the level gauge.
Changing the auxiliary feedwater flow rate range which is indicated in the table from 0-880 gpm to 0-440 gpm will also have no adverse ramifications on nuclear safety. The 0-880 spm is only appropriate for measuring the discharge from the TDAFWP. The parameter which is important'~to nuclear safety is the amount of feedwater flowing into the S/G. The flow indicators for this parameter have a range of 0-440 gpm. The measurement range shown on this table should be appropriate for the flow instrumentation on the auxiliary feedwater inlet to the S/G.
The two changes in the descriptions for the number of minimum channels operable are only editorial in nature and explicitly state previous interpretations. Reactor coolant temperature-hot leg (item 3 in table 3.3-9) has an indicator for each of the four primary loop's. As appropriate, the number of minimum channels has always been interpreted as 1/ loop; however, this was not explicitly shown in table 3.3-9. Since it is important that the temperature in each hot leg is indicated, this requirement should be clearly stated. Likewise, the minimum channels operable for the auxiliary feedwater flow rate (item 11 of table 3.3-9) has always been interpreted as 1 per S/G.
These changes do not alter the intent or the historical interpretation of table 3.3-9 and are justified by the resulting clarity enhancement.
e.
ENCLOSURE 3 PROPOSED TECHNICAL SPECIFICATION CHANGE j SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 DOCKET NOS. 50-327, -328 (TVA SQN TS 79)
DETERMINATION OF NO SIGNIFICANT HAZARDS CONSIDERATIONS FOR PROPOSED CLARIFICATION OF TABLE 3.3-9, REMOTE SHUTDOWN MONITORING INSTRUMENTATION m.
SIGNIFICANT HAZARDS EVALUATION
- 1. Does the proposed amendment involve a significant increase in the probability or consequences of an accident previously evaluated?
No. The proposed amendment only clarifies table 3.3-9 and it does not alter the operation of the plant. The pressurizer level measurement range shown in the table is revised to establish consistency with the units shown on the pressurizer level gauge. The auxiliary feedwater flow measurement range shown in the table is revised to establish consistency with the auxiliary feedwater flow range to each of the steam generators.
The two changes under the " Minimum Channels Operable" column are editorial and explicitly state previously accepted interpretations.
- 2. Does the proposed amendment create the possibility of a new or different kind of accident from any accident previously evaluated?
No. The proposed amendment is basically editorial and it is requested for clarification purposes. The plant design is not affected.
- 3. Does the proposed amendment involve a significant reduction in a margin of safety?
No. The proposed amendment can only enhance ' safety since it reduces the probability of misinterpretation or confusion.
,. , __ , . - - - - _ . . _ . . _ - - . . _ , . . - , _ . - _ . , _ , _ -- - - _ - _ - _ . _ _ _ _ - .