MONTHYEARML20217C1311999-10-0808 October 1999 Safety Evaluation Supporting Amend 153 to License DPR-3 ML20211J3361999-08-27027 August 1999 Safety Evaluation Supporting Amend 152 to License DPR-3 ML20207F9491999-03-0505 March 1999 Safety Evaluation Supporting Amend 151 to License DPR-3 ML20202H5871999-02-0303 February 1999 Safety Evaluation Supporting Amend 150 to License DPR-3 ML20249A7901998-06-17017 June 1998 Safety Evaluation Supporting Amend 149 to License DPR-3 ML20237F1671993-02-19019 February 1993 Safety Evaluation Supporting Amend 147 to License DPR-3 ML20058F2201990-11-0202 November 1990 Safety Evaluation Accepting Util Response to Generic Ltr 83-28 Re post-trip Review - Data & Info Capability ML20058C4061990-10-22022 October 1990 Safety Evaluation Supporting Amend 137 to License DPR-3 ML20059G2411990-09-0606 September 1990 Safety Evaluation Supporting Amend 135 to License DPR-3 ML20058L6651990-08-0202 August 1990 Safety Evaluation Supporting Amend 134 to License DPR-3 ML20058L0321990-08-0202 August 1990 Safety Evaluation Supporting Amend 133 to License DPR-3 ML20055C8601990-06-18018 June 1990 Safety Evaluation Supporting Amend 132 to License DPR-3 ML20248H7391989-10-0303 October 1989 Safety Evaluation Not Accepting Procedure Generating Program for Plant.Program Should Be Revised to Reflect Items Described in Section 2 of Rept.Revision Need Not Be Submitted to NRC ML20247F1431989-09-0707 September 1989 Safety Evaluation Supporting Amend 124 to License DPR-3 ML20247E6831989-08-31031 August 1989 Safety Evaluation Supporting Amend 123 to License DPR-3 ML20246F2771989-07-11011 July 1989 Safety Evaluation Supporting Mods to ECCS Evaluation Model, Including Changes to FLECHT-based Reflood Heat Transfer Correlation,Steam Cooling Model & post-critical Heat Flux Heat Transfer Model ML20195D6701988-11-0101 November 1988 Safety Evaluation Supporting Amend 120 to License DPR-3 ML20205G1961988-10-25025 October 1988 Safety Evaluation Supporting Amend 119 to License DPR-3 ML20204G4871988-10-17017 October 1988 Safety Evaluation Supporting Amend 118 to License DPR-3 ML20205C4061988-10-14014 October 1988 Safety Evaluation Supporting Amend 117 to License DPR-3 ML20207L7051988-10-12012 October 1988 Safety Evaluation Supporting Amend 116 to License DPR-3 ML20207E8151988-08-0505 August 1988 Safety Evaluation Supporting Amend 115 to License DPR-3 ML20151M4911988-07-29029 July 1988 Safety Evaluation Supporting Amend 114 to License DPR-3 ML20151K3801988-07-25025 July 1988 Safety Evaluation Supporting Amend 113 to License DPR-3 ML20151K8571988-07-19019 July 1988 Safety Evaluation Supporting Amend 112 to License DPR-3 ML20153A8661988-06-29029 June 1988 Safety Evaluation Accepting Util Proposed Reflood Steam Cooling Model ML20196K2741988-06-28028 June 1988 Safety Evaluation Supporting Amend 111 to License DPR-3 ML20195K1501988-06-17017 June 1988 Safety Evaluation Supporting Amend 110 to License DPR-3 ML20195C5851988-06-13013 June 1988 Safety Evaluation Supporting Amend 109 to License DPR-3 ML20155K5141988-06-0909 June 1988 Safety Evaluation Supporting Amend 108 to License DPR-3 ML20154J7661988-05-18018 May 1988 Safety Evaluation Supporting Amend 107 to License DPR-3 ML20216J4081987-06-26026 June 1987 Safety Evaluation Supporting Amend 106 to License DPR-3 ML20216C1111987-06-18018 June 1987 Safety Evaluation Granting Three of Seven Requests Submitted by Util for Relief from Inservice Insp & Testing Requirements.Four Requests Withdrawn,Per 870122,0410 & 0507 Ltrs ML20215C5881987-06-0404 June 1987 Safety Evaluation Supporting Util 860505,870402,& 0506 Submittals Re Seismic Reevaluation of Plant.Concludes That Foundation Soils Under Reactor & Under Vapor Container Have Adequate Strength to Support Seismic Load from Earthquake NUREG-0825, Safety Evaluation Supporting Util 840709,1231 & 851024 Repts Re Evaluation of Plant for Wind & Tornado Events as Requested in Integrated Plant Safety Assessment Rept, Sections 4.5 & 4.8.Risk from Wind/Tornado Events Assessed1987-05-13013 May 1987 Safety Evaluation Supporting Util 840709,1231 & 851024 Repts Re Evaluation of Plant for Wind & Tornado Events as Requested in Integrated Plant Safety Assessment Rept, Sections 4.5 & 4.8.Risk from Wind/Tornado Events Assessed ML20213G9161987-05-13013 May 1987 Safety Evaluation Supporting Amend 105 to License DPR-3 ML20213D9671987-05-0707 May 1987 Safety Evaluation Supporting Amend 104 to License DPR-3 ML20207S6231987-03-10010 March 1987 Safety Evaluation Supporting Util 860122,0812,1028 & 870204 Submittals Re Fracture Toughness Requirements for Protection Against PTS Events ML20211N5881987-02-19019 February 1987 Safety Evaluation Re First Level Undervoltage Protection Testing.Testing Unnecessary ML20211L3951987-02-17017 February 1987 Safety Evaluation Supporting Amend 103 to License DPR-3 Re Max Nominal Enrichment of Fuel ML20207N8811987-01-0707 January 1987 Safety Evaluation Supporting Amend 102 to License DPR-3 ML20207N4261987-01-0606 January 1987 Safety Evaluation Supporting Amend 101 to License DPR-3 ML20207J9451986-12-30030 December 1986 SER Accepting Util 831105 & 850709 Responses to Generic Ltr 83-28,Item 2.1 (Part 2), Vendor Interface Program - Reactor Trip Sys Components ML20215E1201986-12-0909 December 1986 Safety Evaluation Supporting Util 830419 & 0830,840119, 851022 & 860930 Responses Re Conformance to Reg Guide 1.97. Plant Design Acceptable W/Exception of Neutron Flux Variable ML20214X3391986-12-0101 December 1986 Safety Evaluation Supporting Amend 100 to License DPR-3 ML20214J8521986-11-18018 November 1986 Sser Accepting SPDS Contingent Upon Resolution of Concerns Re Maint & Improvement of Placement & Visual Access of Containment Isolation Panel & Minor Human Factors Engineering Concerns ML20215E6471986-10-0202 October 1986 Safety Evaluation Supporting Util Requests for Exemption from Specific Requirements in App R to 10CFR50.Existing Fire Protection Provides Level of Protection Equivalent to Technical Requirements of App R ML20210S1791986-09-23023 September 1986 Safety Evaluation Supporting Amend 99 to License DPR-3 ML20212Q1151986-08-27027 August 1986 Safety Evaluation Supporting Util 830412 Proposal to Provide Integrated Safe Shutdown Sys Which Could Be Used for Safe Shutdown in Event of Fire at Facility ML20212N0161986-08-20020 August 1986 Safety Evaluation Supporting Amend 98 to License DPR-3 1999-08-27
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML20217C1311999-10-0808 October 1999 Safety Evaluation Supporting Amend 153 to License DPR-3 ML20211J5111999-08-31031 August 1999 Rev 29 to Yankee Decommissioning QA Program ML20211J3361999-08-27027 August 1999 Safety Evaluation Supporting Amend 152 to License DPR-3 ML20209D5391999-06-22022 June 1999 Rev 29 to Yaec Decommissioning QA Program ML20207F9491999-03-0505 March 1999 Safety Evaluation Supporting Amend 151 to License DPR-3 ML20202H5871999-02-0303 February 1999 Safety Evaluation Supporting Amend 150 to License DPR-3 ML20154P9691998-10-16016 October 1998 Rev 28 to Yankee Atomic Electric Co Decommissioning QA Program ML20249A7901998-06-17017 June 1998 Safety Evaluation Supporting Amend 149 to License DPR-3 ML20216C4581998-02-27027 February 1998 Response to NRC Demand for Info (NRC OI Rept 1-95-050) ML20203L1931998-02-25025 February 1998 Duke Energy Corp,Duke Engineering & Svcs,Inc,Yankee Atomic Small Break LOCA Technical Review Rept ML20203L2451998-02-23023 February 1998 Assessment Rept of Engineering & Technical Work Process Utilized at De&S Bolton Ofc ML20203L1621998-02-18018 February 1998 Rept of Root Cause Assessment Review ML20203L2691998-02-16016 February 1998 Duke Engineering & Svcs Assessment Process Review Rept ML20199B4601998-01-20020 January 1998 Special Rept:On 980105,meteorological Monnitoring Instrumentation for Air Temp Delta T Inoperable for More than 7 Days.Caused by Breakdown in Wiring Between Junction Box at 199 Foot Level.Wiring Replaced ML20203J3001997-12-31031 December 1997 Ynps 1997 Annual Rept ML20217N0981997-08-21021 August 1997 LER 97-S02-00:on 970725,discovered Uncontrolled Safeguards Documents.Caused by Personnel Error.Matls Retrieved & Stored in Safeguards Repositories ML20210H0991997-08-0707 August 1997 LER 97-S01-00:on 970709,potential Compromise of Safeguards Info Occurred.Caused by Human error.Stand-alone Personal Computer & Printer Not Connected to Network,Have Been Located within Text Graphics Svc Dept ML20149K7781997-07-24024 July 1997 Special Rept:On 970520 & 0714,air Temp Delta T Channel Indicated Temp Difference Between Top & Bottom of Meteorological Tower.Caused by Reversed Input Wiring to Channel.Restored Air Temp Delta T Channel Operability ML20141E4671997-05-30030 May 1997 Rev 28 to Operational QA Program ML20135C8461996-12-31031 December 1996 Yankee Nuclear Power Station 1996 Annual Rept ML20132G6771996-12-20020 December 1996 Rev 27 to YOQAP-I-A, Operational QA Program ML20058N4771993-12-20020 December 1993 Rev 0.0 to Yankee Nuclear Power Station Decommissioning Plan ML20059K8491993-12-15015 December 1993 Clarifications to Pages 2,41,43 & 44 of 44 in Section I, Organization of YOQAP-I-A,Rev 24, Operational QA Program ML20059C5011993-10-29029 October 1993 Special Rept:On 931019,meteorological Instrumentation Channel for Delta T Declared Inoperable.Caused by Ceased Aspirator Motor Located at Top of Tower.Motor Replaced ML20056H1741993-06-10010 June 1993 Preliminary Assessment of Potential Human Exposures to Routine Tritium Emissions from Yankee Atomic Electric Co Nuclear Power Facility Located Near Rowe,Ma ML20237F1671993-02-19019 February 1993 Safety Evaluation Supporting Amend 147 to License DPR-3 ML20125C7161992-12-0707 December 1992 Part 21 Rept Re Possibility for Malfunction of Declutching Mechanisms in SMB/SB-000 & SMB/SB/SBD-00 Actuators. Malfunction Only Occurs During Seismic Event.Balanced Levers May Be Purchased from Vendor.List of Affected Utils Encl ML20198D2481992-05-13013 May 1992 Yankee Nuclear Power Station Certified Fuel Handler Initial Certification Program ML20198D2541992-05-13013 May 1992 Yankee Nuclear Power Station Certified Fuel Handler Recertification Program ML20062H1981990-11-30030 November 1990 Plant Specific Fast Neutron Exposure Evaluations for First 20 Operating Fuel Cycles of Yankee Rowe Reactor ML20058H2841990-11-0303 November 1990 Special Rept:On 901101,control Rod 24 Found Disconnected from Drive Shaft.Drive Shaft Latching Will Be Initiated ML20058F2201990-11-0202 November 1990 Safety Evaluation Accepting Util Response to Generic Ltr 83-28 Re post-trip Review - Data & Info Capability ML20062E8331990-10-31031 October 1990 Monthly Operating Rept for Oct 1990 for Yankee Atomic Power Station ML20058G1471990-10-31031 October 1990 Vol 2 to Star Methodology Application for PWRs Control Rod Ejection Main Steam Line Break ML20058C4061990-10-22022 October 1990 Safety Evaluation Supporting Amend 137 to License DPR-3 ML20062B6751990-09-30030 September 1990 Monthly Operating Rept for Yankee Atomic Power Station for Sept 1990 ML20059G2411990-09-0606 September 1990 Safety Evaluation Supporting Amend 135 to License DPR-3 ML20059E3071990-08-31031 August 1990 Safety Assessment of Yaec 1735, Reactor Pressure Vessel Evaluation Rept for Yankee Nuclear Power Station. Detailed Plan of Action W/Listed Elements Requested within 60 Days After Restart to Demonstrate Ability to Operate Longer ML20059E8001990-08-31031 August 1990 Monthly Operating Rept for Aug 1990 for Yankee Atomic Power Station ML20058P7841990-08-14014 August 1990 Part 21 Rept Re Misapplication of Fluorolube FS-5 Oil in Main Steam Line Pressure Gauges.All Four Indicators Replaced W/Spare Gauges Which Utilize High Temp Silicone Oil ML20058N6581990-08-13013 August 1990 Special Rept Re Diesel Fire Pump & Tank Inoperable for Greater than Seven Days for Draining,Cleaning & Insp.During Period Redundant Pumping Capacity Available Via Two Remaining Electric Driven Fire Pumps ML20058L0321990-08-0202 August 1990 Safety Evaluation Supporting Amend 133 to License DPR-3 ML20058L6651990-08-0202 August 1990 Safety Evaluation Supporting Amend 134 to License DPR-3 ML20056A1961990-08-0101 August 1990 Special Rept:Two Fire Pumps Inoperable at Same Time.Caused by Necessity to Accomplish Surveillance to Verify Capability to Start Pump on Emergency Diesel Generator 3 & Planned 18-month Insp of Diesel Per Tech Specs ML20055E1591990-07-31031 July 1990 Reactor Pressure Vessel Evaluation Rept ML20055G7011990-07-31031 July 1990 Yankee Nuclear Power Station Core 21 Performance Analysis ML20055G6801990-07-31031 July 1990 Yankee Plant Small Break LOCA Analysis ML20055J3221990-07-25025 July 1990 Decommissioning Funding Assurance Rept & Certification ML20055G7051990-07-19019 July 1990 Rev 0 to Yankee Cycle 21 Core Operating Limits Rept ML20055F6751990-06-30030 June 1990 Monthly Operating Rept for June 1990 for Yankee Atomic Power Station 1999-08-31
[Table view] |
Text
i Q
ENCLOSURE SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATING TO REFLOOD STEAM COOLING MODEL YANKEE ATOMIC ELECTRIC COMPANY 00CKET NO.50-029
1.0 INTRODUCTION
In a letter from G. Whittier to V. Nerses, (USNRC), dated May 21, 1987, Maine Yankee Atomic Power Company (MYAPCo) provided analyses for a proposed revised steam cooling model. The steam cooling model is to be used to calculate heat transfer during the reflood phase of a loss-of-Coolant-Accident (LOCA) for Maine Yankee Nuclear Plant. By a January 5, 1988 letter from G. Papanic to M.
Fairtile (USNRC), Yankee Atomic Electric Company (YAECo) a?so submitted analyses for a revised steam cooling model for Yankee Rowe Nuclear Plant.
Because the proposals by both licensees are identical, and because the current Maine Yankee and Yankee Rowe steam cooling models for LOCA are virtually identical, this evaluation applies to both referenced proposals.
According to Appendix K of 10CFR50, Section I.0.5, heat transfer must be assumed to be accomplished via cooling by steam only when reflood rates in the core fall below one inch per second. Also, flow blockage must be considered in the steam cooling model in terms of both heat transfer and steam flow. Currently, both MYAPCo and YAECo steam cooling models exemplify and use these two characteristic requirements conservatively. With the proposed modifications, additional heat transfer capability would be credited in the LOCA analyses, thereby lessening the conservativeness of the current steam cooling model.
As it staads now, the steam cooling model is basically a correlation based on FLECHT test data- A penalty is incorporated in the model, in accordance with Appendix K, to account for the effect of flow channel blockage, As proposed, the steam cooling model modification would take credit for sore enhancement in heat transfer as reflected in the more recent test data. The aroposed model would, however, continue to include the specific conservatisms required by Appendix K. Thus, although the proposal would eliminate excessive conservatism, sufficient conservatism in the model would remain.
2.0 EVALUATION Analyses by MYAPCo and YAECo were done with a wide range of test data.
Included were FLECHT-SEASET data results which showed heat transfer enhancement. The staff notes that the tests were conducted for both blocked and unblocked test assemblies, for densely rodded assembly and sparsely rodded assembly configurations, and with and without bypass flow. Heat transfer was consistently found to be enhanced during low reflood rates. Sensitivity studies performed by the licensees were also consistent with these findings.
8807120642 880629 PDR ADOCK 05000029 P
PDR
Two effects are believed by the licensees to contribute to the overall heat transfer enhancement demonstrated by the test results and by the COBRA-TF computer program results. They are droplet breakup and sing'e phase ,
turbulence. The assumed presence of droplets, however, would violate the Appendix K requirement that cooling may only be assumed by steam. Single phase (gaseous) turbulence c'ownstream of the blockage is therefore considered by the licensees to be the main contributor for the heat transfer enhancement seen in the more recent test data.
Evaluations were performed by the licensees using various experiments to deduce relationships representing ti:e effects of turtsulent steam flow behavior. The relationships represented the effects in terms of Musselt numbers and showed an exponential decrease in heat transfer enhancement as distance from the blockage increased. The resultant modification to the model was benchmarked and compared to experimental and test results, and were found to be in good agreement.
We are not convinced that the proposed model truly represents the flow regime downstream of the blockage; the physical basis given for the heat transfer enhancement is questionable. However, the staff recognizes that the Appendix K steam cooling model requirements were administered due to a lack of experimental data at low flooding rate. Data generated since the development of Appendix K has demonstrated that reflood heat transfer characteristics at low reflooding rates (less than ore inch per second) are similar to heat transfer characteristics at reflooding rates greater than one inch per second. Thus, staff practice is to assure that steam cooling models developed
^
by 1teensees meet the specific requirements of Appendix K, i.e., effect on flow diversion, while conservatively predicting heat transfer observed in the experimental data. Regardless of the physical ieterpretation applied to the model, the proposed model was shown to conservatively predict the recent experimental data in accordance with 10 CFR Part 50, Appendix K. No change in the flow divergence model would result from the incorporation of the proposed model. Therefore, we find the proposed modification to he acceptablo.
3.0 CONCLUSION
S Analyses of test data by the licensees show an overall heat transfer enhancement for reflood rates less than one inch per second. The licensees have incorporated a modification to their steam cooling model which better predicts this increased heat transfer as demonstrated in the more recently accumulated reflood heat transfer data. Although the physical interpretation of the additional enhancement is unclear, the model as proposed was demonstrated to be conservative with respect to Fl.ECHT results. Since the model complies with the requirements of Section I.D.5 of Appendix K of 10CFR50, we find the proposed steam cooling model revision acceptable.
4.0 REFERENCES
- 1. Letter from G. Papanic, Jr. (Yankee Atomic Electric Co.) to M. Fairtile (NRC), dated January 5, 1988.
- 2. Letter from G. Whittier (Maine Yankee Atomic Pcwer Co.) to V. Nerses (NRC), dated May 21, 1987.
.; ( -
3
- 3. Letter from G. Whittier (MYAPCo) to A. Thadani (NRC), dated November 10, 1986.
- 4. Letter from D. Crutchfield (NRC) to G. Ward (Exxon Nuclear Co.), dated July 8, 1986.
- 5. Letter from R. Groce (MYAPCo) to NRR (NRC), dated January 15, 1979.
- 6. "Application of Yankee-WREM-BASED Generic PWR ECCS Evaluation Model to Maine Yankee," YAEC-116, dated Jely 1978.
- 7. L. E. Hochreiter, "FLECHT-SEASET Program Final Report,"
NRC/EPRI/Kestinghouse-16, dated November 1985, i
.