(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Letter Sequence Other |
---|
TAC:MB7842, Steam Generator Tube Integrity (Approved, Closed) TAC:MB7843, Steam Generator Tube Integrity (Approved, Closed) |
|
MONTHYEARML0312100452002-04-30030 April 2002 Request for Additional Information Project stage: RAI ML0306900292003-02-25025 February 2003 Application for Amendment to Licenses NPF-35 & NPF-52, to Change & Add Technical Specifications Project stage: Request ML0308302972003-03-24024 March 2003 Ltr, Steam Generator Program Guidelines Project stage: Other ML0313407572003-04-24024 April 2003 Request for Additional Information - Catawba, Unit 1 and 2 - Tech Spec Amendment - Steam Generators Project stage: RAI ML0312105682003-04-30030 April 2003 Enclosure 3, Tech Spec Base Changes for Catawba, Units 1 and 2 Project stage: Other ML0313403232003-05-14014 May 2003 Informal Transmittal of Request for Additional Information Project stage: RAI ML0315005992003-05-29029 May 2003 Ltr, Position on Technical Specifications for Steam Generators Project stage: Other ML0316713472003-06-0909 June 2003 Proposed Technical Specifications (TS) Amendments Revision to Steam Generator TS Project stage: Other ML0320200852003-07-21021 July 2003 Regarding Further Request for Additional Information Project stage: RAI ML0321806302003-07-30030 July 2003 Duke Energy Corporation Catawba Nuclear Station, Units 1 and 2 Proposed Technical Specifications (TS) Amendments Revision to Steam Generator TS Project stage: Other ML0326009902003-09-17017 September 2003 Request for Additonal Information Resulting from Licensee Letter Dated July 30, 2003 Project stage: Other ML0328301532003-10-10010 October 2003 Revised Request for Additional Information Resulting from Licensee Letter Dated July 30, 2003 Project stage: RAI ML0407001772004-03-11011 March 2004 Memo to J. Nakoski Transmittal of Request for Additional Information Project stage: RAI ML0407204072004-03-24024 March 2004 RAI, Steam Generator Tube Integrity Criteria Project stage: RAI ML0416103812004-06-0909 June 2004 Withdrawal of Requests for Additional Information Ltr, Steam Generator Tube Integrity Criteria Project stage: Withdrawal ML0426602802004-09-13013 September 2004 Proposed Technical Specifications (TS) Amendments Revision to Steam Generator TS Project stage: Other ML0433500632005-01-13013 January 2005 Catabwa, Units 1 & 2, Issuance of License Amendments 218 and 212 Steam Generator Tube Integrity Project stage: Approval ML0501901302005-01-13013 January 2005 Enclosure, Amendment, TS for SG Tube Integrity (Tac No. MB7842, MB7843) Project stage: Acceptance Review 2003-06-09
[Table View] |
|
---|
Category:Letter
MONTHYEARIR 05000413/20230042024-02-0202 February 2024 Integrated Inspection Report 05000413-2023004 and 05000414-2023004 ML24005A2512024-01-26026 January 2024 Exemption from Select Requirements of 10 CFR Part 73 - Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting ML23317A3462023-11-14014 November 2023 Duke Fleet - Correction Letter to License Amendment Nos. 312 & 340 Issuance of Amendments Regarding the Adoption of Technical Specifications Task Force Traveler TSTF-554, Revision 1 IR 05000413/20230102023-10-11011 October 2023 NRC Inspection Report 05000413/2023010 and 05000414/2023010 ML23256A0882023-09-25025 September 2023 Issuance of Alternative to Steam Generator Welds ML23195A0782023-08-29029 August 2023 Issuance of Amendments Regarding the Adoption of Technical Specifications Task Force Traveler TSTF-554, Revision 1 IR 05000413/20230052023-08-25025 August 2023 Updated Inspection Plan for Catawba Nuclear Station Units 1 and 2 (Report 05000413/2023005 and 05000414/2023005) ML23233A1692023-08-17017 August 2023 EN 56683 - Curtiss Wright, Interim Notification Report for PotentialPurt2l IR 05000413/20230022023-07-25025 July 2023 Integrated Inspection Report 05000413/2023002 and 05000414/2023002 ML23207A0762023-07-14014 July 2023 EN 56557 - Update to Part 21 Report Re Potential Defect with Trane External Auto/Stop Emergency Stop Relay Card Pn: XI2650728-06 ML23237A2672023-06-13013 June 2023 June 13, 2002 - Meeting Announcement - McGuire and Catawba Nuclear Stations 50-369, 50-370 and 50-413, 50-414 ML23159A0052023-06-0505 June 2023 56557-EN 56557 - Paragon - Redlined IR 05000413/20230012023-05-0505 May 2023 Integrated Inspection Report 05000413/2023001 and 05000414/2023001 ML23118A0762023-05-0101 May 2023 Approval for Use of Specific Provision of a Later Edition of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section XI IR 05000413/20230112023-04-25025 April 2023 Focused Engineering Inspection Report 05000413/2023011 and 05000414/2023011 ML23107A2542023-04-14014 April 2023 301 Examination Report Letter and Report (Merged) ML22332A4932023-03-10010 March 2023 William States Lee III 1 and 2 - Issuance of Amendments Regarding the Relocation of the Emergency Operations Facility IR 05000413/20220062023-03-0101 March 2023 Annual Assessment Letter for Catawba Nuclear Station, Units 1 and 2 (NRC Inspection Report 05000413/2022006 and 05000414/2022006) IR 05000413/20234012023-03-0101 March 2023 Security Baseline Inspection Report 05000413 2023401 and 05000414 2023401 IR 05000413/20233012023-02-17017 February 2023 Operator Licensing Examination Approval 05000413/2023301 and 05000414/2023301 IR 05000413/20220042023-01-31031 January 2023 Integrated Inspection Report 05000413/2022004 and 05000414/2022004 IR 05000413/20220112022-12-15015 December 2022 Biennial Problem Identification and Resolution Inspection Report 05000413/2022011 and 05000414/2022011 ML22356A0512022-12-14014 December 2022 Curtiss-Wright Nuclear Division, Letter Regarding Potential Efect in a Configuration of the 11/2 Inch Quick Disconnect Connector Cable Assemblies Supplied to Duke Energy (See Attached Spreadsheet) for a Total of 460 of Connectors Only Suppl ML22096A0032022-11-18018 November 2022 McGuire Nuclear Station and Shearon Harris Nuclear Power Plant Authorization of RA-19-0352 Regarding Use of Alternative for RPV Head Closure Stud Examinations IR 05000413/20224032022-11-17017 November 2022 Cyber Security Inspection Report 05000413/2022403 and 05000414/2022403 (Public) ML22256A2532022-11-14014 November 2022 Issuance of Amendments Regarding the Adoption of Technical Specifications Task Force Traveler TSTF-541, Rev. 2 ML22319A0942022-11-10010 November 2022 EN 56219 - Flowserve. 10 CFR Part 21 Report 38878-8 Solenoid Valve at Duke, Catawba Flowserve Evaluation 105 IR 05000414/20220032022-10-31031 October 2022 Integrated Inspection Report 05000414/2022003 and 05000414/2022003 IR 05000413/20224022022-10-28028 October 2022 Security Baseline Inspection Report 05000413 2022402 and 05000414 2022402 ML22297A2642022-10-25025 October 2022 Project Manager Assignment ML22276A2492022-10-25025 October 2022 Completion of License Renewal Commitment No. 10, Aging Management of Environmentally Assisted Fatigue ML22303A0052022-10-24024 October 2022 EN 56178 - Tioga Final. LTR-TP-22-29 2021 10CFR Part 21 Improper Notification of NRC ML22258A0302022-09-15015 September 2022 Evacuation Time Estimate Reports ML22242A0022022-09-12012 September 2022 Issuance of Amendments to Adopt TSTF 569, Revision 2, Revise Response Time Testing Definition ML22231B1362022-09-0101 September 2022 Review of the Draft Environmental Assessment and Findings of No Significant Impact for Catawba Nuclear Station, H.B. Robinson Steam Electric Plant, and Oconee Nuclear Station Independent Spent Fuel Storage Installation Decommissioning Fundi ML22303A0042022-08-31031 August 2022 Final Report Notification Pursuant to 10 CFR Part 21.21, Regarding Supply of 6 NPS Sch. 40 Seamless Stainless-Steel Pipe; Manufacturer: Maxim Tubes Company Pvt. Ltd.; Heat No: N200309AW01, SR No: 7; 9 Pcs; 180 Feet Total Procured as Unquali IR 05000413/20220052022-08-26026 August 2022 Updated Inspection Plan for Catawba Nuclear Station, Units 1 and 2 - NRC Inspection Report 05000413/2022005 and 05000414/2022005 ML22217A0792022-08-0303 August 2022 301, Corporate Notification Letter (210-day Ltr) IR 05000413/20220022022-07-29029 July 2022 Integrated Inspection Report 05000413/2022002 and 05000414/2022002 IR 07200045/20220012022-07-26026 July 2022 Operation of an Independent Spent Fuel Storage Installation Report 07200045/2022001 ML22215A2502022-07-25025 July 2022 EN 55960 - Update - Curtiss Wright IR 05000413/20220102022-07-21021 July 2022 Design Basis Assurance Inspection (Programs) Inspection Report 05000413/2022010 and 05000414/2022010 ML22195A2432022-07-19019 July 2022 Request for Withholding Information from Public Disclosure Regarding Reactor Vessel Closure Head Repair Alternative ML22164A0362022-07-19019 July 2022 Mcguire Nuclear Station, Units 1 and 2; Issuance of Amendments to Revise the Conditional Exemption of the End-Of-Cycle Moderator Temperature Coefficient Measurement Methodology (EPID L-2021-LLA-0198) Public ML22199A2552022-07-0606 July 2022 Ds Catawba 2022 RQ Inspection Notification Letter ML22222A0092022-07-0101 July 2022 EN 55974 - Flowserve, Part 21 Report Re Solenoid Coil Failure of Model 38878-8 Solenoid Valve at Catawba Nuclear Station for Use on FWIV Actuator ML22175A0342022-06-28028 June 2022 Information Request for the Cyber-Security Baseline Inspection Notification to Perform Inspection 05000413/2022403 and 05000414/2022403 ML22046A0222022-06-14014 June 2022 Issuance of Amendments to Adopt TSTF-439, Eliminate Second Completion Times Limiting Time from Discovery of Failure to Meet an LCO ML22111A3572022-05-16016 May 2022 Letter Issuing Exemption to Catawba IR 05000414/20220012022-04-28028 April 2022 Integrated Inspection Report 05000413/ 2022001 and 05000414/2022001 2024-02-02
[Table view] |
Text
May 29, 2003 Mr. G. R. Peterson Vice President, Catawba Site Duke Energy Corporation 4800 Concord Road York, SC 29710
SUBJECT:
CATAWBA NUCLEAR STATION, UNITS 1 AND 2 - POSITION ON TECHNICAL SPECIFICATIONS FOR STEAM GENERATOR INSPECTION (TAC NOS. MB7842 AND MB7843)
Dear Mr. Peterson:
By letter dated February 25, 2003, you submitted an application for amendment to change the requirements for inspection of the steam generators. By letter dated April 30, 2003, we sent you a request for additional information.
Our review has determined that there is a problem with one area of your application for amendment. The proposed Technical Specification (TS) Surveillance Requirement (SR) 3.4.13.2 requires verification that primary-to-secondary leakage is less than or equal to 150 gallons per day through any one steam generator. The proposed frequency in SR 3.4.13.2 is in accordance with the Steam Generator Program. After review, we have concluded that the frequency must be specified in some fashion, either in the TS itself or by reference in the TS to an NRC approved program or method. Inasmuch as there is no such NRC-approved program or method, it would appear appropriate to specify the surveillance frequency in the TS. Our conclusion is based on the fact that the frequency of a required surveillance is material to the performance of the surveillance. This position is consistent with the staffs Final Policy Statement on Technical Specification Improvements for Nuclear Power Reactors, 58 FR 39132 (July 22, 1993).
Please contact me at 301 415-1419 if you have any questions on this matter.
Sincerely,
/RA/
Leonard N. Olshan, Project Manager Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-413 and 50-414 cc: See next page
ML031500599 OFFICE PDII-1/LA PDII-1/LA PDII-1/SC OGC NAME LOlshan:mw CHawes JNakoski See previous conc.
DATE 05/29/2003 05/29/2003 05/29/2003 05/28/2003 Catawba Nuclear Station cc:
Mr. Gary Gilbert North Carolina Electric Membership Regulatory Compliance Manager Corporation Duke Energy Corporation P. O. Box 27306 4800 Concord Road Raleigh, North Carolina 27611 York, South Carolina 29745 Senior Resident Inspector Ms. Lisa F. Vaughn U.S. Nuclear Regulatory Commission Legal Department (ECIIX) 4830 Concord Road Duke Energy Corporation York, South Carolina 29745 422 South Church Street Charlotte, North Carolina 28201-1006 Virgil R. Autry, Director Division of Radioactive Waste Management Anne Cottingham, Esquire Bureau of Land and Waste Management Winston and Strawn Department of Health and Environmental 1400 L Street, NW Control Washington, DC 20005 2600 Bull Street Columbia, South Carolina 29201-1708 North Carolina Municipal Power Agency Number 1 Mr. C. Jeffrey Thomas 1427 Meadowwood Boulevard Manager - Nuclear Regulatory P. O. Box 29513 Licensing Raleigh, North Carolina 27626 Duke Energy Corporation 526 South Church Street County Manager of York County Charlotte, North Carolina 28201-1006 York County Courthouse York, South Carolina 29745 Saluda River Electric P. O. Box 929 Piedmont Municipal Power Agency Laurens, South Carolina 29360 121 Village Drive Greer, South Carolina 29651 Mr. Peter R. Harden, IV VP-Customer Relations and Sales Ms. Karen E. Long Westinghouse Electric Company Assistant Attorney General 6000 Fairview Road North Carolina Department of Justice 12th Floor P. O. Box 629 Charlotte, North Carolina 28210 Raleigh, North Carolina 27602 NCEM REP Program Manager 4713 Mail Service Center Raleigh, NC 27699-4713
Catawba Nuclear Station cc:
Mr. T. Richard Puryear Owners Group (NCEMC)
Duke Energy Corporation 4800 Concord Road York, South Carolina 29745 Richard M. Fry, Director Division of Radiation Protection North Carolina Department of Environment, Health, and Natural Resources 3825 Barrett Drive Raleigh, North Carolina 27609-7721 Mr. G. R Peterson Site Vice President Catawba Nuclear Station Duke Energy Corporation 4800 Concord Road York, South Carolina 29745-9635