MONTHYEARPLA-8096, Response to Request for Additional Information Regarding Proposed Relief Request for the Fifth 10-Year Inservice Test Program Interval2024-01-0404 January 2024 Response to Request for Additional Information Regarding Proposed Relief Request for the Fifth 10-Year Inservice Test Program Interval PLA-8077, Emergency Plan Revision 67 (PLA-8077)2023-12-27027 December 2023 Emergency Plan Revision 67 (PLA-8077) PLA-8089, Submittal of Revision to Inservice Testing Program Plan2023-12-0505 December 2023 Submittal of Revision to Inservice Testing Program Plan PLA-8084, Application to Revise Technical Specifications to Adopt TSTF-568, Revise Applicability of BWR TS 3.6.2.5 and TS 3.6.3.22023-11-29029 November 2023 Application to Revise Technical Specifications to Adopt TSTF-568, Revise Applicability of BWR TS 3.6.2.5 and TS 3.6.3.2 PLA-8091, Response to Request for Additional Information Regarding Proposed Relief Request for the Fifth 10-Year Inseervice Inspection Interval (PLA-8091)2023-11-0808 November 2023 Response to Request for Additional Information Regarding Proposed Relief Request for the Fifth 10-Year Inseervice Inspection Interval (PLA-8091) PLA-8082, Proposed Amendment to Licenses NPF-14 and NPF-22: Application to Revise Technical Specifications to Adopt TSTF-563, Revise Instrument Testing Definitions to Incorporate the Surveillance Frequency Control Program2023-11-0202 November 2023 Proposed Amendment to Licenses NPF-14 and NPF-22: Application to Revise Technical Specifications to Adopt TSTF-563, Revise Instrument Testing Definitions to Incorporate the Surveillance Frequency Control Program PLA-8080, Proposed Relief for Valve 251130 (PLA-8080)2023-08-14014 August 2023 Proposed Relief for Valve 251130 (PLA-8080) PLA-8074, Proposed Relief Request for the Fifth 10-Year Inservice Test Program Interval2023-08-0303 August 2023 Proposed Relief Request for the Fifth 10-Year Inservice Test Program Interval PLA-8076, Unit 2 - 21st Refueling Outage Owner'S Activity Report (PLA-8076)2023-07-20020 July 2023 Unit 2 - 21st Refueling Outage Owner'S Activity Report (PLA-8076) PLA-8078, Submittal of Unit 2 Cycle 22 Core Operating Limits Report, Revision 1, PLA-80782023-07-0505 July 2023 Submittal of Unit 2 Cycle 22 Core Operating Limits Report, Revision 1, PLA-8078 PLA-8054, Proposed Amendment to Licenses NPF-14 and NPF-22: Remove Control Rod Operability Separation Criteria and Replace Reference to Banked Position Withdrawal Sequence with the Analyzed Rod Position Sequence2023-06-0808 June 2023 Proposed Amendment to Licenses NPF-14 and NPF-22: Remove Control Rod Operability Separation Criteria and Replace Reference to Banked Position Withdrawal Sequence with the Analyzed Rod Position Sequence PLA-8073, Proposed Relief Request for the Fifth 10-Year Inservice Inspection Interval2023-06-0101 June 2023 Proposed Relief Request for the Fifth 10-Year Inservice Inspection Interval PLA-8067, Notification of Completion of Emergence from Bankruptcy (PLA-8067)2023-05-17017 May 2023 Notification of Completion of Emergence from Bankruptcy (PLA-8067) PLA-8064, Response to NRC Regulatory Issue Summary 2023-01 (PLA-8064)2023-05-17017 May 2023 Response to NRC Regulatory Issue Summary 2023-01 (PLA-8064) PLA-8066, Notification of Planned Closing Date and Information Identified in March 30, 2023 Order, PLA-80662023-05-0808 May 2023 Notification of Planned Closing Date and Information Identified in March 30, 2023 Order, PLA-8066 PLA-8053, Radiation Exposure Information and Reporting System2023-04-27027 April 2023 Radiation Exposure Information and Reporting System PLA-8058, Annual Radiological Environmental Operating Report (PLA-8058)2023-04-26026 April 2023 Annual Radiological Environmental Operating Report (PLA-8058) PLA-8041, Radioactive Effluent Release Report and Offsite Dose Calculation Manual (PLA-8041)2023-04-25025 April 2023 Radioactive Effluent Release Report and Offsite Dose Calculation Manual (PLA-8041) PLA-8047, 2022 Annual Environmental Operating Report (Nonradiological), PLA-80472023-04-19019 April 2023 2022 Annual Environmental Operating Report (Nonradiological), PLA-8047 PLA-8062, Supplement to Relief Request 4RR-10 Relief from Code Seal Weld Requirement for Valve 252F007B, PLA-80622023-04-11011 April 2023 Supplement to Relief Request 4RR-10 Relief from Code Seal Weld Requirement for Valve 252F007B, PLA-8062 PLA-8061, Relief Request 4RR-10 Relief from Code Seal Weld Requirement for Valve 25F007B, PLA-80612023-04-10010 April 2023 Relief Request 4RR-10 Relief from Code Seal Weld Requirement for Valve 25F007B, PLA-8061 PLA-8060, Submittal of Unit 2 Cycle 22 Core Operating Limits Report (PLA-8060)2023-03-30030 March 2023 Submittal of Unit 2 Cycle 22 Core Operating Limits Report (PLA-8060) PLA-8057, Application for Order Approving Indirect Transfer of Control of Licenses and Approving Conforming License Amendments- Supplemental Information, PLA-80572023-03-15015 March 2023 Application for Order Approving Indirect Transfer of Control of Licenses and Approving Conforming License Amendments- Supplemental Information, PLA-8057 PLA-8052, (Sses), Proof of Financial Protection and Guarantee of Payment of Deferred Premiums2023-02-13013 February 2023 (Sses), Proof of Financial Protection and Guarantee of Payment of Deferred Premiums PLA-8048, Response to Request for Additional Information Regarding License Amendment Requesting Temporary Addition of Analyzed Rod Position Sequence2023-01-14014 January 2023 Response to Request for Additional Information Regarding License Amendment Requesting Temporary Addition of Analyzed Rod Position Sequence PLA-8042, Proposed Emergency Amendment to License NPF-22: Temporary Addition of Analyzed Rod Position Sequence2023-01-10010 January 2023 Proposed Emergency Amendment to License NPF-22: Temporary Addition of Analyzed Rod Position Sequence PLA-8039, Application for Order Approving Indirect Transfer of Control of License Amendments - Supplemental Information2022-12-22022 December 2022 Application for Order Approving Indirect Transfer of Control of License Amendments - Supplemental Information PLA-8038, Notification of Petition for Bankruptcy (PLA-8038)2022-12-14014 December 2022 Notification of Petition for Bankruptcy (PLA-8038) PLA-8036, Registration for the Use of Spent Fuel Storage Casks 203, 202, and 204, PLA-80362022-11-30030 November 2022 Registration for the Use of Spent Fuel Storage Casks 203, 202, and 204, PLA-8036 PLA-8035, Registration for the Use of Spent Fuel Storage Casks 205, 200, and 201, PLA-80352022-11-0808 November 2022 Registration for the Use of Spent Fuel Storage Casks 205, 200, and 201, PLA-8035 PLA-8031, Emergency Plan Revision 66 (PLA-8031)2022-11-0707 November 2022 Emergency Plan Revision 66 (PLA-8031) PLA-8032, Application for Order Approving Indirect Transfer of Control of Licenses and Approving Conforming License Amendments - Supplemental Information (PLA-8032)2022-10-28028 October 2022 Application for Order Approving Indirect Transfer of Control of Licenses and Approving Conforming License Amendments - Supplemental Information (PLA-8032) PLA-8026, Biennial 10 Crf 50.59 and 72.48 Summary Report and Changes to Regulatory Commitment (PLA-8026)2022-10-19019 October 2022 Biennial 10 Crf 50.59 and 72.48 Summary Report and Changes to Regulatory Commitment (PLA-8026) PLA-8015, Application for Order Approving Indirect Transfer of Control of Licenses2022-09-29029 September 2022 Application for Order Approving Indirect Transfer of Control of Licenses PLA-8030, Evacuation Time Estimate Report PLA-80302022-09-15015 September 2022 Evacuation Time Estimate Report PLA-8030 PLA-8025, Supplement to License Amendment to Revise Reactor Steam Dome Pressure - Low Instrumentation Function Allowable Value2022-08-10010 August 2022 Supplement to License Amendment to Revise Reactor Steam Dome Pressure - Low Instrumentation Function Allowable Value PLA-8019, Nd Refueling Outage Owner'S Activity Report, PLA-80192022-07-13013 July 2022 Nd Refueling Outage Owner'S Activity Report, PLA-8019 PLA-8013, Response to Request for Additional Information Regarding License Amendment Requesting Adoption of TSTF-505, Revision 2 PLA-80132022-06-27027 June 2022 Response to Request for Additional Information Regarding License Amendment Requesting Adoption of TSTF-505, Revision 2 PLA-8013 PLA-8012, 10 CFR 50.46 Annual Report2022-06-10010 June 2022 10 CFR 50.46 Annual Report PLA-8005, Response to Request for Additional Information Regarding License Amendment to Revise Reactor Steam Dome Pressure - Low Instrumentation Function Allowable Value (PLA-8005)2022-05-23023 May 2022 Response to Request for Additional Information Regarding License Amendment to Revise Reactor Steam Dome Pressure - Low Instrumentation Function Allowable Value (PLA-8005) PLA-8001, Radiation Exposure Information and Reporting System - PLA-80012022-04-28028 April 2022 Radiation Exposure Information and Reporting System - PLA-8001 PLA-7987, Radioactive Effluent Release Report and Offsite Dose Calculation Manual - (PLA-7987)2022-04-26026 April 2022 Radioactive Effluent Release Report and Offsite Dose Calculation Manual - (PLA-7987) PLA-7986, 2021 Annual Environmental Operating Report (Nonradiological) Docket No. 50-387, PLA-79862022-04-26026 April 2022 2021 Annual Environmental Operating Report (Nonradiological) Docket No. 50-387, PLA-7986 PLA-7985, Annual Radiological Environmental Operating Report2022-04-22022 April 2022 Annual Radiological Environmental Operating Report PLA-7883, Proposed Amendment to Licenses NPF-14 and NPF-22: Relocate Technical Specification Unit Staff Qualification Requirements to Quality Assurance Program (PLA-7883)2022-03-31031 March 2022 Proposed Amendment to Licenses NPF-14 and NPF-22: Relocate Technical Specification Unit Staff Qualification Requirements to Quality Assurance Program (PLA-7883) PLA-7995, Property Insurance Program (PLA-7995)2022-03-30030 March 2022 Property Insurance Program (PLA-7995) PLA-7998, Submittal of Unit 1 Cycle 23 Core Operating Limits Report and Reload Safety Analysis Report2022-03-29029 March 2022 Submittal of Unit 1 Cycle 23 Core Operating Limits Report and Reload Safety Analysis Report PLA-7991, Proof of Financial Protection and Guarantee of Payment of Deferred Premium2022-03-24024 March 2022 Proof of Financial Protection and Guarantee of Payment of Deferred Premium PLA-7984, Supplement to License Amendment Requesting Adoption of TSTF-505, Revision 22022-03-0808 March 2022 Supplement to License Amendment Requesting Adoption of TSTF-505, Revision 2 PLA-7962, Application to Revise Technical Specifications to Adopt TSTF-564, Safety Limit MCPR PLA-79622022-01-0505 January 2022 Application to Revise Technical Specifications to Adopt TSTF-564, Safety Limit MCPR PLA-7962 2024-01-04
[Table view] Category:Technical Specifications
MONTHYEARPLA-8084, Application to Revise Technical Specifications to Adopt TSTF-568, Revise Applicability of BWR TS 3.6.2.5 and TS 3.6.3.22023-11-29029 November 2023 Application to Revise Technical Specifications to Adopt TSTF-568, Revise Applicability of BWR TS 3.6.2.5 and TS 3.6.3.2 ML23195A1852023-07-27027 July 2023 Correction to Technical Specifications Page 3.3-73 in Amendment No. 265 ML23132A3212023-05-17017 May 2023 Associated Independent Spent Fuel Storage Installation - Issuance of Amendment Nos. 285 and 269 Related to Order Approving Transfer of Licenses ML23010A1082023-01-15015 January 2023 Issuance of Amendment No. 268 Change to Control Rod Technical Specifications PLA-8042, Proposed Emergency Amendment to License NPF-22: Temporary Addition of Analyzed Rod Position Sequence2023-01-10010 January 2023 Proposed Emergency Amendment to License NPF-22: Temporary Addition of Analyzed Rod Position Sequence ML22294A1502022-11-17017 November 2022 Issuance of Amendment Nos. 284 and 267 Relocating Technical Specification Unit Staff Qualification Requirements to Quality Assurance Program ML22146A2072022-07-15015 July 2022 Issuance of Amendment Nos. 281 and 264 Revise Technical Specifications to Adopt TSTF-564, Safety Limit MCPR - NON-PROPRIETARY - ML22101A0282022-03-30030 March 2022 Revised Technical Specification Bases Unit 1 Manual ML20342A2372021-02-18018 February 2021 Issuance of Amendment Nos. 279 and 261 Revise Technical Specifications to Adopt TSTF-582, RPV WIC Enhancements ML20297A5642020-12-22022 December 2020 Issuance of Amendment Nos. 277 and 259 Revise Technical Specifications to Adopt TSTF-529, Revision 4, Clarify Use and Application Rules PLA-7866, Electric Station Proposed Amendment Licenses NPF-14 and - NPF-22: Application to Revise Technical Specifications to Adopt TSTF-529, Clarify Use and Application Rules PLA-78662020-06-25025 June 2020 Electric Station Proposed Amendment Licenses NPF-14 and - NPF-22: Application to Revise Technical Specifications to Adopt TSTF-529, Clarify Use and Application Rules PLA-7866 ML19248A8442020-01-17017 January 2020 Issuance of Amendment Nos. 275 and 257 Temporary Changes to Allow Replacement of Emergency Service Water System Piping ML19232A0692019-08-0808 August 2019 Technical Specification Bases Unit 2 Manual ML19232A0682019-08-0808 August 2019 Technical Specification Bases Manual ML19155A2642019-07-16016 July 2019 Issuance of Amendment Nos. 273 and 255 Adoption of TSTF-439, Revision 2, Eliminate Second Completion Times Limiting Time from Discovery of Failure to Meet an LCO ML19154A0602019-06-24024 June 2019 Issuance of Amendment Nos. 272 and 254 Technical Specifications to Adopt TSTF-501, Revision 1, Relocated Stored Fuel Oil and Lube Oil Volume Values to Licensee Control ML19052A0082019-03-0505 March 2019 Correction to Technical Specifications Page 3.3-45 (Unit 1) and Page 3.6-11 (Unit 2) for Administrative Errors Introduced During the Issuance of Amendment Nos. 271 and 253 ML18222A2032018-09-26026 September 2018 Issuance of Amendment Nos. 271 and 253 Revising Technical Specifications to Adopt TSTF-542, Revision 2 (CAC Nos. MG0269 and MG0270; EPID L-2017-LLA-0306) PLA-7733, Correction of Technical Specification Typographical Error for TS 3.6.4.1 (PLA-7733)2018-09-11011 September 2018 Correction of Technical Specification Typographical Error for TS 3.6.4.1 (PLA-7733) ML18017A2272017-12-15015 December 2017 Technical Specification Bases Manual ML18017A2282017-12-15015 December 2017 Technical Specifications Bases Manual ML17221A2892017-08-0909 August 2017 Draft TSTF-542-Variations ML17187A2972017-07-28028 July 2017 Susquehanna Steam Electric Station, Units 1 and 2 - Issuance of Amendments Revising Technical Specifications to Adopt TSTF-522, Revision 0 (CAC Nos. MF9154 and MF9155) PLA-7605, Change to Submittal Regarding License Amendment Request for Adoption of Technical Specification Task Force Traveler TSTF-522-A2017-05-17017 May 2017 Change to Submittal Regarding License Amendment Request for Adoption of Technical Specification Task Force Traveler TSTF-522-A ML17067A4442017-03-27027 March 2017 Issuance of Amendments Secondary Containment Access Openings ML16005A2342016-05-20020 May 2016 Issuance of Amendments Adoption of TSTF-425 ML16062A2162016-03-28028 March 2016 Issuance of Amendments Emergency Action Level Scheme Change PLA-7441, Supplemental Information on Technical Specification Changes to Adopt Traveler TSTF-4252016-01-29029 January 2016 Supplemental Information on Technical Specification Changes to Adopt Traveler TSTF-425 PLA-7406, Response to Request for Additional Information on Technical Specification Changes to Adopt Traveler TSTF-4252015-11-11011 November 2015 Response to Request for Additional Information on Technical Specification Changes to Adopt Traveler TSTF-425 ML15267A3812015-11-0202 November 2015 Issuance of Amendments Approval of Cyber Security Plan Milestone 8 ML15243A1402015-09-30030 September 2015 Issuance of Amendments Revisions to Technical Specification 3.4.10, Reactor Coolant System Pressure and Temperature (P/T) Limits PLA-7334, Response to Request for Additional Information on Technical Specification Changes to Adopt Traveler TSTF-4252015-07-0202 July 2015 Response to Request for Additional Information on Technical Specification Changes to Adopt Traveler TSTF-425 PLA-7299, Response to Request for Additional Information on Technical Specification Changes to RCS Pressure and Temperature (P/T) Limits2015-04-0606 April 2015 Response to Request for Additional Information on Technical Specification Changes to RCS Pressure and Temperature (P/T) Limits PLA-7119, PPL Susquehanna, LLC, Unit 1 & Unit 2 Proposed Technical Specification Amendment for Adoption of Task Force Traveler TSTF-425, Rev. 3, Relocate Surveillance Frequencies to Licensee Control Risk Informed Technical Specification Task Force...2014-10-27027 October 2014 PPL Susquehanna, LLC, Unit 1 & Unit 2 Proposed Technical Specification Amendment for Adoption of Task Force Traveler TSTF-425, Rev. 3, Relocate Surveillance Frequencies to Licensee Control Risk Informed Technical Specification Task Force... ML14316A6062014-10-27027 October 2014 PPL Susquehanna, LLC, Unit 1 & Unit 2 Proposed Technical Specification Amendment for Adoption of Task Force Traveler TSTF-425, Rev. 3, Relocate Surveillance Frequencies to Licensee Control Risk Informed Technical Specification Task Force... ML14111A0522014-05-14014 May 2014 Issuance of Amendments Regarding Change to Technical Specification Surveillance Requirement 3.5.1.12 ML14036A2572014-02-26026 February 2014 Issuance of Amendment Change to Allow Only One Manual Trip System to Be Operable for the Residual Heat Removal Shutdown Cooling System in Modes 4 and 5 ML14042A1152014-01-29029 January 2014 License Amendment Request - Increase of the Allowable Gas Treatment System Maximum Flow Rates from Secondary Containment ML13361A0872013-12-11011 December 2013 Revision 112 to Technical Specification Bases Manual PLA-6825, Proposed Amendment No. 310 to License NPF-14 and Proposed Amendment No. 282 to License NPF-22: Change to Tech Spec SR 3.8.1.9, 3.8.1.11, 3.8.1.12, and 3.8.1.19 to Increase Diesel Generator Minimum Steady State Voltage2012-09-18018 September 2012 Proposed Amendment No. 310 to License NPF-14 and Proposed Amendment No. 282 to License NPF-22: Change to Tech Spec SR 3.8.1.9, 3.8.1.11, 3.8.1.12, and 3.8.1.19 to Increase Diesel Generator Minimum Steady State Voltage ML11221A2712011-09-0808 September 2011 License Amendment, Issuance of Amendment Adoption of TSTF-514, Revision 3 ML11251A1532011-08-24024 August 2011 Technical Requirements Manual, Rev. 69 and Table of Contents, Rev. 20 ML11251A1522011-08-24024 August 2011 Revision 68 to Technical Requirements Manual PLA-6642, Proposed Amendment Nos. 307 & 278, Change to Technical Specification Surveillance Requirement (SR) 3.4.3.1 to Revise the Lower Surveillance Tolerances2010-11-10010 November 2010 Proposed Amendment Nos. 307 & 278, Change to Technical Specification Surveillance Requirement (SR) 3.4.3.1 to Revise the Lower Surveillance Tolerances ML1020103852010-07-12012 July 2010 Revision 100 to Technical Specifications Bases Unit 2 Manual ML1020104112010-07-12012 July 2010 Revisions to Technical Specification Bases Manual ML1012605332010-04-28028 April 2010 Technical Specification Bases Manual ML1011003942010-04-0606 April 2010 Technical Specifications Bases Unit 2 Manual, Rev. 98 ML0932901772009-11-24024 November 2009 Technical Specifications for Susquehanna Steam Electric Station, Unit 2 ML0929501102009-11-0909 November 2009 License Amendment, Changed Technical Specification Table 3.3.5.1-1 for ECCS Instrumentation for CST and Editorial Changes to TS 3.10.8.f 2023-07-27
[Table view] |
Text
Brad Berryman Susquehanna Nuclear, LLC TALEN~
Site Vice President 769 Salem Boulevard Berwick, PA 18603 SEP 1 1 2018 Tel. 570.542.2904 Fax 570.542.1504 Brad.Berryman@TalenEnergy.com ENERGY U.S. Nuclear Regulatory Commission 10 CPR 50.4 Attn: Document Control Desk Washington, DC 20555-0001 SUSQUEHANNA STEAM ELECTRIC STATION CORRECTION OF TECHNICAL SPECIFICATION TYPOGRAPHICAL ERROR FORTS 3.6.4.1 Docket No. 50-387 PLA-7733 and No. 50-388
References:
- 1) Letterji*om J A Whited, NRC, to J A. Franke, Talen, "Susquehanna Steam Electric Station, Units 1 and 2- Issuance ofAmendments RE: Adoption ofTSTF-425 (CAC Nos. MF5151 and MF5152), "dated May 20,2016, ADAMS Accession Number ML16005A234.
- 2) Proposed Guidance for Correction ofTechnical Specification Typographical Errors, SECY 238, dated November 19, 1996.
Susquehanna Nuclear, LLC is requesting correction for an inadvertent typographical error in Susquehanna Steam Electric Station (SSES) Unit I and Unit 2 Technical Specification (TS) 3.6.4.1, Secondmy Containment. This error was introduced into the SSES Unit 1 and Unit 2 TS under Operating License NPF-14 Amendment 266 and Operating License NPF-22 Amendment 247, respectively (Reference 1). This letter requests the U.S. Nuclear Regulatory Commission's (NRC) approval of a correction to a typographical error.
This typographical error was not addressed in the notice to the public, not reviewed by the NRC, and falls within the scope of guidance provided in SECY-96-238 for correction (Reference 2). of this letter describes the typographical error and required correction. Enclosures 2 and 3 provide the marked-up TS pages with the correction to the typographical error. Enclosures 4 and 5 provide the clean copies of the TS pages.
This letter contains no new regulatory commitments. Should you have any questions regarding this submittal, please contact Mr. Jason Jennings, Manager- Nuclear Regulatory Affairs at (570) 542-3155.
Document Control Desk PLA-7733 : Description of SSES Technical Specification Typographical Error : SSES Unit 1 TS 3.6.4.1 - Secondary Containment, Mark-up : SSES Unit 2 TS 3.6.4.1 - Secondary Containment, Mark-up : SSES Unit 1 TS 3.6.4.1 - Secondary Containment, Clean Copy : SSES Unit 2 TS 3.6.4.1 - Secondary Containment, Clean Copy Copy: NRC Region I Ms. T. E. Hood, NRC Project Manager Ms. L. H. Micewski, NRC Sr. Resident Inspector Mr. M. Shields, PA DEP/BRP
Enclosure 1:
Description of SSES Technical Specification Typographical Error
PLA-7733 - Enclosure 1 Page 1 of 3 Description of Technical Specification Typographical Error
- 1. Requested Action Consistent with the information contained in SECY-96-238, Proposed Guidance for Correction of Technical Specification Typographical Errors (Reference 12), Susquehanna Nuclear, LLC is requesting correction for an inadvertent typographical error in Susquehanna Steam Electric Station (SSES) Unit 1 and Unit 2 Technical Specification (TS) 3.6.4.1, Secondary Containment. This error was introduced into the SSES Unit 1 and Unit 2 TS under Amendment 266 and Amendment 247 (Reference 6), respectively. These errors remained uncorrected in Operating License NPF-14 Amendment 267 (Reference 9) and Amendment 270 (Reference 11), and Operating License NPF-22 Amendment 249 (Reference 9) and Amendment 252 (Reference 11).
- 2. Typographical Error The typographical error was introduced into the SSES Unit 1 and Unit 2 TS during implementation of the Operating License NPF-14 Amendment 266 and Operating License NPF-22 Amendment 247 (Reference 6). The following describes the specific errors and corrections.
Error Location: Unit 1 TS page TS / 3.6-37 and Unit 2 TS page TS / 3.6-37 SSES submitted a License Amendment Request to the NRC to adopt TSTF-425 which would modify the TS by relocating specific surveillance frequencies to a licensee-controlled program (References 1 through 5). This request, in part, resulted in Unit 1 and Unit 2 TS 3.6.4.1 replacing the specified frequency of Surveillance Requirement (SR) 3.6.4.1.4 and 3.6.4.1.5 with In accordance with the Surveillance Frequency Control Program. During the mark-up process for the TS change, the removal of the frequency notes associated with SR 3.6.4.1.4 and 3.6.4.1.5 was missed. Each frequency note states to Test each configuration at least one time every 60 months. Contrary to the intent of TSTF-425, these frequency notes restrict the licensee from independently managing the frequency of the associated surveillance.
SR 3.6.4.1.4 and 3.6.4.1.5 frequency notes should be deleted resulting in the SR frequency being fully managed by the licensee-maintained Surveillance Frequency Control Program as approved by the NRC for SSES (Reference 6).
This error was not noticed by the public nor approved by the NRC during review and approval of Operating License NPF-14 Amendments 266, 267, and 270 and Operating License NPF-22 Amendments 247, 249, and 252. Enclosures 2 and 3 provide the marked-up TS pages with the correction to the typographical error. Enclosures 4 and 5 provide the clean copies of the TS pages.
- 3. Applicability of SECY 96-238 SECY 96-238 (SECY) (Reference 12) provides guidance to correct inadvertent typographical errors in the TS pages. The SECY allows for the use of an administrative letter to correct a typographical error upon meeting two requirements: 1) the error must have occurred in a specific license amendment; and 2) the error was not reviewed as part of the license amendment.
PLA-7733 - Enclosure 1 Page 2 of 3 SSES has determined that the errors in Unit 1 and Unit 2 TS 3.6.4.1 were introduced under Amendment 266 and Amendment 247, respectively. These errors remained uncorrected in Operating License NPF-14 Amendment 267 and Amendment 270, and Operating License NPF-22 Amendment 249 and Amendment 252. Therefore, the first requirement is met.
When Operating License NPF-14 Amendment 266 and Operating License NPF-22 Amendment 247 were submitted for approval, the changes identified for the adoption of TSTF-425 did not identify any required change to the SR 3.6.4.1.4 and 3.6.4.1.5 frequency notes. These errors remained unidentified in Operating License NPF-14 Amendment 267 and Amendment 270, and Operating License NPF-22 Amendment 249 and Amendment 252. As such, the required change to the SR 3.6.4.1.4 and 3.6.4.1.5 frequency notes was not the subject of NRC review in the License Amendment Requests submitted under References 1 through 5, 7, 8, and 10.
Based on meeting both requirements for SECY 96-238, the use of this administrative letter to correct the identified typographical error in SSES Units 1 and 2 TS 3.6.4.1 is appropriate.
- 4. References
- 1) PPL Letter (PLA-7119), Susquehanna Steam Electric Station Amendment Request No. 315 to License NPF-14 and Amendment Request No. 287 to License No. NPF-22: Adoption of Technical Specification Task Force Traveler TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control--Risk Informed Technical Specification Task Force (RITSTF)
Initiative 5, dated October 27, 2014, ADAMS Accession Number ML14317A052.
- 2) Talen Letter (PLA-7334), Susquehanna Steam Electric Station Response to Request for Additional Information on Technical Specification Changes to Adopt Traveler TSTF-425, dated July 02, 2015, ADAMS Accession Number ML15183A248.
- 3) Talen Letter (PLA-7381), Susquehanna Steam Electric Station Response to Request for Additional Information on Technical Specification Changes to Adopt Traveler TSTF-425, dated September 21, 2015, ADAMS Accession Number ML15265A347.
- 4) Talen Letter (PLA-7406), Susquehanna Steam Electric Station Response to Request for Additional Information on Technical Specification Changes to Adopt Traveler TSTF-425, dated November 11, 2015, ADAMS Accession Number ML15315A045.
- 5) Talen Letter (PLA-7441), Susquehanna Steam Electric Station Supplemental Information on Technical Specification Changes to Adopt Traveler TSTF-425, dated January 29, 2016, ADAMS Accession Number ML16032A324.
- 6) Letter from J. A. Whited, NRC, to J. A. Franke, Talen, Susquehanna Steam Electric Station, Units 1 and 2- Issuance of Amendments RE: Adoption of TSTF-425 (CAC Nos. MF5151 and MF5152), dated May 20, 2016, ADAMS Accession Number ML16005A234.
- 7) Talen Letter (PLA-7486), Susquehanna Steam Electric Station Proposed Amendment Request to Address Secondary Containment Access Openings, dated July 27, 2016, ADAMS Accession Number ML16210A001.
PLA-7733 - Enclosure 1 Page 3 of 3
- 8) Talen Letter (PLA-7528), Susquehanna Steam Electric Station Supplemental Information for License Amendment Request to Address Secondary Containment Access Openings, dated September 13, 2016, ADAMS Accession Number ML16257A598.
- 9) Letter from T. E. Hood, NRC, to B. Berryman, Talen, Susquehanna Steam Electric Station, Units 1 and 2- Issuance of Amendments RE: Secondary Containment Access Openings (CAC Nos. MF8214 and MF8215), dated March 27, 2017, ADAMS Accession Number ML17067A444.
- 10) Talen Letter (PLA-7644), Susquehanna Steam Electric Station Proposed Amendments to Revise Technical Specifications to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements, dated December 14, 2017, ADAMS Accession Number ML17348B097.
- 11) Letter from T. E. Hood, NRC, to B. Berryman, Talen, Susquehanna Steam Electric Station, Units 1 and 2- Issuance of Amendments Nos. 270 and 252 RE: Technical Specifications to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements (EPID L-2017-LLA-0410), dated June 26, 2018, ADAMS Accession Number ML18150A281.
- 12) Proposed Guidance for Correction of Technical Specification Typographical Errors, SECY-96-238, dated November 19, 1996, ADAMS Accession Number 9611250030.
Enclosure 2:
SSES Unit 1 TS 3.6.4.1- Secondary Containment, Mark-up
Secondary Containment 3.6.4.1 SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE FREQUENCY SR 3.6.4.1.3 Verify one secondary containment access door in In accordance with the each access opening is closed, except when the Surveillance Frequency access opening is being used for entry and exit. Control Program SR 3.6.4.1.4 -----------------------------NOTE----------------------------- ---------------NOTE----------------
The maximum time allowed for secondary Test each configuration at containment draw down is dependent on the least one time every 60 secondary containment configuration. months.
Verify each SGT subsystem will draw down the In accordance with the secondary containment to 0.25 inch of vacuum Surveillance Frequency water gauge in less than or equal to the maximum Control Program time allowed for the secondary containment configuration that is OPERABLE.
SR 3.6.4.1.5 -----------------------------NOTE---------------------------- ---------------NOTE----------------
The maximum flow allowed for maintaining Test each configuration at secondary containment vacuum is dependent on least one time every 60 the secondary containment configuration. months.
Verify each SGT subsystem can maintain In accordance with the 0.25 inch of vacuum water gauge in the Surveillance Frequency secondary containment for at least 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at a flow Control Program rate less than or equal to the maximum flow rate permitted for the secondary containment configuration that is OPERABLE.
SUSQUEHANNA - UNIT 1 TS / 3.6-37 Amendment 178, 226, 229, 266, 267, 270
Enclosure 3:
SSES Unit 2 TS 3.6.4.1- Secondary Containment, Mark-up
Secondary Containment 3.6.4.1 SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE FREQUENCY SR 3.6.4.1.3 Verify one secondary containment access door in In accordance with the each access opening is closed, except when the Surveillance Frequency access opening is being used for entry and exit. Control Program SR 3.6.4.1.4 -----------------------------NOTE----------------------------- ---------------NOTE---------------
The maximum time allowed for secondary Test each configuration at containment draw down is dependent on the least one time every 60 secondary containment configuration. months.
Verify each SGT subsystem will draw down the In accordance with the secondary containment to 0.25 inch of vacuum Surveillance Frequency water gauge in less than or equal to the maximum Control Program time allowed for the secondary containment configuration that is OPERABLE.
SR 3.6.4.1.5 -----------------------------NOTE---------------------------- ---------------NOTE---------------
The maximum flow allowed for maintaining Test each configuration at secondary containment vacuum is dependent on least one time every 60 the secondary containment configuration. months.
Verify each SGT subsystem can maintain In accordance with the 0.25 inch of vacuum water gauge in the Surveillance Frequency secondary containment for at least 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at a flow Control Program rate less than or equal to the maximum flow rate permitted for the secondary containment configuration that is OPERABLE.
SUSQUEHANNA - UNIT 2 TS / 3.6-37 Amendment 151, 203, 205, 247, 249, 252
Enclosure 4:
SSES Unit 1 TS 3.6.4.1- Secondary Containment, Clean Copy
Secondary Containment 3.6.4.1 SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE FREQUENCY SR 3.6.4.1.3 Verify one secondary containment access door in In accordance with the each access opening is closed, except when the Surveillance Frequency access opening is being used for entry and exit. Control Program SR 3.6.4.1.4 -----------------------------NOTE-----------------------------
The maximum time allowed for secondary containment draw down is dependent on the secondary containment configuration.
Verify each SGT subsystem will draw down the In accordance with the secondary containment to 0.25 inch of vacuum Surveillance Frequency water gauge in less than or equal to the maximum Control Program time allowed for the secondary containment configuration that is OPERABLE.
SR 3.6.4.1.5 -----------------------------NOTE----------------------------
The maximum flow allowed for maintaining secondary containment vacuum is dependent on the secondary containment configuration.
Verify each SGT subsystem can maintain In accordance with the 0.25 inch of vacuum water gauge in the Surveillance Frequency secondary containment for at least 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at a flow Control Program rate less than or equal to the maximum flow rate permitted for the secondary containment configuration that is OPERABLE.
SUSQUEHANNA - UNIT 1 TS / 3.6-37 Amendment 178, 226, 229, 266, 267, 270
Enclosure 5:
SSES Unit 2 TS 3.6.4.1- Secondary Containment, Clean Copy
Secondary Containment 3.6.4.1 SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE FREQUENCY SR 3.6.4.1.3 Verify one secondary containment access door in In accordance with the each access opening is closed, except when the Surveillance Frequency access opening is being used for entry and exit. Control Program SR 3.6.4.1.4 -----------------------------NOTE-----------------------------
The maximum time allowed for secondary containment draw down is dependent on the secondary containment configuration.
Verify each SGT subsystem will draw down the In accordance with the secondary containment to 0.25 inch of vacuum Surveillance Frequency water gauge in less than or equal to the maximum Control Program time allowed for the secondary containment configuration that is OPERABLE.
SR 3.6.4.1.5 -----------------------------NOTE----------------------------
The maximum flow allowed for maintaining secondary containment vacuum is dependent on the secondary containment configuration.
Verify each SGT subsystem can maintain In accordance with the 0.25 inch of vacuum water gauge in the Surveillance Frequency secondary containment for at least 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at a flow Control Program rate less than or equal to the maximum flow rate permitted for the secondary containment configuration that is OPERABLE.
SUSQUEHANNA - UNIT 2 TS / 3.6-37 Amendment 151, 203, 205, 247, 249, 252