ML101100394
| ML101100394 | |
| Person / Time | |
|---|---|
| Site: | Saint Lucie, Susquehanna |
| Issue date: | 04/06/2010 |
| From: | Susquehanna |
| To: | Gerlach R Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| Download: ML101100394 (29) | |
Text
Apr.
06, 2010 Page 1
of 2
MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2010-15011 USER INFORMATION:
GERLACH*ROSE M EMPL#:028401 CA#:
0363 Address: NUCSA2 Phone#:
254-3194 TRANSMITTAL INFORMATION:
TO:
GERLACH*ROSE M 04/06/2010 LOCATION:
USNRC FROM:
NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)
THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU.
HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ON THIS TRANSMITTAL.
WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANUAL, ENSURE THE UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID YOU'RE REMOVING FROM YOUR MANUAL.
TOOLS FROM THE HUMAN PERFORMANCE TOOL BAG SHOULD BE UTILIZED TO ELIMINATE THE CHANCE OF ERRORS.
ATTENTION:
"REPLACE" directions do not affect the Table of Contents, Therefore no TOC will be issued with the updated material.
TSB2 TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL REMOVE MANUAL TABLE OF CONTENTS DATE: 03/21/2010 ADD MANUAL TABLE OF CONTENTS DATE: 04/05/2010 CATEGORY:
DOCUMENTS TYPE: TSB2 A~DI
(,\\A(etL
Apr.
06, 2010 Page 2
of 2
ID:
TEXT 3.7.1 ADD:
REV: 4 REMOVE:
REV:3 CATEGORY:
DOCUMENTS TYPE: TSB2 ID:
TEXT LOES ADD:
REV:
98 REMOVE:
REV:97 ANY DISCREPANCIES WITH THE MATERIAL PROVIDED, CONTACT DCS @ X3107 OR X3136 FOR ASSISTANCE.
UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 3 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.
PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES.
FOR ELECTRONIC MANUAL
- USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.
SSES MA.NUAL Manual Name:
TSB2 Manual
Title:
TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL Table Of Contents Issue Date:
04/05/2010 Procedure Name Rev TEXT LOES 98
Title:
LIST OF EFFECTIVE SECTIONS Issue Date 04/05/2010 Change ID Change Number TEXT TOC
Title:
TABLE OF CONTENTS 16 03/10/2010 TEXT 2.1.1 4
Title:
SAFETY LIMITS (SLS)
REACTOR TEXT 2.1.2 1
Title:
SAFETY LIMITS (SLS)
REACTOR 05/06/2009 CORE SLS 10/04/2007 COOLANT SYSTEM (RCS)
PRESSURE SL TEXT 3.0
Title:
LIMITING CONDITION 3
08/20/2009 FOR OPERATION (LCO) APPLICABILITY TEXT 3.1.1
Title:
REACTIVITY TEXT 3.1.2
Title:
REACTIVITY TEXT 3.1.3
Title:
REACTIVITY TEXT 3.1.4
Title:
REACTIVITY TEXT 3.1.5
Title:
REACTIVITY TEXT 3.1.6
Title:
REACTIVITY CONTROL SYSTEMS 0
CONTROL SYSTEMS 2
CONTROL SYSTEMS 4
CONTROL SYSTEMS 1
CONTROL SYSTEMS 03/24/2005 SHUTDOWN MARGIN (SDM) 11/18/2002 REACTIVITY ANOMALIES 01/19/2009 CONTROL ROD OPERABILITY 01/30/2009 CONTROL ROD SCRAM TIMES 07/06/2005 CONTROL ROD SCRAM ACCUMULATORS 2
03/24/2005 CONTROL SYSTEMS ROD PATTERN CONTROL Pagel of
- ~
Report Date: 04/05/10 Page I of a Report Date: 04/05/10
SSES MANUJAL Manual Name:
TSB2 4
Manual
Title:
TECHNICAL SPECIFICATIONS-BASES UNIT 2 MANUAL TEXT 3.1.7 3
10/04/2007
Title:
REACTIVITY CONTROL SYSTEMS STANDBY LIQUID CONTROL (SLC)
SYSTEM TEXT 3.1.8 3
05/06/2009
Title:
REACTIVITY CONTROL SYSTEMS SCRAM DISCHARGE VOLUME (SDV)
VENT AND DRAIN VALVES TEXT 3.2.1 4
05/06/2009
Title:
POWER DISTRIBUTION LIMITS AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)
TEXT 3.2.2 3
05/06/2009
Title:
POWER DISTRIBUTION LIMITS MINIMUM CRITICAL POWER RATIO (MCPR)
TEXT 3.2.3 2
05/06/2009
Title:
POWER DISTRIBUTION LIMITS LINEAR.HEAT GENERATION RATE LHGR 4
TEXT 3.3.1.1 4
05/06/2009
Title:
INSTRUMENTATION REACTOR PROTECTION SYSTEM (RPS)
INSTRUMENTATION TEXT 3.3.1.2
Title:
INSTRUMENTATION TEXT 3.3.2.1
Title:
INSTRUMENTATION 2
01/19/2009 SOURCE RANGE MONITOR (SRM)
INSTRUMENTATION 2
04/09/2007 CONTROL ROD BLOCK INSTRUMENTATION TEXT 3.3.2.2 1
05/06/2009
Title:
INSTRUMENTATION FEEDWATER -
MAIN TURBINE HIGH WATER LEVEL TRIP INSTRUMENTATION TEXT 3.3.3.1
Title:
INSTRUMENTATION 7
10/27/2008 POST ACCIDENT MONITORING (PAM)
INSTRUMENTATION TEXT 3.3.3.2 1
04/18/2005
Title:
INSTRUMENTATION REMOTE SHUTDOWN SYSTEM TEXT 3.3.4.1
Title:
INSTRUMENTATION 1
05/06/2009 END OF CYCLE RECIRCULATION PUMP TRIP (EOC-RPT)
INSTRUMENTATION PageZ of 8 Report Date: 04/05/10 Page 2 of 8
Report Date: 04/05/10
SSES MANUAL Manual Name:
TSB2 Manual
Title:
TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL TEXT 3.3.4.2 0
11/18/2002
Title:
INSTRUMENTATION ANTICIPATED TRANSIENT WITHOUT SCRAM RECIRCULATION PUMP TRIP (ATWS-RPT)
INSTRUMENTATION TEXT 3.3.5.1 4
08/20/2009
Title:
INSTRUMENTATION EMERGENCY CORE COOLING SYSTEM -(ECCS)
INSTRUMENTATION."
TEXT 3.3.5.2 0
11/18/2002
Title:
INSTRUMENTATION REACTOR CORE ISOLATION COOLING (RCIC)
SYSTEM INSTRUMENTATION TEXT 3.3.6.1 4
05/06/2009
Title:
INSTRUMENTATION PRIMARY CONTAINMENT ISOLATION INSTRUMENTATION TEXT 3.3.6.2 3
10/27/2008
Title:
INSTRUMENTATION SECONDARY CONTAINMENT ISOLATION INSTRUMENTATION TEXT 3.3.7.1
Title:
INSTRUMENTATION INSTRUMENTATION 2
10/27/2008 CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS)
SYSTEM TEXT 3.3.8.1 3
12/17/2007
Title:
INSTRUMENTATION LOSS OF POWER (LOP)
INSTRUMENTATION TEXT 3.3.8.2 0
11/18/2002
Title:
INSTRUMENTATION REACTOR PROTECTION SYSTEM (RPS)
ELECTRIC POWER MONITORING TEXT 3.4.1 3
04/09/2007
Title:
RECIRCULATION LOOPS OPERATING TEXT 3.4.2 1
05/06/2009
Title:
JET PUMPS TEXT 3.4.3 2
05/06/2009
Title:
SAFETY/RELIEF VALVES (S/RVS)
TEXT 3.4.4 0
11/18/2002
Title:
RCS OPERATIONAL LEAKAGE Page 3 of8 Report Date: 04/05/10
SSES MANUJAL Manual Name:
TSB2 Manual
Title:
TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL TEXT 3.4.5 3
03/10/2010
Title:
RCS PRESSURE ISOLATION VALVE (PIV) LEAKAGE TEXT 3.4.6 2
08/20/2009
Title:
RCS LEAKAGE DETECTION INSTRUMENTATION TEXT 3.4.7 2
10/04/2007
Title:
RCS SPECIFIC ACTIVITY TEXT 3.4.8
Title:
REACTOR COOLANT HOT SHUTDOWN TEXT 3.4.9
Title:
REACTOR COOLANT COLD SHUTDOWN TEXT 3.4.10
Title:
REACTOR COOLANT TEXT 3.4.11
Title:
REACTOR COOLANT TEXT 3.5.1 1
SYSTEM (RCS) 0 SYSTEM-(RCS) 04/18/2005 RESIDUAL HEAT REMOVAL (RHR)
SHUTDOWN COOLING SYSTEM 11/18/2002 RESIDUAL HEAT REMOVAL (RHR)
SHUTDOWN COOLING SYSTEM0 3
05/06/2009 SYSTEM (RCS)
RCS PRESSURE AND TEMPERATURE (P/T) LIMITS 0
11/18/2002 SYSTEM (RCS)
REACTOR STEAM DOME PRESSURE 3
01/16/2006 Title,: EMERGENCY CORE COOLING SYSTEMS (ECCS)
AND REACTOR SYSTEM ECCS -
OPERATING TEXT 3.5.2 0
11/18/2002
Title:
EMERGENCY CORE COOLING SYSTEMS (ECCS)
AND REACTOR SYSTEM ECCS -
SHUTDOWN TEXT 3.5.3 1
04/18/2005
Title:
EMERGENCY CORE COOLING SYSTEMS (ECCS)
AND REACTOR SYSTEM RCIC SYSTEM TEXT 3.6.1.1 3
05/06/2009
Title:
CONTAINMENT SYSTEMS PRIMARY CONTAINMENT TEXT 3.6.1.2 1
05/06/2009
Title:
CONTAINMENT SYSTEMS PRIMARY CONTAINMENT AIR LOCK CORE ISOLATION COOLING (RCIC)
CORE ISOLATION COOLING (RCIC)
CORE ISOLATION COOLING (RCIC)
Page4 of 8
Report Date: 04/05/10 Page 4 of 8
Report Date: 04/05/10
SSES MANUAL Manual Name:
TSB2 Manual
Title:
TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL TEXT 3.6.1.3 10 03/10/2010
Title:
CONTAINMENT SYSTEMS PRIMARY CONTAINMENT ISOLATION VALVES (PCIVS)
LDCN 4684 TEXT 3.6.1.4 1
05/06/2009
Title:
CONTAINMENT SYSTEMS CONTAINMENT PRESSURE TEXT 3.6.1.5 1
10/05/2005
Title:
CONTAINMENT SYSTEMS DRYWELL AIR TEMPERATURE TEXT 3.6.1.6 0
11/18/2002
Title:
CONTAINMENT SYSTEMS SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKERS TEXT 3.6.2.1 2
12/17/2007
Title:
CONTAINMENT SYSTEMS SUPPRESSION POOL AVERAGE TEMPERATURE I
TEXT 3.6.2.2 0
11/18/2002
Title:
CONTAINMENT SYSTEMS SUPPRESSION POOL WATER LEVEL TEXT 3.6.2.3 1
01/16/2006
Title:
CONTAINMENT SYSTEMS RESIDUAL HEAT REMOVAL (RHR)
SUPPRESSION POOL COOLING TEXT 3.6.2.4 0
11/18/2002
Title:
CONTAINMENT SYSTEMS RESIDUAL HEAT REMOVAL (RHR)'SUPPRESSION POOL SPRAY TEXT 3.6.3.1 2
06/13/2006
Title:
CONTAINMENT SYSTEMS PRIMARY CONTAINMENT HYDROGEN RECOMBINERS TEXT 3.6.3.2 1
04/18/2005
Title:
CONTAINMENT SYSTEMS DRYWELL AIR FLOW SYSTEM TEXT 3.6.3.3 0
11/18/2002
Title:
CONTAINMENT SYSTEMS PRIMARY CONTAINMENT OXYGEN CONCENTRATION TEXT 3.6.4.1 7
10/04/2007
Title:
CONTAINMENT SYSTEMS SECONDARY CONTAINMENT Page 5 of8 Report Date: 04/05/10
SSES MANUAL Manual Name:
TSB2 Manual
Title:
TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL TEXT 3.6.4.2 3
03/10/2010
Title:
CONTAINMENT SYSTEMS SECONDARY CONTAINMENT ISOLATION VALVES (SCIVS)
TEXT 3.6.4.3 4
09/21/2006
Title:
CONTAINMENT SYSTEMS STANDBY GAS TREATMENT (SGT)'SYSTEM 0
TEXT 3.7.1
Title:
PLANT SYSTEMS ULTIMATE HEAT 4
04/05/2010 RESIDUAL HEAT REMOVAL SERVICE WATER (RHRSW)
SYSTEM AND THE SINK (UHS)
TEXT 3.7.2
Title:
PLANT TEXT 3.7.3
Title:
PLANT TEXT 3. 7. 4
Title:
PLANT TEXT 3. 7. 5
Title:
PLANT TEXT 3.7. 6
Title:
PLANT TEXT 3. 7. 7
Title:
PLANT TEXT 3. 8. 1 2
05/02/2008 SYSTEMS EMERGENCY SERVICE WATER (ESW)
SYSTEM 1
01/08/2010 SYSTEMS CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS)
SYSTEM 0
11/18/2002 SYSTEMS CONTROL ROOM FLOOR COOLING SYSTEM 1
10/04/2007 SYSTEMS MAIN CONDENSER OFFGAS.
2 05/06/2009 SYSTEMS MAIN TURBINE BYPASS SYSTEM 1
10/04/2007 SYSTEMS SPENT FUEL STORAGE POOL WATER LEVEL 8
05/06/2009
Title:
ELECTRICAL POWER SYSTEMS AC SOURCES -
OPERATING TEXT 3.7.8 0
05/06/2009
Title:
MAINE TURBINE PRESSURE REGULATION SYSTEM TEXT 3.8.2 0
11/18/2002
Title:
ELECTRICAL POWER SYSTEMS AC SOURCES -
SHUTDOWN Page ~
of 8 Report Date: 04/05/10 Page6 of.8 Report Date: 04/05/10
SSES MANUAL Manual Name:
TSB2 Manual
Title:
TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL TEXT 3.8.3
Title:
ELECTRICAL TEXT 3.8.4
Title:
ELECTRICAL TEXT 3.8.5
Title:
ELECTRICAL TEXT 3.8.6
Title:
ELECTRICAL TEXT 3.8.7
Title:
ELECTRICAL TEXT 3.8.8
Title:
ELECTRICAL TEXT 3.9.1
Title:
REFUELING TEXT 3.9.2
Title:
REFUELING TEXT 3.9.3
Title:
REFUELING TEXT 3.9.4
Title:
REFUELING TEXT 3.9.5
Title:
REFUELING TEXT 3.9.6
Title:
REFUELING C POWER SYST POWER SYST POWER SYST POWER SYST POWER SYST POWER SYST
)PERATIONS
)PERATIONS
)PERATIONS OPERATIONS OPERATIONS DPERATIONS 1
04/23/2008 EMS DIESEL FUEL OIL LUBE OIL AND STARTING AIR LDCN 4756 3
01/19/2009 EMS DC SOURCES -
OPERATING 1
12/14/2006 EMS DC SOURCES -
SHUTDOWN 1
12/14/2006 PEMS BATTERY CELL PARAMETERS 3
03/31/2006
'EMS DISTRIBUTION SYSTEMS -
OPERATING 0
11/18/2002
'EMS DISTRIBUTION SYSTEMS -
SHUTDOWN 0
11/18/2002 REFUELING EQUIPMENT INTERLOCKS 0
11/18/2002 REFUEL POSITION ONE-ROD-OUT INTERLOCK 0
11/18/2002 CONTROL ROD POSITION 0
11/18/2002 CONTROL ROD POSITION INDICATION 0
11/18/2002 CONTROL ROD OPERABILITY -
REFUELING 1
10/04/2007 REACTOR PRESSURE VESSEL (RPV)
WATER LEVEL Pagel of 8
Report Date: 04/05/10 Page I of8 Report Date: 04/05/10
SSES MANUAL1 Manual Name:
TSB2 Manual
Title:
TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL TEXT 3.9.'7 0
11/18/2002
Title:
REFUELING OPERATIONS RESIDUAL HEAT REMOVAL (RHR)
HIGH WATER LEVEL TEXT 3.9.8 0
11/18/2002
Title:
REFUELING OPERATIONS RESIDUAL HEAT REMOVAL (RHR)
LOW WATER LEVEL TEXT 3.10.1
Title:
SPECIAL TEXT 3.10.2 Title. SPECIAL TEXT 3.10.3
Title:
SPECIAL TEXT 3.10'.4
Title:
SPECIAL TEXT 3.10.5
Title:
SPECIAL TEXT 3.10.6
Title:
SPECIAL TEXT 3.10.7
Title:
SPECIAL TEXT 3.10.8
Title:
SPECIAL OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS 1
01/23/2008 INSERVICE LEAK AND HYDROSTATIC TESTING OPERATION 0
11/18/2002 REACTOR MODE SWITCH :INTERLOCK TESTING 0
11/18/2002, SINGLE CONTROL ROD WITHDRAWAL HOT SHUTDOWN 0
11/18/2002-SINGLE CONTROL ROD WITHDRAWAL COLD SHUTDOWN 0
11/18/2002' SINGLE CONTROL'ROD' DRIVE*
(CRD)
REMOVAL REFUELING 0
11/18/2002 MULTIPLE CONTROL ROD WITHDRAWAL -,REFUELING 1
03/24/2005 CONTROL ROD TESTING -
OPERATING 2
04/09/2007 SHUTDOWN MARGIN (SDM)
TEST -
REFUELING Pages of 8 Report Date: 04/05/10 Page 8 of 8
Report Date: 04/05/10
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision TOC Table of Contents 16 B 2.0 SAFETY LIMITS BASES Page TS / B 2.0-1 1
Pages TS / B 2.0-2 and TS / B 2.0-3 4
Page TS / B 2.0-4 6
Pages TS / B 2.0-5 through TS / B 2.0-8 1
B 3.0 LCO AND SR APPLICABILITY BASES Page TS / B 3.0-1 1
Pages TS / B 3.0-2 through TS / B 3.0-4 0
Pages TS / B 3.0-5 through TS / B 3.0-7 1
Page TS / B 3.0-8 3
Pages TS / B 3.0-9 through Page TS / B 3.0-11 2
Page TS / B 3.0-11a 0
Page TS / B 3.0-12 1
Pages TS / B 3.0-13 through TS / B 3.0-15 2
Pages TS / B 3.0-16 and TS / B 3.0-17 0
B 3.1 REACTIVITY CONTROL BASES Pages B 3.1-1 through B 3.1-4 0
Page TS / B 3.1-5 1
Pages TS / B 3.1-6 and TS / B 3.1-7 2
Pages B 3.1-8 through B 3.1-13 0
Page TS / B 3.1-14 1.
Page TS / B 3.1-15 0
Page TS / B 3.1-16 1
Pages TS / B 3.1-17 through TS / B 3.1-19 0
Pages TS / B 3.1-20 and TS / B 3.1-21 1
Page TS / B 3.1-22 0
Page TS / B 3.1-23 1
Page TS / B 3.1-24 0
Pages TS / B 3.1-25 through TS / B 3.1-27 1
Page TS / B 3.1-28 2
Page TS / 3.1-29 1
Pages B 3.1-30 through B 3.1-33 0
Pages TS / B 3.1.34 through TS / B 3.1-36 1
Pages TS / B 3.1-37 and TS / B 3.1-38 2
Pages TS / B 3.1-39 and TS / B 3.1-40 2
Page TS / B 3.1-40a 0
Page TS / B 3.1-41 1
Page TS / B 3.1-42 2
SUSQUEHANNA
- UNIT 2 TS I B LOES-1 Revision 98 SUSQUEHANNA - UNIT 2 TS / B LOES-1 Revision 98
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision Pages TS / B 3.1-43 1
Page TS / B 3.1-44 0
Page TS / B 3.1-45 3
Page TS / B 3.1-46 0
Page TS / B 3.1-47 1
Pages TS / B 3.1-48 and TS / B 3.1-49 1
Page B 3.1-50 0
Page TS / B 3.1-51 3
B 3.2 POWER DISTRIBUTION LIMITS BASES Pages TS / B 3.2-1 and TS / B 3.2-2 2
Page TS / B 3.2-3 4
Page TS / B 3.2-4 1
Page TS / B 3.2-5 3
Page TS / B 3.2-6 4
Page TS / B 3.2-7 3
Pages TS / B 3.2-8 and TS / B 3.2-9 4
Pages TS / B 3.2-10 through TS / B 3.2-12 2
Page TS / B 3.2-13 1
B 3.3 INSTRUMENTATION Pages TS / B 3.3-1 through TS / B 3.3-4 1
Page TS / B 3.3-5 2
Page TS / B 3.3-6 1
Page TS / B 3.3-7 3
Page TS / B 3.3-8 4
Pages TS / B 3.3-9 through TS / B 3.3-13 3
Page TS / B 3.3-14 4
Pages TS / B 3.3-15 and TS / B 3.3-16 2
Pages TS / B 3.3-17 through TS / B 3.3-21 3
Pages TS / B 3.3-22 through TS / B 3.3-27 2
Page TS / B 3.3-28 3
Page TS / B 3.3-29 4
Pages TS / B 3.3-30 and TS / B 3.3-31 3
Pages TS / B 3.3-32 and TS / B 3.3-33 4
Page TS / B 3.3-34 2
Page TS / B 3.3-34a 1
Pages TS / B 3.3-34b through TS / B 3.3-34d 0
Page TS / B 3.3-34e 1
Pages TS / B 3.3-34f through TS / B 3.3-34i 0
Pages TS / B 3.3-35 and TS / B 3.3-36 2
Pages TS / B 3.3-37 and TS / B 3.3-38 1
SUSQUEHANNA - UNIT 2 TS / B LOES-2 Revision 98
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision Page TS / B 3.3-39 2
Pages TS / B 3.3-40 through TS / B 3.3-43 2
Rages TS / B 3.3-44 through TS / B 3.3-54 3
Pages TS / B 3.3-54a through TS / B 3.3-54e 0
Page TS / B 3.3-55 1
Page B 3.3-56 0
Page TS / B 3.3-57 1
Page B 3.3-58 0
Page TS / B 3.3-59 1
Pages B 3.3-60 through B 3.3-63 0
Pages TS / B 3.3-64 and TS / B 3.3-65 2
Page TS / B 3.3-66 4
Page TS / B 3.3-67 3
Page TS / B 3.3-68 4
Page TS / B 3.3.69 5
Page TS / B 3.3-70 4
Page TS / B 3.3-71 3
Pages TS / B 3.3-72 and TS / B 3.3-73 2
Page TS / B 3.3-74 3
Page TS / B 3.3-75 2
Pages TS / B 3.3-75a and TS / B 3.3-75 b 6
Page TS / B 3.3-75c 5
Pages B 3.3-76 and TS / B 3.3-77 0
Page TS / B 3.3-78 1
Pages B 3.3-79 through B 3.3-81 0
Page TS / B 3.3-82 1
Page B 3.3-83 0
Pages TS / B 3.3-84 and TS / B 3.3-85 1
Page 3.3-86 0
Page TS / B 3.3-87 1
Page B 3.3-88 0
Page TS / B 3.3-89 1
Pages B 3.3-90 and B 3.3-91 0
Pages TS / B 3.3-92 through TS / B 3.3-103 1
Page TS / B 3.3-104 3
Pages TS / B 3.3-105 and TS / B 3.3-106 1
Page TS / B 3.3-107 2
Page TS / B 3.3-108 1
Page TS / B 3.3-109 2
Pages TS / B 3.3-110 through TS / B 3.3-112 1
Page TS / B 3.3-113 2
Page TS / B 3.3-114 1
Page TS / B 3.3-115 2
Page TS / B 3.3-116 3
Pages TS / B 3.3-117 and TS / B 3.3-118 2
SUSQUEHANNA - UNIT 2 TS / B LOES-3 Revision 98
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision Pages TS / B 3.3-119 through TS / B 3.3-120 1
Pages TS / B 3.3-121 and TS / B 3.3-122 2
Page TS / B 3.3-123 1
Page TS / B 3.3-124 2
.Page TS / B 3.3-124a 0
Page TS / B 3.3-125 1
Page TS / B 3.3-126 2
Page TS / B 3.3-127 3
Page TS / B 3.3-128 2
Pages TS / B 3.3-129 through TS / B 3.3-131 1
Page TS / B 3.3-132 2
Pages TS / B 3.3-133 and TS / B 3.3-134 1
Pages B 3.3-135 through B 3.3-137 0
Page TS / B 3.3-138 1
Pages B 3.3-139 through B 3.3-149 0
Pages TS/ B 3.3-150 and TS / B 3.3-151 1
Pages TS / B 3.3-152 through TS / B 3.3-154 2
Page TS / B 3.3-155 1
Pages TS / B 3.3-156 through TS / B 3.3-158 2
Pages TS / B 3.3-159 through TS / B 3.3-161 1
Page TS / B 3.3-162 1
Page TS / B 3.3-163 2
Page TS / B 3.3-164 1
Pages TS / B 3.3-165 and TS / B 3.3-166 2
Pages TS / B 3.3-167 and TS / B 3.3-168 1
Pages TS / B 3.3-169 and TS / B 3.3-170 2
Pages TS / B 3.3-171 through TS /B 3.3-177 1
Page TS / B 3.3-178 2
Page TS / B 3.3-179 3
Page TS / B 3.3-179a 2
Page TS / B 3.3-180 1
Page TS / B 3.3-181 3
Page TS / B 3.3-182 1
Page TS / B 3.3-183 2
Page TS / B 3.3-184 1
Page TS / B 3.3-185 3
Page TS / B 3.3-186 1
Pages TS / B 3.3-187 and TS / B 3.3-188 2
Pages TS / B 3.3-189 through TS / B 3.3-191 1
Page TS / B 3.3-192 0
Page TS / B 3.3-193 1
Pages TS / B 3.3-194 and TS / B 3.3-195 0
Page TS / B 3.3-196 2
SUSQUEHANNA
- UNIT 2 TS / B LOES-.4 Revision 98 SUSQUEHANNA - UNIT 2 TS / B LOES-4 Revision 98
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision Pages TS / B 3.3-197 through TS / B 3.3-205 0
Page TS / B 3.3-206 1
Pages B 3.3-207 through B 3.3-209 0
Page TS / B 3.3-210 1
Page TS / B 3.3-211 2
Pages TS / B 3.3-212 and TS / B 3.3-213 1
Pages B 3.3-214 through B 3.3-220 0
B 3.4 REACTOR COOLANT SYSTEM BASES Pages TS / B 3.4-1 and TS / B 3.4-2 1
Pages TS / B 3.4-3 and TS / B 3.4-4 4
Pages TS / B 3.4-5 and TS / B 3.4-9 3
Pages B 3.4-10 through B 3.4-12 0
Page TS / B 3.4-13 1
Page B 3.4-14 0
Page TS / B 3.4-15 2
Pages TS / B 3.4-16 and TS / B 3.4-17 3
Page TS / B 3.4-18 2
Pages B 3.4-19 through B 3.4-23 0
Pages TS / B 3.4-24 through TS / B 3.4-27 0
Page TS / B 3.4-28 1
Page TS / B 3.4-29 3
Pages TS / B 3.4-30 and TS / B 3.3-31 0
Pages TS / B 3.4-32 and TS / B 3.4-33 1
Page TS / B 3.4-34 0
Pages TS / B 3.4-35 and TS / B 3.4-36 1
Page TS / B 3.4-37 2
Page B 3.4-38 1
Pages B 3.4-39 and B 3.4-40 0
Page TS / B 3.4-41 1
Pages B 3.4-42 through B 3.4-48 0
Page TS / B 3.4-49 3
Pages TS / B 3.4-50 through TS / B 3.4-52 2
Page TS / B 3.4-53 1
Pages TS / B 3.4-54 through TS / B 3.4-57 2
Pages TS / B 3.4-58 through TS / B 3.4-60 1
B 3.5 ECCS AND RCIC BASES Pages TS / B 3.5-1 and TS / B 3.5-2 1
Pages TS / B 3.5-3 through TS / B 3.5-6 2
Pages TS / B 3.5-7 through TS / B 3.5-10 1
Pages TS / B 3.5-11 and TS / B 3.5-12 2
Pages TS / B 3.6-13 and TS / B 3.5-14 1
SUSQUEHANNA
- UNIT 2 TS I B LOES-5 Revision 98 SUSQUEHANNA - UNIT 2 TS / B LOES-5 Revision 98
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision Pages TS / B 3.5-15 and TS / B.3.5-16 2
Page TS / B 3.5-17 3
Page TS / B 3.5-18 1
Pages B 3.5-19 through B 3.5-24 0
Pages TS / B 3.5-25 through TS / B 3.5-27 1
Pages B 3.5-28 through B 3.5-31 0
B 3.6 CONTAINMENT SYSTEMS BASES Page TS / B 3.6-1 2
Page TS / B 3.6-1a 3
Page TS / B 3.6-2 4
Page TS / B 3.6-3 3
Page TS / B 3.6-4 4
Page TS / B 3.6-5 3
Page TS / B 3.6-6 4
Pages TS / B 3.6-6a and TS / B 3.6-6b 2
Page TS / B 3.6-6c 0
Page B 3.6-7 0
Page TS / 3.6-8 1
Pages 3.6-9 through B 3.6-14 0
Page TS / B 3.6-15 3
Page TS / B 3.6-15a 0
Page TS / B 3.6-15b 3
Pages TS / B 3.6-16 and TS / B 3.6-17 2
Page TS / B 3.6-17a 0
Pages TS / B 3.6-18 and TS / B 3.6-19 1
Page TS / B 3.6-20 2
Page TS / B 3.6-21 3
Pages TS / B 3.6-21a and TS / B 3.6-21 b 0
Pages TS / B 3.6-22 and TS / B 3.6-23 2
Pages TS / B 3.6-24 and TS / B 3.6-25 1
Pages TS / B 3.6-26 and TS / B 3.6-27 3
Page TS / B 3.6-28 7
Page TS / B 3.6-29 5
Page TS / B 3.6-29a 0
Page TS / B 3.6-30 2
Page TS / B 3.6-31 3
Page TS / B 3.6-32 1
Page TS / B 3.6-33 2
Page TS / B 3.6-34 1
Page TS / B 3.6-35 3
Pages TS / B 3.6-36 and TS / B 3.6-37 2
Page TS / B 3.6-38 3
Page TS / B 3.6-39 7
SUSQUEHANNA
- UNIT 2 TS I B LOES-6 Revision 98 SUSQUEHANNA - UNIT 2 TS / B LOES-6 Revision 98
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision Page TS / B 3.6-40 1
Pages B 3.6-41 and B 3.6-42 0
Pages TS / B 3.6-43 and TS / B 3.6-44 1
Page TS / B 3.6-45 2
Pages TS / B 3.6-46 through TS / B 3.6-50 1
Page TS / B 3.6-51 2
Pages B 3.6-52 through B 3.6-55 0
Pages TS / B 3.6-56 and TS / B 3.6-57 2
Pages B 3.6-58 through B 3.6-62 0
Pages TS / B 3.6-63 and TS / B 3.6-64 1
Pages B 3.6-65 through B 3.6-68 0
Pages B 3.6-69 through B 3.6-71 1
Page TS / B 3.6-72 2
Pages TS / B 3.6-73 and TS / B 3.6-74 1
Pages B 3.6-75 and B 3.6-76 0
Page TS / B 3.6-77 1
Pages B 3.6-78 through B 3.6-82 0
Page TS / B 3.6-83 3
Page TS / B 3.6-84 2
Page TS / B 3.6-85 4
Page TS / B 3.6-86 through TS / B 3.6-87a 2
Page TS / B 3.6-88 4
Page TS / B 3.6-89 2
Page TS / B 3.6-90 3
Pages TS / B 3.6-91 through TS / B 3.6-95 1
Page TS / B 3.6-96 2
Pages TS / B 3.6-97 and TS / B 3.6-98 1
Page TS / B 3.6-99 3
Page TS / B 3.6-99a 0
Pages TS / B 3.6-100 and TS / B 3.6-101 1
Pages TS / B 3.6-102 and TS / B 3.6-103 2
Page TS / B 3.6-104 3
Page TS / B 3.6-105 2
Page TS / B 3.6-106 3
B 3.7 PLANT SYSTEMS BASES Page TS / B 3.7-1 3
Page TS / B 3.7-2 4
Pages TS / B 3.7-3 through TS / B 3.7-5 3
Page TS / B 3.7-5a 1
Page TS / B 3.7-6 3
Page TS / B 3.7-6a 2
Page TS / B 3.7-6b 1
SUSQUEHANNA
- UNIT 2 TS/BLOES-7 Revision 98 SUSQUEHANNA - UNIT 2 TS / B LOES-7 Revision 98
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision Page TS / B 3.7-6c 2
Page TS / B 3.7-7 3
Page TS / B 3.7-8 2
Pages B 3.7-9 through B 3.7-11 0
Pages TS / B 3.7-12 and TS / B 3.7-13 2
Pages TS / B 3.7-14 through TS / B 3.7-18 3
Page TS / B 3.7-18a 1
Pages TS / B 3.7-18b through TS / B 3.7-18e 0
Pages TS / B 3.7-19 through TS / B 3.7-24 1
Pages TS / B 3.7-25 and TS / B 3.7-26 0
Pages TS / B 3.7-27 through TS / B 3.7-29 3
Pages TS / B 3.7-30 and TS / B 3.7-31 1
Page TS / B 3.7-32 0
Page TS / B 3.7-33 1
Pages TS / B 3.7-34 through TS / B 3.7-37 0
B 3.8 ELECTRICAL POWER SYSTEMS BASES Page TS / B 3.8-1 1
Pages B 3.8-2 and B 3.8-3 0
Page TS / B 3.8-4 1
Pages TS / B 3.8-4a and TS / B 3.8-4b 0
Pages TS / B 3.8-5 and TS / B 3.8-6 3
Page TS / B 3.8-6a 1
Pages B 3.8-7 and B 3.8-8 0
Page TS / B 3.8-9 2
Pages TS / B 3.8-10 and TS / B 3.8-11 1
Pages B 3.8-12 through B 3.8-18 0
Page TS / B 3.8-19 1
Pages B 3.8-20 through B 3.8-22 0
Page TS / B 3.8-23 1
Page B 3.8-24 0
Pages TS / B 3.8-25 and TS / B 3.8-26 1
Pages B 3.8-27 through B 3.8-35 0
Page TS / B 3.8-36 1
Page TS / B 3.8-37 0
Page TS / B 3.8-38 1
Pages TS / B 3.8-39 through TS / B 3.8-46 0
Page TS / B 3.8-47 1
Pages TS / B 3.8-48 through TS / B 3.8-50 0
Page TS / B 3.8-51 1
Pages TS / B 3.8-52 through TS / B 3.8-55 0
Pages TS / B 3.8-56 through TS / B 3.8-59 2
Pages TS / B 3.8-60 through TS / B 3.8-64 3
SUSQUEHANNA
- UNIT 2 TS/BLOES-8 Revision 98 SUSQUEHANNA - UNIT 2 TS / B LOES-8 Revision 98
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Revision Page TS / B 3.8-65 4
Page TS / B 3.8-66 5
Pages TS / B 3.8-67 and TS / B 3.8-68 4
Page TS / B 3.8-69 5
Pages TS / B 3.8-70 through TS / B 3.8-83 1
Pages TS / B 3.8-83A through TS / B 3.8-83D 0
Pages B 3.8-84 through B 3.8-85 0
Page TS / B 3.8-86 1
Page TS / B 3.8-87 2
Pages TS / B 3.8-88 through TS / B 3.8-93 1
Pages B 3.8-94 through B 3.8-99 0
B 3.9 REFUELING OPERATIONS BASES Pages TS / B 3.9-1 and TS / B 3.9-2 1
Page TS / B 3.9-2a 1
Pages TS / B 3.9-3 and TS / B 3.9-4 1
Pages B 3.9-5 through B 3.9-18 0
Pages TS / B 3.9-19 through TS / B 3.9-21 1
Pages B 3.9-22 through B 3.9-30 0
B 3.10 SPECIAL OPERATIONS BASES Page TS / B 3.10-1 2
Pages TS / B 3.10-2 through TS / B 3.10-5 1
Pages B 3.10-6 through B 3.10-32 0
Page TS / B 3.10-33 2
Page B 3.10-34 0
Page B 3.10-35 1
Pages B 3.10-36 and B 3.10-37 0
Page B 3.10-38 1
Page TS / B 3.10-39 2
TSB2 Text LOES.doc 3/2612010 SUSQUEHANNA
- UNIT 2 TS/BLOES-9 Revision 98 SUSQUEHANNA - UNIT 2 TS / B LOES-9 Revision 98
PPL Rev. 4 RHRSW System and UHS B 3.7.1 B 3.7 PLANT SYSTEMS B 3.7.1 Residual Heat Removal Service Water (RHRSW) System and the Ultimate Heat Sink (UHS)
BASES BACKGROUND The RHRSW System is designed to provide cooling water for the Residual Heat Removal (RHR) System heat exchangers, required for a safe reactor shutdown following a Design Basis Accident (DBA) or transient. The RHRSW System is operated whenever the RHR heat exchangers are required to operate in the shutdown cooling mode or in the suppression pool cooling or spray mode of the RHR System.
The RHRSW System consists of two independent and redundant subsystems. Each subsystem is made up of a header, one pump, a suction source, valves, piping, heat exchanger, and associated instrumentation. Either of the two subsystems is capable of providing the required cooling capacity to maintain safe shutdown conditions. The two subsystems are separated so that failure of one subsystem will not affect the OPERABILITY of the other subsystem. One Unit 1 RHRSW subsystem and the associated (same division) Unit 2 RHRSW subsystem constitute a single RHRSW loop. The two RHRSW pumps in a loop can each, independently, be aligned to either Unit's heat exchanger. The RHRSW System is designed with sufficient redundancy so that no single active component failure can prevent it from achieving its design function.
The RHRSW System is described in the FSAR, Section 9.2.6, Reference 1.
Cooling water is pumped by the RHRSW pumps from the UHS through the tube side of the RHR heat exchangers. After removing heat from the RHRSW heat exchanger, the water is discharged to the spray pond (UHS) by way of the UHS return loops. The UHS return loops direct the return flow to a network of sprays that dissipate the heat to the atmosphere or directly to the UHS via a bypass header.
The system is initiated manually from the control room except for the spray array bypass manual valves that are operated locally in the event of a failure of the spray array bypass valves. The system can be started any time the LOCA signal is manually overridden or clears.
(continued)
SUSQUEHANNA - UNIT 2 TS / B 3.7-1 Revision 3
PPL Rev. 4 RHRSW System and UHS B 3.7.1 BASES BACKGROUND (continued)
The ultimate heat sink (UHS) system is composed of approximately 3,300,000 cubic foot spray pond and associated piping and spray risers.
Each UHS return loop contains a bypass line, a large spray array and a small spray array. The purpose of the UHS is to provide both a suction source of water and a return path for the RHRSW and ESW systems.
The function of the UHS is to provide water to the RHRSW and ESW systems at a temperature less than the 970F design temperature of the RHRSW and ESW systems. UHS temperature is maintained less than the design temperature by introducing the hot return fluid from the RHRSW and ESW systems into the spray loops and relying on spray cooling to maintain temperature. The UHS is designed to supply the RHRSW and ESW systems with all the cooling capacity required during a combination LOCA/LOOP for thirty days without fluid addition. The UHS is described in the FSAR, Section 9.2.7 (Reference 1).
APPLICABLE SAFETY ANALYSES The RHRSW System removes heat from the suppression pool to limit the suppression pool temperature and primary containment pressure following a LOCA. This ensures that the primary containment can perform its function of limiting the release of radioactive materials to the environment following a LOCA. The ability of the RHRSW System to support long term cooling of the reactor or primary containment is discussed in the FSAR, Chapters 6 and 15 (Refs. 2 and 3, respectively). These analyses explicitly assume that the RHRSW System will provide adequate cooling support to the equipment required. for safe shutdown. These analyses include the evaluation of the long term primary containment response after a design basis LOCA.
The safety analyses for long term cooling were performed for various RHRSW and UHS configurations combinations of RHR System failures.
As discussed in the FSAR, Section 6.2.2 (Ref. 2) for these analyses, manual initiation of the OPERABLE RHRSW subsystem and the associated RHR System is required. The maximum suppression chamber water temperature and pressure are analyzed to be below the design temperature of 220°F and maximum allowable pressure of 53 psig.
(continued)
SUSQUEHANNA - UNIT 2 TS / B 3.7-2 Revision 4
PPL Rev. 4 RHRSW System and UHS B 3.7.1 BASES APPLICABLE The UHS design takes into account the cooling efficiency of the spray SAFETY arrays and the evaporation losses during design basis environmental ANALYSES conditions. The spray array bypass header provides the flow path for the (continued)
ESW and RHRSW system to keep the spray array headers from freezing.
The small and/or large spray arrays are placed in service to dissipate heat returning from the plant. The UHS return header is comprised of the spray array bypass header, the large spray array, and the small spray array.
The spray array bypass header is capable of passing full flow from the RHRSW and ESW systems in each loop. The large spray array is capable of passing full flow from the RHRSW and ESW systems in each loop. The small spray array supports heat dissipation when low system flows are required.
The RHRSW System, together with the UHS, satisfy Criterion 3 of the NRC Policy Statement. (Ref. 4)
LCO Two RHRSW subsystems are required to be OPERABLE to provide the required redundancy to ensure that the system functions to remove post accident heat loads, assuming the worst case single active failure occurs coincident with the loss of offsite power.
An RHRSW subsystem is considered OPERABLE when:
- a. One pump is OPERABLE; and
- b. An OPERABLE flow path is capable of taking suction from the UHS and transferring the water to the RHR heat exchanger and returning it to the UHS at the assumed flow rate, and
The OPERABILITY of the UHS is based on having a minimum water level at the overflow weir of 678 feet 1 inch above mean sea level and a maximum water temperature of 850F; unless either unit is in MODE 3. If a unit enters MODE 3, the time of entrance into this condition determines the appropriate maximum ultimate heat sink fluid temperature. If the earliest unit to enter MODE 3 has been in that condition for less than twelve.(12) hours, the peak temperature to maintain OPERABILITY of the ultimate heat sink remains at 850 F. If either unit has been in MODE 3 for more than twelve (12) hours but less than twenty-four (24) hours, the OPERABILITY temperature of the ultimate heat sink becomes 870 F. If either unit has been in MODE 3 for twenty-four (24) hours or more, the OPERABILITY temperature of the ultimate heat sink becomes 880F.
(continued)
SUSQUEHANNA - UNIT 2 TS / B 3.7-3 Revision 3
PPL Rev. 4 RHRSW System and UHS B 3.7.1 BASES LCO In addition, the OPERABILITY of the UHS is based on having sufficient (continued) spray capacity in the UHS return loops. Sufficient spray capacity is defined as one large and one small spray array in one loop.
This OPERABILITY definition is supported by analysis and evaluations performed in accordance with the guidance given in Regulatory Guide 1.27.
APPLICABILITY In MODES 1, 2, and 3, the RHRSW System and the UHS are required to be OPERABLE to support the OPERABILITY of the RHR System for primary containment cooling (LCO 3.6.2.3, "Residual Heat Removal (RHR)
Suppression Pool Cooling," and LCO 3.6.2.4, "Residual Heat Removal (RHR) Suppression Pool Spray") and decay heat removal (LCO 3.4.8, "Residual Heat Removal (RHR) Shutdown Cooling System-Hot Shutdown"). The Applicability is therefore consistent with the requirements of these systems.
In MODES 4 and 5, the OPERABILITY requirements of the RHRSW System are determined by the RHR shutdown cooling subsystem(s) it supports (LCO 3.4.9, "Residual Heat Removal (RHR) Shutdown Cooling System - Cold Shutdown"; LCO 3.9.7, "Residual Heat Removal (RHR) -
High Water Level"; and LCO 3.9.8, "Residual Heat Removal (RHR) - Low Water Level").
In MODES 4 and 5, the OPERABILITY requirements of the UHS is determined by the systems it supports.
ACTIONS The ACTIONS are modified by a Note indicating that the applicable Conditions of LCO 3.4.8, be entered and Required Actions taken if the inoperable RHRSW subsystem results in inoperable RHR shutdown cooling (SDC) (i.e., both the Unit 1 and Unit 2 RHRSW pumps in a loop are inoperable resulting in the associated RHR SDC system being inoperable). This is an exception to LCO 3.0.6 because the Required Actions of LCO 3.7.1 do not adequately compensate for the loss of RHR SDC Function (LCO 3.4.8).
Condition A is modified by a separate note to allow separate Condition entry for each valve. This is acceptable since the Required Action for this Condition provide appropriate compensatory actions.
(continued)
SUSQUEHANNA - UNIT 2 TS / B 3.7-4 Revision 3
PPL Rev. 4 RHRSW System and UHS B 3.7.1 BASES ACTIONS A.1, A.2 and A.3 (continued)
With one spray loop bypass valve not capable of being closed on demand, the associated Unit 1 and Unit 2 RHRSW subsystems cannot use the spray cooling function of the affected UHS return loop. As a result, the associated RHRSW subsystem must be declared inoperable.
With one spray loop bypass valve not capable of being opened on demand, a return flow path is not available. As a result, the associated RHRSW subsystems must be declared inoperable.
With one spray array bypass manual valve not capable of being closed, the associated Unit 1 and Unit 2 RHRSW subsystems cannot use the spray cooling function of the affected UHS return path if the spray array bypass valve fails to close. As a result, the associated RHRSW subsystems must be declared inoperable.
With one spray array bypass manual valve not open, a return flow path is not available. As a result, the associated RHRSW subsystems must be declared inoperable.
With one large spray array valve not capable of being opened on demand, the associated Unit 1 and Unit 2 RHRSW subsystems cannot use the full required spray cooling capability of the affected UHS return path. With one large spray array valve not capable of being closed on demand, the associated Unit 1 and Unit 2 RHRSW subsystems cannot use the small spray array when loop flows are low as the required spray nozzle pressure is not achievable for the small spray array. As a result, the associated RHRSW subsystems must be declared inoperable.
With one small spray array valve not capable of being opened on demand, the associated Unit 1 and Unit 2 RHRSW subsystems cannot use the spray cooling function of the affected UHS return path for low loop flow rates. For a single failure of the large spray array valve in the closed position, design bases LOCA/LOOP calculations assume that flow is reduced on the affected loop within 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> after the event to allow use of the small spray array. With one small spray array valve not capable of being closed on demand, the associated Unit 1 and Unit 2 RHRSW subsystems cannot use the large spray array for a flow path as the required nozzle pressure is not achievable for the large spray array. As a result, the associated RHRSW subsystems must be declared inoperable.
(continued)
SUSQUEHANNA - UNIT 2 TS / B 3.7-5 Revision 3
PPL Rev. 4 RHRSW System and UHS B 3.7.1 BASES ACTIONS A.1, A.2 and A.3 (continued)
With any UHS return path valve listed in Tables 3.7.1-1, 3.7.1-2, or 3.7.1-3 inoperable, the UHS return path is no longer single failure proof.
For combinations of inoperable valves in the same loop, the UHS spray capacity needed to support the OPERABILITY of the associated Unit 1 and Unit 2 RHRSW subsystems is affected. As a result, the associated RHRSW subsystems must be declared inoperable.
The 8-hour completion time to establish the flow path provides sufficient time to open a path and de-energize the appropriate valve in the open position.
The 72-hour completion time is based on the fact that, although adequate UHS spray loop capability exists during this time period, both units are affected and an additional single failure results in a system configuration that will not meet design basis accident requirements.
If an additional RHRSW subsystem on either Unit is inoperable, cooling capacity less than the minimum required for response to a design basis event would exist. Therefore, an 8-hour Completion Time is appropriate.
The 8-hour Completion Time provides sufficient time to restore inoperable equipment and there is a low probability that a design basis event would occur during this period.
B. 1 Required Action B.1 is intended to ensure that appropriate actions are taken if one Unit 2 RHRSW subsystem is inoperable. Although designated and operated as a unitized system, the associated Unit 1 subsystem is directly connected to a common header which can supply the associated RHR heat exchanger in either unit. The associated Unit 1 subsystem is considered capable of supporting the associated Unit 2 RHRSW subsystem when the Unit 1 subsystem is OPERABLE and can provide the assumed flow to the Unit 2 heat exchanger. A Completion time of 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, when the associated Unit 1 RHRSW subsystem is not capable of supporting the associated Unit 2 RHRSW subsystem, is allowed to restore the Unit 2 RHRSW subsystem to OPERABLE status.
In this configuration, the remaining OPERABLE Unit 2 RHRSW subsystem is adequate to perform the RHRSW heat removal function.
However, the overall reliability is reduced because a single failure in the OPERABLE RHRSW subsystem (continued)
SUSQUEHANNA - UNIT 2 TS / B 3.7-5a Revision 1
PPL Rev. 4 RHRSW System and UHS B 3.7.1 BASES ACTIONS B.1 (continued could result in loss of RHRSW function. The Completion Time is based on the redundant RHRSW capabilities afforded by the OPERABLE subsystem and the low probability of an event occurring requiring RHRSW during this period.
With one RHRSW subsystem inoperable, and the respective Unit 1 RHRSW subsystem capable of supporting the respective Unit 2 RHRSW subsystem, the design basis cooling capacity for both units can still be maintained even considering a single active failure. However, the configuration does reduce the overall reliability of the RHRSW System.
Therefore, provided the associated Unit 1 subsystem remains capable of supporting its respective Unit 2 RHRSW subsystem, the inoperable RHRSW subsystem must be restored to OPERABLE status within 7 days.
The 7-day Completion Time is based on the remaining RHRSW System heat removal capability.
C.1 Required Action C.1 is intended to ensure that appropriate actions are taken if both Unit 2 RHRSW subsystems are inoperable. Although designated and operated as a unitized system, the associated Unit 1 subsystem is directly connected to a common header which can supply the associated RHR heat exchanger in either unit. With both Unit 2 RHRSW subsystems inoperable, the RHRSW system is still capable of performing its intended design function. However, the loss of an additional RHRSW subsystem on Unit 1 results in the cooling capacity to be less than the minimum required for response to a design basis event.
Therefore, the 8-hour Completion Time is appropriate. The 8-hour Completion Time for restoring one RHRSW subsystem to OPERABLE status, is based on the Completion Times provided for the RHR suppression pool spray function.
With both Unit 2 RHRSW subsystems inoperable, and both of the Unit 1 RHRSW subsystems capable of supporting their respective Unit 2 RHRSW subsystem, if no additional failures occur which impact the RHRSW System, the remaining OPERABLE Unit I subsystems and flow paths provide adequate heat removal capacity following a design basis LOCA. However, capability for this alignment is not assumed in long term containment response analysis and an additional single failure in the RHRSW System could reduce the system capacity below that assumed in the safety analysis.
(continued)
SUSQUEHANNA - UNIT 2 TS / B 3.7-6 Revision 3
PPL Rev. 4 RHRSW System and UHS B 3.7.1 BASES ACTIONS C.1 (continued)
Therefore, continued operation is permitted only for a limited time. One inoperable subsystem is required to be restored to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />. The 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Completion Time for restoring one inoperable RHRSW subsystem to OPERABLE status is based on the fact that the alternate loop is capable of providing the required cooling capability during this time period.
D.1 and D.2 If the RHRSW subsystems cannot be restored to OPERABLE status within the associated Completion Times, or the UHS is determined to be inoperable, the unit must be placed in a MODE in which the LCO does not apply. To achieve this status, the unit must be placed in at least MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach the required unit conditions from full power conditions in an orderly manner and without challenging unit systems.
SURVEILLANCE SR 3.7.1.1 REQUIREMENTS This SR verifies the water level to be sufficient for the proper operation of the RHRSW pumps (net positive suction head and pump vortexing are considered in determining this limit). The 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Frequency is based on operating experience related to trending of the parameter variations during the applicable MODES.
SR 3.7.1.2 Verification of the UHS temperature, which is the arithmetical average of the UHS temperature near the surface, middle and bottom levels, ensures that the heat removal capability of the ESW and RHRSW Systems are within the assumptions of the DBA analysis. The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Frequency is based on operating experience related to trending of the parameter variations during the applicable MODES.
(continued)
SUSQUEHANNA - UNIT 2 TS / B 3.7-6a Revision 2
PPL Rev. 4 RHRSW System and UHS B 3.7.1 BASES SURVEILLANCE REQUIREMENTS (continued)
SR 3.7.1.3 Verifying the correct alignment for each manual, power operated, and automatic valve in each RHRSW subsystem flow path provides assurance that the proper flow paths will exist for RHRSW operation. This SR does not apply to valves that are locked, sealed, or otherwise secured in position, since these valves are verified to be in the correct position prior to locking, sealing, or securing. A valve is also allowed to be in the nonaccident position, and yet considered in the correct position, provided it can be realigned to its accident position. This is acceptable because the RHRSW System is a manually initiated system.
This SR does not require any testing or valve manipulation; rather, it involves verification that those valves capable of being mispositioned are in-the correct position. This SR does not apply to valves that cannot be inadvertently misaligned, such as check valves.
The 31-day Frequency is based on engineering judgment, is consistent with the procedural controls governing valve operation, and ensures correct valve positions.
SR 3.7.1.4 The UHS spray array bypass valves are required to actuate to the closed position for the UHS to perform its design function. These valves receive an automatic signal to open upon emergency service water (ESW) or residual heat removal service water (RHRSW) system pump start and are required to be operated from the control room or the remote shutdown panel. A spray bypass valve is considered to be inoperable when it cannot be closed on demand. Failure of the spray bypass valve to close on demand puts the UHS at risk to exceed its design temperature. The failure of the spray bypass valve to open on demand makes one return path unavailable, and therefore the associated RHRSW subsystems must be declared inoperable. This SR demonstrates that the valves will move to their required positions when required. The 92-day Test Frequency is based upon engineering judgment and operating/testing history that indicates this frequency gives adequate assurance that the valves will move to their required positions when required.
(continued)
SUSQUEHANNA - UNIT 2 TS / B 3.7-6b Revision 1
PPL Rev. 4 RHRSW System and UHS B 3.7.1 BASES SURVEILLANCE REQUIREMENTS (continued)
SR 3.7.1.5 The UHS return header large spray array valves are required to open in order for the UHS to perform its design function. These valves are manually actuated from either the control room or the remote shutdown panel, under station operating procedure, when the RHRSW system is required to remove energy from the reactor vessel or suppression pool.
This SR demonstrates that the valves will move to their required positions when required.
The 92-day Test Frequency is based upon engineering judgment and operating/testing history that indicates this frequency gives adequate assurance that the valves will move to their required positions when required.
SR 3.7.1.6 The small spray array valves HV-01224A2 and B2 are required to operate in order for the UHS to perform its design function. These valves are manually actuated from the control room or the remote shutdown panel, under station operating procedure, when the RHRSW system is required to remove energy from the reactor vessel or suppression pool. This SR demonstrates that the valves will move to their required positions when required. The 92-day Test Frequency is based upon engineering judgment and operating/testing history that indicates this frequency gives adequate assurance that the valves will move to their required positions when required.
SR 3.7.1.7 The spray array bypass manual valves 012287A and B are required to operate in the event of a failure of the spray array bypass valves to close in order for the UHS to perform its design function.
REFERENCES
- 1. FSAR, Section 9.2.
- 2. FSAR, Chapter 6.
- 3. FSAR, Chapter 15.
- 4. Final Policy Statement on Technical Specifications Improvements, July 22, 1993 (58 FR 39132).
SUSQUEHANNA - UNIT 2 TS / B 3.7-6c Revision 2