ML19210D264

From kanterella
Revision as of 05:21, 2 February 2020 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
LER 79-090/03L-0:on 791027,shift in Output Occurred in Atmospheric Monitor 1-CAC-1263-3.Caused by Intermittent Failings of Magnetic Amplifier.Amplifier Replaced & Monitor Returned to Svc
ML19210D264
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 11/21/1979
From: Tollison A
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19210D261 List:
References
LER-79-090-03L, LER-79-90-3L, NUDOCS 7911260210
Download: ML19210D264 (2)


Text

NRC FORM 366 ,

U. S NUCLEAR REGULATORY COMMISSION (7 77),. p ,

LICENSEE EVENT REPORT l (PLEASE PRINT OR TYPE ALL REOUIRED INFORMATIONI CONTROL BLOCK: l i

l l l l 6

lh 7

0 1 8 3 lNlC l 3 l E l P l 141 l@l LICE %EE CODE 15 0 l 0 l - l 0 lL60CENSE l 0 l 0 -w l 0 l 0 26l@l264 l 1LICENSE l 0 NUMBER l 1 l,1 l 1 l@l l TYPE J0 57 CAT 58 CON'T 7

O i 3

3E lL @l015l0l-10l3l2l5 @l11012l7l7 91@

60 61 OOCKET NUMBER 66 69 EVENT OATE 74 75 l l l REPORT DATE l l 80 lh EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h O 2 l During normal operation, the operator noticed that the containment O 3 l atmospheric monitor 1-CAC-1263-2 had an unexplained shif t in its output. I O 4 I I O 5 l l 0 6 l l O 7 l l ,

O 8 I Technical Specifications 3.3.5.3. 6.9.1.9.b. I SYSTEM CAUSE CAUSE COMP. VALVE CODE CODE SUSCODE COMPONENT CODE SUBCODE SU8 CODE g

7 8 l Sl Elh Wh Wh l Il Nl Sl Tl Rl Ulh Wh W h 9 10 11 12 13 18 19 20

_ SEQUENTIAL OCCURRENCE REPORT REVISION LER RO E REPORT NO. CODE TYPE NO.

O asgg su

_ 21 l 7VENT l9 YEAR 22 l-l 23 1019 l Ol 24 26 l/

27 l0l3l 28 29 lLl 30

[--j 31 W32 KN A O ONP NT MET HOURS SB 4 FOR 8. SUP LIE MANUFACTURER lAl@lCl@

33 34 W@

35

[2_j@

36 l0 l 0l Ol 0l 37 W@ lY l@ l A lh l B l 1l 3 Sl@

41 40 42 43 44 47 CAUSE OESCRIPTION AND CORRECTIVE ACTIONS h 1 O [ An investigation determined that the mannetic amolifier was failine intermittent 1v. I Ii l11 I The amplifier was replaced and the monitor was returned to service. Since air I

, 2 l dryers were installed on these instruments two years ago, the problems with the I gl magnetic amplifiers have been significantly reduced. Due to the problems being l gl experienced with these containment monitors, Engineering is evaluating other i 7 s 9 80 SA 5  % POWER OTH ER STATUS 015 O RY DISCOVERY OESCRIPTION 1 5 (_E_jh l 0 l 9 l 1 l@l NA l l A lhl Operator Surveillance l A TIVITY CO TENT

  • RELEASED CF RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE 6

7 1

s 9 h l Z l@l 10 11 NA 44 45 NA l ,

PERSONNEL EXPOAURES NUUSER ln %hI g1 l

"Q DESCRIPTION U i 78 , 0l 0l OlhlTYPEZ lhl NA Os Qd b * ~'

.ERSONsE L l~2u'llES NUYSER DESCRIPTION @ 1 p 0i 117 fit 1 8101 7 9 01 Ol@l 11 12 NA l 80 LOSS OF OR DAMAGE TO FACILITV O TYPE OESCRIPTION U d (_Jjhl 7 d 9 to NA 7911260 2 / ol 80 ISSUE DESCRIPT.ON

  • 7 2 o a

l N hliO s

NA l l l l l l l l l l 1 l I l *:

68 69 80 E NAME OF PREPARER A. C. To111 son, Jr.

PHONE: 919-457-9521

- .s -

LER CONTINUATION - RO# 1-79-90 -

Facility: BSEP Unit No. 1 Event Date: 10-27-79 instrumentation to replace that now in use.

G 1391 118 O

e e

S