K. Sherin Letter Re; Request for Additional Information Regarding Parent Company Guarantee and Annual Financial Test for General Electric Hitachi (TAC No. L33125)
ML111300315
Person / Time
Site: Vallecitos Nuclear Center, 07000754, 07001113, 07002872, 07200001, Vallecitos
Issue date: 06/02/2011
From: Ryder C
NRC/NMSS/FCSS/FCLD/FMB
To: Sherin K
General Electric Co
Shared Package
ML111300305 List:
References
TAC L33125
Download: ML111300315 (3)


Text

June 2, 2011 Mr. Keith S. Sherin Vice Chairman and Chief Financial Officer General Electric 3135 Easton Turnpike Fairfield, CT 06828

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION REGARDING PARENT COMPANY GUARANTEE AND ANNUAL FINANCIAL TEST FOR GENERAL ELECTRIC HITACHI (TAC NO. L33125)

Dear Mr. Sherin:

We have completed our review of your annual certification of financial assurance, transmitted by letter dated March 18, 2011. Our review of your application has identified that additional information is needed before final action can be taken on you submittal.

The additional information, specified in the enclosure, should be provided within 30 days from the date of this letter.

Pending the additional information, which answers the Request for Additional Information, we anticipate completing our review by the end of July 2011. This date could change depending on the findings of our technical review, urgent assignments, or other factors. We will promptly communicate any significant changes to this schedule.

In accordance with Title 10 of the Code of Federal Regulations, 2.390 of the U.S. Nuclear Regulatory Commissions (NRCs) Rules of Practice, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records System component of the NRCs Agencywide Document Access Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.

K. Sherin If you have any questions regarding this matter, please contact me at 301-492-3189 or via e-mail to Christopher.Ryder@nrc.gov.

Sincerely,

/RA/

Christopher Ryder, Licensing Project Manager Fuel Manufacturing Branch Division of Fuel Cycle Safety and Safeguards Office of Nuclear Material Safety and Safeguards Docket Nos. 50-18, 50-70, 50-183,70-754, 70-1113, 70-2872, 72-01 SNM License Nos. DPR-1, DR-10, R-33, SNM-960, SNM-1097, SNM-1826, SNM-2500, TR-1

K. Sherin If you have any questions regarding this matter, please contact me at 301-492-3189 or via e-mail to Christopher.Ryder@nrc.gov.

Sincerely, Christopher Ryder, Licensing Project Manager Fuel Manufacturing Branch Division of Fuel Cycle Safety and Safeguards Office of Nuclear Material Safety and Safeguards Docket Nos. 50-18, 50-70, 50-183,70-754, 70-1113, 70-2872, 72-01 SNM License Nos. DPR-1, DR-10, R-33, SNM-960, SNM-1097, SNM-1826, SNM-2500, TR-1 DISTRIBUTION:

FCSS r/f ML111300305 OFFICE NMSS/FCSS/FMB NMSS/FCSS/FMB NRR NMSS/FCSS/FMB NAME CRyder LAllen W. Moore for CRegan by RJohnson e-mail DATE 5/12/2011 5/12/2011 5/ 26/2011 5/ /2011 OFFICIAL USE ONLY