LER 79-050/03L-0 on 790619:2A RHR Svc Water Pump Uncoupled by Mistake After Clearance of 2B Pump for Uncoupling.Caused by Personnel Error.Pump Recoupled & Tested When Mistake Was Discovered.Clearance Procedure Changed
ML19246B531
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 07/12/1979
From: Tollison A
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19246B530 List:
References
LER-79-050-03L, LER-79-50-3L, NUDOCS 7907160400