Semantic search

Jump to navigation Jump to search
Condition
Printout selection
Options
Parameters [
limit:

The maximum number of results to return
offset:

The offset of the first result
link:

Show values as links
headers:

Display the headers/property names
mainlabel:

The label to give to the main page name
intro:

The text to display before the query results, if there are any
outro:

The text to display after the query results, if there are any
searchlabel:

Text for continuing the search
default:

The text to display if there are no query results
class:

An additional CSS class to set for the table
transpose:

Display table headers vertically and results horizontally
sep:

The separator between results
prefix:

Control display of namespace in printouts
Sort options
Delete
Add sorting condition
 Issue dateTitleTopic
05000000/LER-1986-009, Ro:On 860312,discovered That LER 2-86-04 & LER 86-009 Not Submitted to Nrc.Caused by Misplaced Repts.Repts Telecopied to Nrc.Procedure for Distribution of Repts Revised14 April 1986Ro:On 860312,discovered That LER 2-86-04 & LER 86-009 Not Submitted to Nrc.Caused by Misplaced Repts.Repts Telecopied to Nrc.Procedure for Distribution of Repts Revised
AECM-84-0204, Special Rept 84-017/0:on 840304,Fire Doors 1A401 & OC219 Blocked Open to Support Maint Activities.Fire Watches Established Until Doors Restored6 April 1984Special Rept 84-017/0:on 840304,Fire Doors 1A401 & OC219 Blocked Open to Support Maint Activities.Fire Watches Established Until Doors Restored
BECO-85-220, Partially Withheld Security Event Rept:On 851204 Vertical Pipe Chase Not Locked.Lock Removed When Surveys Indicated Radiation Level Below Requirement for Locked High Radiation Level.Pipe Chase Will Be Secured9 December 1985Partially Withheld Security Event Rept:On 851204 Vertical Pipe Chase Not Locked.Lock Removed When Surveys Indicated Radiation Level Below Requirement for Locked High Radiation Level.Pipe Chase Will Be Secured
BECO-86-016, Partially Withheld Security Event Rept:On 860215 Security Officer Appeared to Be Asleep at Post at Vital Area Penetration.Unathorized Entry of Vital Area Did Not Occurr. Security Officer Relieved of Duty & Suspended20 February 1986Partially Withheld Security Event Rept:On 860215 Security Officer Appeared to Be Asleep at Post at Vital Area Penetration.Unathorized Entry of Vital Area Did Not Occurr. Security Officer Relieved of Duty & Suspended
BECO-86-125, Partially Withheld Security Event Rept:On 860826,bomb Threat Received.Search Initiated.No Suspicious Objects Found29 August 1986Partially Withheld Security Event Rept:On 860826,bomb Threat Received.Search Initiated.No Suspicious Objects Found
BECO-86-171, Partially Withheld Security Event Rept:On 861106,temporary Vital Area Barrier Insp Found Barrier Could Be Breached. Barrier Modified & Compensatory Security Measures Released10 November 1986Partially Withheld Security Event Rept:On 861106,temporary Vital Area Barrier Insp Found Barrier Could Be Breached. Barrier Modified & Compensatory Security Measures Released
BECO-86-173, Partially Withheld Security Event Rept:On 861107,HVAC Duct, Penetrating Vital Area,Removed by Contracted Craft Workers Before Notifying Security.Cause Not Stated.Security Oversight of Subj Contract Work Intensified12 November 1986Partially Withheld Security Event Rept:On 861107,HVAC Duct, Penetrating Vital Area,Removed by Contracted Craft Workers Before Notifying Security.Cause Not Stated.Security Oversight of Subj Contract Work Intensified
ML20065R40020 October 1982Ro:On 821006,malfunction of Eberline AMS-3 Continuous Air Monitor Pump Caused Pump to Be Inoperable for Approx 1-h.No Loss of Significant Signals Indicated.Pump Repaired.Changes to Procedures or Equipment Under Review
ML20070J8581 October 1976RO 76-12:on 760909,low Pressure Alarm Occurred on Safety Injection Accumulator C,Resulting in Pressure Reduction. Caused by Partially Open HCV 1936 & Body to Bonnet Leaks on HCV 1898 & 1549.Valves Repaired & Accumulator Repressurized
ML20070J86820 October 1976RO 76-13:on 760916,normal Boric Acid Makeup to Vol Control Tank Could Not Be Accomplished Due to Plugging of Chemical & Vol Control Sys Line 1-inch-CH-56-152.Cause Unknown.Line Will Be Inspected for Indications of SolidificationBoric Acid
ML20070J88024 September 1976RO 76-07:on 760913,monthly Average of Gaseous & Airborne Particulate Wastes for Previous 12 Months Found Greater than Tech Spec Limit.Caused by Interpretational Changes in Tech Spec Section 3.11.B.New Limit Approved
ML20070J89629 September 1976RO 76-05:on 760915,pressurizer Level Fell Below 45% Level Setpoint,Resulting in Decreases of Pressurizer Pressure & Vol Control Tank Level.Caused by Leaking Tube in Steam Generator A.Cause of Tube Failure Will Be Evaluated
ML20071F08625 September 1980Ro:On 800912,sample Analysis Taken from Hydrazine Addition Tank Indicated Sodium Chloride in Tank.Anonymous Telcon Indicated Salt May Have Been Added Prior to Labor Strike by Unknown Persons
ML20077B47310 May 1991Ro:On 910507,operator Failed to Perform Surveillances & Channel Tests for All 6 Scram Channels & 2 Interlocks Prior to Reactor Operation.Caused by Personnel Error. Tailgate Meeting Held & Mods to Hardware Initiated
ML20083Q03116 August 1972Ro:Problem W/Electromatic Relief Valve Discovered During Annual Insp Outage.Info Re Leakage Detailed in . Weld Sealed Instead of Stitch Welded.Valve Fully Operable
ML20083Q0352 June 1972Ro:Problem W/Electromatic Relief Valves Disclosed During Annual Insp Outage.Caused When Locking Screw,Part 8,on 6-inch Consolidated Electromatic Relief Valve Came Unscrewed
ML20083Q95322 November 1972Ro:On 721111,during Plant Cooldown Following Reactor Scram,A Isolation Condensor Did Not Isolate Upon Actuation & Condensate Return Valve V-14-37 Did Not Open After B Condensor Isolated.Condensate Steam Line Sensors Repiped
ML20083Q95622 August 1972Ro:On 720809,during Plant Cooldown,Isolation Condensors Would Not Operate.Caused by Needle on Differential Pressure Gauge Caught on Indicator Overtravel Stop.Needle RemovedOvertravel
ML20083Q96711 August 1972Ro:On 720804,during Routine Surveillance,Isolation Condensor Steam Line High Flow Differential Pressure Instrument Failed to Trip at Normal Trip Point.Caused by Loss of Tongue Tube Preload.New Bellows Assembly Installed on Switch
ML20084B6707 June 1972Ro:On 720529,four Hanger Bolts for Torus Suction Header Found Failed.Cause Under Investigation.Ge Planning to Install 20 Vibration Detecting Sensors & Conduct Tests to Monitor Containment Sys Vibration & Torus MovementLiquid penetrant
ML20084B67629 May 1972Ro:On 720529,torus Suction Header Discovered to Have Hanger Damage & Was Displaced from Normal Position.Caused by Four Hanger Bolts Failing.Reactor Shut Down.Cause Under Investigation
ML20084B69130 May 1972Ro:On 720529,torus Suction Header Discovered to Have Hanger Damage & Was Displaced from Normal Position.Caused by Four Hanger Bolts Failing.Cause Under Investigation
ML20084B74623 June 1972Ro:On 720525,loss of Auxiliary Power Test Conducted.Review of Test Revealed Power Supply for Bus 28/29-5 Transferred Automatically from Bus 29 to 28.Caused by Wiring Error
ML20084B75924 May 1972AO 2-72-9:on 720524,essential Svc Motor Generator Set Failed to Transfer from Normal Ac Supply to Backup Dc Supply.Feed Water Control Sys Inoperable Resulting in Low Reactor Water Level Scram
ML20084D01011 June 1974Telecopy Message of Ro:On 740611,8 of 31 Bergen-Paterson Hydraulic Piping Restraints within Drywell Found Defective. Caused by Loss of Hydraulic Fluid & Vibration of Cleanup Sys Header within Drywell.Repairs Initiated
ML20084D01811 June 1974Telecopy Message of Ro:On 740611,8 of 31 Bergen-Paterson Hydraulic Piping Restraints within Drywell Found Defective. Caused by Loss of Hydraulic Fluid & Vibration of Cleanup Sys Header within Drywell.Repairs Initiated
ML20084D04013 February 1974Telecopy Message of Ro:On 740211,12 of 31 Bergen-Paterson Hydraulic Piping Restraints within Drywell Found Defective Caused by Loss of Hydraulic Fluid.Restraints to Be Overhauled
ML20084D97817 July 1973Ro:On 730219,three Control Rod Drives Apparently Uncoupled When Withdrawn During Startup.Control Rod Drives Rebuilt. Postulated Sequence of Events Resulting in Possible Uncoupling Based on Finding One Inner Filter DisconnectedOvertravel
ML20084D99313 March 1973Ro:On 730219,three Control Rod Drives Apparently Uncoupled When Withdrawn During Startup.Cause Will Be Determined During Next Outage.Rept of Disassembly & Insp Findings to Be Submitted on 730430Overtravel
ML20084E5679 July 1971Ro:On 710630,MSIV Failed to Close on Signal.Solenoid Operators on MSIV 1A Removed & Inspected and All Parts
ML20084E85614 October 1970Ro:On 701004,core Deluge Valve 852B Malfunctioned.Caused by Seizure of Stem Nut to Valve Stem.New Stem Nut Installed
ML20084E91814 April 1972Telecopy of RO 1-72-6:during Startup Test on Unit 1 Diesel Generator,Unit Failed to Operate Due to High Crankcase Pressure
ML20084G16014 October 1969Ao:On 691002,startup Test Program Did Not Meet Insertion Times of Control Rods.Wire Mesh Will Be Removed,External Filters Will Be Exchanged & Scram Insertion Times Will Be Monitored
ML20084H33524 December 1969Ro:Rise in Rate of Pressure for MSIV Observed & Shutdown Planned by 700201 to Retest Valves
ML20084K74119 September 1974Telecopy Ro:On 740913,plant Shut Down to Investigate Source of Unidentified Leak in Drywell.Caused by Small Crack Through Pipe Wall in 4-inch Bypass Line on B-recirculation Loop.Ge Investigation InitiatedSafe Shutdown
ML20084K77313 September 1974Telecopy Ro:On 740913,unit Shut Down Upon Discovery of Leak on 2B Recirculation Pump Loop at Junction of Discharge Line & Recirculation Loop Between Pump & Discharge Valve. Investigation ContinuingTime of Discovery
ML20084Q9856 December 1969Ro:On 691120,one Rod Failed to Scram within Tech Spec Limit of 5.32 Seconds.Other Control Rods Took Excessive Time to Scram.No Cause Stated.Different Size Mesh Inner Rod Drive Strainers Installed
ML20084T78923 July 1970Ro:On 700603,two MSIV Valve Closure Times Exceeded Tech Spec Requirements.Closure Times Readjusted.Importance of Test Data Rapid Analysis & Transmittal to Operating Personnel & Mgt re-emphasized
ML20084T89912 June 1970Ro:On 700605,turbine Tripped & Reactor Scram Occurred.Caused by Spurious Control Sys Signal.Following Reactor Scram, Safety Valves Inadvertently Opened.Two Valves Failed to Close Fully Releasing Primary Coolant to Containment
ML20084T97922 June 1970Telecopy Ro:On 700605,safety Valves Actuated Following Turbine Trip & Scram
ML20085E9534 July 1975Telecopy Message of Ro:On 750703,facility Became Inoperable Due to Governor Problems.Manual Operation Possible.Lee Gas Turbine Could Not Be Tied in Through Isolated Line to Supply & Buy Power.Investigation Continuing
ML20085G96622 December 1973RO 50-293/73-21:on 731203,HPCI Inverter Failed.Caused by Increasing Dc Battery Sys a Voltage to 140 Volts.Station Personnel Advised Against Increasing Voltage Above 135 Volts & Caution Tags Placed on Battery Chargers
ML20085K06327 December 1973Ro:On 731208,during Routine Surveillance,Hpci High Flow Switch DPIS 3-2353 Operated at 25 Inches of Water Above Limit.Caused by Friction on Dial Indicator.Excess Slack of Wires Inside Switch Reduced
ML20085M39529 October 1973Ro:Describing Possible Backseating Disc Mislocation Problem on 2-inch Darling Valves on S-350 Wdd Welding End.Valves Repaired.Valve Stems Will Be Changed During Next Refueling Outage
ML20086B14329 October 1971Ro:On 710514,0819 & 0924,reactor Trip Breakers Failed to Open When Trip Signal Applied.After Investigation, Westinghouse Determined Undervoltage Device Latch Spring Pressure Improperly Set.Devices Adjusted
ML20086D5146 January 1978Telecopy Ro:On 780105,discovered That One of Two Nuclear Engineering Co Model B3-1 Shipping Casks Provided w/1-inch Diameter Lid Bolts Rather than 1-1/4 Inch Size Specified in Certificate of Compliance 6058
ML20086D52014 December 1977Telecopy Ro:Heating Steam Coil Leak in Reactor Bldg Ventilation Supply Unit V-AH-4A Resulted in Freezing of Condensate at Inlet to Unit & Subsequent Inoperability of Associated Secondary Containment Isolation Dampers
ML20086D53714 October 1977Telecopy Ro:Insp of Internal Torus Catwalk Support Structure Revealed That Catwalk Mitered Sections Not All Attached to Horizontal Catwalk Support Plates in Some Manner.Attachment Locations Will Be Upgraded
ML20086D55013 October 1977Telecopy Ro:On 771012,local Leak Rate Testing of MSIV AO-2-80A & Nitrogen Instrument Air Sys Isolation Valve CV-7436 Indicated That Leakage Exceeded Tech Spec Acceptance Criteria.Cause Under Investigation
ML20086D5545 October 1977Telecopy Ro:On 771004,local Leak Rate Testing of HPCI Sys Discharge Isolation Check Valve HPCI-9 Indicated That Leakage Exceeded Tech Spec Acceptance Criteria.Cause Under Investigation