ML17317A9265 February 1979LER 79-003/03L-0 on 790106:reactor Trip/Safety Injection Occurred.Caused by Freezing of Steam Generator/Main Steam Pressure Sensing Lines.Freezing Due to Failure to Close Off Steam Vent Openings in West Steam Encl
ML17317A9309 February 1979LER 79-001/03L-0 on 790122:during Mode 1,position of Rod F-6 Showed Deviation of Greater than 12 Steps from Demand Position.Caused by Drift in Signal Conditioning Module
ML17317A94313 February 1979LER 79-004/01T-0 on 780802:turbine Low Fluid Oil Pressure Switches Set at non-conservative Value.Initially Calibr at Vendor'S Recommended Setpoints;Were Not Recalibr Per Tech Specs
ML17317A94413 February 1979LER 79-005/03L-0 on 790117:solid State Protection Sys Tested Unsatisfactorily.Caused by Failure of Universal Logic Card A-214
ML17317A94513 February 1979LER 79-006/03L-0 on 790123:svc Water Supply Check Valve to AB diesel,ESW-143,failed to Seat.Caused by Normal Wear of Split Center Disc of Carbon Steel Check Valve,Centerline Part D-10495-26
ML17317A94812 February 1979LER 79-002/03L-0 on 790112:following Boric Acid Injection, Axial Flux Difference Exceeded Tech Spec Limit.Cause UnknownBoric Acid
ML17317A95927 February 1979LER 78-069/03L-0 on 781010:axial Flux Difference Monitoring Alarm Point Discovered Set Above Tech Spec Max.Caused by Raising of Alarm Trip Point During Preoperational Test Failure to Return to Required Value at End
ML17317A96027 February 1979LER 79-003/03L-0 on 790120:during Review of Completed Surveillance Tests,Discovered That Test on Solid State Protection Sys Train a Exceed 1-h Limit Imposed by Tech Specs.Caused by Technician Overlooking 1-h Limit
ML17317A96228 February 1979LER 79-004/03L-0 on 790206:both Doors of Containment Airlock Were Inadvertently Opened.Caused by Interlock Cable Being Too Loose to Operate Locking Mechanism.Tension Was Adjusted & Interlock Then Tested Satisfactorily
ML17317A9847 March 1979LER 79-005/03L-0 on 780624:unit Was Operated W/Positive Moderator Temp Coefficient for 3-h.Caused by Rod Withdrawal & Consequent Xe Build Up.Procedure Being Revised
ML17317A9857 March 1979LER 79-006/03L-0 on 790208:pressurizer Relief Tank Diaphragm Ruptured,Causing Ice Condenser Inlet Doors to Be Indicated Open.Caused by Pressure Surge in Lower Containment.Unit Shut Down & Doors Closed
ML17317B00113 March 1979LER 79-007/03L-0 on 790213:during Surveillance Test on Containment Pressure Set 3,high-high Bistable Trip Point Was Found to Exceed Tech Specs.Caused by Drifting Bistable. Bistable,Westinghouse Model 63V-BC-OHEA-F,was Replaced
ML17317B00513 March 1979LER 79-007/03L-0 on 790218:suction Valve of West Centrifugal Charging Pump Found Closed.Caused by Mistaken Closing Following Surveillance Testing.Incident Is Being Reviewed
ML17317B00613 March 1979LER 79-008/03L-0 on 790207:containment Atmospheric Air Particulate & Gaseous Radiation Monitoring Sys Pump Was Continuously Tripping.Caused by Misalignment of Pump Bypass Flow Adjustments Due to Normal Pump Wear.Flow Rate Adjusted
ML17317B00713 March 1979LER 79-009/03L-0 on 790223:in Mode 1 Both Emergency Diesel Generators Were Inoperable on Separate Occasions.Caused by AB Diesel Generator Running in Parallel & Other Emergency Generator Out for Maint.Operating Procedures Revised
ML17317B03020 March 1979LER 79-010/03L-0 on 790203:diesel Essential Svc Water Check Valves 1-ESW-111 & 1-ESW-114 Did Not Function Properly. Caused by Excessive Wear at Split Disc Hinge Points.Discs Replaced & Maintenance Insp Procedures Revised
ML17317B03120 March 1979LER 79-011/03L-0 on 790223:auxiliary Feedwater Discharge Valve Would Not Close from Control Room.Caused by Loose Connection in Hot Shutdown Panel.Connection Tightened & Correct Valve Operation Verified
ML17317B03220 March 1979LER 79-012/03L-0 on 790226:containment Air Monitor Pump Overheated.Caused by Worn Rubber Spider in Lovejoy L-100 Coupling.Spider Replaced & Air Sampler Retested
ML17317B03320 March 1979LER 79-013/03L-0 on 790303:auxiliary Feed Valve FMO-212 Would Not Shut from Control Room.Caused by Broken Wire in Valve'S Motor Operator.Breakage Is a Result of Vibration & Use of Solid Conductor Wire.Wire Replaced
ML17317B04628 March 1979LER 79-008/03L-0 on 790303:main Turbine Stop Valve C Closure Limit Switch Failed Conservatively (Closure Indication Received).Cause Unknown.Switch Replaced
ML17317B04928 March 1979LER 79-014/03L-0 on 790301:while in Mode 1,indicated Position of Rod F-6 Discovered to Be Oscillating within 15 Steps of Bank Demand Position.Caused by Signal Conditioning Module Connector.Cleaning & Reinstallation Corrected Limits
ML17317B05028 March 1979LER 79-015/03L-0 on 790302:while Operating at Full Power, Pressurizer Relief Tank Rupture Disc Blew Out,Causing Ice Condenser Inlet Doors to Open.Caused by Pressure Fluctuations Resulting in Weakened Rupture Discs
ML17317B0632 April 1979LER 79-009/03L-0 on 790303:2W Svc Water Pump Amp Pegged Meter Stopped,Constituting Inoperable Pump.Caused by Burr Formed Between Impeller Ring & Bowl.Pump Shaft & Bowl Replaced
ML17317B0663 April 1979LER 79-010/03L-0 on 790306:during Surveillance Test on Turbine Driven Auxiliary Feed Pump,Pump Was Over Max Recommended Temp.Possible Cause Was Foreign Matl in Bearing Oil.Oil Was Changed
ML17317B0693 April 1979LER 79-016/03L-0 on 790304:two Manual Containment Isolation Valves Were Inadvertantly Left Open Following Routine Sample of Instrument Room.Caused by Personnel Oversight.Both Valves Were Returned to Their Normally Closed Positions
ML17317B0703 April 1979LER 79-017/03L-0 on 790312:spent Fuel Pit Exhaust Ventilation Unit Flow Failed to Meet Acceptance Criteria. Caused by Slight Closing of Intake Grills Due to Sys Vibration.Grill Damper Linkage Securely Fastened
ML17317B0869 April 1979LER 79-018/03L-0 on 790310:root Valve for Lower Containment Pressure Transmitter PPP-300 Was Found in Closed Position. Cause Unknown.Valve Was Immediately Opened,Restoring Loop to Operable Status
ML17317B11217 April 1979LER 79-020/03L-O on 790323:pressurizer Relief Tank Rupture Disk Blew Out While in Mode 3.Caused by Repeated Pressure Fluctuations Causing Rupture Disk to Weaken.Corrective Action Unnecessary Since Doors Functioned as Designed
ML17317B11417 April 1979LER 79-021/03L-0 on 790327:pressure in RCS Was Found Below Tech Spec Limit While in Mode 1.Caused by Operator Inadvertantly Opening Auxiliary Spray Valve to Pressurizer QRV-51.Valve Closed Upon Discovery
ML17317B11817 April 1979LER 79-011/03L-0 on 790327:outer Door Seal of Lower Containment Air Lock Found Leaking.Caused by Force Placed on Seal During Installation of Security Gate at Air Lock Entrance.Seal Tightened & Outer Seal Retested
ML17317B13824 April 1979LER 79-023/03L-0 on 790326:portion of Circuitry for Rod K-10 Indication Was Shorted Rendering Channel Inoperable.Caused by Shorting Secondary Coil Voltage Terminals to Line Voltage Terminals at Rear of Indicator Panel.Measurement Revised
ML17317B13924 April 1979LER 79-024/03L-0 on 790326:indicated Position for Rod F-6 Exceeded Twelve Step Limit Imposed by Tech Specs, & Problem Recurred Four More Times in Two Days.Investigation in Progress & Suppl Rept Will Be Submitted
ML17317B15327 April 1979LER 79-012/03L-0 on 790330:hydraulic Control Values Did Not Return to Normal Position Placing Hydraulic Lock on Operator Cylinder.Caused by Dirt in Hydraulic Pilot Valve.Hydraulic Fluid Replaced
ML17317B1612 May 1979LER 79-013/03L-0 on 790407:during Rapid Shutdown,Pressure Was Allowed to Drop to 2,190 Lb Psig.Caused by Spray Valve Which Was Slow to Respond.Spray Placed in Manual & Throttled Back
ML17317B16227 May 1979LER 79-014/03L-0 on 790404:on Two Occasions Rod Position Indication Exceeded 12-step Limit.Caused by Drifting of Signal Conditioning Modules,Which Were Adjusted for Proper Output
ML17317B1662 May 1979LER 79-026/03L-0 on 790406:during Normal operation,69/4kV Offsite Ac Electrical Supply Became Inoperable.Caused by High Winds During Severe Windstorm.Damaged Jumper Replaced & Sys Returned to Operable StatusHigh winds
ML17317B1672 May 1979LER 79-025/03L-0 on 790416:time Response Data Not Collected During Apr 1976 Refueling Outage for Low Steam Pressure Engineered Safety Feature Channel.Caused by Inadvertent Procedural Omission.Checklist Will Be Used in Future
ML17317B1717 May 1979LER 79-010/03X-1 on 790223:diesel Essential Svc Water Check Valves 1-ESW-111 & 1-ESW-114 Not Functioning Properly.Caused by Excessive Wear at Split Disc Hinge Points.Discs Replaced
ML17317B1859 May 1979LER 79-019/03L-0 on 790413:while Performing Hydraulic Snubber Surveillance Insp,Snubbers GBD-S573 & GBD-S574 Found W/Drained Reserviors.Caused by Loose Pipe Unions Between Snubbers & Remote Reservoirs.Snubbers Replaced
ML17317B1869 May 1979LER 79-027/03L-0 on 790416:during Refueling W/Emergency Diesel Generator AB inoperable,600 Volt Bus 11D Made Inoperable by Removal of Normal Feed Breaker T1112 for Cleaning.Caused by Personnel Error.Operators Reinstructed
ML17317B1879 May 1979LER 79-028/03L-0 on 790410:torque Required to Open Lower Ice Condenser Inlet Door 3-R Exceeded Tech Specs.Caused by Sheet Metal Screws Loose at Bottom of Door.Door Frame Edge Depressed
ML17317B1909 May 1979LER 79-015/03L-0 on 790409:during Plant Startup,Small Crack & Pinhole Leak Found in Body of FMO-232,at Inlet Side of Valve Adjacent to Weld.Cause of Crack Not Determined. Radiographs of Area ReviewedHydrostatic
ML17317B1919 May 1979LER 79-016/03L-0 on 790412:failure of Interlock,Which Prevents Opening Both Containment 650 Ft Level Airlock Doors.Caused by Slack in Actuator Cables & Weak Spring.One Cable & Spring Replaced
ML17317B20714 May 1979LER 79-029/03L-0 on 790414:cracks Discovered in Divider Barrier Seal.Caused by Excessive Compression of Seal Matl by Steel Plates.Work in Progress to Replace Cracked Sections
ML17317B21016 May 1979LER 79-030/03L-0 on 790417:while Performing Routine Surveillance Test on AB Diesel Generator,Load Conservation Circuitry Did Not Fully Function as Design.Cause Under Investigation
ML17317B21116 May 1979LER 79-031/03L-0 on 790419:during Routine Channel Calibr, Bistable Trip Value Discovered Nonconservative W/Respect to Tech Spec Limits.Caused by Excess Drift.Bistable Will Be Repaired
ML17317B21216 May 1979LER 79-032/03L-0 on 790416:during Routine Channel Calibr, Bistable FB-510B Trip Point Was Nonconservative W/Respect to Tech Spec Limit.Caused by Excess Drift.Bistable Recalibr
ML17317B21516 May 1979LER 79-017/03L-0 on 790423:while Performing STP 022, Essential Svc water-142, Essential Svc Valve to 2 Cd Diesel Did Not Seat Properly.Caused by Excessive Wear of Split Disc Hinge Points.Stainless Steel Discs Were Substituted
ML17317B24123 May 1979LER 79-018/03L-0 on 790423:during Investigation of Periodic Alarms for Steam Generator High Steam Line Flow,Controller 2 Py 506B (Turbine Impulse Pressure) Was in Manual Control. Caused by Controller Not Being Returned to Automatic
ML17317B2544 June 1979LER 79-033/03L-0 on 790308:monthly Functional Tests for Containment Area Monitor,Containment atmosphere-particulate & Containment atmosphere-gaseous Monitors Were Not Performed.Caused by Daily Assignment Error