05000315/LER-1979-024-03, /03L-0 on 790326:indicated Position for Rod F-6 Exceeded Twelve Step Limit Imposed by Tech Specs, & Problem Recurred Four More Times in Two Days.Investigation in Progress & Suppl Rept Will Be Submitted

From kanterella
(Redirected from ML17317B139)
Jump to navigation Jump to search
/03L-0 on 790326:indicated Position for Rod F-6 Exceeded Twelve Step Limit Imposed by Tech Specs, & Problem Recurred Four More Times in Two Days.Investigation in Progress & Suppl Rept Will Be Submitted
ML17317B139
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 04/24/1979
From: Beilman T
INDIANA MICHIGAN POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML17317B132 List:
References
LER-79-024-03L, LER-79-24-3L, NUDOCS 7904300305
Download: ML17317B139 (2)


LER-1979-024, /03L-0 on 790326:indicated Position for Rod F-6 Exceeded Twelve Step Limit Imposed by Tech Specs, & Problem Recurred Four More Times in Two Days.Investigation in Progress & Suppl Rept Will Be Submitted
Event date:
Report date:
3151979024R03 - NRC Website

text

U. S. NUCLEAR REGULATORY COMMISSION NRC FORM 366 (7.77)

LICENSEE EVENT REPORT 3

~

CONTROL'LOCK:

QI (PLEASE PRINT OR TYPE ALLREQUIRED INFORMATION)

I 6

~oc N

I 0

C C

1 Q3 0

0 0

0 0

0 0

0 0

0 0 0 A

1 1

1 1 O~Os 7

8 9

LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE 30 57 CAT 58 4

CON'T

~o1

~LQB 0

5 0

0 0

3 1

5Q7 0

3 2

6 7

9 Qs O

4 2

4 7

9 QB DOCKET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES Q10 0

2 WHILE IN MODE 1

'THE INDICATED POSITION OF ROD F 6 WAS DISCOVERED TO HAVE

~o3 EXCEEDED THE TWELVESTEP LIMIT IMPOSED BYT.S.3.1.3.2

~ DURING THE TWO 4

DAYS SUBSEQUENT TO THE FIRST OCCURRENCE, THE PROBLEM RECURRED FOUR ADDITIONAL TIMES.

~OB

~O7

~os 80 7

8

~Os 7

8 WILL BE SUBMITTED UPON ITS COMPLETION.

SYSTEM

CAUSE

CAUSE COMP VALVE CODE CODE SUBCODE COMPONENT CODE SUBCODE SUBCODE

~IE Q11 N

Q12

~N Q13 I

N S

T R

0 Q14

~O>> ~ Ols 9

10 11 12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT REVISION 21 22 23 24 26 '7 28 29 30 31 32 ACTION FUTURE EFFECT SHUTDOWN ATTACHMENT NPRDQ PRIME COMP.

COMPONENT TA N

A ION ONP NT MET OD HOURS +22 SUBMITTED FORM SUB.

SUPPLIER MANUFACTURER pJQ13 ~Qls

~Q33

~Q31 Q33

~Q34

~Q33 N

1 2

0 Q33 33 34 35 36, 37 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS Q27 o

THE INVESTIGATION IS CURRENTLY IN PROGRESS AND A SUPPLEMENTAL REPORT 1~1.

3 4

DISCOVERY DESCRIPTION Q2 OBSERVATION I.OCATION OF RELEASE Q 44 7 '/O0 3 E7OEI7S 7

8 9

FACILITY

~3P METHOD OF STATUS

% POWER OTHER STATUS ~

DISCOVERY

~15 E

Qss ~l0 0

Qss NA

~AQ31 OPERATOR 7

8 9

10 12 13 44 45 46 ACTIVITY CONTENT RELEASED OF REI.EASF AMOUNTOF ACTIVITYQ Q33

~ZQ34 NA' 8

9

'IO 11 45 PERSONNEL EXPOSURES NUI'ABER TYPE DESCRIPTION Q3B 1

~00 0

Q31 ~EQ38:,.NA 7

8 9

11 12 13 PER BONN E L IN 3 UR I ES 80 80 80 80 7

8 9

8 O

7 8

9 11 12 LOSS OF OR DAMAGETO FACILITYQ43 9

10 PUB LI CITY ISSUED DESCRIPTION~

9 10 T.

P.

Beilman NAME OF PREPARER 80 80 NRC USE ONLY ss 80 g 0

68 69 P HoNE 6 1 6 4 65 5 9 0 1

fj II