ML20207H865 | 24 July 1988 | Notice of Violation from Insp on 830711-840109.Violations Noted:Fire in Auxiliary Shutdown Panel Room Could Have Resulted in Loss of Control & Indications for Both Auxiliary Feedwater Pumps | Hot Short Safe Shutdown Fire Barrier Emergency Lighting Continuous fire watch Fire Protection Program Fire Watch |
ML20207S535 | 13 March 1987 | Notice of Violation from Insp on 861201-870131 | |
ML20210N934 | 30 April 1986 | Notice of Violation from Insp on 860114-0402 | Loop seal Condition Adverse to Quality |
ML20210P798 | 6 August 1999 | Notice of Violation from Insp on 980901-990513.Violations Noted:Prior to 980901,licensee Inadvertently Performed Field Change to Pressurizer Spray Valve RC-2,not Approved by Organization That Performed Original Design | Boric Acid Packing leak Condition Adverse to Quality |
ML20212P061 | 27 August 1986 | Notice of Violation from Insp on 860616-0731 | |
ML20213E177 | 5 November 1986 | Notice of Violation from Insp on Aug-Sept 1986 | |
ML20213E292 | 7 November 1986 | Notice of Violation from Insp on 860930,1001-03,07-09 & 14-17 | |
ML20214F270 | 8 May 1987 | Notice of Violation from Insp on 870201-0331 | Offsite Circuit |
ML20214X012 | 3 December 1986 | Notice of Violation from Insp on 860715-1030 | Condition Adverse to Quality |
ML20216D881 | 10 March 1998 | Notice of Violation from Insp on 980107-0218.Violation Noted:On 980106,during Performance of Procedure DB-SP-03357, Rev 01, RCS Water Inventory Balance, Step 4.1.10,RO Erroneously Closed RCP Seal Return Valve MU-38 | Hot Short Safe Shutdown |
ML20217C643 | 23 September 1997 | NOV from Insp on 970527-0707.Violation Noted:Operator Rounds Package Change Was Issued for Use W/O Superintendent, Operations or Designee Signature on Approval Page Attached to Master Reading Sheets | |
ML20217G878 | 1 October 1997 | Notice of Violation from Insp on 970707-0818.Violation Noted:Between May 1996 & June 1997,interim Measures Were Not Taken to Aid Operator Response Actions If Worst Case Circulating Water Linebreak Were to Occur | |
ML20234B107 | 11 September 1987 | Notice of Violation from Insp on 870810-14 & 19-21.Violation Noted:Licensee Spectroscopy Sys Failed to Identify & Quantify Cs-134,present in Liquid Waste Samples,At Concentration Greater than 5 X 10-7 Uci/Ml | |
ML20234C686 | 24 June 1987 | Notice of Violation from Insp on 870401-0531 | |
ML20235H165 | 9 September 1987 | Notice of Violation from Insp on 870601-0731.Violation Noted:Failure to Follow Procedures as Identified in Area of Operational Safety | |
ML20236F200 | 27 June 1998 | Notice of Violation from Insp on 980608-11.Violations Noted: Licensee Failed to Conduct Audits of Process Control Program & Implementation Procedures for Processing & Packaging Radwaste at Least Once Per 24 Months | Process Control Program |
ML20236G936 | 30 June 1998 | Notice of Violation from Insp on 980526-0617.Violation Noted:Record Reviews & Interviews Showed That Unescorted Access to Protected Area Granted to Two Security Officers W/O All Required Elements of Employment History | |
ML20236W231 | 28 July 1998 | Notice of Violation from Insp on 980512-0623.Violation Noted:As of 980522,established Measures Inadequate to Ensure That Design Basis of Containment Bldg Emergency Sump Correctly Translated Into Specifications | |
ML20245E056 | 21 April 1989 | Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $50,000.Violations Noted:On 881218,personnel Withdrew Group 3 Rods W/O First Inserting Regulating Rods 5- 7,thus Failing to Follow Steps Outlined in DB-PF-06203 | Rod Drop Event |
ML20245E064 | 24 February 1989 | Notice of Violation from Insp on 881201-890115.Violation Noted:Procedure DB-PN-00007 Not Implemented When Maint Planner Failed to Review Necessary Drawings for safety- Related Groups 3 & 4 CRD Programmer Drawer | |
ML20245J077 | 24 February 1989 | Notice of Violation from Insp on 890123-0206.Violation Noted:Semiannual Radioactive Effluent Release Rept for Jan-June 1988 Did Not Identify & Quantify Abnormal Gaseous Release Event on 880120 | |
ML20245J997 | 22 September 1988 | Notice of Violation from Insp on 880504-0802.Violation Noted:Failure to Ensure That Only Work Specified in Maint Work Package Performed & Several QC Certified Inspectors Did Not Complete Qualification Cards | Condition Adverse to Quality |
ML20246C461 | 17 August 1989 | Notice of Violation from Insp on 890605-0716 & 24.Violations Noted:Failure to Follow Provisions of Tech Spec 3.0.3 While Both Trains of Control Room Emergency Ventilation Sys Inoperable During Mode 1 | |
ML20246K761 | 5 May 1989 | Notice of Violation from Insp on 890313-17 & 0418.Violation Noted:Failure to Prescribe Need for Fire Brigade Assistance Upon Receipt of Alarm in Control Room.Failure to Establish Continuous Fire Watches within 1 H,Per Tech Spec 3.7.10.a | Fire Protection Program |
ML20246N765 | 22 March 1989 | Notice of Violation from Insp on 890116-0228.Violation Noted:Radioactive Fluid Leak Reduction Program Outside Containment Not Implemented & Maintained & Grab Samples Not Taken of Radioactive Gas Releases | Grab sample |
ML20248B162 | 26 May 1998 | Notice of Violation from Insp on 980427-30.Violation Noted: No Surveys Performed by Licensee on 980421 to Identify Potential for High Dose Rates in Anulus Area During Incore Detector Movement,Prior to Allowing Workers to Enter Area | |
ML20248M311 | 9 June 1998 | Notice of Violation from Insp on 980422-0507.Violation Noted:Condition Adverse to Quality Not Promptly Identified & Corrected,In That on 980515,potential Condition Adverse to Quality Rept Not Initiated After Unauthorized Wire Brush | Condition Adverse to Quality |
ML20249A606 | 11 June 1998 | Notice of Violation from Insp on 980401-0512.Violation Noted:Before 980415,Procedures DB-OP-06230 & DB-OP-03011 Were Not Appropriate to Circumstances Due to Not Providing Instructions for Manipulting Valves as Listed |