Semantic search

Jump to navigation Jump to search
 Issue dateTitleTopic
IR 05000335/200600525 January 2007IR 0500033506-005, 05000389-06-005; 10/01/2006 - 12/31/2006; St. Lucie Nuclear Plant, Units 1 & 2; Problem Identification and Resolution of Problems; Radiation Monitoring Instrumentation and Protective Equipment; and Radioactive Gaseous andBoric Acid
High Radiation Area
Ultimate heat sink
Offsite Dose Calculation Manual
Internal Flooding
Significance Determination Process
Operability Determination
Annual Radiological Effluent Release Report
Substantial potential for overexposure
Power change
Downpower
IR 05000335/200600627 July 2006IR 05000335-06-006, IR 05000389-06-006 Completed on 05/19/2006 for St. Lucie, NRC Security Inspection ReportFitness for Duty
Significance Determination Process
Affidavit
IR 05000335/200600724 November 2006IR 05000335-06-007, 05000389-06-007, Safeguards Information RemovedAffidavit
IR 05000335/20060083 October 2006IR 05000335-06-008 and IR 05000389-06-008; Florida Power & Light Company (Fpl); 08/07-25/2006; St Lucie Nuclear Plant, Unit 1 & 2Scaffolding
IR 05000335/200640118 January 2007NRC Inspection Report 05000335-06-401 and 05000389-06-401Affidavit
IR 05000335/200700226 April 2007IR 05000335-07-002, 05000389-07-002; on 01/01/2007 - 03/31/2007; St. Lucie Nuclear Plant, Units 1 & 2; Post Maintenance Testing: Problem Identification and Resolution of Problems; and Event FollowupUnanalyzed Condition
Boric Acid
Ultimate heat sink
Stroke time
Coatings
Significance Determination Process
Operability Determination
Power change
Operability Assessment
IR 05000335/200700319 July 2007IR 05000335-07-003, 05000389-07-003, on 04/01/2007 - 06/30/2007; St. Lucie Nuclear Plant, Units 1 & 2; Problem Identification and Resolution of ProblemsHigh winds
High Radiation Area
Ultimate heat sink
Internal Flooding
Coatings
Significance Determination Process
Operability Determination
Control of Heavy Loads
Deep Dose Equivalent
Fire Protection Program
IR 05000335/200700423 October 2007IR 05000335-07-004 & IR 05000389-07-004, on 07/01/2007 - 09/30/2007, St. Lucie Nuclear Plant, Units 1 & 2; Event FollowupBoric Acid
Time of Discovery
High winds
Ultimate heat sink
Significance Determination Process
Job Performance Measure
Operability Determination
IR 05000335/20070051 February 2008IR 05000335-07-005 & 05000389-07-005; Florida Power & Light Company; on 10/01/2007 - 12/31/2007; St. Lucie Nuclear Plant, Units 1 & 2; Occupational Radiation Safety and Public Radiation Safety, NRC Integrated Inspection ReportBoric Acid
High Radiation Area
Offsite Dose Calculation Manual
Weld Overlay
Internal Flooding
Hydrostatic
Nondestructive Examination
Temporary Modification
VT-2
Locked High Radiation Area
Significance Determination Process
Foreign Material Exclusion
Process Control Program
Operability Determination
Liquid penetrant
IR 05000335/20070065 November 2007IR 05000335-07-006, 05000389-07-006, on 08/27/2007 - 08/31/2007, 10/10/2007 - 10/14/2007, 10/24/2007 - 10/28/2007; St. Lucie Nuclear Plant, Units 1 and 2; Component Design Bases InspectionUltimate heat sink
Stroke time
Safe Shutdown Earthquake
Probabilistic Risk Assessment
Significance Determination Process
Job Performance Measure
Time Critical Operator Action
Battery sizing
Operability Assessment
IR 05000335/20074014 June 2007IR 05000335-07-401, 05000389-07-401, on 03/02/2007; St. Lucie, Units 1 and 2; and Notice of Violation, EA-06-092Safeguards Contingency Plan
IR 05000335/200740226 July 2007Transmittal Letter for St. Lucie Nuclear Plant - NRC Security Inspection Report 05000335/2007402 and 05000389/2007402 - SGI RemovedAffidavit
IR 05000335/200750114 March 2007Inspection Report No. 05000335-07-501 and 05000389-07-501, on 02/12/07 - 02/16/07, St. Lucie Nuclear PlantSiren
IR 05000335/20080013 March 2008Annual Assessment Letter - St. Lucie Nuclear Plant (NRC Inspection Report 05000335-08-001 and 05000389-08-001)B.5.b
IR 05000335/200800230 April 2008IR 05000335-08-002 and 05000389-08-002; Florida Power & Light Company; 01/01/2008 - 03/31/2008; St. Lucie Nuclear Plant, Units 1 & 2, NRC Integrated Inspection ReportSafe Shutdown
Fire Barrier
Fire impairment
Temporary Modification
Significance Determination Process
Pressure Boundary Leakage
Pressure boundary leak
Unidentified leakage
IR 05000335/200800317 July 2008IR 05000335-08-003, 05000389-08-003 on 06/30/08 for St. Lucie Nuclear PlantFire Barrier
Fire impairment
Temporary Modification
Significance Determination Process
Operability Determination
License Renewal
Control of Heavy Loads
Liquid penetrant
Pressure boundary leak
Downpower
Unidentified leak
IR 05000335/200800430 October 2008IR 05000335-08-004 & 05000389-08-004; on 07/01/2008 - 09/30/2008; St. Lucie Nuclear Plant, Units 1 & 2; Fire Protection and Other ActivitiesHigh winds
Fire Barrier
Internal Flooding
Fire impairment
Condition Adverse to Quality
Significance Determination Process
Operability Determination
License Renewal
Maintenance Rule Program
Downpower
Unidentified leakage
IR 05000335/200800530 January 2009IR 05000335-08-005, 05000389-08-005, October 1 to December 31, 2008, St. Lucie Nuclear Plant, Units 1 & 2, NRC Integrated Inspection ReportHigh Radiation Area
Ultimate heat sink
Offsite Dose Calculation Manual
Fire Barrier
Weld Overlay
Internal Flooding
Fire impairment
Temporary Modification
Finite Element Analysis
Significance Determination Process
Foreign Material Exclusion
Operability Determination
License Renewal
Dissimilar Metal Weld
DM weld
Unidentified leakage
Power Uprate
IR 05000335/200800825 August 2008IR 05000335-08-008, 05000389-08-008; on 07/097/2008 - 07/25/2008; St. Lucie Nuclear Plant, Units 1 & 2; Identification and Resolution of ProblemsStroke time
Coatings
Condition Adverse to Quality
IR 05000335/20083013 October 2008Er 05000335-08-301, 05000389-08-301, 07/23-25 and 07/28-30/2008 and 08/01/2008; St. Lucie Nuclear Plant, Licensed Operator ExaminationsDownpower
IR 05000335/20084012 April 2008NRC Office of Investigations Report No. 2-2006-034 - St. Lucie Nuclear Plant and NRC Security Inspection Report 05000335/2008401 and 05000389/2008401 (OUO Removed)
IR 05000335/200840315 October 2008IR 05000335-08-403, IR 05000389-08-403, Saint Lucie Nuclear Plant-NRC Physical Security Inspection ReportAffidavit
IR 05000335/200840429 January 2009IR 05000335-08-404, IR 05000389-08-404, on 09/12/2008, for St. Lucie, Notice of Violation (Cover Letter)
IR 05000335/200850128 March 2008IR 05000335-08-501, 05000389-08-501, on February 18-22, 2008, St. Lucie Nuclear Plant, Units 1 & 2; Baseline Inspection
IR 05000335/200900230 April 2009Errata - IR 05000335-09-002, 05000389-09-002, 05000335-09-501, 05000389-09-501, on January 1 to March 31, 2009, St. Lucie Units 1 & 2 - NRC Integrated Inspection ReportSignificance Determination Process
IR 05000335/200900329 July 2009IR 05000335-09-003, 05000389-09-003, on 04/01/2009 - 06/30/2009, St. Lucie, Units 1 & 2, Maintenance Risk Assessment and Emergent Work Control, Identification and Resolution of Problems, Other ActivitiesBoric Acid
High Radiation Area
Non-Destructive Examination
Offsite Dose Calculation Manual
Fire Barrier
Weld Overlay
Internal Flooding
Fire impairment
Locked High Radiation Area
Significance Determination Process
Annual Radioactive Effluent Release Report
Foreign Material Exclusion
Process Control Program
Operability Determination
License Renewal
Maintenance Rule Program
Pressure Boundary Leakage
Through Wall Leak
Incremental Core Damage Probability Deficit
Power change
Downpower
Unidentified leakage
IR 05000335/200900430 October 2009IR 05000335-09-004, 05000389-09-004 on 07/01/09 - 09/30/2009 for St. Lucie Nuclear Plant, Units 1 & 2Boric Acid
Fire Barrier
Fire impairment
Significance Determination Process
Operability Determination
License Renewal
Pressure Boundary Leakage
Downpower
Unidentified leakage
Unidentified leak
IR 05000335/200900521 January 2010IR 05000335-09-005 and 05000389-09-005, on 10/01/2009 - 12/31/2009; St. Lucie Nuclear Plant, Units 1 & 2; Identification and Resolution of ProblemsFire Barrier
Fire impairment
Temporary Modification
Significance Determination Process
Job Performance Measure
Operability Determination
License Renewal
Downpower
Unidentified leakage
IR 05000335/20090064 February 2010Notice of Category 1 Public Meeting with Florida Power and Light Company to Discuss Risk Significance of the Two Preliminary Greater than Green Inspection Report 05000335-09-006 and 05000389-09-006
IR 05000335/200900717 July 2009IR 05000335-09-007 & 05000389-09-007 on 01/26/09 - 01/30/09 and 02/09/09 - 02/13/09 for St. Lucie, Units 1 & 2, Triennial Fir ProtectionSafe Shutdown
Fitness for Duty
Fire Barrier
Enforcement Discretion
Operator Manual Action
Emergency Lighting
Condition Adverse to Quality
Significance Determination Process
Job Performance Measure
Hemyc
Maintenance Rule Program
Fire Protection Program
Hourly Fire Watch
IR 05000335/200930112 February 2010NRC Operator License Examination Report 05000335-09-301 and 05000389-09-301
IR 05000335/20093023 March 2010Er 05000335-09-302, 05000389-09-302, 01/11-14/2010 and 12/15/2009; St. Lucie Nuclear Plant, Licensed Operator Examinations
IR 05000335/200940219 June 2009IR 05000335-09-402, IR 05000389-09-402, on 04/17/2009, Saint Lucie Nuclear Plant - NRC Physical Security InspectionAffidavit
IR 05000335/20094031 December 2009IR 05000335-09-403, IR 05000389-09-403, on 11/06/2009, St. Lucie Nuclear Plant - NRC Physical Security Inspection Report. Cover LetterSignificance Determination Process
Affidavit
IR 05000335/200940431 July 2009IR 05000335-09-404 and 05000389-09-404, on 07/20/2009 - 07/24/02009; St. Lucie Nuclear Plant, Units 1 and 2; SecurityAffidavit
IR 05000335/201000228 April 2010IR 05000335-10-002, 05000389-10-002; on 1/01/2010 - 3/31/2010; St. Lucie Nuclear Plant, Units 1 & 2; Identification and Resolution of Problems, Operability EvaluationsBoric Acid
Fire Barrier
Stroke time
Fire impairment
Temporary Modification
Condition Adverse to Quality
Significance Determination Process
Foreign Material Exclusion
Operability Determination
License Renewal
Maintenance Rule Program
Through-Wall Leakage
Power change
Downpower
Unidentified leakage
Power Uprate
IR 05000335/201000328 July 2010IR 05000335-10-003, 05000389-10-003; IR 07200061-10-001; on 4/01/2010 - 6/30/2010; St. Lucie Nuclear Plant, Units 1 & 2; Identification and Resolution of Problems; Other ActivitiesSafe Shutdown
Boric Acid
Packing leak
High Radiation Area
Offsite Dose Calculation Manual
Fire Barrier
Stroke time
Time to boil
Internal Flooding
Fire impairment
Temporary Modification
Locked High Radiation Area
Condition Adverse to Quality
Significance Determination Process
Foreign Material Exclusion
Large early release frequency
Operability Determination
License Renewal
Maintenance Rule Program
Pressure Boundary Leakage
Pressure boundary leak
Unidentified leakage
Unidentified leak
Power Uprate
IR 05000335/201000429 October 2010IR 05000335-10-004, 05000389-10-004; 07/01/2010-09/30/2010; St. Lucie Nuclear Plant, Units 1 & 2; Equipment Alignment, Identification and Resolution of Problems Other ActivitiesTime of Discovery
High Radiation Area
Ultimate heat sink
Offsite Dose Calculation Manual
Fire Barrier
Stroke time
Fire impairment
Met Tower
Temporary Modification
Condition Adverse to Quality
Significance Determination Process
Annual Radioactive Effluent Release Report
Annual Radiological Environmental Operating Report
Process Control Program
Operability Determination
Annual Radiological Effluent Release Report
Through Wall Leak
Scaffolding
Downpower
Flow Induced Vibration
Unidentified leakage
IR 05000335/201000527 January 2011IR 05000335-10-005, 05000389-10-005; 10/01/2010 - 12/31/2010; St. Lucie Nuclear Plant, Units 1 & 2; Identification and Resolution of Problems and Other ActivitiesBoric Acid
Non-Destructive Examination
Mission time
Fire Barrier
Weld Overlay
Internal Flooding
Fire impairment
Temporary Modification
Condition Adverse to Quality
Significance Determination Process
Job Performance Measure
Operability Determination
Moisture barrier
License Renewal
Liquid penetrant
GOTHIC
Unidentified leakage
IR 05000335/201000619 April 2010IR 05000335-10-006 and 05000389-10-006; on 03/01/2010 - 03/19/2010; St. Lucie Nuclear Plant, Units 1 and 2; Biennial Inspection of the Identification and Resolution of ProblemsCondition Adverse to Quality
Significance Determination Process
IR 05000335/201000717 November 2010Summary of Public Regulatory Performance Meeting with Florida Power and Light Company to Discuss Corrective Actions Associated with the Yellow Finding That Was Documented in the NRC Inspection Report IR 05000335-10-007Significance Determination Process
Operability Determination
IR 05000335/20100093 November 2010IR 05000335-10-009; 9/27/2010-9/30/2010; St. Lucie Nuclear Plant, Unit 1; Supplemental Inspection - Inspection Procedure (IP) 95002Non-Destructive Examination
Condition Adverse to Quality
Significance Determination Process
Design basis earthquake
Operability Determination
Maintenance Rule Program
Through Wall Leak
IR 05000335/201020123 December 2010IR 05000335-10-201 and 05000389-10-201; on November 15 - November 18, 2010; St. Lucie Plant Units 1 and 2; Target Set InspectionAffidavit
IR 05000335/201040419 August 2010IR 05000335-10-404 and 05000389-10-404 on 07/22/2010 for St. Lucie, Units 1 and 2 - NRC Physical Security Inspection ReportAffidavit
IR 05000335/201040514 January 2011IR 05000335-10-405 and 05000389-10-405, on December 16, 2010, St. Lucie Nuclear Plant, NRC Physical Security Inspection (Cover Letter)Significance Determination Process
Affidavit
IR 05000335/201050130 March 2010IR 05000335-10-501 and 05000389-10-501; Florida Power and Light Company; 02/22/210 - 02/26/2010; St. Lucie Plant, Units 1 and 2; Baseline Inspection
IR 05000335/20105039 March 2011NRC Emergency Preparedness Annual Inspection Report 05000335/2010503 and 05000389/2010503
IR 05000335/201100229 April 2011IR 05000335-11-002, 05000389-11-002, 05000335-11-501, 05000389-11-501; 01/01/2011 - 03/31/2011; St. Lucie Nuclear Plant, Units 1 & 2; Radiological Hazard Assessment and Exposure Controls; Other ActivitiesSafe Shutdown
Unanalyzed Condition
Boric Acid
High Radiation Area
Non-Destructive Examination
Offsite Dose Calculation Manual
Fire Barrier
Fire impairment
Locked High Radiation Area
Significance Determination Process
Foreign Material Exclusion
Operability Determination
License Renewal
Liquid penetrant
Through-Wall Leak
Fire Watch
Substantial potential for overexposure
Power change
Unidentified leakage
Siren
Overexposure
IR 05000335/201100328 July 2011IR 05000335-11-003 & 05000389-11-003, on 04/01/2011 - 06/30/2011, St. Lucie Nuclear Plant, Units 1 & 2, NRC Integrated Inspection ReportFire Barrier
Internal Flooding
Fire impairment
Temporary Modification
B.5.b
Missed surveillance
Significance Determination Process
Foreign Material Exclusion
Operability Determination
Severe Accident Management Guideline
Downpower
Unidentified leakage
IR 05000335/201100427 October 2011IR 05000335-11-004 & 05000389-11-004; Florida Power & Light Company; 07/01/2011 - 09/30/2011; St. Lucie Nuclear Plant, Units 1 & 2, NRC Integrated Inspection ReportHigh winds
Fire Barrier
Internal Flooding
Fire impairment
Significance Determination Process
Job Performance Measure
Foreign Material Exclusion
Operability Determination
Maintenance Rule Program
Unidentified leakage