GO2-82-037, Interim Deficiency Rept Re Reportable Conditions 177 Concerning Bulk Purchase Valves & 175 Wbg Radiographs.Next Rept Expected 820601.All Subsequent Repts Will Be Provided on Quarterly Basis Until Final Rept Is Filed | 12 April 1982 | Interim Deficiency Rept Re Reportable Conditions 177 Concerning Bulk Purchase Valves & 175 Wbg Radiographs.Next Rept Expected 820601.All Subsequent Repts Will Be Provided on Quarterly Basis Until Final Rept Is Filed | |
GO2-82-049, Interim Deficiency Rept Re Excessive Voltage Drop Due to Long Control Cable Length,Initially Reported 820511.Possible Corrective Actions:Number 10 Rather than 12 Size Wire Used & CPT Size for Interposing Relay Increased | 3 June 1982 | Interim Deficiency Rept Re Excessive Voltage Drop Due to Long Control Cable Length,Initially Reported 820511.Possible Corrective Actions:Number 10 Rather than 12 Size Wire Used & CPT Size for Interposing Relay Increased | Safe Shutdown |
GO2-82-549, Suppl to Final Deficiency Rept Re Spray Pond Leakage, Initially Reported 810610.Const Joint Between Floor Slab Sections & Foundation Being Repaired.Expansion Joints Replaced | 21 June 1982 | Suppl to Final Deficiency Rept Re Spray Pond Leakage, Initially Reported 810610.Const Joint Between Floor Slab Sections & Foundation Being Repaired.Expansion Joints Replaced | Ultimate heat sink |
GO2-82-563, Final Deficiency Rept Re GE Control Switches Sbm & SB-9, Initially Reported 820303.SB-9 Switches Determined Not Reportable Per 10CFR50.55e.SBM Swithces Installed in Class IE Electrical Applications Replaced | 23 June 1982 | Final Deficiency Rept Re GE Control Switches Sbm & SB-9, Initially Reported 820303.SB-9 Switches Determined Not Reportable Per 10CFR50.55e.SBM Swithces Installed in Class IE Electrical Applications Replaced | |
GO2-82-574, Interim Deficiency Rept Re Concrete Expansion Anchor Program & Concrete & Grout Work.Evaluation Incomplete Due to Complexity of Interfacing Issues.Next Rept to Be Submitted by 820908 | 1 July 1982 | Interim Deficiency Rept Re Concrete Expansion Anchor Program & Concrete & Grout Work.Evaluation Incomplete Due to Complexity of Interfacing Issues.Next Rept to Be Submitted by 820908 | Safe Shutdown |
GO2-82-605, Final Deficiency Rept 179 Re Containment Penetration Piping/Valves.Initially Reported on 820218.Supply Sys Engineering Evaluation Rept Determined That Ae Properly Specified Temp for Piping & Valves | 13 July 1982 | Final Deficiency Rept 179 Re Containment Penetration Piping/Valves.Initially Reported on 820218.Supply Sys Engineering Evaluation Rept Determined That Ae Properly Specified Temp for Piping & Valves | |
GO2-82-676, Final Deficiency Rept Re Defect in 35-130-200 Battery Chargers Supplied by Power Conversion Products,Inc.Initially Reported on 820716.Replacement of 200 Ampere F1,F2 & F3 Fuses w/300 Ampere Fuses Recommended | 13 August 1982 | Final Deficiency Rept Re Defect in 35-130-200 Battery Chargers Supplied by Power Conversion Products,Inc.Initially Reported on 820716.Replacement of 200 Ampere F1,F2 & F3 Fuses w/300 Ampere Fuses Recommended | |
GO2-82-689, Interim Deficiency Rept Re Johnson Controls Design Issue. Initially Reported on 820720.Analysis of Large Bore Piping & Small Bore Design Underway.Next Rept Expected by 821123 | 18 August 1982 | Interim Deficiency Rept Re Johnson Controls Design Issue. Initially Reported on 820720.Analysis of Large Bore Piping & Small Bore Design Underway.Next Rept Expected by 821123 | |
GO2-82-727, Final Deficiency Repts Re Conditions 175,WBG Radiographs & 177,bulk Purchase Valves.Initially Reported on 811119 & 1208,respectively.All Quality Class I Welds Accounted For. Wbg Documentation Review of Bulk Purchase Valves Complete | 1 September 1982 | Final Deficiency Repts Re Conditions 175,WBG Radiographs & 177,bulk Purchase Valves.Initially Reported on 811119 & 1208,respectively.All Quality Class I Welds Accounted For. Wbg Documentation Review of Bulk Purchase Valves Complete | |
GO2-82-803, Advises That Deficiency Repts Re Electrical Cable Routing, Termination,Labeling,Power Supplies & QC Documentation Have Been Reopened.Interim Repts Will Be Provided by 821218 | 23 September 1982 | Advises That Deficiency Repts Re Electrical Cable Routing, Termination,Labeling,Power Supplies & QC Documentation Have Been Reopened.Interim Repts Will Be Provided by 821218 | |
GO2-82-806, Interim Deficiency Rept Re Improper Installation of Concrete Expansion Anchors & Unacceptable Concrete & Grout Work. Initially Reported on 820403.Corrective Actions Continuing. Next Rept Will Be Submitted on 821218 | 28 September 1982 | Interim Deficiency Rept Re Improper Installation of Concrete Expansion Anchors & Unacceptable Concrete & Grout Work. Initially Reported on 820403.Corrective Actions Continuing. Next Rept Will Be Submitted on 821218 | |
GO2-82-807, Final Deficiency Rept Re High Resistance Cable Grounding of 4.16 Kv Diesel Generators.Initially Reported on 820506. Manufacturers Advised That Equipment Can Operate for Indefinite Period w/line-to-ground Fault W/O Damage | 28 September 1982 | Final Deficiency Rept Re High Resistance Cable Grounding of 4.16 Kv Diesel Generators.Initially Reported on 820506. Manufacturers Advised That Equipment Can Operate for Indefinite Period w/line-to-ground Fault W/O Damage | |
GO2-82-819, Final Deficiency Rept Re 4.16 Kv Breakers DG 1-7 & DG 2-8 & Interim Deficiency Rept Re Emergency Diesel Generators DG-1 & DG-2 Airstart Circuits.Initially Reported on 820830 & 0908,respectively.Next Rept Will Be Submitted by 821220 | 30 September 1982 | Final Deficiency Rept Re 4.16 Kv Breakers DG 1-7 & DG 2-8 & Interim Deficiency Rept Re Emergency Diesel Generators DG-1 & DG-2 Airstart Circuits.Initially Reported on 820830 & 0908,respectively.Next Rept Will Be Submitted by 821220 | Safe Shutdown |
GO2-82-944, Interim Deficiency Rept Re Voltage Drop Due to Excessive Cable Length.Initially Reported on 820603.Control Power Transformer Output Increased.Voltage No Longer Impeded & Long Cable Used.Next Rept Expected by 830222 | 23 November 1982 | Interim Deficiency Rept Re Voltage Drop Due to Excessive Cable Length.Initially Reported on 820603.Control Power Transformer Output Increased.Voltage No Longer Impeded & Long Cable Used.Next Rept Expected by 830222 | Safe Shutdown |
GO2-82-945, Interim Deficiency Rept Re Controls for Remote Shutdown Panel & Pump Discharge Switch.Initially Reported on 820819 & 0820,respectively.Switches & Valves Will Be Relocated.Next Rept Will Be Submitted on 830228 | 23 November 1982 | Interim Deficiency Rept Re Controls for Remote Shutdown Panel & Pump Discharge Switch.Initially Reported on 820819 & 0820,respectively.Switches & Valves Will Be Relocated.Next Rept Will Be Submitted on 830228 | |
GO2-82-955, Deficiency Rept Re Johnson Controls Design Issue.Eight of 132 Small Bore Lines Did Not Meet Min Design Criteria Following Thermal Effects Application | 2 December 1982 | Deficiency Rept Re Johnson Controls Design Issue.Eight of 132 Small Bore Lines Did Not Meet Min Design Criteria Following Thermal Effects Application | |
GO2-82-989, Final Deficiency Repts 210 & 218 Re Deficient Emergency Diesel Generators DG-1 & 2 Airstart Circuits & MSIV Leak Control Sys,Respectively.Initially Reported 820830 & 1111. Silver Plated Contacts to Be Replaced in Airstart Circuits | 17 December 1982 | Final Deficiency Repts 210 & 218 Re Deficient Emergency Diesel Generators DG-1 & 2 Airstart Circuits & MSIV Leak Control Sys,Respectively.Initially Reported 820830 & 1111. Silver Plated Contacts to Be Replaced in Airstart Circuits | Safe Shutdown |
GO2-83-100, Final Deficiency Rept,Condition 291 Re Containment Atmospheric Control Valves Not Powered from Class IE Source. Initially Reported on 830929.Caused by Failure to Recognize Valves Have Two Safety functions.PED-218-E-C105 Issued | 2 November 1983 | Final Deficiency Rept,Condition 291 Re Containment Atmospheric Control Valves Not Powered from Class IE Source. Initially Reported on 830929.Caused by Failure to Recognize Valves Have Two Safety functions.PED-218-E-C105 Issued | |
GO2-83-101, Final Deficiency Rept,Condition 216 Re RHR Relief Valve Vents.Initially Reported on 821022.Relief Valves Removed, Eliminating Containment Leakage Path.Const in Progress on Physical Changes & Will Be Complete Prior to Fuel Load | 3 November 1983 | Final Deficiency Rept,Condition 216 Re RHR Relief Valve Vents.Initially Reported on 821022.Relief Valves Removed, Eliminating Containment Leakage Path.Const in Progress on Physical Changes & Will Be Complete Prior to Fuel Load | |
GO2-83-106, Final Deficiency Rept,Condition 286 Re Linear Indication on Containment Weld Pads.Initially Reported on 831014.Potential for Beam Seat Separation Under Worst Case Loads Nonexistent. Item Not Reportable Per 10CFR50.55(e) | 16 November 1983 | Final Deficiency Rept,Condition 286 Re Linear Indication on Containment Weld Pads.Initially Reported on 831014.Potential for Beam Seat Separation Under Worst Case Loads Nonexistent. Item Not Reportable Per 10CFR50.55(e) | |
GO2-83-109, Final Deficiency Rept,Condition 274 Re Excessive Gapping Between Pipe Support baseplates.Fifty-nine of 2,299 Baseplates Require Rework to Correct Deficient Baseplate Gap | 23 November 1983 | Final Deficiency Rept,Condition 274 Re Excessive Gapping Between Pipe Support baseplates.Fifty-nine of 2,299 Baseplates Require Rework to Correct Deficient Baseplate Gap | |
GO2-83-110, Final Deficiency Rept,Condition 296 Re Loose Internal Assembly Screws on GE Type Hfa Relays.Caused by Design or QC Deficiency by Relay Manufacturer.Also Reportable Under Part 21 | 29 November 1983 | Final Deficiency Rept,Condition 296 Re Loose Internal Assembly Screws on GE Type Hfa Relays.Caused by Design or QC Deficiency by Relay Manufacturer.Also Reportable Under Part 21 | |
GO2-83-111, Revised Final Deficiency Rept,Condition 51 Re Nonseismic Class 1 Digital Electrohydraulic Cabinets.Initially Reported on 810624.Reanalysis Concluded That Digital Electrohydraulic Cabinets Cannot Fall Over During DBE | 2 December 1983 | Revised Final Deficiency Rept,Condition 51 Re Nonseismic Class 1 Digital Electrohydraulic Cabinets.Initially Reported on 810624.Reanalysis Concluded That Digital Electrohydraulic Cabinets Cannot Fall Over During DBE | Safe Shutdown Earthquake |
GO2-83-113, Final Deficiency Rept,Condition 302 Re Mods Covering HPCS Second Level Undervoltage Protection Producing Potential Conditions for HPCS Pump to Fail to Start on Valid Initiation Signal.Design Revised | 9 December 1983 | Final Deficiency Rept,Condition 302 Re Mods Covering HPCS Second Level Undervoltage Protection Producing Potential Conditions for HPCS Pump to Fail to Start on Valid Initiation Signal.Design Revised | Safe Shutdown |
GO2-83-115, Final Part 21 Rept on Condition 295 Re Standby Gas Treatment Unit Charcoal Filter Bed Leakage.Initially Reported on 831115.Gaps Between Frame & Perforated Plates Sealed W/Ge Sealant 727 | 13 December 1983 | Final Part 21 Rept on Condition 295 Re Standby Gas Treatment Unit Charcoal Filter Bed Leakage.Initially Reported on 831115.Gaps Between Frame & Perforated Plates Sealed W/Ge Sealant 727 | |
GO2-83-116, Final Part 21 & Deficiency Rept Re Recombiner Scrubber Drainage Impaired by Design Configuration of Connections for Water Loop Seal & Process Blower on Recombiner Skid. Initially Reported on 831215 | 16 December 1983 | Final Part 21 & Deficiency Rept Re Recombiner Scrubber Drainage Impaired by Design Configuration of Connections for Water Loop Seal & Process Blower on Recombiner Skid. Initially Reported on 831215 | Loop seal |
GO2-83-117, Final Deficiency Rept,Condition 307 Re Target Rock Isolation Valve 82M-002 on Loop B Not Closing When Deenergized. Initially Reported on 831219.Twelve Valves Disassembled, Readjusted & Reinstalled Under Vendor Supervision | 20 December 1983 | Final Deficiency Rept,Condition 307 Re Target Rock Isolation Valve 82M-002 on Loop B Not Closing When Deenergized. Initially Reported on 831219.Twelve Valves Disassembled, Readjusted & Reinstalled Under Vendor Supervision | |
GO2-83-160, Final Deficiency Rept 190 Re Excessive Cable Length Causing Voltage Drop.Initially Reported on 820511.Control Power Transformer Increased from 300 VA to 500 VA to Preclude Voltage Drop | 22 February 1983 | Final Deficiency Rept 190 Re Excessive Cable Length Causing Voltage Drop.Initially Reported on 820511.Control Power Transformer Increased from 300 VA to 500 VA to Preclude Voltage Drop | Safe Shutdown |
GO2-83-174, Final Deficiency Rept on Conditions 208,209,223 & 229 Re Remote Shutdown Panel,Rhr & LPCS Pump Discharge Pressure Switches,Standby Liquid Control Sys & Missing Hangers in Turned Over HPCS Sys 7.1,respectively.Next Rept Due 830523 | 25 February 1983 | Final Deficiency Rept on Conditions 208,209,223 & 229 Re Remote Shutdown Panel,Rhr & LPCS Pump Discharge Pressure Switches,Standby Liquid Control Sys & Missing Hangers in Turned Over HPCS Sys 7.1,respectively.Next Rept Due 830523 | Safe Shutdown Earthquake |
GO2-83-188, Final Deficiency Rept Re Damage to Electrical Cable 2SM8- 0080 During Installation of Thermo Lag Fire Resistant Matl (Condition 235).Initially Reported on 830204.Damaged Cable Repaired.Condition Not Reportable Per 10CFR50.55(e) | 3 March 1983 | Final Deficiency Rept Re Damage to Electrical Cable 2SM8- 0080 During Installation of Thermo Lag Fire Resistant Matl (Condition 235).Initially Reported on 830204.Damaged Cable Repaired.Condition Not Reportable Per 10CFR50.55(e) | |
GO2-83-253, Interim Deficiency Rept Re Loss of ESF Loads on Under Voltage Trip.Initially Reported on 830228.Project Engineering Directive 218-E-4618 Issued to Implement Corrective Action.Next Rept Expected by 830624 | 24 March 1983 | Interim Deficiency Rept Re Loss of ESF Loads on Under Voltage Trip.Initially Reported on 830228.Project Engineering Directive 218-E-4618 Issued to Implement Corrective Action.Next Rept Expected by 830624 | Safe Shutdown |
GO2-83-313, Final Deficiency Rept Re Incorrect Wiring of Reactor Vessel Water Level Indicating Switches MS-LIS-37A & MS-LIS-37C. Initially Reported on 830315.Switches Rewired to Conform to GE Design Requirements | 6 April 1983 | Final Deficiency Rept Re Incorrect Wiring of Reactor Vessel Water Level Indicating Switches MS-LIS-37A & MS-LIS-37C. Initially Reported on 830315.Switches Rewired to Conform to GE Design Requirements | Reactor Vessel Water Level |
GO2-83-314, Interim Deficiency Rept Re balance-of-plant Board G-2 Design Error.Initially Reported on 830315.Drawing Part Lists Will Be Updated to Provide Correct Part Numbers.Next Rept Will Be Submitted by 830706 | 6 April 1983 | Interim Deficiency Rept Re balance-of-plant Board G-2 Design Error.Initially Reported on 830315.Drawing Part Lists Will Be Updated to Provide Correct Part Numbers.Next Rept Will Be Submitted by 830706 | Safe Shutdown |
GO2-83-333, Final Deficiency Rept Re Failure of Temp Control Modules WMA-TS-12A & 12B During Qualification Testing (Condition 238).Initially Reported on 830310.Printed Circuit Board Traces Replaced W/Wire Jumpers.Condition Not Reportable | 12 April 1983 | Final Deficiency Rept Re Failure of Temp Control Modules WMA-TS-12A & 12B During Qualification Testing (Condition 238).Initially Reported on 830310.Printed Circuit Board Traces Replaced W/Wire Jumpers.Condition Not Reportable | |
GO2-83-349, Part 21 Rept Re Linear Indications Identified in SA 106 Grade Pipe.Initially Reported on 830413.Caused by Mfg Process Error & Ultrasonic Exam Inadequacies.All Seamless Pipe Put on Hold & Magnetic Particle Examined | 15 April 1983 | Part 21 Rept Re Linear Indications Identified in SA 106 Grade Pipe.Initially Reported on 830413.Caused by Mfg Process Error & Ultrasonic Exam Inadequacies.All Seamless Pipe Put on Hold & Magnetic Particle Examined | |
GO2-83-353, Final & Interim Deficiency Repts Re Class IE Cables in Seismic Category 1 Raceways & Standby Gas Treatment Sys Damper.Next Rept by 830718 | 18 April 1983 | Final & Interim Deficiency Repts Re Class IE Cables in Seismic Category 1 Raceways & Standby Gas Treatment Sys Damper.Next Rept by 830718 | Safe Shutdown Earthquake |
GO2-83-358, Interim Deficiency Repts Re IE Circular 81-05, Sway Strut/ Snubber End Bushings & Anaconda Flexible Conduit.Initially Reported on 821202 & 830321,respectively.Quarterly Updates Will Continue to Be Provided.Next Rept Expected by 830720 | 20 April 1983 | Interim Deficiency Repts Re IE Circular 81-05, Sway Strut/ Snubber End Bushings & Anaconda Flexible Conduit.Initially Reported on 821202 & 830321,respectively.Quarterly Updates Will Continue to Be Provided.Next Rept Expected by 830720 | |
GO2-83-389, Interim Deficiency Repts on Condition 221 Re Namco EA-180 & EA-740 Limit Switches & Condition 226 Re 125-volt Dc Motor Operator Connected to 250-volt Dc Power Source.Next Rept by 830726 | 26 April 1983 | Interim Deficiency Repts on Condition 221 Re Namco EA-180 & EA-740 Limit Switches & Condition 226 Re 125-volt Dc Motor Operator Connected to 250-volt Dc Power Source.Next Rept by 830726 | |
GO2-83-436, Interim Deficiency Repts 216 & 223 Re Gaseous Release from RHR Relief Valve Vents & Inadequate Standby Liquid Control Sys,Respectively.Final Deficiency Rept 232 Re Improper Installation of RHR Support Pin Receptacle Also Encl | 17 May 1983 | Interim Deficiency Repts 216 & 223 Re Gaseous Release from RHR Relief Valve Vents & Inadequate Standby Liquid Control Sys,Respectively.Final Deficiency Rept 232 Re Improper Installation of RHR Support Pin Receptacle Also Encl | Safe Shutdown |
GO2-83-463, Final Deficiency Repts 229 & 254 Re Hangers Not Installed in Turned Over HPCS Sys 7.1 & Improper Installation of Lubrite Assemblies,Respectively.Interim Rept 251 Re Limitorque Motor Operators W/Motors Supplied by Baldor Encl | 23 May 1983 | Final Deficiency Repts 229 & 254 Re Hangers Not Installed in Turned Over HPCS Sys 7.1 & Improper Installation of Lubrite Assemblies,Respectively.Interim Rept 251 Re Limitorque Motor Operators W/Motors Supplied by Baldor Encl | Earthquake |
GO2-83-595, Final Deficiency Rept Condition 246 Re Balance of Plant Board G-2 Design Error.Initially Reported on 830315.AE Issued Project Engineering Directive (PED-218-E-B375) to Switch Power Supplies | 1 July 1983 | Final Deficiency Rept Condition 246 Re Balance of Plant Board G-2 Design Error.Initially Reported on 830315.AE Issued Project Engineering Directive (PED-218-E-B375) to Switch Power Supplies | Safe Shutdown |
GO2-83-610, Interim Deficiency Rept Re Reportable Condition 264, Concerning Improperly Sized Overcurrent Devices.Initially Reported on 830609.Pump & Valve Operator Motor Fuses Replaced.Fuse Size Verified.Next Rept by 831003 | 8 July 1983 | Interim Deficiency Rept Re Reportable Condition 264, Concerning Improperly Sized Overcurrent Devices.Initially Reported on 830609.Pump & Valve Operator Motor Fuses Replaced.Fuse Size Verified.Next Rept by 831003 | |
GO2-83-652, Revised Final Deficiency Rept for Condition 212 Re 8-H Rayproof Doors & Interim Deficiency Rept for Condition 262 Re Installation of Unapproved Power Piping Brackets.Next Rept Expected by 831021 | 22 July 1983 | Revised Final Deficiency Rept for Condition 212 Re 8-H Rayproof Doors & Interim Deficiency Rept for Condition 262 Re Installation of Unapproved Power Piping Brackets.Next Rept Expected by 831021 | |
GO2-83-654, Interim Deficiency Rept Item 221 & Final Deficiency Rept Item 251 Re Namco EA180 & EA740 Limit Switches & Limitorque Motor Operators W/Motors from Baldor Electric Co, Respectively.Initially Reported on 830104 & 0422 | 25 July 1983 | Interim Deficiency Rept Item 221 & Final Deficiency Rept Item 251 Re Namco EA180 & EA740 Limit Switches & Limitorque Motor Operators W/Motors from Baldor Electric Co, Respectively.Initially Reported on 830104 & 0422 | |
GO2-83-671, Interim Deficiency Rept of Condition 269 Re Bechtel Repair of Wrong Weld Area.Initially Reported on 830705.Const Manager Will Compare Radiograph from Repair W/Original to Ensure Correct Area Welded.Next Rept Expected by 831025 | 28 July 1983 | Interim Deficiency Rept of Condition 269 Re Bechtel Repair of Wrong Weld Area.Initially Reported on 830705.Const Manager Will Compare Radiograph from Repair W/Original to Ensure Correct Area Welded.Next Rept Expected by 831025 | |
GO2-83-742, Final Deficiency Repts Re Conditions 264 & 276 Concerning Improperly Sized Overcurrent Devices & Diesel Generator 1A Bearing Failure,Respectively.Initially Reported on 830609 & 0802.Pump & Valve Operator Motor Fuses Replaced | 18 August 1983 | Final Deficiency Repts Re Conditions 264 & 276 Concerning Improperly Sized Overcurrent Devices & Diesel Generator 1A Bearing Failure,Respectively.Initially Reported on 830609 & 0802.Pump & Valve Operator Motor Fuses Replaced | Safe Shutdown |
GO2-83-761, Final & Interim Deficiency Repts Re Conditions 223 & 260 Concerning Standby Liquid Control Sys & Standby Svc Water Flow Problems.Initially Reported on 830127 & 0721.Sys Will Be Modified Per Separation Criteria.Next Rept by 831101 | 11 August 1983 | Final & Interim Deficiency Repts Re Conditions 223 & 260 Concerning Standby Liquid Control Sys & Standby Svc Water Flow Problems.Initially Reported on 830127 & 0721.Sys Will Be Modified Per Separation Criteria.Next Rept by 831101 | Safe Shutdown |
GO2-83-795, Interim Deficiency Rept,Condition 277 Re Dc Motor Starting Resistors.Initially Reported on 830805.Ohmic Rating of in-place Resistor Setting Via Field Measurements to Be Determined.Next Rept Will Be Provided by 831025 | 2 September 1983 | Interim Deficiency Rept,Condition 277 Re Dc Motor Starting Resistors.Initially Reported on 830805.Ohmic Rating of in-place Resistor Setting Via Field Measurements to Be Determined.Next Rept Will Be Provided by 831025 | |
GO2-83-815, Final Deficiency Rept 251 Re Limitorque Motor Operators W/ Motors from Baldor Electric Co Unqualified Per IEEE 382-1972.Initially Reported on 830422.Limitorque Will Replace Motors W/Units That Meet NUREG-0588 Requirements | 8 September 1983 | Final Deficiency Rept 251 Re Limitorque Motor Operators W/ Motors from Baldor Electric Co Unqualified Per IEEE 382-1972.Initially Reported on 830422.Limitorque Will Replace Motors W/Units That Meet NUREG-0588 Requirements | |
GO2-83-820, Final Deficiency Rept,Item 269 Re Bechtel Power Corp Repair of Wrong Weld Area.Initially Reported on 830705.Remaining Two Welds Qualified Per Class Ii,Ansi B31.1.Two Welds Successfully Repaired & Reradiographed | 9 September 1983 | Final Deficiency Rept,Item 269 Re Bechtel Power Corp Repair of Wrong Weld Area.Initially Reported on 830705.Remaining Two Welds Qualified Per Class Ii,Ansi B31.1.Two Welds Successfully Repaired & Reradiographed | Liquid penetrant |