 Issue dateTitleTopic
ML18114A69414 June 1979Failure of Solenoid Operated Valves to Meet IE Bulletin 79-01 Environ Qualification Requirements.Environmentally Unqualified Valves Have Been or Will Be Replaced
ML18139A87319 November 1980Part 21 Rept Re S&W Notification That out-of-phase Transfer Might Occur When Emergency Buses Are Transferred from Offsite Power Source to Emergency Diesel Generators After Reaching Rated Speed & Voltage.Originally Reported 801114
ML18153A14310 June 1997Part 21 Rept Re Possible Machining Defect in Certain Stainless Steel Swagelok Tube Fitting Bodies.Facilities Have Been Notified About Possible Problem
ML18153B0602 September 1994Initial Part 21 Rept Re Steam Drive AFW Pump Governor Valve Mfg by Dresser-Rand.Maint Procedure to Stroke Governor Valve Stem Performed Weekly & Monitoring of Corrosion Build Up in Gland Seal Leakoff Area Performed Weekly
ML18153B08426 September 1994Suppl to 940902 Initial Part 21 Rept Re Defect W/Governor Valves Used in turbine-driven Pumps Mfg by Dresser-Rand to Formally Addresss Written 30 Day Rept Requirement of 10CFR21(c)(3)(ii)
ML18153C1012 February 1990Part 21 Rept Re Two of Three Pc Cards in GE Type SLV11A1 Over/Undervoltage Relays Failing to Produce Output.Short Between Leads Would Result in Damage to Component 1C5. Sketch of Threshold Detection Board Encl
ML18153D0813 August 1992Interim Part 21 Rept Re Analysis of Klockner-Moeller Model NZM6-63,480 Volt Circuit Breakers.Initially Reported on 920701.Lever Fracture Should Be Examined to Determine If Any Cleaning Sprays or Purifying Agents Have Been Used
ML19208B23031 August 1979Deficiency Rept:On 790828,review Indicated Feeder Breaker Trip Curves to Some Penetrations Not Coordinated W/Penetration Limits.Settings for Proper Penetration Protection Limits Are Being Revised
ML19208B26229 August 1979Deficiency Rept:Radiographic Tests Detected Foreign Matls on Feedwater Sys,Line 16 Inches WFPD-424-601-Q2 & 02,welds FW-18,FW-5A,SW-27 & SW-28.Foreign Matl Removed & No Further Rejectable Indications Detected
ML19208C44114 September 1979Deficiency Rept Re Emergency Diesel Generator Fan Cooling Sys Which Appears to Be Inadequately Designed.Alternatives Presented at 790911-12 Meeting of S&W,Vepco & Colt Industries Currently Being Evaluated to Determine Solution
ML19209B7204 October 1979Interim Deficiency Rept Re Overpressurization of Containment from Main Steam Line Break Inside Containment. Util Evaluating Mods to Limit Auxiliary Feedwater Flow to Affected Steam Generator
ML19209C44825 September 1979Deficiency Rept:On 790920,oil Leakage from Motor Housing Revealed Defect in Casting for Lower Reservoir of Shaft End Bearing on Motor 3AF-P2A.Insp of Three Similar Motors Shows Possible Defect in Unit 4 Motors.Onsite Insp Scheduled
ML19209C8973 October 1979Final Deficiency Rept Re Crack in Valve Disc of Valve MOV-2380.Replacement Disc Will Be Installed
ML19209D09827 September 1979Interim Deficiency Rept Re Inadequate Range of Fault Current Protection on Some Containment Electrical Power Penetrations.Final Rept Will Be Submitted When Work on Circuit Mods Complete
ML19209D18510 October 1979Interim 30-day Deficiency Rept Re Emergency Diesel Generator Fan Cooling Sys.Final Rept Will Be Submitted When Manufacturer Design Mod Implemented
ML19210D11126 October 1979Potential Significant Deficiency Re Exposed Area in Control Cable.Partially Exposed Wire Discovered in Area of Insulation Splice in Control Cable Bundle.Faulty Splice Removed
ML19210D11929 October 1979Interim Deficiency Rept Re Defect in One Conductor of 12- Conductor,Number 14,Class IE Cable.Vendor Informed & Will Inspect Two Reels of Cable Sent to Util.Addl Info Forthcoming in 30-day Rept
ML19210D6929 November 1979Deficiency Rept Re Pipe Stress Analysis for safety-related Sys Showing Nonconservative Pipe Stresses.S&W Will Reanalyze All Isometric Pipe Drawings Affected & Mods Will Be Made as Required
ML19210E33329 November 1979Supplements 780818 Final Deficiency Rept Re Pump Suction & Unstable Flow.Pump Suction Mods Acceptable
ML19210E39230 November 1979Interim Deficiency Rept on Safeguards Area Exhaust Sys. Evaluation Revealed Only Safeguards & Central Area Exhaust Sys Must Be Operational After Seismic Event.Final Rept Forthcoming
ML19210F03821 November 1979Interim Deficiency Rept Re Containment Depressurization Actuation & Safety Injection Actuation Circuitry.Safety Circuits Being Redesigned to Comply W/Fsar Commitments
ML19211B72814 September 1979Suppl to 790910 Deficiency Rept Re Design Inadequacy in Emergency Diesel Generator Fan Cooling Sys.Ambient Temp Ranges Exceed Capability of Fan Cooling Sys.Alternate Solutions Under Evaluation
ML19211C79214 December 1979Final Deficiency Rept Re Containment Depressurization Actuation & Safety Injection Actuation Circuitry.Pump Circuits Modified for Pumps to Continue Through Timing Sequence Until Reset or Lock.Pumps Restart Automatically
ML19224C2717 May 1979Notification of Failure to Meet Environ Qualification for IE-class Equipment Stipulated in IE Bulletin 79-01
ML19249D82718 September 1979Final Deficiency Rept Re Ultrasonic Examination of Ions Indications Found on Weld SW-27 on 16-inch WFPD-424-601-q2. No Rejectable Indications Found & No Repair Work Required
ML19249E79927 September 1979Updates 790828 Rept Re Inadequate Range of Fault Current Protection on Some Containment Electrical Power Penetrations.Review of All Related Power Circuits Completed, W/Appropriate Mods Determined.Mods in Progress
ML19250A48219 October 1979Interim Rept Re Auxiliary Feedwater Pump Motor Casting Defect.Vendor Informed Util That Castings Will Be Completely Evaluated & Problem Corrected to Meet Category I Sys Use Requirements
ML19250B82824 October 1979Final Deficiency Rept Re Interaction Between nonsafety- & safety-grade Equipment.Provides Info on Control Sys,Re Specific Concerns of IE Info Notice 79-22.No Significant Safety Concern Exists
ML19250C45319 November 1979Final Deficiency Rept:On 791114,during Testing of Logic Circuitry in Solid State Protection sys,P-4 Input Not Tested.Verification of P-4 Will Be Incorporated Into Test Procedures for Solid State Protection Sys
ML19253B36510 October 1979Interim Deficiency Rept Re Emergency Diesel Generator Fan Cooling Sys.During Review of Equipment Specs Ambient Temp Ranges Found Exceeding Original Design Limits.Manufacturer Engineered Mod Allowing Operation W/O Overloading Fan
ML19254F24517 October 1979Final Deficiency Rept Re Emergency Diesel Generator 2H Cylinder Exhaust Temps Which Exceeded Max Temp of 1,100 F During 24-h Test.Caused by Insulation Matl in Air Intake Sys.Matl Removed & Units Tested Satisfactorily
ML19254F2637 September 1979Interim Deficiency Rept Re Overpressurization of Containment from Main Steam Line Break.Util,B&W & S&W Investigating Mods to Auxiliary Feedwater Sys to Limit Flow to Broken Steam Generator in Event of Main Steam Line Break
ML19256F6414 December 1979Interim Deficiency Rept Re Seismic Response Spectrum Curves in Pipe Stress Analyses.Three Inconsistencies Discovered in Amplified Response Spectrum Curves Used as Input Data to Pipe Stress Analyses.Analyses Rerun Using Proper Input
ML19256F64228 November 1979Submits Part 21 Rept Re Potential Nonconservative Feature of Westinghouse Large Break LOCA-ECCS Evaluation Model. Defect Could Affect Peak Clad Temp Calculated for LOCA Transient.Analysis Will Be Completed by Early Dec 1979
ML19256G24420 December 1979Interim Deficiency Rept Concerning Significant Breakdown in QC Program Re Verification of Calibr of Forney Compression Testing Machine.Attempting to Calibr Forney Compression Testing Machine in Range of 0 to 25,000 Lbs
ML19257A29411 December 1979Provides Addl Info Re Deficiency Discovered on 791207 Concerning Potential Nonconservative Feature of Large Break LOCA-ECCS Evaluation Model.Reanalysis Performed Using Heatup Rate Dependent Rod Burst Calculation Procedure
ML19257A30811 December 1979Submits Deficiency Rept Re Nonconservatism Found in Error Analysis Assumptions Used to Determine Accuracy of Nuclear Instrumentation Reactor Rate Trip Circuitry.Solution Minimizes Power Overshoot for Rod Drop EventsRod Drop Event
ML19257A31612 December 1979Submits Addl Info Re 791207 Rept of Nonconservative Calculation of Seismic Response Spectra.Analysis of Switchover to New Computer Code Revealed Error Calculating Inertial Forces.Caused by B&W Error.Mod Underway
ML19257A31711 December 1979Submits Info Re Deficiency Found on 791207 Re Nonconservatism in Method Used to Generate Power Distributions & Rod Worths for Dropped Rod Events.New Analysis Performed Using More Conservative ModelRod Drop Event
ML19257D80418 January 1980Final Deficiency Rept Re Failure to Seismically Qualify Differential Pressure Switches on Svc Water Strainers to Control Room Air Conditioners.Switches W/Previous Qualification Will Be Installed Prior to Fuel Loading
ML19257D85817 January 1980Final Rept Re 791218 Significant Breakdown in Forney Compression Testing Machine Calibr Verification.Engineering Investigation Revealed That Compression Test Results Were Conservative.Astm Code Being Reviewed to Assure Compliance
ML19260B1937 December 1979Interim Deficiency Rept Re Certain Seismic Amplified Response Spectrum Curves Used as Input Data to Pipe Stress Analyses.Corrective Action in Progress Using Proper Input Data.Two Pipes Required Mods
ML19260C10414 December 1979Final Deficiency Rept Re Containment Depressurization Actuation & Safety Injection Actuation Circuitry.Indicates Resolution of Revisions to Previously Reported Circuits Not Complying W/Fsar
ML19260C7094 January 1980Final Deficiency Rept Re LOCA-ECCS Evaluation Model
ML19270J77118 January 1980Final Deficiency Rept:On 791220,NRC Region 2 Notified That Differential Pressure Switches on Svc Water Strainers to Control Room Air Conditioning Chillers Were Not Seismically Qualified.Seismically Qualified Switches Ordered
ML19270J77317 January 1980Final Deficiency Rept Re Significant QC Program Breakdown Re Forney Compression Testing Machine Calibr Verification. Machine Has Not Been Calibr in 0-25,000 Lb Range.Compression Testing Machine w/6,000-60,000 Lb Range to Be Installed
ML19273C1992 November 1979Part 21 Rept Re Safeguards Area Exhaust Sys.Info Not Currently Available Will Be Submitted as 30-day Rept
ML19275A86828 September 1979Interim Deficiency Rept Re Performance of nonsafety-grade Equipment in Adverse Environ,Impacting Protective Functions Performed by safety-grade Equipment.Sys Under Review
ML19275B6494 January 1980Interim Deficiency Rept Re DNBR Limit & Nuclear Instrumentation Reactor Rate Trip Circuit,Reported Previously in Separate Submittals.Administrative Reduction in Control Rod Insertion Limits Implemented
ML19276H66514 December 1979Final Deficiency Rept Re Ambient Temp Ranges Exceeding Design Limits for Emergency Diesel Generator Fan Cooling Sys.Mods to Current Fan Drive Shaft & Seasonal Fluid Changes Corrected Deficiency