North Anna Pcwer Station. Unit 1 Occket No. 50-338 IE Bulletin 79-01; 24 Hour Notification of Failure to Meet Environinental QuaTification for IE Class Equigaent On Ksy 7,1979 the station was info r..d that six solenoid valves und in the sa.rple systen do not reet t.he envircreental requirenents as set forth in IE Bulletin 79-01. The specific saaple valves and their function are as follows:
TV-SS-100A Pressurizer Liquid Sample T V-SE-101 A Pressurizer Vapor Saxple TV-SS-102A RCS Cold Leg Sax.ple TV-SS-104A Pressurizer Relief Tank Saxple TV-SS-lC6A RCS Hot Leg Sarple TV-SS-ll2A Steam Generator Surface Sazple These valves are ccntairc.ent isolation valves required during a CDA.
Tne mechanism causing the problen is a plastic plug which could bicck an air port in the solenoid actuator preventing proper operaticn.
The solenoids in questico are manufactured by ASCO.
(Hodel No. 8320A102)
These valves are norrally left in the closed position and are opened only when a sorple is required.
In addition, the valve is designed to fail in the closed pos.ition, therefore the isolaticn capabii t'y of these valves will not he affected by such a failure.
For tnis reason, station operaticos will centinu.