ML120480104

From kanterella
Revision as of 05:46, 30 April 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
Initial Exam 2011-302 Other Documents for Retention
ML120480104
Person / Time
Site: Robinson Duke Energy icon.png
Issue date: 02/10/2012
From:
NRC/RGN-II
To:
Mark Bates
Shared Package
ML120470109 List:
References
Download: ML120480104 (217)


Text

ILC-11-2 NRC Exam

1. 007 EG2.4.11 001Given the following plant conditions: - The unit has just experienced an automatic reactor trip from 100% RTP. - The turbine failed to trip automatically. - A manual turbine trip was initiated and the following indications are present: - Left Turbine Stop Valve indicates CLOSED - All Governor Valves indicate OPEN - RCS pressure is 1860 psig

- T avg is 542°F - No SI equipment has actuated S/G Pressure Steam Flows A 895 psig 0.1 X 10 6 lbm/hr B 915 psig 0.1 X 10 6 lbm/hr C 835 psig 1.45 X 10 6 lbm/hrWhich ONE (1) of the following identifies the required operator response IAW PATH-1?Runback the turbine until....ALL Governor Valves indicate CLOSED AND verify TWO (2) charging pumpsrunningat least the Right Upper and Right Lower Governor Valves indicate CLOSED (allGovernor Valves not required to indicate closed) AND verify TWO (2) chargingpumps running ALL Governor Valves indicate CLOSED AND manually initiate SI at least the Right Upper and Right Lower Governor Valves indicate CLOSED (allGovernor Valves not required to indicate closed) AND manually initiate SI A.B.C.D.

1

ILC-11-2 NRC ExamThe correct answer is A.

A. Correct - During PATH-1 immediate actions if the turbine is not tripped then theturbine is runback until all the governor valves are closed. SI is not required since thecoincidense for high steam line D/P and High Steam Flow have not been met.B. Incorrect. PATH-1 requires that either both turbine stop valves OR ALL governorvalves be closed to consider the turbine tripped. In this distractor the left stop valvewould be closed and the right set of governor valves. This would meet the coincidencefor a generator lockout, but not for declaring the turbine tripped. The second part of the distractor is correct.C. Incorrect - The first part of the distractor is correct. SI is not required since thecoincidense for high steam line D/P and High Steam Flow have not been met. D. Incorrect - PATH-1 requires that either both turbine stop valves OR ALL governorvalves be closed to consider the turbine tripped. In this distractor the left stop valvewould be closed and the right set of governor valves. This would meet the coincidencefor a generator lockout, but not for declaring the turbine tripped. The second part of thedistractor is incorrect since no SI setpoint has been exceeded. The high steam flowwith low Tave coincidence is not met since only one S/G has excessive steam flow. Also, the high steam line D/P is not met.

Question 1Tier/Group 1/1 K/A Importance Rating - RO 4.0 SRO 4.2Reactor Trip: Knowledge of abnormal condition procedures.Reference(s) - Sim/Plant design, PATH-1, PATH-1 bases, ESFAS LogicsProposed References to be provided to applicants during examination - NoneLearning Objective - PATH-1-003Question Source - BANK (Not used in an NRC Exam from 2004 to present.)Question Cognitive Level - H 10 CFR Part 55 Content - 41.10 / 43.5 / 45.13 Comments - MAB Comments:

Is it operationally valid to provide a reactor trip in the stem withoutproviding the power level at the time of trip? This seems a bit artificial, like you arewithholding obvious information just to try to make the question work.

Added initialpower level."Not tripped" does not appear to be plausible. When all turbine stop valves are closed,then the turbine is effectively tripped, regardless of what the basis document states Revised answers to remove "Not tripped". Changed answers to focus onrequirements to runback the turbine to meet the requirements of PATH-1.Added "IAW PATH-1" to stem due to validation comments.

2

ILC-11-2 NRC Exam

2. 008 AK2.03 001Given the following plant conditions: - The plant is at 100% RTP. - PC-444J, PZR PRESS, has failed

HIGH.Assuming NO operator actions are taken, which ONE (1) of the following completes thefollowing statement?The FIRST reactor trip signal will be generated when the reactor protection (1) setpoint is exceeded.PCV-455C, PZR PORV, will receive a closed signal once pressurizer pressure lowersbelow (2) psig.(1) OTdeltaT(2) 2000(1) Low Pressurizer Pressure (2) 2000 (1) OTdeltaT(2) 2185(1) Low Pressurizer Pressure(2) 2185 A.B.C.D.

3

ILC-11-2 NRC ExamThe correct answer is A.

A. Correct.B. Incorrect - At 100% RTP the failed open PORV will have a large impact on theOTdeltaT setpoint. It has been proven on numerous scenarios on the simulator thatthe reactor will trip on OTdeltaT vice Low Pressurizer Pressure at high power levels. Atlow power levels the Low Pressurizer Pressure setpoint will typically be the cause of thereactor trip. The second part of the distractor is correct.C. Incorrect - The first part of distractor is correct. The second part is incorrect. Thepressurizer pressure protection channels will provide an input to close PCV-455C once pressure has lowered below 2000 psig. 2185 psig is the low pressurizer pressurealarm setpoint.D. Incorrect - At 100% RTP the failed open PORV will have a large impact on theOTdeltaT setpoint. It has been proven on numerous scenarios on the simulator thatthe reactor will trip on OTdeltaT vice Low Pressurizer Pressure at high power levels. Atlow power levels the Low Pressurizer Pressure setpoint will typically be the cause of thereactor trip. The second part is incorrect. The pressurizer pressure protection channelswill provide an input to close PCV-455C once pressure has lowered below 2000 psig. 2185 psig is the low pressurizer pressure alarm setpoint.

4

ILC-11-2 NRC Exam Question 2Tier/Group 1/1 K/A Importance Rating - RO 2.5 SRO 2.4Knowledge of the interrelations between the Pressurizer Vapor Space Accident and thefollowing: Controllers and positionersReference(s) - Sim/Plant design, System Description, RPS / ESFAS LogicsProposed References to be provided to applicants during examination - NoneLearning Objective - AOP-019-004Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.6 / 45.4 Comments - MAB Comments:

What other meaningful pressure values can be used other than1715? Your chosen value seems so low that it becomes not plausible. It does notmake sense that the PORV would be allowed to remain open until well after yourreactor trip setpoint of 1844 psig and at the point of SI. This question will besatisfactory if you can address this plausibility concern with two of the distractors. Thisquestion will be considered an E due to the fix being relatively easy, althoughtechnically two answer choices are affected. 2185 psig may be a better choice toconsider - at least it is prior to a reactor trip and SI.Changed 1715 psig to 2185 psig.

5

ILC-11-2 NRC Exam

3. 009 EK2.03 001Given the following plant conditions: - A LOCA has occurred. - RCS pressure is 1100 psig and lowering. - Containment pressure had peaked at 12 psig. - The crew is performing actions of EPP-8, Post LOCA Cooldown and Depressurization.Which ONE (1) of the following identifies the method that will be used to initiatecooldown of the RCS?Initiate cooldown using the...steam dumps at the maximum achievable rate. steam dumps at no greater than 100°F per hour. S/G PORVs at the maximum achievable rate.S/G PORVs at no greater than 100°F per hour.

A.B.C.D.The correct answer is D.A. Incorrect - Steam dumps are not available due to the MSIVs receiving a main steamline isolation signal at 10 psig CV pressure. Several EOPs procedures direct theoperator to cooldown at maximum achievable rate.B. Incorrect - Steam dumps are not available due to the MSIVs receiving a main steamline isolation signal at 10 psig CV pressure. Steam dumps are the preferred means ofcooling down, if available. The cooldown rate is correct.C. Incorrect. The first part of distractor is correct. Several EOPs procedures direct theoperator to cooldown at maximum achievable rate. A 100° F/hr limit is utilized topreclude violation of the Integrity Status Tree thermal shock limits.D. Correct.

6

ILC-11-2 NRC Exam Question 3Tier/Group 1/1 K/A Importance Rating - RO 3.0 SRO 3.3Knowledge of the interrelations between the small break LOCA and the following: S/GsReference(s) - Sim/Plant design, EPP-8, ESFAS Logics, EOP NetworkProposed References to be provided to applicants during examination - NoneLearning Objective - EPP-8-004Question Source - BANK (Used on 2007 NRC Exam.)Question Cognitive Level - H 10 CFR Part 55 Content - 41.7 / 45.7 Comments -

7

ILC-11-2 NRC Exam

4. 011 EK 2.02 001Given the following plant conditions: - A Large Break LOCA has occurred from 100% RTP. - Containment pressure is 23 psig and rising. - PATH-1 is being implemented.

- The CRS has directed the RO to trip the RCPs.Which ONE (1) of the following is the basis for tripping the RCPs?Allowing the RCPs to run would hinder Accumulator injection due to turbulenttwo-phase flow characteristics in loops.Tripping the RCPs will protect them from overheating due to loss of cooling water.Allowing the RCPs to run would force more water out of the break and cause coreuncovery sooner.Tripping the RCPs allows the loop seal to clear thus minimizing RCS inventory loss.

A.B.C.D.The correct answer is B.A. Inorrect - The accumulators will inject during a large break LOCA in an effort torecover and cool the core. Forced flow will not impact the ability of the accumulators toinject their fluid due to the expected differential pressure. B. Correct - During a LBLOCA a phase B signal will be received. This will isolate CCWcooling to the RCPs. The RCPs are therefore secured due to the loss of cooling water.C. Incorrect - This is the basis for stopping RCPs during a SBLOCA. During aSBLOCA the RCPs will be secured once SI flow is verified as being capable of injectingand Subcooling below the threshold of 35°F.D. Incorrect - Depending on break location, once the loop seal has been cleared thenthe break flow could become steam and lower the break flow. This is not associatedwith the requirement to trip the RCPS.

8

ILC-11-2 NRC Exam Question 4Tier/Group 1/1 K/A Importance Rating - RO 2.6 SRO 2.7Knowledge of the interrelations between the following and a Large Break LOCA:Pumps: Reference(s) - Sim/Plant design, PATH-1 Basis DocumentProposed References to be provided to applicants during examination - NoneLearning Objective - PATH-1Question Source - NEW Question Cognitive Level - F 10 CFR Part 55 Content - 41.7 / 45.7 Comments - MAB Comments:

This question will not be counted toward the number of unsatquestions. The KA requires testing Large Break LOCA knowledge. I am not sure hownatural circulation cooling and reflux boiling impact a LBLOCA. The question waswritten for a very small LOCA - a break size for which NC cooling / reflux boiling actually makes sense. I think a new KA is required. We can discuss further ifnecessary, otherwise you will need to write a question to the replacement KA.NEW KA: 011EK2.02 (IR=2.6)

9

ILC-11-2 NRC Exam

5. 015 AK2.08 001Given the following plant conditions:

At time 1852 - The plant experienced a reactor trip from 100% RTP. - 480V Bus E-2 de-energized and operators manually energized the bus from its associated EDG.

At time 1918 - PCV-1716, Instrument Air Isolation to CV, failed closed and Air Operated Valves inContainment are repositioning to their fail position.Which ONE (1) of the following completes the statement below?At time 1933, RCP motor bearing temperatures will (1) and RCP seal leakofftemperatures will (2) the associated alarm setpoint.(1) rise(2) rise above(1) rise(2) remain below(1) remain approximately constant(2) rise above(1) remain approximately constant (2) remain below A.B.C.D.

10

ILC-11-2 NRC ExamThe correct answer is D.A. Incorrect - In this situation, CVC-310A will fail open due to the loss of IA tocontainment. This will cause an initial increase in the charging flow through thecharging path and a momentary lowering of the seal injection flow. The reduction inseal injection flow will cause the seal leakoff temperatures to rise approximately 1°F and then eventually lower back to the original value. A momentary loss of E-2 will cause a momentary loss of the ability to run "C" CCW pump. However, "A" and "B"CCW pumps are available and CCW flow to the RCPs will not be impacted. The motorbearing temperatures will remain relatively constant. To make this selection thecandidate would have to assume that CCW was impacted by the events described.B. Incorrect - See discussion in "A" above. To make this selection the candidate wouldhave to assume that CCW was impacted and seal injection flow remained the same. The candidate must demonstrate knowledge of air operated valve fail positions andtheir impact on plant operations. The second half of distractor is correct. C. Incorrect - The first part of distractor is correct. In this situation, CVC-310A will failopen due to the loss of IA to containment. This will cause an initial increase in the charging flow through the charging path and a momentary lowering of the seal injectionflow. The reduction in seal injection flow will cause the seal leakoff temperatures to riseapproximately 1°F and then eventually lower back to the original value. With twocharging pumps running the PZR level will remain in its normal band. RCP Seal Leakoff temperatures are usually between 115°F and 130°F and will only rise amaximum of one degree before beginning to lower. The alarm setpoint for the RCP Seal Leakoff is 170°F.D. Correct

11

ILC-11-2 NRC Exam Question 5Tier/Group 1 / 1 K/A Importance Rating - RO 2.6 SRO 2.6Knowledge of the interrelations between the Reactor Coolant Pump Malfunctions (Lossof RC Flow) and the following: CCWSReference(s) - Sim/Plant design, AOP-018, AOP-017, System Description, CVCS P&IDProposed References to be provided to applicants during examination - NoneLearning Objective - AOP-014-004Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.7 / 45.7Comments -

Approved by MAB. Revised per phone discussion on 10/12/11 to testwhether the seal leakoff temperatures rise or remain the same. Subsequently,further runs were performed on the simulator and determined that seal leakofftemperatures only rise about 1°F and then begin to lower. Never approached theSeal Leakoff High Temperature alarm.

12

ILC-11-2 NRC Exam

6. 022 AA2.03 001Given the following plant conditions: - The plant is operating at 100% RTP. - RCS Makeup System is properly aligned and an Auto makeup is in progress. - The air supply line to FCV-114A, Primary Water Flow Dilute Mode, severed ONE (1) minute ago.Which ONE (1) of the following identifies the failed position of FCV-114A and expectedalarm?FCV-114A will fail (1) and APP-003-D5, BA FLOW DEV, (2) be received.(1) OPEN(2) will(1) OPEN(2) will NOT(1) CLOSED(2) will(1) CLOSED(2) will NOT A.B.C.D.

13

ILC-11-2 NRC ExamThe correct answer is C.A. Incorrect - FCV-114A will fail closed. Candidate may think that the valve will failopen to allow for ability to makeup to the VCT on a failure of the valve. The secondpart of the distractor would be correct since the primary water flow would still exceedyour pre-set flow values and FCV-113B, Blended MU to CHG SUCT, would close. With FCV-113B closed all BA flow would stop and result in a BA FLOW DEV alarm.B. Incorrect. FCV-114A will fail closed. Candidate may think that the valve will fail opento allow for ability to makeup to the VCT on a failure of the valve. The second part ofdistractor is partially correct assuming that FCV-114A failed open. FCV-114A full openwould cause primary water flow to exceed the pre-set flow values. However, the BA FLOW DEV alarm will also be received due to ALL makeup flow being isolated,including BA flow. Candidate may thin that BA flow will not be impacted.C. Correct - FCV-114A will fail closed on a loss of air. This will result in primary waterflow being less than the preset value and will result in a makeup water deviation alarm. This will close FCV-113B which will isolate all makeup flow to the VCT. This will result in a BA FLOW DEV alarm.D. Incorrect - FCV-114A will fail closed on a loss of air. This will result in primary waterflow being less than the preset value and will result in a makeup water deviation alarm. This will close FCV-113B which will isolate all makeup flow to the VCT. This will resultin a BA FLOW DEV alarm. Candidate may focus in on the fact that the failure wasassociated with the primary water flow control valve and not remember that this willresult in all makeup flow being isolated, including BA flow.

14

ILC-11-2 NRC Exam Question 6Tier/Group 1/1 K/A Importance Rating - RO 3.1 SRO 3.6Ability to determine and interpret the following as they apply to the Loss of ReactorCoolant Makeup: Failures of flow control valve or controllerReference(s) - Sim/Plant design, OP-301, AOP-003, APP-003-D5/E5, SystemDescriptionProposed References to be provided to applicants during examination - NoneLearning Objective - AOP-003-004 Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 43.5 / 45.13 Comments - MAB Comments:Question is backward logic, which presents some of the followingconcerns.

Revised the question to give the air line break and then ask for valvefail position and expected alarm(s).How do you know what HAS caused the alarm? Could a different failure cause 113B tofail closed? Would it be more appropriate to test what a possible, or viable, singlefailure could cause the alarms?The second part of "B" and "C" is not needed - it is just extra information. Those two choices should just state that the air line has been completely severed. Delete ",causing the valve to fail CLOSED."

Added to the stem that the air line was severed.How does letdown have any impact on the two stated alarms? These alarms appear tobe only applicable to the makeup. "D" does not appear to be plausible. Discuss withlicensee to enhance understanding of plausibility.

Removed. Reworded question.How would the charging pump suction impact the two stated alarms? Discussplausibility of "A". Also, since the applicant is forced to assume failures, is there afailure or combination of failures that could make "A" potentially correct.

Removed. Reworded the question.Added "ONE (1) minute ago." to last bullet in stem from validation comments.

15

ILC-11-2 NRC Exam

7. 025 AK3.01 001Which ONE (1) of the following identifies the basis for closing FCV-605, RHR HXBypass Valve, and HCV-758, RHR HX Outlet Flow To Cold Legs, prior to starting the standby RHR Pump IAW AOP-020, Loss of RHR (Shutdown Cooling), Section E, Loss of RHR Flow or Temperature Control?Prevent cavitation of the pump.Reduce the pump starting current and prevent pump runout.Prevent water hammer damage to the RHR Heat Exchangers.Control the introduction of cooler water from the stagnant wate r in the suction anddischarge piping of the standby pump.

A.B.C.D.The correct answer is B.A. Incorrect - Several AOPs and other Operations procedures address RHR pumpcavitation as a concern. In this case there was no impact to NPSH, so cavitation is nota concern.B. Correct - AOP-020 basis document states that the valves are closed to limit thestarting current on the pump. OP-201 states that a RHR Pump should not be startedwith FCV-605 in automatic as this could allow runout of the pump before the controlvalve could respond.C. Incorrect - Although some water hammer effects may be felt, this is not the basis forthe decision for closing the stated valves. Additionally, the RHR Heat Exchangers willbe exposed to a pressure transient when starting the standby pump since the statedvalves are downstream of the RHR Heat Exchangers.D. Incorrect - Although some cooler water may be present in the discharge and suctionline of the stagnant pump, this is not the basis for the actions.

16

ILC-11-2 NRC Exam Question 7Tier/Group 1/1 K/A Importance Rating - RO 3.1 SRO 3.4Knowledge of the reasons for the following responses as they apply to the Loss ofResidual Heat Removal System: Shift to alternate flowpathReference(s) - Sim/Plant design, AOP-020BD, OP-201, System Description Proposed References to be provided to applicants during examination - NoneLearning Objective - AOP-020-004Question Source - NEW Question Cognitive Level - F 10 CFR Part 55 Content -

41.5 / 41.10 / 45.6 / 45.13Comments - Discussion with P. Capehart on 6/15/11:

Discussed that RNP does nothave alternate flowpaths or other inter-connected systems. Agreed to prepare aquestion based on losing one operating pump and having to take action to place thestandby train in service.MAB comment: This question appears to be (F)undamental LOK, not (H)igher. Memory item for the reasons for doing the steps. Discuss.

Changed to LOK F.No further comments. Intent of the KA is considered to be met.

17

ILC-11-2 NRC Exam

8. 027 AA1.05 001Given the following plant conditions: - EPP-1, Loss of All AC Power, is being implemented. - The DS Bus has been energized IAW EPP-1, Attachment 6, Restoring AC Power Atthe DSDG Generator Control Panel. - EPP-22, Energizing Plant Equipment Using DSDG, Attachment 1, EnergizingPressurizer Heaters from DS Bus, has been completed and specified heatersenergized. - PC-444J, PZR PRESS, has FAILED to 0% output.Which ONE(1) of the following identifies the alternate method to control pressurizerheaters IAW EPP-22 based on the conditions given above?Operate breakers on Pressurizer Htr Panel #3 Control GroupOperate breaker 52/15B, 480V Bus 3 Main Bkr from the RTGBOperate breaker 52/12B, 480V Bus 2B-3 Tie Bkr from the RTGBOperate the PZR Heater Emergency Control Station in the Rod Control Room A.B.C.D.The correct answer is C.A. Incorrect - This action would control power to the control group heaters, however,this panel is in the Rod Control Room and would not provide desired control to thecontrol board operators. Additionally, this option is not specified in EPP-22.B. Incorrect - Opening this breaker would remove power to 480V Bus 3 and 2B andthus the control group heaters. This is not a desired method due to other loads thatmay have been started on 480V Bus 3 when it was energized by the DSDG.C. Correct. The preferred method is to adjust PC-444J in manual to control the amountof firing to the control group heaters. However, since PC-444J has failed to 0% outputthe heaters will be receiving full firing rate when energized.D. Incorrect - Two PZR Heater Emergency Control Stations are located in the RodControl Room. These control stations are utilized in AOP-004, Control RoomInaccessibility, to control the heaters. The Emergency Control Stations control BackupGroup A and Backup Group B.

18

ILC-11-2 NRC Exam Question 8Tier/Group 1/1 K/A Importance Rating - RO 3.3 SRO 3.2Ability to operate and / or monitor the following as they apply to the PressurizerPressure Control Malfunctions: Transfer of heaters to backup power supplyReference(s) - Sim/Plant design, EPP-22, System DescriptionsProposed References to be provided to applicants during examination - NoneLearning Objective - EPP-22-006Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.7 / 45.5 / 45.6Comments - Discussed with P. Capehart on 6/15/11:

Discussed that RNP does nothave an installed, dedicated backup power supply to pressurizer heaters. Agreed towrite question based on manipulating electric plant lineup to supply alternate power topressurizer heaters in accordance with applicable EOP procedure(s).

19

ILC-11-2 NRC Exam

9. 029 EG2.4.49 001Given the following plant conditions:- An ATWS has occurred.- The crew is performing immediate actions of FRP-S.1, Response to NuclearPower Generation/ATWS.- A manual reactor trip using both RTGB pushbuttons was unsuccessful.- Rods are being inserted in MANUAL.

- IAO and OAO have been dispatched to locally trip the reactor.- The THINK and Manual Turbine Trip Buttons have been depressed.- Main Turbine Governor and Stop Valves indicate open.Which ONE (1) of the following identifies the NEXT required action(s) that must betaken IAW FRP-S.1?Close all MSIVs and MSIV Bypasses.Depress and hold the GV Down and GV Fast pushbuttons.Depress the turbine manual pushbutton and then depress and hold the the GVDown pushbutton ONLY.Depress the turbine manual pushbutton and then depress and hold the GV Downand GV Fast pushbuttons.

A.B.C.D.The correct answer is D.A. Incorrect. A run back of the turbine is to be attempted prior to closing the MSIVs andMSIV bypasses.B. Incorrect. The turbine manual pushbutton must be depressed and released prior toperforming the action given in this distractor. C. Incorrect. These actions will begin to run back the turbine, but not at maximum rateas called for in FRP-S.1. In order to go at the maximum rate, the GV Fast pushbuttonmust be depressed.D. Correct.

20

ILC-11-2 NRC Exam Question 9Tier/Group 1/1 K/A Importance Rating - RO 4.6 SRO 4.4Anticipated Transient Without Scram (ATWS): Ability to perform without reference toprocedures those actions that require immediate operation of system components and controls.Reference(s) - Sim/Plant design, FRP-S.1, PATH-1, OMM-022, Sys. DescriptionProposed References to be provided to applicants during examination - NoneLearning Objective - FRP-S.1-003 Question Source - BANK (Not used on NRC Exam from 2004 to present.)

Question Cognitive Level - F 10 CFR Part 55 Content - 41.10 / 43.2 / 45.6 Comments - MAB Comments:

In the correct answer, why would the applicant push the GV Downand GV Fast buttons if the turbine manual pushbutton was successful? Are theapplicants forced to make an assumption here? NUREG-1021 states that applicantsare not to make assumptions, therefore they could conclude the turbine trip wassuccessful.

Revised wording to state that "The THINK and Manual Turbine TripButtons have been depressed" rather that simply stating that a "manual trip ofturbine was unsuccessful."The question statement asks for the next (singular) required action, yet the correctanswer is a list of several actions. Same comment can be applied to other answerchoices where more than one action is provided.

Revised action to action(s).What immediate actions have already been performed? The stem does not providethis information. This forces the applicant to make assumptions as to where they are inthe procedure. This creates multiple correct answers.

Added additional immediateactions of FRP-S.1 to the stem.The question wording and presentation needs to be tightened to ensure one and onlyone correct answer.

Wording revised.

21

ILC-11-2 NRC Exam

10. 038 EK1.04 001Given the following plant conditions: - The plant was operating at 100% RTP. - The plant has experienced a S/G tube rupture with a Loss of Coolant Accident. - Current RCS level is at the hot leg centerline. - No SI flow exists due to multiple malfunctions.Which ONE (1) of the following identifies how the majority of the heat is removed fromthe core for the given conditions?Boiling in the core produces steam which condenses in....the reactor vessel annular space and re-floods the core.the upper head and re-floods the core via the upper internals.the S/G tubes and flows down the cold leg back to the core.the S/G tubes and flows down the hot leg back to the core.

A.B.C.D.The correct answer is D.A. Incorrect - Steam flows along the top of the hot legs to the steam generator where itcondenses and returns to the core via the bottom of the hot leg piping.B. Incorrect - If the upper head was cool the steam could condense and return to thecore. However, the upper head will remain at a high temperature following a LOCA andminimal condensation will occur in the reactor vessel.C. Incorrect - Steam flows along the top of the hot legs to the steam generator where itcondenses and returns to the core via the bottom of the hot leg piping. It would seemintuitive that the condensation would re-enter the reactor vessel via the normal flowpathwhich is the cold leg, however, based on elevation changes, etc., this is not the case.D. Correct.

22

ILC-11-2 NRC Exam Question 10Tier/Group 1/1 K/A Importance Rating - RO 3.1 SRO 3.3Knowledge of the operational implications of the following concepts as they apply to theSGTR: Reflux boilingReference(s) - Sim/Plant design, PATH-1-BDProposed References to be provided to applicants during examination - NoneLearning Objective - FRP-C.1-003Question Source - BANK (Similar question used on 2007 NRC Exam. Questionmodified significantly.)

Question Cognitive Level - F 10 CFR Part 55 Content - 41.8 / 41.10 / 45.3 Comments - Discussed with P. Capehart on 6/15/11:

Discussed concern with havingtwo K/As selected that addressed reflux boiling. (see T1G1 011EK1.01) Agreed toattempt to write a question on the operational implication of reflux boiling associatedwith a SGTR. K/A may be replaced at a later date if extreme difficulty is experienced indeveloping an acceptable question.MAB Comment: The licensee should produce supporting documentation for flowreturning to the core via the hot leg. The provided documentation only states that reflux boiling will occur, but does not define that reflux boiling is entirely limited to returningflow to the core via the hot leg.

23

ILC-11-2 NRC Exam

11. 054 AA1.04 001Given the following plant conditions: - Plant had been operating at 100% RTP for 285 days prior to a plant trip and safetyinjection ocurring. - The crew is performing actions of FRP-H.1, Response to Loss of Secondary HeatSink. - Plant conditions require that an RCS Bleed and Feed be performed.Which ONE(1) of the following completes the statement below?To ensure adequate RCS Injection flow a MINIMUM of (1) safety injectionpump(s) are/is required to be running AND (2)

PZR PORV(s) will be opened toprovide an adequate RCS Bleed path.(1) one(2) one(1) one(2) two(1) two(2) one(1) two (2) two A.B.C.D.

24

ILC-11-2 NRC ExamThe correct answer is B.

A. Incorrect - The first part of the distractor is correct. Per FRP-H.1 basis document theRCS may not depressurize sufficiently to permit adequate feed of subcooled SI flow toremove core decay heat. If both PORVs cannot be opened, FRP-H.1 will direct theoperator to open the RV head and PZR vents.B. Correct.C. Incorrect - FRP-H.1 will direct the operator to initiate a safety injection signal. Thisshould start both SI pumps. However, FRP-H.1 later has the operator verify that atleast one SI pump is running. Per FRP-H.1 basis document the RCS may notdepressurize sufficiently to permit adequate feed of subcooled SI flow to remove coredecay heat. If both PORVs cannot be opened, FRP-H.1 will direct the operator to open the RV head and PZR vents.D. Incorrect - FRP-H.1 will direct the operator to initiate a safety injection signal. Thisshould start both SI pumps. However, FRP-H.1 later has the operator verify that atleast one SI pump is running. The second part of the distractor is correct.

Question 11Tier/Group 1/1 K/A Importance Rating - RO 4.4 SRO 4.5Ability to operate and / or monitor the following as they apply to the Loss of MainFeedwater (MFW): HPI, under total feedwater loss conditionsReference(s) - Sim/Plant design, FRP-H.1, FRP-H.1BDProposed References to be provided to applicants during examination - NoneLearning Objective - FRP-H.1-004Question Source - NEW Question Cognitive Level - F 10 CFR Part 55 Content - 41.7 / 45.5 / 45.6Comments - Discussion with P. Capehart on 6/15/11:

Confirmed that it would beacceptable to focus on Bleed and Feed conditions / actions for a loss of Heat Sink toaddress "HPI, under total feedwater loss conditions."MAB Comments: The procedure has the operator start at least one SI pump and openboth PORVs. Will opening one PORV provide adequate cooling, which is what thequestion is asking? No supporting documentation is provided to support that twoPORVs are required for adequate cooling. This question will be rated as satisfactory ifsufficient documentation can show one and only one correct answer.Page 56 and 57 of FRP-H.1-BD contains the necessary information.

25

ILC-11-2 NRC Exam

12. 055 EG2.1.31 001Given the following plant conditions: - Reactor power is at 100% RTP. - A Generator Lockout occurs simultaneously with a loss of the Startup Transformer. - Both EDGs fail to start.Which ONE (1) of the following completes the statements below?

For the conditions given above, IAW EPP-1, Loss of All AC Power, steam is verifiedisolated to the Turbine by (1) and (2) are required to be CLOSED to isolateletdown flow.(1) closing the MSIVs AND MSIV Bypasses(2) LCV-460A/B, Letdown Line Stop Valves(1) closing the MSIV s and MSIV Bypasses(2) CVC-204A/B, Letdown Line Isolation Valves(1) verifying BOTH Turbine Stop Valves CLOSED(2) LCV-460A/B, Letdown Line Stop Valves(1) verifying BOTH Turbine Stop Valves CLOSED(2) CVC-204A/B, Letdown Line Isolation Valves A.B.C.D.

26

ILC-11-2 NRC ExamThe correct answer is A.

A. Correct.B. Incorrect - First part of distractor is correct. The MSIVs must be closed. The loss ofthe SUT will cause the EH Control Panel to be de-energized and the operator will beunable to confirm that the Turbine Stop Valves are closed. This will require that theMSIVs be closed. CVC-204A/B will isolate letdown if closed, however, EPP-1 directsthe operator to close LCV-460A/B. If LCV-460A/B cannot be closed the RNO is toclose CVC-200A,B,C.C. Incorrect - The MSIVs must be closed. The loss of the SUT will cause the EHControl Panel to be de-energized and the operator will be unable to confirm that theTurbine Stop Valves are closed. This will require that the MSIVs be closed. The second part of the distractor is correct. D. Incorrect- The MSIVs must be closed. The loss of the SUT will cause the EHControl Panel to be de-energized and the operator will be unable to confirm that theTurbine Stop Valves are closed. This will require that the MSIVs be closed.

CVC-204A/B will isolate letdown if closed, however, EPP-1 directs the operator to closeLCV-460A/B. If LCV-460A/B cannot be closed the RNO is to close CVC-200A,B,C. Question 12 Tier/Group 1 / 1 K/A Importance Rating - RO 4.6 SRO 4.3Loss of Offsite and Onsite Power (Station Blackout): Ability to locate control roomswitches, controls, and indications, and to determine that they correctly reflect thedesired plant lineup.Reference(s) - Sim/Plant design, EPP-1, PATH-1Proposed References to be provided to applicants during examination - NoneLearning Objective - EPP-1-003 Question Source - RNP Bank (Not used on NRC Exam from 2004 to present.)

Question Cognitive Level - F 10 CFR Part 55 Content - 41.10 / 45.12 Comments - K/A match because candidate is given the EH Turbine Control indicationsthat show two governor valves open and one stop valve open after a reactor tripfollowed by a Station Blackout. The candidate must evaluate the indications and determine that the MSIVs and MSIV Bypass Valves must be closed.Reviewed and approved by MAB.

27

ILC-11-2 NRC Exam

13. 056 AK1.03 001Given the following plant conditions: - The reactor has tripped due to a loss of off-site power. - Natural circulation flow is being established. - The Subcooling Monitor indicates the following information: - T/C at B07 558°F - T/C at H04 555°F - T/C at D05 556°F - T/C at R08 554°F - The RTGB indicates the following information: - PI-445: 1800 psig - PI-456: 1785 psig

- PI-457: 1795 psigDetermine the current value of subcooling that will be utilized while in the EOPNetwork.60.8 - 62.5°F62.8 - 64.5°F64.8 - 66.5°F66.8 - 68.5°F A.B.C.D.The correct answer is B.A. Incorrect. For this distractor the candidate utilizes the highest temperature and thelowest pressure without converting to psia. 1785 psia has a Tsat of 619.85°F. Subtracting 558°F from 619.85°F equals 61.85°F of subcooling.B. Correct. The lowest pressure of 1785 psig and the highest temperature of 558°F areto be used to calculate subcooling. 1785 psig equates to 1800 psia, which has a Tsatof 621.02°F. Subtracting 558°F from 621.02°F equals 63.02°F of subcooling.C. Incorrect. The candidate would have to incorrectly utilize the lowest indicatedpressure of 1785 psig without converting to psia and the lowest given temperature of 554°F to calculate S/C. 1785 psia equates to a Tsat of approximately 619.85°F. Subtracting 554°F from 619.85°F equals 65.85°F subcooling.D. Incorrect. The candidate would have to incorrectly utilize the lowest indicatedpressure of 1785 psig and the lowest given temperature of 554°F to calculate S/C. 1785 psig equates to a Tsat of approximately 621.02°F. Subtracting 554°F from621.02°F equals 67.02°F subcooling.

28

ILC-11-2 NRC Exam Question 13Tier/Group 1/1 K/A Importance Rating - RO 3.1 SRO 3.4Knowledge of the operational implications of the following concepts as they apply toLoss of Offsite Power: Definition of subcooling: use of steam tables to determine itReference(s) - Sim/Plant design, Steam Tables, OP-307Proposed References to be provided to applicants during examination - NoneLearning Objective - EPP-1-004Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.8 / 41.10 / 45.3 Comments - MAB Comment:Plausibility needs to be enhanced by using 1785 psig without converting to psia. Forexample, 61.85 F would be the resultant SCM when 1785 psia is used in conjunctionwith 558F.

Revised as recommended.Also, does your temperature display have a mechanism for notifying an operator thatthe T/C reading is not reliable and should not be used (I.E. turns a different color)? Ifso, I would like this to be used along with failing to convert the 1785 psig to psia.

No,the temperature display does not have any mechanism for informing the operatorthat the reading is reliable or not.In summary, make the answer choices similar to the following convention:A. Lowest P and Highest TempB. Lowest P without converting to psia and Highest TempC. Lowest P and Lowest Temp (or preferably a higher invalid T/C temp)

D. Lowest P without converting to psia and Lowest Temp (or preferably a higher invalidT/C temp)Revised as recommended.The plausibility can be fixed with a small effort, therefore this question is rated as an"E".Revised the answer and distractors to change the given bands to account forapplicant to use 14.7 psig vice 15 psig to convert to psia. Comment a result ofvalidation comment.

29

ILC-11-2 NRC Exam

14. 057 AA2.04 001Given the following plant conditions: - The plant is operating at 100% RTP. - A loss of Instrument Bus 2 has occurred.Which ONE (1) of the following completes the statement below?Safeguards Train (1)

Sequencer is currently de-energized and (2)

.(1) "A"(2) bistable Status Panel "A" will be de-energized(1) "B"(2) bistable Status Panel "A" will be de-energized(1) "A"(2) channel 2 bistables on Status Panel "A" will be illuminated with the exception ofCV HI-HI Pressure(1) "B"(2) channel 2 bistables on Status Panel "A" will be illuminated with the exception ofCV HI-HI Pressure A.B.C.D.The correct answer is C.A. Incorrect - First part of distractor is correct. Status Panel "A" is powered from IB-3and will therefore remain energized.B. Incorrect - Safeguard Train "A" is powered from IB-2. Status Panel "A" is poweredfrom IB-3 and will therefore remain energized.C. Correct.D. Incorrect - Safeguard Train "A" is powered from IB-2. The second part of the distractor is correct.

30

ILC-11-2 NRC Exam Question 14Tier/Group 1/1 K/A Importance Rating - RO 3.7 SRO 4.0Ability to determine and interpret the following as they apply to the Loss of Vital ACInstrument Bus: ESF system panel alarm annunciators and channel status indicatorsReference(s) - Sim/Plant design, APP-002-B2, AOP-024, AOP-024BDProposed References to be provided to applicants during examination - NoneLearning Objective - AOP-024-002Question Source - NEW Question Cognitive Level - F 10 CFR Part 55 Content - 43.5 / 45.13 Comments -

31

ILC-11-2 NRC Exam

15. 058 AA1.03 001Given the following plant conditions: - Plant was operating at 100% RTP. - A loss of "A" DC Bus occurs.FIVE (5) minutes later, which ONE (1) of the following identifies the expected plantresponse due to the loss of "A" DC Bus? Safety Injection Exciter Field Bkr Actuation Auto Trips YES YES YES NO NO YES NO NO A.B.C.D.The correct answer is B.A: Incorrect - The first distractors is correct. The Exciter Field Bkr will not open due to a lossof control power. Foldout "A" contains steps to dispatch personnel to open theexciter field breaker on a loss of "A" DC bus. The Exciter Field Bkr will trip on aloss of "B" DC Bus. B: Correct C: Incorrect - Candidate may not remember that Instrument Bus 1 is lost due to the loss of E-1resulting in the SI. Candidate may also think that there is not relationshipbetween a loss of DC power with the Exciter Field breaker since a GeneratorLockout will still occur from the 86BU.D: Incorrect - See discussion in "C" above for SI Actuation. The second part of distractor iscorrect.

32

ILC-11-2 NRC Exam Question 15Tier/Group 1/1 K/A Importance Rating - RO 3.1 SRO 3.3Ability to operate and / or monitor the following as they apply to the Loss of DC Power:Vital and battery bus componentsReference(s) - Sim/Plant design, EPP-26/27, EPP-26/27BDProposed References to be provided to applicants during examination - NoneLearning Objective - EPP-26-008Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.7 / 45.5 / 45.6Comments - MAB Comments:

Why are so many columns used? Generally good question writingpractice would suggest that only the info needed to make 4 unique answer choicesshould be used. With that stated, can the answer choices be limited to only the firstand last column (SI Actuation and Exciter Field Breaker)? The extra information typically just weakens the plausibility of the distractors by providing additional ways todisqualify those distractors.

Deleted the PCV-1922 and 4KV Buses 1 & 2 columns.Added "FIVE (5) minutes later," to the stem of the question to ensure that theturbine coastdown had occurred and a loss of E1 bus. The loss of E1 gives the SI signal. Based on validation comments.

33

ILC-11-2 NRC Exam

16. 065 AA2.05 001Given the following plant conditions: - Plant is at 35% RTP. - APP-002-E7,INST AIR COMP D TRIP, illuminates. - APP-002-F7, INST AIR HDR LO PRESS, illuminates. - AOP-017, LOSS OF INSTRUMENT AIR, is entered. - Station Air and Instrument Air have been cross-connected. - Transition has been made to AOP-017, Section A, Modes 1 AND 2. - Instrument Air pressure is 64 psig. - "B" and "C" S/Gs Levels are at 42% and slowly lowering.Which ONE (1) of the following completes the statement below?

The operating crew is required to

while continuing in AOP-017.cross-connect Station Air and Construction Airlower turbine load as necessary to maintain feed and steam flows matchedtrip the turbine and implement AOP-007, Turbine Trip below P-8,trip the reactor and Go to PATH-1 A.B.C.D.The correct answer is D.A. Incorrect - AOP-017 does not direct cross-connecting station air and construction air. Construction air can be cross connection with station air, and it typically done so duringan outage or when a large demand on station air is needed.B. Incorrect - Although lowering turbine load may assist in matching steam flow andfeed flow this is not a mitigation strategy specified in AOP-017. The correct strategy isspecified in AOP-010.C. Incorrect - AOP-017 directs that the reactor be tripped if S/G level is adverslyaffected by loss of IA if in Mode 1 or 2. Candidate may think that only a turbine trip isrequired since power is less than P-8 and a Turbine Trip would not result in a ReactorTrip.D. Correct - Step of AOP-017, Attachment A, asks the operator to check any S/G levelcontrol "Adversely affected by loss of IA." This would be answered "YES." The nextstep would have the operator trip the reactor and go to PATH-1 and continue inAOP-017.

34

ILC-11-2 NRC Exam Question 16Tier/Group 1/1 K/A Importance Rating - RO 3.4 SRO 4.1Ability to determine and interpret the following as they apply to the Loss of InstrumentAir: When to commence plant shutdown if instrument air pre ssure is decreasingReference(s) - Sim/Plant design, PATH-1, AOP-017Proposed References to be provided to applicants during examination - NoneLearning Objective - AOP-017-004Question Source - BANK (Last used for HLC-06 Replacement NRC Exam.)

Question Cognitive Level - F 10 CFR Part 55 Content - 43.5 / 45.13 Comments - MAB Comments:

IA pressure is 83 psig. Therefore, I am having difficultyunderstanding how MFR valves would be affected. Typically MFR valves will control atmost plants at pressures much lower than 83 psig (maybe even down to 50 or 60 psig). Lowered the IA pressure to 64 psig. Add "to" prior to the blank.

Added"C" is not plausible. Everything in the stem points to instrument air as being theproblem (Instrument Air Alarms are annunciating). So if IA is the problem, takingmanual control does not have much credibility.

Replaced "C" with "trip the turbineand implement AOP-007, Turbine Trip below P-8."Reformatted the question to separate the initial conditions and currentconditions.

35

ILC-11-2 NRC Exam

17. W/E 05 EK3.1 001Given the following plant conditions: - A loss of BOTH Main Feedwater Pumps (MFP) has resulted in a manual reactortrip. - All 3 AFW Pumps are disabled. - The crew is performing actions of FRP-H.1, Response to Loss of Secondary Heat Sink. - Wide Range S/G levels are at 25% and lowering.

- Attempts to start either MFP have failed.

- PZR Level was maintained greater than 16%. Which ONE (1) of the following completes the statement below?IAW FRP-H.1, RCS pressure will be reduced by opening (1) to allow the (2)

.(1) one PZR PORV(2) Hi Steam Line DP and PZR Pressure SI signals to be blocked prior toperforming actions to establish Condensate flow(1) CVC-311, Aux. Spray(2) Hi Steam Line DP and PZR Pressure SI signals to be blocked prior toperforming actions to establish Condensate flow(1) one PZR PORV(2) safety injection flow to inject into the RCS(1) CVC-311, Aux. Spray(2) safety injection flow to inject into the RCS A.B.C.D.

36

ILC-11-2 NRC ExamThe correct answer is B.

A. Incorrect. Opening one PZR PORV would be the correct answer if letdown hadisolated. No information was given in the st em to indicate that PZR Level had loweredto the point at which letdown had isolated, so auxiliary spray would be utilized to lowerpressure. The second part of the distractor is correct.B. Incorrect - One PZR PORV would be used to reduce RCS pressure if letdown hadbeen secured based on PZR level. Since letdown was in service then Auxiliary Spraywill be the correct answer. One S/G will have to be depressurized to less than 600 psigto enable a condensate pump to flow forward into the S/G. The SI signals will beblocked to preclude having to reset the FW Isolation signals. Lowering RCS pressurewill allow for more SI injection into the RCS, but this is not the basis for this step.C. Incorrect - One PZR PORV would be used to reduce RCS pressure if letdown hadbeen secured based on PZR level. Since letdown was in service then Auxiliary Spraywill be the correct answer. The second part of the distractor is the basis for depressurizing the RCS when RCS Bleed and Feed is required. In this event Bleedand Feed criteria have not been met since S/G levels are at 25% Wide Range. Thecriteria for initiating Bleed and Feed is at least two S/G Wide Range levels less than10% [19%].D. Incorrect - Since letdown is in service then Auxiliary Spray is the correct method forlowering PZR pressure. The second part of the distractor is the basis fordepressurizing the RCS when RCS Bleed and Feed is required. In this event Bleedand Feed criteria have not been met since S/G levels are at 25% Wide Range. Thecriteria for initiating Bleed and Feed is at least two S/G Wide Range levels less than10% [19%].

37

ILC-11-2 NRC Exam Question 17Tier/Group 1/1 K/A Importance Rating - RO 3.4 SRO 3.8Knowledge of the reasons for the following responses as they apply to the (Loss ofSecondary Heat Sink): Facility operating characteristics during transient conditions, including coolant chemistry and the effects of temperature, pressure, and reactivitychanges and operating limitations and reasons for these operating characteristics.Reference(s) - Sim/Plant design, FRP-H.1, FRP-H.1BDProposed References to be provided to applicants during examination - NoneLearning Objective - FRP-H.1-004 Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content -

41.5 / 41.10 / 45.6 / 45.13Comments - MAB Comments:

In a loss of heat sink scenario, how long would it take to get to 25%wide range SG levels - assuming EOC, long operating run, trip from full power? Afterthis time has elapsed, what would pressurizer level likely be? Is 12% a reasonablepressurizer level for these circumstances? I this situation operationally valid? Depending on how quick the operator isolated the MSRs, it could take 15 to 20minutes for S/G levels to lower ot 25% wide range. Revised the question toremove the PZR level indication. Therefore, with PZR level in normal range Aux.Spray will now be the correct response.

38

ILC-11-2 NRC Exam

18. W/E 12 EK3.3 001Given the following plant conditions:- A Reactor Trip and Safety Injection have occurred from 100% RTP.- Following the Immediate Action Verifications of PATH-1, Breaker 52/2BL, Feed toMCC-9, trips.- EPP-16, Uncontrolled Depressurization of All Steam Generators, is beingperformed.- All steam generator (S/G) pressures are lowering uncontrollably. Which ONE (1) of the following completes the statement below regarding the preferredmethod for controlling feedwater flow in accordance with EPP-16?The basis for lowering flow to 80 to 90 gpm to all S/Gs is to (1) and the preferredmethod of controlling AFW flow is to (2)

.(1) minimize RCS repressurization rate(2) dispatch an operator to manually throttle the V2-16s(1) maintain S/G components in "wet" condition(2) dispatch an operator to manually throttle the V2-16s(1) minimize RCS repressurization rate(2) throttle the MDAFW Flow Controllers FIC-1424 and FIC-1425(1) maintain S/G components in "wet" condition (2) throttle the MDAFW Flow Controllers FIC-1424 and FIC-1425 A.B.C.D.

39

ILC-11-2 NRC ExamThe correct answer is D.

A. Incorrect. With a fault in one or two S/Gs the operators are directed in Foldout A todump steam from the intact S/G to control RCS repressurization once the faulted S/Gshave dried out. Candidate may think that controlling the AFW flow to the S/Gs will have the same desired effect. Dispatching an operator to manually throttle the V2-16s is theRNO method for controlling flow. Typically this method is necessary due to the varyingpressures in the S/G's. However, control of feedwater is preferred to remain in thecontrol room.B. Incorrect. The first part of the distractor is correct. Dispatching an operator tomanually throttle the V2-16s is the RNO method for controlling flow. Typically this method is necessary due to the varying pressures in the S/G's. However, control offeedwater is preferred to remain in the control room.C. Incorrect. With a fault in one or two S/Gs the operators are directed in Foldout A todump steam from the intact S/G to control RCS repressurization once the faulted S/Gshave dried out. Candidate may think that controlling the AFW flow to the S/Gs will have the same desired effect. The second part of the distractor is correct. D. Correct.

40

ILC-11-2 NRC Exam Question 18Tier/Group 1/1 K/A Importance Rating - RO 3.5 SRO 3.7Knowledge of the reasons for the following responses as they apply to the(Uncontrolled Depressurization of all Steam Generators): Manipulation of controls required to obtain desired operating results during abnormal, and emergency situations.Reference(s) - Sim/Plant design, EPP-16, EPP-16BDProposed References to be provided to applicants during examination - NoneLearning Objective - EPP-16-003 Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content -

41.5 / 41.10 / 45.6 / 45.13Comments - MAB comments:

Why would locally throttling AFW flow be plausible when nothing inthe stem would cause an applicant to doubt control of AFW from the control room. Some complication needs to be a dded to the stem to make A(2) and B(2) plausible. There may be several ways to accomplish this - like failing a power supply that has noimpact, but would add credibility.Added "Following the Immediate Action Verifications of PATH-1, Breaker 52/2BL,Feed to MCC-9, trips" to the stem of the question. A loss of MCC-9 will affectseveral AFW MOVs, but not the flow control valves. As previously written thisquestion had several misses during the validation. In simulator training veryseldom can the flows be achieved to all S/Gs due to S/G pressure differences. This results in local cycling of the valves being required.

This occurs so oftenthat candidates often think that this is the preferred method of obtaining thedesired flowrates.

41

ILC-11-2 NRC Exam

19. 005 AK2.02 001Given the following plant conditions: - The plant is operating at 50% RTP with OST-011, Rod Cluster Control Exercise &Rod Position Indication, being performed. - When Control Bank "D" rods are returned to 164 steps it is noted that one rod is 17steps below the rest of the bank. - AOP-001, Malfunction of Reactor Control System, is implemented by the crew. - The Shift Manager has directed that the rod be realigned IAW AOP-001.Which ONE (1) of the following completes the basic method used to realign the rod inaccordance with AOP-001 listed below?Open the Control Bank "D" lift coil disconnect switch(es) for (1)

.Realign the rod using (2) position of the rod bank selector switch.Close all lift coil disconnect switches.(1) all but the misaligned rod(2) CB D(1) all but the misaligned rod(2) M (MANUAL)(1) the misaligned rod(2) CB D(1) the misaligned rod (2) M (MANUAL)

A.B.C.D.

42

ILC-11-2 NRC ExamThe correct answer is A.

A. Correct.B. Incorrect - The first part of the answer is correct. AOP-001 specifies that the rodswill be moved by selecting the specific bank on the Rod Bank Selector switch. Sincethis is Control Bank D, leaving the Rod Bank Selector switch in Manual would not be aproblem based on rod sequencing but is not authorized by the procedure.C. Incorrect - The process for recovery is to withdraw the affected rod to align with theother rods in the bank. If only the misaligned rod lift coil disconnect switch was openedthen all the unaffected rods would have to be inserted. This would create a muchlarger and undesired reactivity effect. The second part of the di stractor is correct.D. Incorrect - The process for recovery is to withdraw the affected rod to align with theother rods in the bank. If only the misaligned rod lift coil disconnect switch was openedthen all the unaffected rods would have to be inserted. This would create a muchlarger and undesired reactivity effect. AOP-001 specifies that the rods will be moved byselecting the specific bank on the Rod Bank Selector switch. Since this is Control Bank D, leaving the Rod Bank Selector switch in Manual would not be a problem based onrod sequencing but is not authorized by the procedure.

Question 19Tier/Group 1/2 K/A Importance Rating - RO 2.5 SRO 2.6Knowledge of the interrelations between the Inoperable / Stuck Control Rod and thefollowing: Breakers, relays, disconnects, and control room switchesReference(s) - Sim/Plant design, AOP-001, AOP-001BDProposed References to be provided to applicants during examination - NoneLearning Objective -AOP-001-004Question Source - BANK Question Cognitive Level - H 10 CFR Part 55 Content - 41.7 / 45.7 Comments - MAB Comment:

Add to the question stem, "in accordance with AOP-001."

Added

43

ILC-11-2 NRC Exam

20. 028 AA2.04 001Given the following plant conditions: - Plant is at 100% RTP. - "C" Charging Pump is in Auto and "B" Charging Pump is in Manual. - Pressurizer level transmitter LT-459 is selected for control. - The reference leg for LT-460 develops a leak. Which ONE (1) of the following identifies the instrument and plant response?

LI-460 "C" Charging Pump PZR LVL Speed Controller

Indication

Output Lowers Rises Rises Lowers Lowers Remains the same Rises Rises A.B.C.D.The correct answer is D.A. Incorrect - The reference leg leak will cause LI-460 to fail high. The indication wouldlower if the leak was on the variable line of the D/P cell. Due to the actual leak PZRlevel will lower as seen on LT-459. LT-459 lowering will result in the output of thespeed control to "C" CCP to rise in order to maintain PZR level on the reference level.B. Incorrect - The first part of the distractor is correct. Candidate confuse LT-460 levelrise with a rise in the controlling channel. The candidate could also think that bothLT-460 and LT-459 share a common reference leg. Both errors would result in thecandidate selecting a lowering of the "C" CCP speed controller output.C. Incorrect - The reference leg leak will cause LI-460 to fail high. The indication wouldlower if the leak was on the variable line of the D/P cell. D. Correct - The reference leg leak will cause LI-460 to fail high. The actual leak willresult in an acual reduction of PZR Level as seen on LT-459. This will result in a rise in"C" CCP speed controller output.

44

ILC-11-2 NRC Exam Question 20Tier/Group 1/2 K/A Importance Rating - RO 2.6 SRO 3.1Ability to determine and interpret the following as they apply to the Pressurizer LevelControl Malfunctions: Ammeters and running indicators for CVCS charging pumpsReference(s) - Sim/Plant design, System Description, GFESProposed References to be provided to applicants during examination - NoneLearning Objective - AOP-025-004Question Source - BANK (Modified from a question used on 2007 NRC Exam. Used VCT level in 2007 vice CCP Speed Controller Output.)Question Cognitive Level - H 10 CFR Part 55 Content - 43.5 / 45.13 Comments - Discussion with P. Capehart on 6/15/11:

RNP does not have ammeterindicators for CVCS charging pumps. It was agreed that any indications of CVCScharging pumps (speed indication, red/green lights, Flowrate, etc.) could be utilized tomeet this K/A.MAB Comments:Why are three columns of information provided in the answerchoices? Generally good question writing practice would suggest that only the infoneeded to make 4 unique answer choices should be used. Suggest deleting the lastcolumn because it does not help to distinguish the answer choices. Because of thisknowledge required by the KA is not needed to answer the question. I can answer thequestion with or without that third column just by knowing how the two level indicatorsrespond.

Deleted the first column. Left the last column since this is more relatedto the KA.To try to fix the question, I would suggest breaking the reference leg on the LT that is not selected for control. Test how that LI responds with a broken reference leg andthen test how the "C" charging pump speed controller responds. By doing this, the KAis met and the previous comment would also be addressed.

Revised as requested.

Change the question to have the non-controller channel reference leg break.

45

ILC-11-2 NRC Exam

21. 032 AA2.09 001I&C has just completed a surveillance on the high voltage power supply to SourceRange nuclear instrument N-31. The surveillance determined the as-found voltage was1400 VDC, instead of the normal 1600 VDC.Which ONE (1) of the following identifies the effect the lower voltage has on SR N-31instrument response?N-31 will indicate (1) than normal due to a reduction in voltage to the (2)

.(1) higher(2) pulse height discriminator(1) higher(2) detector(1) lower(2) pulse height discriminator(1) lower (2) detector A.B.C.D.The correct answer is D.A: Incorrect - Pulse height discriminator circuit has no relation to the High Voltageapplied to the detector. B: Incorrect - Indicated power will lower. The reduction of 200 VDC is significant.C: Incorrect - Pulse height discriminator circuit has no relation to the High Voltageapplied to the detector.D: Correct - The high voltage set at 1600 VDC in the Proportional Region of thedetector curve, such that a significant reduction in applied voltage will result in a reduced count rate.

46

ILC-11-2 NRC Exam Question 21Tier/Group 1/2 K/A Importance Rating - RO 2.5 SRO 2.9Ability to determine and interpret the following as they apply to the Loss of SourceRange Nuclear Instrumentation: Effect of improper HV settingReference(s) - Sim/Plant design, LP-703, System Description, GFESProposed References to be provided to applicants during examination - NoneLearning Objective - GFES Sensors and DetectorsQuestion Source - BANK (Last used for HLC-08. Format of question revised.)Question Cognitive Level - H 10 CFR Part 55 Content - 43.5 / 45.13 Comments - MAB Comments:

Suggest deleting the extra words in the answer choices unless theyare necessary to remain. I.E. A(2) pulse height discriminator; B(2) detector. Removedextra words as recommended.Revised question to focus only on N-31 vice both source range instruments. Validation comment.

47

ILC-11-2 NRC Exam

22. 033 AG2.2.44 001Given the following plant conditions: - The plant is at 8% RTP with the Turbine at 1800 RPM, unloaded. - The following is the current status of plant permissives: (lightly shaded blocks are illuminated, darker blocks are extinguished) - An operator assisting I&C with N-35 maintenance removes the N-35 control powerfuses.Which ONE (1) of the following identifies the Reactor Protection System response forthe N-35 IR Level Trip Bypass switch positions shown below?

NORMAL BYPASS No Reactor Trip No Reactor Trip Reactor Trip No Reactor Trip No Reactor Trip Reactor Trip Reactor Trip Reactor Trip A.B.C.D.

48

ILC-11-2 NRC ExamThe correct answer is D.A. Incorrect - Removing the control power fuse will trip the RPS bistable for theassociated IR instrument. Placing the IR Level Trip Switch in Bypass will block an IRtrip signal, but only if the channel has control power. Based on the current power leveland status of the Intermediate Range Trip Blocked status light, the IR High Trip has notbeen blocked.B. Incorrect - Removing the control power fuse will trip the RPS bistable for theassociated IR instrument. Placing the IR Level Trip Switch in Bypass will block an IRtrip signal, but only if the channel has control power. Based on the current power leveland status of the Intermediate Range Trip Blocked status light, the IR High Trip has notbeen blocked.C. Incorrect - Removing the control power fuse will trip the RPS bistable for theassociated IR instrument. Placing the IR Level Trip Switch in Bypass will block an IRtrip signal, but only if the channel has control power. Based on the current power leveland status of the Intermediate Range Trip Blocked status light, the IR High Trip has notbeen blocked.D. Correct.

Question 22Tier/Group 1/2 K/A Importance Rating - RO 4.2 SRO 4.4Loss of Intermediate Range Nuclear Instrumentation: Ability to interpret control roomindications to verify the status and operation of a system, and understand how operatoractions and directives affect plant and system conditions.Reference(s) - Sim/Plant design, System Description, OWP-011 (NI-7)Proposed References to be provided to applicants during examination - NoneLearning Objective - NIS SD-010-010 Question Source - BANK (Not used on an NRC Exam from 2004 to present.)

Question Cognitive Level - H 10 CFR Part 55 Content - 41.5 / 43.5 / 45.12Comments -

49

ILC-11-2 NRC Exam

23. 060 AK1.02 001Given the following plant conditions: - Plant is in Mode 3. - R-14C, Main Vent Stack (Low Range Noble Gas), is inoperable. - A leak on "C" Waste Gas Decay Tank has resulted in an R-20, Fuel HandlingBuilding Lower Level - Low Range, alarm. - IAW AOP-009, Accidental Gas Release From a WGDT, the HP has been directedto obtain air samples of the affected area and local evacuation completed.Which ONE(1) of the following completes the statements below?IAW AOP-009, HVE-5A (1)

HVE-5B are required to be placed in service and (2) due to R-14C being inoperable.(1) AND(2) R-11/R-12 are required to be selected to the VENT Position(1) OR(2) R-11/R-12 are required to be selected to the VENT Position(1) AND(2) verify that R-14D, Main Vent Stack Mid Range, is operable(1) OR (2) verify that R-14D, Main Vent Stack Mid Range, is operable A.B.C.D.The correct answer is B.

A. Incorrect - HVE -5A and HVE-5B cannot be run simultaneously due to interlocks. Candidate may think that it is desired to have both running to provide more filtered flow. The second part of distractor is correct. B. Correct - AOP-009 requires that either HVE-5A OR -5B be placed in service. R-11/R-12 are aligned to the vent to ensure the gaseous release is monitored.

C. Incorrect - HVE -5A and HVE-5B cannot be run simultaneously due to interlocks. Candidate may think that it is desired to have both running to provide more filtered flow. R-14D is the Mid Range Accident monitor part of the R-14 Skid. Candidate may thinkthat is acceptable to use the R-14D since higher reading will be expected with the accidental release in progress.D. Incorrect - The first part of the distractor is correct. R-14D is the Mid Range Accidentmonitor part of the R-14 Skid. Candidate may think that is acceptable to use the R-14Dsince higher reading will be expected with the accidental release in progress.

50

ILC-11-2 NRC Exam Question 23Tier/Group 1/2 K/A Importance Rating - RO 2.5 SRO 3.1Knowledge of the operational implications of the following concepts as they apply toAccidental Gaseous Radwaste Release: Biological effects on humans of the varioustypes of radiation, exposure levels that are acceptable for personnel in a nuclearreactor power plant; the units used for radiation intensity measurements and forradiation exposure levelsReference(s) - Sim/Plant design, HPP-105, DOS-NGGC-0004, 10CFR20Proposed References to be provided to applicants during examination - NoneLearning Objective - MCD-12, PLANT ACCESS TRAINING Question Source - NEW Question Cognitive Level - F10 CFR Part 55 Content - 41.8 / 41.10 / 45.3Comments - Originally the question had the following in the stem.

Airborne radioactivity area if concentrations are such that an individual present in thearea without respiratory protective equipment could exceed, during the hours anindividual is present in a week, an intake of (1) percent of the Annual Limit on Intake.The choices were 1 and 0.6, with 0.6 being the correct answer. All validators choice 1as the answer.MAB Comments:

Why is all the peripheral information provided to start out thequestion? Delete all of the unnecessary information. Window dressing that has nomaterial impact does not help match the KA. The only thing it does is add more for theapplicant to read. In this question you are asking for parts of the definition of a DAC and an ALI. I do not think that only testing knowledge of those two definitions is testingthe operational implications part of the KA.

Noted. Question revised to focus moreon the operational implication of the accidental waste gas release.Suggestion: Any operational implication could be tested. This could include proceduralactions based on exceeding an exposure limit, etc. You do not need to test everyaspect of the list provided in the KA, but you do need to test the operationalimplications.

Tested knowledge of the operation of HVE-5A/B and requirementswith R-14C inoperable coincident with an accidental waste gas release.

51

ILC-11-2 NRC Exam

24. 067 AA1.06 001Given the following plant conditions: - The plant is operating at 100% RTP. - The following fire alarms (color of text) have been received on the Fire AlarmComputer.- A43 ZN-20 Fire Alm. TRN-A E1/E2 Room (RED)- A51 ZN-20 Fire Alm. TRN-A E1/E2 Rm. Halon Actuated (RED)

- A55 ZN-NO Fire Alm. TRN-A FDAP A1 Master Fire Alm. (RED)

- B04 ZN-20 Fire Alm. TRN-B E1/E2 Room (RED)- B06 ZN-20 Fire Alm. TRN-B E1/E2 Rm. Halon Actuated (RED)- B09 ZN-NO Fire Alm. TRN-B FDAP B1 Master Fire Alm. (RED)Which ONE(1) of the following completes the statement below IAW AOP-041,Response to Fire Event?The Control Room Operator is responsible for dispatching the fire brigade, starting themotor driven fire pump, placing the......PCV-456 and PCV-455C Power Isolation Switches to the ISOLATED position andsecuring Auxiliary Building Ventilation. (Control Room Ventilation to remain inNormal Mode.)EDG and E1/E2 Breaker's Appendix R Isolation switches to NORMAL and securingAuxiliary Building Ventilation. (Control Room Ventilation to remain in Normal Mode.)PCV-456 and PCV-455C Power Isolation Switches to the ISOLATED position,securing Auxiliary Building Ventilation and placing Control Room Ventilation in Pressurization Mode.EDG and E1/E2 Breaker's Appendix R Isolation switches to NORMAL, securingAuxiliary Building Ventilation and placing Control Room Ventilation in PressurizationMode.A.B.C.D.

52

ILC-11-2 NRC ExamThe correct answer is A.A. Correct.B. Incorrect - The action to place the Diesel Gen. and E1/E2 Breaker's Appendix RIsolation switches to NORMAL is only applicable in AOP-004 when the control roommust be evacuated. These are recently added switches that maintains normally openswitch contacts to isolate fire-induced cable damage in the event of a postulated fire inthe EDG rooms. Since the fire is in E1/E2 the candidate may think that they should beoperated.C. Incorrect - The first two actions are correct. The action to place control roomventilation in pressurization mode is incorrect. The candidate may think that this is prudent due to the proximity of the fire to the control room. This action is not directed inAOP-041.D. Incorrect. See discussion s in distractors B and C.

Question 24Tier/Group 1/2 K/A Importance Rating - RO 3.5 SRO 3.7Ability to operate and / or monitor the following as they apply to the Plant Fire on Site:Fire alarmReference(s) - Sim/Plant design, AOP-041, APP-44, AOP-004Proposed References to be provided to applicants during examination - NoneLearning Objective - AOP-041-004Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.7 / 45.5 / 45.6Comments - MAB Comments: "C" is not plausible. "A" is a subset of "C"; therefor, if "C" was correct, then "A" wouldalso be correct. A guessing man would always choose the smaller of answers "A" and "C"."D" is not plausible. "B" is a subset of "D".Suggest adding words in parentheses to "A" and "B" stating that placing control room inpressurization mode is not required. This will address the subset issue.

Corrected asrecommended.Question was rated as "E" due to the simplicity of the need ed corrections, even thoughthere were two distractors that were not plausible,

53

ILC-11-2 NRC Exam

25. 076 AK2.01 001Given the following plant conditions: - Plant is currently at 100% RTP preparing for a shutdown due to

high RCS Activitylevels. - A RCS leak of 10 gpm has been identified inside Containment.Which ONE(1) of the following identifies which process radiation monitors will indicatean elevated reading?R-11: Containment Air ParticulateR-12: Containment Air Gas R-14C: Plant Stack Gas (Low range)

R-11 R-12 R-14C Yes Yes Yes Yes Ye s No No Yes Yes Yes No No A.B.C.D.The correct answer is B.A. Incorrect - R-14C is aligned to the stack. The CV is currently being sampled byR-11 and R-12. R-14C would indicate a rise in reading if leakage was into the AuxiliaryBuilding.B. Correct C. Incorrect - The candidate would select this if only the Gas detectors responded tohigh activity RCS leakage and leakage was being released to the Auxiliary Building.D. Incorrect - The candidate would select this if only the CV particulate detectorresponded to high activity RCS leakage.

54

ILC-11-2 NRC Exam Question 25Tier/Group 1/2 K/A Importance Rating - RO 2.6 SRO 3.0Knowledge of the interrelations between the High Reactor Coolant Activity and thefollowing: Process radiation monitorsReference(s) - Sim/Plant design, System Description, AOP-005, OP-920Proposed References to be provided to applicants during examination - NoneLearning Objective - RMS006Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.7 / 45.7 Comments -

55

ILC-11-2 NRC Exam

26. W/E 08 EG2.4.2 001Given the following plant conditions: - Plant was operating at 100% RTP when a steam line break occurs in the CV. - All RCS Cold leg temperatures are right of Pressure - Temperature Limit "A". - RCS pressure is 600 psig.Which ONE(1) of the following completes the statement below?

The CSFST for CSF-4, RCS Integrity, states that entry requirements for FRP-P.1,Response to Imminent Pressurized Thermal Shock, RCS Cold Leg Temperature musthave dropped greater than (1) in the last 60 minutes and RCS Cold LegTemperature must be less than (2)

.(1) 100°F(2) 320°F(1) 100°F(2) 290°F(1) 50°F(2) 320°F(1) 50°F (2) 290°F A.B.C.D.The correct answer is B.A. Incorrect - The first part of the distractor is correct. The second part is the entrycondition value for FRP-P.2.B. Correct.C. Incorrect - 50°F/hr is a common cooldown limit that is used in the EOP network. This rate is used in FRP-P.1 once the one hour soak is completed. The second part isthe entry condition value for FRP-P.2.D. Incorrect- 50°F/hr is a common cooldown limit that is used in the EOP network. Thisrate is used in FRP-P.1 once the one hour soak is completed. The second part of thedistractor is correct.

56

ILC-11-2 NRC Exam Question 26Tier/Group 1/2 K/A Importance Rating - RO 4.5 SRO 4.6Pressurized Thermal Shock: Knowledge of system set points, interlocks and automaticactions associated with EOP entry conditions.Reference(s) - Sim/Plant design, CSFST, FRP-P.1Proposed References to be provided to applicants during examination - NoneLearning Objective - FRP-P.1-003Question Source - NEW Question Cognitive Level - F 10 CFR Part 55 Content - 41.7 / 45.7 / 45.8Comments - MAB Comments:

Currently the question stem asks for what conditions will meet theentry conditions. This causes the two choices with 320F to not be plausible, because if320F meets the criteria, then 290F will obviously also meet the criteria. This can beaddressed by testing specifically what the procedure (Status Tree) states for P.1 entrycriteria. I.E. The CSFST for CSF-4 states that -.

Change "To meet the entry conditions of..." to "The CSFST for CSF-4, RCSIntegrity, states that entry requirements for..." as recommended.

57

ILC-11-2 NRC Exam

27. W/E 10 EK3.1 001Given the following plant conditions: - The reactor has tripped due to a loss of off-site power. - A RCS cooldown to Mode 5 must be performed. - A Natural Circulation cooldown is in progress in accordance with EPP-5, Natural Circulation Cooldown.

- BOTH CRDM Cooling Fans, HVH-5A and 5B, are running.

- TSC has determined that the RCS cooldown rate must exceed the EPP-5 limit.Which ONE (1) of the following completes the statement below?Following procedure transition, the RCS cooldown rate is limited to (1) in order to (2)

.(1) 100°F/hr(2) remain within the Technical Specification limits(1) 50°F/hr(2) remain within the Technical Specification limits(1) 100°F/hr(2) prevent formation of voids in the Reactor Vessel upper head region(1) 50°F/hr (2) prevent formation of voids in the Reactor Vessel upper head region A.B.C.D.

58

ILC-11-2 NRC ExamThe correct answer is A.A. Correct.B. Incorrect - The 50°F/hr cooldown limit is greater than 25°F/hr but the limit in EPP-6and ITS is 100°F/hr. The 50°F/hr cooldown limit is used in other EOP procedures.C. Incorrect - Cooldown rate of 25 oF/hr is allowed in EPP-5 with both HVH-5A and Boperating. When this rate is exceeded, transition to EPP-6 is required. ITS cooldownrate limit of 100 oF/hr is correct. The purpose of EPP-6 is to continue plant cooldownand depressurization to cold shutdown under conditions that allow for the potentialformation of a void in the upper head region.D. Incorrect - Cooldown rate of 25 oF/hr is allowed in EPP-5 with both HVH-5A and Boperating. When this rate is exceeded, transition to EPP-6 is required. The 50°F/hrcooldown limit is used in other EOP procedures. The purpose of EPP-6 is to continueplant cooldown and depressurization to cold shutdown under conditions that allow forthe potential formation of a void in the upper head region.

Question 27Tier/Group 1/2 K/A Importance Rating - RO 3.4 SRO 3.7Knowledge of the reasons for the following responses as they apply to the (NaturalCirculation with Steam Void in Vessel with/without RVLIS): Facility operating characteristics during transient conditions, including coolant chemistry and the effectsof temperature, pressure, and reactivity changes and operating limitations and reasonsfor these operating characteristics.Reference(s) - Sim/Plant design, EPP-5/6, EPP-5/6BDProposed References to be provided to applicants during examination - NoneLearning Objective - EPP-6-004 Question Source - NEW Question Cognitive Level - H10 CFR Part 55 Content -

41.5 / 41.10 / 45.6 / 45.13Comments -

59

ILC-11-2 NRC Exam

28. 003 A1.07 001Given the following plant conditions: - Plant cooldown is in progress IAW GP-007, Plant Shutdown from Hot Shutdown toCold Shutdown. - RCS temperature and pressure is 250°F and 375 psig. - "A" and "C" RCP seal leakoff flows indicate 0.7 gpm. - Seal injection flows are normal.RCS pressure control malfunction occurs and pressure begins to lower. - Maximum RCP Seal Leakoff Temperature is 145°F. - Maximum RCP Pump Bearing Temperature is 132°F.Which ONE (1) of the following completes the statement below?

At (1) the crew is required to (2)

.(1) 325 psig RCS pressure(2) secure RCPs (1) 325 psig RCS pressure(2) open CVC-307, PRI SEAL BYP ISO(1) 210 psid across the RCP #1 Seal(2) secure RCPs(1) 210 psid across the RCP #1 Seal (2) open CVC-307, PRI SEAL BYP ISO A.B.C.D.

60

ILC-11-2 NRC ExamThe correct answer is C.A. Incorrect. 325 psig is the minimum pressure for starting a RCP, however, the RCPcan continue to run as long as 210 psid is maintained on No. 1 Seal. With RCSpressure at 325 psig the No.1 Seal D/P would be approximately 300 psid.B. Incorrect. 325 psig is the minimum pressure for starting a RCP, however, the RCPcan continue to run as long as 210 psid is maintained on No. 1 Seal. With RCSpressure at 325 psig the No.1 Seal D/P would be approximately 300 psid. CVC-307does not have to be opened unless RCP seal leakoff temperatures or RCP PumpBearing temperatures are approaching their alarm setpoints. The given temperaturesare normal for the given plant conditions. This is a recent change to the RCPOperating Procedure.C. Correct. D. Incorrect. CVC-307 does not have to be opened unless RCP seal leakofftemperatures or RCP Pump Bearing temperatures are approaching their alarmsetpoints. The given temperatures are normal for the given plant conditions. This is arecent change to the RCP Operating Procedure.

Question 28Tier/Group 2/1 K/A Importance Rating - RO 3.4 SRO 3.4Ability to predict and/or monitor changes in parameters (to prevent exceeding designlimits) associated with operating the RCPS controls including: RCS temperature and

pressureReference(s) - Sim/Plant design, OP-101, System DescriptionProposed References to be provided to applicants during examination - NoneLearning Objective -RCS 004Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.5 / 45.5 Comments - MAB Comment:

Appendix E of NUREG-1021 directs the applicants to not assumeanything. The question directly contradicts the Appendix E direction by stating that theyare required to assume. Is there a credible pressure control malfunction that results in a linear pressu re decrease?Suggestion: Discard the math and just test the values. This may also allow the stem tobe simplified. Testing the values for when actions need to occur and then testing whatthose actions are will meet the KA.

Removed the math and simply asked for theparameter value necessary to take required action.

61

ILC-11-2 NRC Exam

29. 004 K5.30 001Given the following plant conditions: - The RCS is on RHR and solid. - RCS pressure is 340 psig. - PC-145, PRESSURE, in AUTO. - HIC-142, PURIFICATION FLOW, controller setting is at 55% demand.Subsequently, - HIC-142 controller setting was adjusted to 50% demand.Which ONE (1) of the following completes the statement below?Steady-state to Steady-state, PC-145 controller output will (1) to restore letdownpressure to its original value and overall RCS pressure will (2)

..(1) lower(2) rise(1) rise(2) rise(1) rise(2) lower(1) lower (2) lower A.B.C.D.

62

ILC-11-2 NRC ExamThe correct answer is B.

A Incorrect - PCV-145 is a reverse acting valve. The output on the controller willactually rise to close the valve. The candidate may think that since PCV-145 mustthrotted closed due to closing HIC-142 that the controller output would lower. RCSpressure will rise due to mass flow out lowering while mass flow in has remainedconstant. B Correct.C Incorrect - The first part of the distractor is correct. The candidate may think thatsince letdown flow was lowered that overall system pressure would lower.D Incorrect - PCV-145 is a reverse acting valve. The output on the controller willactually rise to close the valve. The candidate may think that since PCV-145 mustthrotted closed due to closing HIC-142 that the controller output would lower. Thecandidate may think that since letdown flow was lowered that overall system pressurewould lower.

63

ILC-11-2 NRC Exam Question 29 Tier/Group 2/1 K/A Importance Rating - RO 3.8 SRO 4.2Knowledge of the operational implications of the following concepts as they apply to theCVCS: Relationship between temperature and pressure in CVCS components duringsolid plant operationReference(s) - Sim/Plant design, System description, GP-007Proposed References to be provided to applicants during examination - NoneLearning Objective - CVCS 004Question Source - BANK (Last used for the 2004 NRC Exam. Question formatmodified.)

Question Cognitive Level - H 10 CFR Part 55 Content - 41.5 / 45.7 Comments - MAB Comment:

Some supporting information was supplied with the question, but no justification for plausibility was written in the question analysis. The correct answe rmakes perfect sense to me, but I am struggling to see plausibility in the other answerchoices. I placed a question mark on the question rating because no justification wassupplied, so maybe there is something I am missing. Plausibility will need to bediscussed to see if the question is acceptable.Suggestion: Test controller manipulation or controller response. How does theoperator adjust letdown pressure if being controlled in manual and how would theoperator adjust temperature.

Revised the question to have the controller forHIC-142 adjusted from 55% to 50% output and test the knowledge of the impacton PCV-145 and RCS pressure from steady-state to steady-state.Suggestion: How does the plant respond to a failure of valves or controllers for thebypass around the RHR heatexchanger? Then how does the letdown controllerrespond (demand increases or decreases)?

64

ILC-11-2 NRC Exam

30. 004 K6.14 001Given the following plant conditions: - The plant is operating at 100% RTP. - "C" Charging Pump is currently running in AUTO and "B" Charging Pump is runningin MANUAL at minimum speed. - Maintenance has been completed on "A" Charging Pump and WCC has dispatchedan operator to remove the clearance and align the pump for recirculation. - During the valve alignments the operator incorrectly aligns the recirculation path byhaving BOTH CVC-277C, Charging Pump "A" Recirc Root, AND CVC-290,Charging Pump "A" To Charging Line, OPEN.Which ONE(1) of the following completes the statement below, assuming no operatoraction?The output on "C" Charging Pump speed controller will rise (1) and VCT levelwill (2)

.(1) and maintain PZR program level(2) rise(1) to maximum(2) rise(1) and maintain PZR program level(2) remain the same(1) to maximum (2) remain the same A.B.C.D.

65

ILC-11-2 NRC ExamThe correct answer is B.

A. Incorrect - The charging pump speed will rise to attempt to maintain PZR level,however, all the charging flow will be routed through the recirc line and PZR level willnot be maintained. The VCT level will rise due to no change in letdown flow plus all the charging pump recirc flow entering the VCT through the seal return line.B. Correct - All charging flow will be routed through the recirculation line and the AUTOcharging pump speed controller will go to maximum due to lowering PZR level. Sinceall charging flow is through the recirculation line back into the VCT along with normalletdown flow, the VCT level will rise.C. Incorrect - The charging pump speed will rise to attempt to maintain PZR level,however, all the charging flow will be routed through the recirc line and PZR level willnot be maintained. The candidate may think that the recirc line ties back into theletdown line. D. Incorrect - The first part of the distractor is correct. The candidate may think that therecirc line ties back into the letdown line.

Question 30Tier/Group 2/1 K/A Importance Rating - RO 2.7 SRO 3.0Knowledge of the effect of a loss or malfunction on the following CVCS components:Recirculation path for charging pumpsReference(s) - Sim/Plant design, CVCS System DescriptionProposed References to be provided to applicants during examination - NoneLearning Objective - CVCS-009Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.7 / 45.7Comments - K/A match because candidate is given a situation where the recirc pathhas been aligned to the VCT and a Charging Pump Discharge Valve is still open for anidle Charging Pump. The candidate must determine that all charging flow will be directed to the VCT causing PZR Level to lower and all charging flow will be lost to theregenerative heat exchanger causing the outlet temperature to rise.Discussion with P. Capehart concerning K/A:RNP's charging pump recirculation path is normally isolated and consists of manuallyoperated valves. Agreed that it would be acceptable to write a question againstoperation of manual valve(s) or leakby and identify the impact on CVCS system.Reviewed and approved by MAB.

66

ILC-11-2 NRC Exam

31. 005 K3.01 001Given the following plant conditions:Initial Conditions - Plant is in Mode 5 with the RCS depressurized. - "A" RHR Pump is in-service. - FC-605, RHR HX BYPASS FLOW, is in Manual with flow set at 3400 gpm.Current Conditions - APP-001-A7, RHR HX LO FLOW, is received. - Observed that SI-863A, RHR Loop Recirc, valve indicates dual position.Which ONE (1) of the following completes the statement below?Based on the conditions above, RCS Temperature will (1) and RCS Level will (2)

.(1) rise(2) lower(1) rise(2) remain stable(1) lower(2) lower(1) lower (2) remain stable A.B.C.D.

67

ILC-11-2 NRC ExamThe correct answer is A A. Correct - With SI-863A indicating dual (partially open) RHR HX outlet flow will bedirected back to the RWST. This will result in a lowering RCS level due to a loss ofinventory. The redirection of flow back to the RWST will result in a less RHR HX discharge reaching the core thus resulting in an RCS temperature rise. Actual RHRflow will lower since FC-605 is in manual.B. Incorrect - The first part of the distractor is correct. The second part is plausible ifthe candidate thinks that SI-8 63A recircs back to the suction of the RHR pumps insteadof the RWST. If this was the case then RCS level would remain stable.C. Incorrect - Candidate may think that since there is more flow through the RHR HXthat the RCS temperature will lower. Second part of distractor is correct. D. Incorrect - Candidate may think that since there is more flow through the RHR HXthat the RCS temperature will lower. The second part is plausible if the candidate thinksthat SI-863A recircs back to the suction of the RHR pumps instead of the RWST. If thiswas the case then RCS level would remain stable.

68

ILC-11-2 NRC Exam Question 31Tier/Group 2/1 K/A Importance Rating - RO 3.9 SRO 4.0Knowledge of the effect that a loss or malfunction of the RHRS will have on thefollowing: RCSReference(s) - Sim/Plant design, AOP-020, System DescriptionProposed References to be provided to applicants during examination - NoneLearning Objective - RHR 009Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.7 / 45.6 Comments - MAB Comment:

In the stem - how many RCPs have been secured? Would it bebetter to state that "all" RCPs have been secured?

Changed stem to Mode 5 with theRCS depressurized.Do procedures allow more than one RHR pump to be in operation? The stem statesthat the operating RHR pump trips. Does this leave open the possibility that an RHRpump is still operating?

Revised the question. Operating RHR Pump no longertrips.Delete all the extra unnecessary stuff in the answer choices - the only effect it has is toreduce plausibility. Just include the amount of information needed to make 4 uniqueanswer choices. The answer choices should look something like:A.RCS pressure will rise; RCS temperature will riseB.RCS pressure will lower; RCS temperature will riseC.RCS pressure will rise; RCS temperature will lower D. RCS pressure will rise; RCS temperature will lowerReformated the answer choices to minimize the length of answers.There may be an overlap issue with Q 29 (004K5.30). Knowledge from Q29 includesknowing that an increase in temperature will result in an increase in pressure duringsolid operating conditions. This question tests what will happen to RCS pressure whenyour cooling pump is tripped (I.E. temp increase). I understand the argument that thepump has tripped and this could impact pressure - but there still may be some overlap/ double jeopardy issues.

Revised the question to remove the overlap issue.No explanation was provided to help me understand why a temperature decrease isplausible. Currently I do not see plausibility in temperature lowering when my coolingpump trips and stops moving coolant. Therefore, unless convinced otherwise, "C" and "D" are not plausible.

Question revise to improve plausibility of distractors.Revised format of question to separate the init ial conditions and currentconditions.

69

ILC-11-2 NRC Exam

32. 006 K5.10 001Which ONE (1) of the following identifies the reason for RCP restart IAW FRP-P.1,RESPONSE TO IMMINENT PRESSURIZED THERMAL SHOCK, if the SI terminationcriteria cannot be satisfied?Restores PZR spray to allow RCS depressurization in subsequent steps.Equalizes S/G pressures to allow simultaneous cooldown of all three loops insubsequent steps.Mixes Safety Injection water and RCS water to ensure adequate shutdown margin.Mixes Safety Injection water and RCS water to raise the fluid temperature enteringthe Reactor Vessel downcomer.

A.B.C.D.The correct answer is D.A. Incorrect - Restoring RCPs will allow for restoration of PZR spray, however this is notthe basis for starting the RCPs when SI termination criteria cannot be satisfied. PZRspray is utilized in FRP-P.1 to reduce RCS pressure.B. Incorrect - Restoring Reactor coolant flow will equalize S/G pressure to an extent. However, further cooldown is not a mitigative strategy in FRP-P.1.C. Incorrect - This distractor is similar to the basis for starting RCPs in FRP-C.1 with theexception of "to ensure adequate shutdown margin." Adequate shutdown margin ismaintained by the fact that all rods have been inserted.D. Correct.

70

ILC-11-2 NRC Exam Question 32Tier/Group 2/1 K/A Importance Rating - RO 2.5 SRO 2.9Knowledge of the operational implications of the following concepts as they apply toECCS: Theory of thermal stressReference(s) - Sim/Plant design, FRP-P.1BDProposed References to be provided to applicants during examination - NoneLearning Objective - FRP-P.1-003Question Source - BANK (Not used on NRC Exam from 2004 to Present.)

Question Cognitive Level - H 10 CFR Part 55 Content - 41.5 / 45.7 Comments - MAB comment:

Do procedures ever allow terminating SI when termination criteria are not met? NO If so, then I will view "C" as plausible, if not, then "C" wi ll not be plausibleand will need to be modified or replaced.

Revised "C" to remove the implication ofterminating SI when the criteria are NOT satisfied. Change "C" to imply that theRCPs are started to ensure proper mixing to ensure adequate shutdown margin is maintained.

71

ILC-11-2 NRC Exam

33. 007 A1.01 001Which ONE(1) of the following completes the statements below?The PRT high level alarm setpoint is (1)

. The basis for this setpoint is to minimize the possibility of (2)

.(1) 91%(2) challenging the rupture discs following a 100% Load Rejection without a reactortrip(1) 83%(2) challenging the rupture discs following a 100% Load Rejection without a reactortrip(1) 91%(2) thermally shocking the pressurizer safeties and PORVs which could cause them to leak(1) 83%(2) thermally shocking the pressurizer safeties and PORVs which could cause them to leak A.B.C.D.The correct answer is D.A. Incorrect - 91% is the High PZR Level Reactor Trip setpoint. Candidate may thinkthe higher level has reduced the PRTs ability to quench the steam if a Safety lifted. The safety valves are sized to handle the maximum surge rate resulting from acomplete loss of load without reactor trip.B. Incorrect - The first part of the distractor is correct. Candidate may think the higherlevel has reduced the PRTs ability to quench the steam if a Safety lifted. The safetyvalves are sized to handle the maximum surge rate resulting from a complete loss ofload without reactor trip.C. Incorrect - 91% is the High PZR Level Reactor Trip setpoint. The second part of the distractor is correct.D. Correct

72

ILC-11-2 NRC Exam Question 33Tier/Group 2/1 K/A Importance Rating - RO 2.9 SRO 3.1Ability to predict and/or monitor changes in parameters (to prevent exceeding designlimits) associated with operating the PRTS controls including: Maintaining quench tank water level within limitsReference(s) - Sim/Plant design, OP-103, System Description, ITS BasesProposed References to be provided to applicants during examination - NoneLearning Objective - PZR 004 Question Source - NEW Question Cognitive Level - F 10 CFR Part 55 Content - 41.5 / 45.5 Comments - MAB Comment:

Why is all the stuff at the beginning of the question provided? Whatimportance or function does it have? Would this be the same question if it started withWhich ONE (1) of the following?

Revised the question to simply ask for the setpoint and basis.Considering the above comment, is this a (F)undamental LOK vs. a (H)igher LOK? Itseems like the applicant just needs to recognize the setpoint and know the basis, whichwould be a lower cognitive question.

Changed cognitive level to an F.

73

ILC-11-2 NRC Exam

34. 007 K3.01 001Given the following plant conditions: - The plant had been operating at 100% RTP when a Reactor Trip and SafetyInjection occurred due to a faulted steam line outside containment. - While performing PATH-1 actions the following indications were observed: - APP-003-D3, PRT HI/LO LEVEL

- APP-003-C3, PRT HI PRESS, alarmed and cleared - R-2, CV Low Range Monitor - Stable

- CV Sump Level - RisingWhich ONE(1) of the following identifies the cause of the indications given? SI-857B, Loop "B" Cold Leg Inj Relief to PRT, failed open Reactor Vessel Head inner o-ring failsPZR Safety Valve failed open"A" RCP #2 seal failure A.B.C.D.The correct answer is A.A. Correct - B. Incorrect - This failure would give you the CV indications if the outer o-ring had alsofailed. Would not give you the PRT indications. The inner o-ring leakage goes to theRCDT.C. Incorrect - A Safety Valve failing open resulting a the PRT Rupture disc failing wouldresult in R-2 indications rising. All other indications would be expected.D. Incorrect - A failure of #2 seal would give you indications of a rising level in theRCDT, but not the PRT.

74

ILC-11-2 NRC Exam Question 34Tier/Group 2/1 K/A Importance Rating - RO 3.3 SRO 3.6Knowledge of the effect that a loss or malfunction of the PRTS will have on thefollowing: ContainmentReference(s) - Sim/Plant design, APP-003-D3, System DescriptionProposed References to be provided to applicants during examination - NoneLearning Objective - PZR 007Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.7 / 45.6 Comments - MAB Comment:

Analysis of answer choice "A": What would PRT pressure do if CL InjRV failed open? Your analysis states that the high PRT pressure alarm will not comein - is this true?

The high PRT pressure alarm would only come in if it filled thePRT.None of the second set of conditions is needed for this question. Delete all of it unlessthere is a reason that it needs to stay. Remember that adding unnecessary informationdoes not help match a KA, etc. If it is not needed to answer the question, then it hasno impact on the KA match.

Regrouped the information in the Stem of questionand removed unnecessary information.Modification Idea: I would consider deleting the PRT Hi Temp alarm to make the sourcethe CL inj RV and test whether sump level will go up and whether R-2 will rise. Revised as recommended.Are there any differences in indications between a PORV failing open and a SafetyValve failing open?

A Safety Valve failing open would result in immediate receiptof Accoustic Monitoring Alarms. All other indications w ould be identical.The question states, "assuming no operator action." Appendix E disallowsassumptions. Simply state that no operator actions have taken place, rather thantelling the applicants to make an assumption. I would suggest doing a word search onthe entire exam and try to remove the word assume wherever possible. There is noharm in stating that no operator actions have occurred, but this is also part of the rulesfor taking the test as stated in Appendix E.

Removed the "assum ing no operatoraction" statement.

75

ILC-11-2 NRC Exam

35. 008 G2.4.50 001Given the following plant conditions: - Unit has experienced a LBLOCA. - EPP-10, Transfer to Long Term Recirculation, has been implemented. - APP-002-E5, SI PMP COOL WTR LO FLOW, is received.Which ONE(1) of the following completes the statements below IAW APP-002-E5?The SI Pump Cooling Water Low Flow alarm setpoint is __(1)__ GPM. APP-002-E5 requires the operator to __(2)

__ .(1) 100 (2) continue operation of the SI Pump(1) 50 (2) continue operation of the SI Pump(1) 100(2) stop the SI Pump immediately(1) 50 (2) stop the SI Pump immediately A.B.C.D.The correct answer is DA. Incorrect - APP-002-E5 states "If SI Pumps are operating under non-emergencyconditions OR long term recirculation, THEN STOP the pumps." The candidate maynot remember the exact wording in the APP and think that since they are still in theEOP network that running the pump with a cooling water low flow alarm is prudent. Thesetpoint for FIC-658, CCW SI Pump Flow Indicator, is 50 GPM and the 100 GPM is thesetpoint for the RCP thermal barrier high flow. Also, 100 gpm is the low flow setpointfor CCW to CRDM LO FLOW.B. Incorrect - See discussion in A above.C. Incorrect - The setpoint for FIC-658 , CCW SI Pump Flow Indicator, is 50 GPM andthe 100 GPM is the setpoint for the RCP thermal barrier high flow. Also, 100 gpm is thelow flow setpoint for CCW to CRDM LO FLOW. The second part of the distractor iscorrect. D. Correct

76

ILC-11-2 NRC Exam Question 35Tier/Group 2/1 K/A Importance Rating - RO 4.2 SRO 4.0Component Cooling Water System (CCWS): Ability to verify system alarm setpointsand operate controls identified in the alarm response manual.Reference(s) - Sim/Plant design, APP-002-E5, System Description, APP-001, OST-155Proposed References to be provided to applicants during examination - NoneLearning Objective - SI SD-002-009Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.10 / 43.5 / 45.3 Comments - MAB Comment:

Test what the operator is "required" to do - not what he will do. Do asearch of the entire exam (I know the word will appears elsewhere). Change thesecond part of the question prefix to: APP-002-E5 requires the operator to

_______________.

Revised as recommended.Make similar changes throughout the exam. We must test what operators are requiredto do because who knows what they will do.

Noted.Distractors A(2) and B(2) are not plausible. From a common sense perspective, asafety related pump has no cooling during a surveillance test (non-emergency), so it only makes sense to protect that pump by stopping it. There is not much plausibilityhere. Changed the stem of the question to have the pump operating on long termrecirculation following a LOCA. The action in the APP still directs that the pumpbe stopped immediately, but it does improve the plausibility of continuing to runthe pump since still in the EOP network.

77

ILC-11-2 NRC Exam

36. 010 K1.03 001Given the following plant conditions: - The plant is in Mode 1 at 100% RTP - The Pressurizer Pressure Controller, PC-444J, is in AUTOMATICWhich ONE (1) of the following identifies how RCS pressure and PC-444J Controlleroutput will respond if the controller potentiometer setpoint is lowered from 6.7 to 6.4 ?

RCS Pressure

Controller Output (Demand)

Rise

Rise Rise Lower Lower Rise Lower Lower A.B.C.D.The correct answer is C.A. Incorrect - Lowering the setpoint will cause the controller to maintain pressure in alower pressure band. Therefore pressure will lower. RNP does have controllers thatare reverse acting such as the S/G PORV controllers. The second part of the distractoris correct for the given conditions.B. Incorrect - Lowering the setpoint will cause the controller to maintain pressure in alower pressure band. Therefore pressure will lower. RNP does have controllers thatare reverse acting such as the S/G PORV controllers. The second part of the distractoris correct for a rise in RCS pressure.C. Correct.

D. Incorrect - The first part of the distractor is correct. PC-444J output signal rises tolower the pressure to the new setpoint.

78

ILC-11-2 NRC Exam Question 36Tier/Group 2/1 K/A Importance Rating - RO 3.6 SRO 3.7Knowledge of the physical connections and/or cause-effect relationships between thePZR PCS and the following systems: RCSReference(s) - Sim/Plant design, System DescriptionProposed References to be provided to applicants during examination - NoneLearning Objective - PZR 007Question Source - BANK (Not used on NRC Exam from 2004 to Present.)

Question Cognitive Level - H 10 CFR Part 55 Content -

41.2 to 41.9 / 45.7 to 45.8Comments -

79

ILC-11-2 NRC Exam

37. 010 K4.01 001Which ONE(1) of the following completes the statement below?A design feature of the Pressurizer maintains a small amount of flow in the spray linesin order to ........reduce the potential for water hammer upon spray initiation.maintain a small differential across the spray valves.maintain a constant firing rate to the Control Group heaters.reduce thermal stresses in the spray piping and auxiliary spray connection.

A.B.C.D.The correct answer is D.A. Incorrect - The small amount of flow in the spray lines may assist in minimizing thepotential for water hammer, however, a slight water hammer or pressure surge in thespray line occurs when initiating spray flow. The design concern is for reducing thermalstresses in the spray piping and auxiliary spray connection by maintaining a small amount of flow at all times.B. Incorrect - Although this flow does minimize the D/P across the spray valves this isnot the reason for maintaining a continuous flow.C. Incorrect- A constant flow to the pressurizer could "theoretically" be established tomaintain a constant firing rate. This flow rate is not known nor attempted to beestablished.D. Correct - Exert from PZR System

Description:

A small continuous spray flow isprovided, by means of the throttle valves (needle valves) which bypass the sprayvalves, to help ensure that the PZR liquid is in chemical equilibrium with the rest of thereactor coolant system (RCS) and to prevent thermal shock of the spray piping andthe auxiliary spray connection.

80

ILC-11-2 NRC Exam Question 37Tier/Group 2/1 K/A Importance Rating - RO 2.7 SRO 2.9Knowledge of PZR PCS design feature(s) and/or interlock(s) which provide for thefollowing: Spray valve warm-upReference(s) - Sim/Plant design, System DescriptionProposed References to be provided to applicants during examination - NoneLearning Objective - PZR 004Question Source - BANK (Not used on an NRC Exam from 2004 to present.)

Question Cognitive Level - F 10 CFR Part 55 Content - 41.7 Comments - MAB Comment:

Is "A" arguably correct? Will water continually pass through the spraynozzle? Could the nozzle be considered full? How is full defined for the spray nozzle? We need to ensure that "A" is not a correct answer choice. If needed, it will be replaced. We can discuss if you have the documentation that supports it as beingincorrect. I have concerns because the mechanism for reducing thermal stresses is tohave a continuous stream of water. Are we then testing the definition of what a fullspray nozzle is to differentiate between "A" and "D"?Revised "A" from "maintain PZR spray nozzle full of subcooling water" to"reduce the potential for water hammer upon spray initiation."

81

ILC-11-2 NRC Exam

38. 012 A3.05 001Given the following plant conditions: - Unit at 30% RTP - Power Range channel N-43 has been removed from service IAW OWP-011 tosupport drawer calibration.Subsequently:

- Inverter A tripsWhat impact will the failure have on the Reactor Protection System?Reactor will trip from Power Range High Flux (HIGH) setpoint.Reactor will trip from Power Range High Flux (LOW) setpoint.Reactor will trip from Intermediate Range High Flux trip.Reactor will NOT trip.

A.B.C.D.The correct answer is AA. CorrectB. Incorrect - With N-43 being removed from service IAW OWP-011, the bistables forOvertemperature Delta T, Overpower Delta T and Power Range High Flux (HIGH)setpoint have been manually tripped. The bistable for Power Range High Flux (LOW)setpoint is NOT tripped due to power being above the P-10 permissive setpoint (10%).With the failure of Inverter A, Instrument Busses 2 and 7A/7B will be de-energized andresult in all of the bistables associated with Channel 2 tripping from the loss of power,thus the reactor will trip from the N-42 and N-43 high flux trip (HIGH) bistables beingtripped.

C. Incorrect - See discussion above. A loss of Inverter "A" will result in a loss in IB 2and 7A/7B. This loss will result in a loss of NI-36 (IRNI). At the given power levels theIR High Flux Trip has been bypassed.D. Incorrect - Although N-43 is bypassed the bistables for its associated trips areinserted when removing it from service. This changes the PRNI coincidence from 2 of4 to 1 of 3. Therefore, the reactor will trip on a loss of Inverter "A" and IBs 2 and 7A/B.

82

ILC-11-2 NRC Exam Question 38Tier/Group 2/1 K/A Importance Rating - RO 3.6 SRO 3.7Ability to monitor automatic operation of the RPS, including: Single and multiplechannel trip indicatorsReference(s) - Sim/Plant design, System Description, OWP-011Proposed References to be provided to applicants during examination - NoneLearning Objective - RPS 006 Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.7 / 45.5 Comments - MAB Comment:

"C" and "D" not plausible because they are not mutually exclusiveanswer choices. Knowing that there cannot be two correct answers makes these twochoice not plausible.: How are "C" and "D" different? N-42 is bypassed for bothanswer choices and power is above P-10 for both answer choices. N-42 beingbypassed would play into both answer choices, thereby creating a subset issue. Thesetwo answer choices are not mutually exclusive. Suggest making "D" simply: "Reactorwill not trip." Then replace "C" to another credible mechanism that could trip thereactor.

Revised "C" from "NOT trip due to power being >P-10 permissive" to"trip from Intermediate Range High Flux trip." Change stem of question to raisepower to 30%, N-43 vice N-42 is removed from service and Inverter A trips. Thiswas necessary for plausibility of "C".

83

ILC-11-2 NRC Exam

39. 013 K2.01 001Which ONE (1) of the following identifies the power supply to the ESFAS interposingrelays? Train "A"

Train "B" IB-7A IB-3 IB-6 IB-9 IB-2 IB-8 IB-1 IB-4 A.B.C.D.The correct answer is A.A. Correct.B. Incorrect. Instrument Buses 6 and 9 are powered from MCC-5 and MCC-6,respectively. This would equate to a separation of trains similar to Instrument Buses7A and 3 which are powered from MCC-A and MCC-B, respectively.C. Incorrect. These selections are instrument busses that are supplied via MCC-A andMCC-B similar to the correct answers.D. Incorrect. Instrument Buses 1 and 4 are powered from MCC-5 and MCC-6,respectively. This would equate to a separation of trains similar to Instrument Buses7A and 3 which are powered from MCC-A and MCC-B, respectively.

Question 39Tier/Group 2/1 K/A Importance Rating - RO 3.6 SRO 3.8Knowledge of bus power supplies to the following: ESFAS/safeguards equipment controlReference(s) - Sim/Plant design, System Description.Proposed References to be provided to applicants during examination - NoneLearning Objective - ESF 003Question Source - BANK (Not used on an NRC Exam from 2004 to present.)

Question Cognitive Level - F 10 CFR Part 55 Content - 41.7 Comments -

84

ILC-11-2 NRC Exam

40. 022 A3.01 001A Large Break LOCA concurrent with a loss of the Startup Transformer has occurred. - Train "A" Engineered Safeguards Sequencer did NOT automatically actuate. - Both "A" and "B" CV Spray Pumps tripped.Which ONE (1) of the following completes the statement below?The MINIMUM action required to ensure containment pressure remains below itsdesign limit is to verify (1) automatically started AND manually start (2) andensure all associated cooling water outlet low flow alarms are clear.(1) HVH-3 OR HVH-4(2) HVH-1 OR HVH-2(1) HVH-3 AND HVH-4(2) HVH-1 AND HVH-2(1) HVH-1 OR HVH-2(2) HVH-3 OR HVH-4(1) HVH-1 AND HVH-2(2) HVH-3 AND HVH-4 A.B.C.D.The correct answer is B.A. Incorrect. With no CV Spray pumps operating, all four CV HVH units are required tomaintain CV design pressure.B. Correct.

C. Incorrect. Trains are swapped. With no CV Spray pumps operating, all four CV HVHunits are required to maintain CV design pressure.D. Incorrect. Trains are swapped. Train "B" components need to be verified runningand Train "A" components must be manually started.

85

ILC-11-2 NRC Exam Question 40Tier/Group 2/1 K/A Importance Rating - RO 4.1 SRO 4.3Ability to monitor automatic operation of the CCS, including: Initiation of safeguardsmode of operationReference(s) - Sim/Plant design, System DescriptionProposed References to be provided to applicants during examination - NoneLearning Objective - ESF 007Question Source - BANK (Last used on 2004 NRC Exam. Question format modified.)

Question Cognitive Level - H 10 CFR Part 55 Content - 41.7 / 45.5 Comments -

86

ILC-11-2 NRC Exam

41. 022 A4.05 001Given the following plant conditions: - It is July 31 and the plant is at 100% RTP. - Containment temperatures have been slowly approaching the ITS limit. - ERFIS has just failed.Which ONE(1) of the following identifies the correct order of preference for obtaining the "official" Containment Temperature IAW PLP-118, Hot Weather Operations? 1. RTGB Edge meter 2. Make a containment entry to obtain temperature readings. 3. Perform SPP-035, Containment Bulk Average Temperature Measurement1, 2, 31, 3, 22, 1, 33, 1, 2 A.B.C.D.The correct answer is D.A. Incorrect - RNP has very limited containment temperature instrumentation. Thesetemperature instruments are located in the RCP Pump Bays and on the CV OperatingDeck. These do not provide a representative indication of the Bulk CV Temperature. SPP-035 uses temperature resistance readings from the five CV temperature probesand processes the information through MathCad program to compute a Bulk WeightedCV Temperature.B. Incorrect - See discussion in "A" C. Incorrect - See discussion in "A". A containment entry to obtain temperatures wouldbe a last resort based on personnel safety implications.D. Correct.

87

ILC-11-2 NRC Exam Question 41Tier/Group 2/1 K/A Importance Rating - RO 3.8 SRO 3.8Ability to manually operate and/or monitor in the control room: Containment readings oftemperature, pressure, and humidity systemReference(s) - Sim/Plant design, PLP-118, SPP-035Proposed References to be provided to applicants during examination - NoneLearning Objective - CVHVAC 007Question Source - NEW Question Cognitive Level - F 10 CFR Part 55 Content - 41.7 / 45.5 to 45.8 Comments -

88

ILC-11-2 NRC Exam

42. 026 K1.01 001Given the following plant conditions: - A Large Break LOCA and Loss of Offsite Power have occurred. - EDG B tripped while starting. - RWST is at 9% level. - Alignment to the CV Sump has been completed. - CV Pressure is currently 12 psig.Which ONE (1) of the following completes the statement below?SI-844A and B, CV Spray Pump Suction Isolation Valves, will be (1) and RHRPump A is capable of supplying suction to CV Spray Pump(s)

(2)

. (1) closed(2) "A" ONLY(1) closed(2) "A" and "B"(1) open(2) "A" ONLY(1) open (2) "A" and "B" A.B.C.D.

89

ILC-11-2 NRC ExamAnswer is D A. Incorrect - SI-844A/B are normally open valves and are not impacted by the loss ofE2. SI-844A/B are not cycled prior to or during alignment for piggy-back mode ofoperation. Without power to "B" train components only "A" CV Spray Pump will be operable. Also, Attachment 1 of EPP-9 closes RHR Pump Suction Valves RHR-752A/B prior to initiating cold leg recirculation. The candidate could confuse this with having to close SI-844s. The candidate may think that RHR Pump "A" can not bealigned to supply suction to both trains of spray with only E-2 available.B. Incorrect - SI-844A/B are normally open valves and are not impacted by the loss ofE2. SI-844A/B are not cycled prior to or during alignment for piggy-back mode ofoperation. The second part of the distractor is correct. C. Incorrect - The first part of the distractor is correct. The candidate may think thatRHR Pump "A" can not be aligned to supply suction to both trains of spray with onlyE-2 available.D. Correct - SI-844A/B are not cycled prior to or during alignment for piggy-back modeof operation. RHR Pump "A" can still be aligned to supply suction pressure to both "A"and "B" CV Spray Pump.

90

ILC-11-2 NRC Exam Question 42Tier/Group 2/1 K/A Importance Rating - RO 4.2 SRO 4.2Knowledge of the physical connections and/or cause-effect relationships between theCSS and the following systems: ECCSReference(s) - Sim/Plant design, System Description, EPP-9Proposed References to be provided to applicants during examination - NoneLearning Objective - CSS SD-024-009Question Source - NEW Question Cognitive Level - F 10 CFR Part 55 Content -

41.2 to 41.9 / 45.7 to 45.8Comments - MAB Comment:

The second part of the answer choices are confusing. It appears thatthe "A" RHR pump will in fact supply suction to allow operation of both spray pumps. Itis true that the "B" spray pump does not have power, but its operation is not disalloweddue to the RHR supply. It also strikes me as strange to see "operation" underlinedhere. Seeing that underlined may, in fact, validate my comment here in that the RHRsupply has no impact on the operation of the Spray Pump. This ambiguity could lenditself to more than one correct answer because the RHR supply does allow operation ofboth spray pumps.This question appears to test two knowledge items: (1) the power supply to the "B"Spray Pump, and (2) the position of SI-844A&B.Revised the second part of the question from "RHR Pump A will supply suctionto allow operation of CV Spray Pump(s)" to "RHR Pump A is capable of supplyingsuction to CV Spray Pump(s)". This changes the focus of the question to howthe loss of power impacts the ability to align the ECCS system with CSS.

91

ILC-11-2 NRC Exam

43. 026 K3.02 001Given the following plant conditions: - The plant had been operating at 100% RTP when a Large Break LOCA occurred. - A malfunction in the CV Spray System results in FI-949,Spray Additive Flow,indicating higher than actual flow. - The crew has transitioned to "Piggy-Back" Mode IAW EPP-9, Transfer to Cold LegRecirculation, with CV Pressure at 14 psig. - Spray Additive Tank level is currently 60%.Which ONE(1) of the following completes the statement below?

The resultant operational implication of FI-949 failure is that during cold legrecirculation ECCS components will be more susceptible to (1) and IAW EPP-9the required CV Sump pH is (2)

. (1) chloride stress corrosion(2) 8.5 - 10.5(1) chloride stress corrosion(2) greater than 10.5(1) gas binding(2) greater than 10.5(1) gas binding (2) 8.5 - 10.5 A.B.C.D.

92

ILC-11-2 NRC ExamThe correct answer is A.

A. Correct - Since the indicated flow is higher than actual flow then less than expectedNaOH will have been delivered to the sump, therefore the pH will be less thanexpected. The expected CV Sump pH is 8.5 - 10.5.B. Incorrect - The first part of the distractor is correct. 10.5 is the upper range of thedesired pH. Candidate may incorrectly think that it is desired to have highly causticsump water.C. Incorrect - Gas intrusion is a recent industry concern for ECCS components andpiping. Candidate may this is the concern. 10.5 is the upper range of the desired pH. Candidate may incorrectly think that it is desired to have highly caustic sump water.D. Incorrect - Gas intrusion is a recent industry concern for ECCS components andpiping. Candidate may this is the concern.The second distractor is correct.Exert from EPP-9Determine CV Sump pH As Followsa. Request Chemistry Personnel obtain an RHR sample, while continuing with this procedureb. Check RHR Sample Results - AVAILABLE

c. Check RHR pH -

GREATER THAN 8.5Exert from EPP-9BDThis step is necessary to check CV Sump pH for long term corrosion control per Westinghouse NSAL93-016. This letter describes the long term corrosion control concerns if a SBLOCA occurs which does not result in a Spray Actuation. Provisions are made to raise sump pH using Attachment 3 if pH is low.

pH is not expected to become excessively high. If SAT levels and concentrations are maintainedcorrectly pH should remain below the limit of 10.5. At this point the CV has been isolated and IVSWinitiated. It may not be possible to inject pH reducing agents to the CV until after radiation levels have decayed.

93

ILC-11-2 NRC Exam Question 43Tier/Group 2/1 K/A Importance Rating - RO 4.2 SRO 4.3Knowledge of the effect that a loss or malfunction of the CSS will have on the following:Recirculation spray systemReference(s) - Sim/Plant design, System Description, EPP-9BD (Step 48)Proposed References to be provided to applicants during examination - NoneLearning Objective - CSS SD-024-009Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.7 / 45.6 Comments - Discussion with P. Capehart on 6/15/11:

Clarified that "recirculation spraysystem" is equivalent to CV spray operation while in long-term recirculation(piggy-back) mode of operation.MAB Comment: RCS water is always acidic. PWRs use boric acid as one of the twoprimary means of reactivity control that are available to licensed operators. So whenfaced with a situation where chemicals cann ot be added due to the Add Tank Outletfailing closed, why would an operator believe that the sump water would be caustic? IfRobinson also uses TSP baskets in the sump or something like that, then there may besome plausibility for the water to be caustic.

Revised the question to ask resultantpH if NaOH flow is indicating higher than actual and the required CV Sump pH.I also struggle in seeing plausibility in the gas binding. Revised question to removethis portion of question.

94

ILC-11-2 NRC Exam

44. 039 K4.06 001Given the following plant conditions: - The plant is operating at 100% RTP. - Steam line break occurs on Steam Line A just outside the CV wall. - MSIV "A" fails to close when demanded.Which ONE (1) of the following identifies the design feature that will ensure that all ofthe S/Gs do NOT blowdown through the faulted steam line?MSIV auto closure on High Steam Line Flow with Low Tave signal.MSIV auto closure on High Steam Line Delta P signal.Check valves downstream of each MSIV.Check valves upstream of each MSIV.

A.B.C.D.Answer is CA. Incorrect - Check valves are installed on the downstream side of each of the MSIVs.These serve to ensure that back flow is prevented when a faulted steam line occurs onone steam line. MSIV auto closure signal does exist when 2 out of 3 steam lines have ahigh steam line flow signal, coincident with a Low Tave or Low Steam Line pressure,which provides protection for a steam break downstream of the MSIVs.B. Incorrect - High Steam Line Delta P signal will provide a Safety Injection signal for 1faulted S/G but does not provide any signal for closure of the MSIVs. C. CorrectD. Incorrect - The check valve design feature is correct but the location within thesystem is incorrect.

Question 44Tier/Group 2/1 K/A Importance Rating - RO 3.3 SRO 3.6Knowledge of MRSS design feature(s) and/or interlock(s) which provide for thefollowing: Prevent reverse steam flow on steam line breakReference(s) - Sim/Plant design, System Description, ITS 3.3.2 BasesProposed References to be provided to applicants during examination - NoneLearning Objective -MSS 004 Question Source - NEW Question Cognitive Level - F 10 CFR Part 55 Content - 41.7 Comments -

95

ILC-11-2 NRC Exam

45. 059 A2.04 001Given the following plant conditions: - Plant is operating in Mode 1 at 100% RTP. - A Reactor Trip and Safety Injection has occurred. - No AFW pumps are available. - RCS Bleed-and-Feed is in progress IAW FRP-H.1, Response to Loss ofSecondary Heat Sink. - Both Condensate Pumps are running.

Which ONE (1) of the following completes the statement below?To restore feed flow to the S/G(s) IAW FRP-H.1, the operator is required to place (1)

Feedwater Isolation Key Switch(es) in the OVRD/RESET position, verify the Feedwater Header Section Valves (2) and start 1 Main Feedwater Pump to feed (2)

S/G(s). (1) ONE(2) OPEN(3) ONE(1) THREE (2) OPEN (3) ONE (1) ONE (2) CLOSED(3) ALL(1) THREE(2) CLOSED(3) ALL A.B.C.D.

96

ILC-11-2 NRC ExamThe correct answer is D.

A. Incorrect -

Reference:

FRP-H.1 Pages 1 through 11. All key operated overrideswitches are placed in OVRD/RESET Position. All must be in OVRD/RESET and theFeedwater Header Section Valves must be closed to allow for starting of the MFP. 1MFP started and FRV Bypass opened. Candidate may think that only one FeedwaterIsolation Key Switch is utilized to over-ride all Feedwater Isolation signals similar to other over-ride switches on the RTGB. The Feedwater Header Section Valves must be closed to allow for starting of the MFP. All S/Gs are fed once feedwater flow isestablished.B. Incorrect - The first part of the distractor is correct. The Feedwater Header SectionValves must be closed to allow for starting of the MFP. All S/Gs are fed oncefeedwater flow is established.C. Incorrect - All key operated override switches are placed in OVRD/RESET Position. All must be in OVRD/RESET and the Feedwater Header Section Valves must beclosed to allow for starting of the MFP. 1 MFP started and FRV Bypass opened. Candidate may think that only one Feedwater Isolation Key Switch is utilized toover-ride all Feedwater Isolation signals similar to other over-ride switches on the RTGB. The second and third part of the distractor are correct. D. Correct.

97

ILC-11-2 NRC Exam Question 45Tier/Group 2 / 1 K/A Importance Rating - RO 2.9 SRO 3.4Ability to (a) predict the impacts of the following malfunctions or operations on theMFW; and (b) based on those predictions, use procedures to correct, control, ormitigate the consequences of those malfunctions or operations: Feeding a dry S/GReference(s) - Sim/Plant design, FRP-H.1Proposed References to be provided to applicants during examination - NoneLearning Objective - FRP-H.1-004 Question Source - ILC-09 NRC EXAM ModifiedQuestion Cognitive Level - F 10 CFR Part 55 Content -

41.5 / 43.5 / 45.3 / 45.13Comments - K/A match because candidate is given a situation where a plant tripoccurred with a loss of secondary heat sink. Bleed and Feed was required due to S/Glevels being low. The candidate must know how to manipulate the Feedwater IsolationSwitches to start a MFP and the flowpath that will be used to restore S/G levels.ILC-09 NRC EXAM Modification:ILC-09 question had the candidate determine if the S/Gs would be fed via the FRV orthe FRV Bypass Valve. This question has been modified to have the candidatedetermine the required position of the Feedwater Header Section Valves. Also, thequestion has been reformatted to a fill-in the blank.Reviewed and approved by MAB.

98

ILC-11-2 NRC Exam

46. 059 A3.02 001Which ONE (1) of the following completes the statement below?At 15% RTP the programmed S/G level is approximately (1) and at 20% RTP theprogrammed S/G level is approximately (2)

.(1) 52%(2) 52%(1) 49%(2) 52%(1) 39%(2) 39%(1) 29%

(2) 39%A.B.C.D.The correct answer is B.A. Incorrect. 52% is the programmed level from 20% to 100% RTP.B. Correct. The programmed levels are 39% to 52% from 0 to 20% power and aconstant 52% from 20% to 100% power.C. Incorrect. If the candidate incorrectly thinks that S/G levels are programmed at 39%level from 0 to 20% power and ramped from 39% to 52% from 20% to 100% power thisanswer would be correct. The numbers are correct, just misapplied.D. Incorrect. This value would be correct if programmed level was from 0 to 39% from 0to 20% RTP.

99

ILC-11-2 NRC Exam Question 46Tier/Group 2/1 K/A Importance Rating - RO 2.9 SRO 3.1Ability to monitor automatic operation of the MFW, including: Programmed levels of the S/GReference(s) - Sim/Plant design, System Description, Logic DiagramsProposed References to be provided to applicants during examination - NoneLearning Objective - FW 006Question Source - NEW Question Cognitive Level - F 10 CFR Part 55 Content - 41.7 / 45.5 Comments -

100

ILC-11-2 NRC Exam

47. 061 K5.01 001Given the following plant conditions:"B" MFP is OOS for Maintenance and the following occurs: - The Reactor was manually Tripped while operating at 20% RTP due to a tripof "A" MFP - Tave is 546°F and lowering.

- PZR Level is 22% and slowly lowering.

- RCS Pressure is 2045 psig and lowering.

- Steam Generator Blowdown is Isolated. - S/G levels are as follows: - "A" S/G Narrow Range level is 42% and slowly rising.

- "B" S/G Narrow Range level is 41% and slowly rising.

- "C" S/G Narrow Range level is 45% and slowly rising.Which ONE (1) of the following provides the action(s) that are required to be taken nextIAW EPP-4, Reactor Trip Response?Initiate Safety InjectionBorate to Cold Shutdown BoronReduce Auxiliary Feedwater FlowClose the MSIVs & MSIV Bypasses A.B.C.D.The correct answer is C.A. Incorrect - Safety Injection initiation criteria have not been met. PZR is greater than10%. PZR is lowering due to the RCS cooldown.B. Incorrect - EPP-4 will only direct borating to CSD Boron if RCS temperature lowersto less than 530°F.C. Correct - EPP-4 will direct the operator to reduce total feed flow to stop cooldownsince S/Gs are greater than 8%, S/G Blowdown is isolated and Tave is less than 547°Fand lowering.D. Incorrect - Closure of the MSIVs and MSIV Bypasses is only required if thereduction in feed flow does not stop the cooldown.

101

ILC-11-2 NRC Exam Question 47Tier/Group 2 / 1 K/A Importance Rating - RO 3.6 SRO 3.9Knowledge of the operational implications of the following conceptsas the apply to the AFW: Relationship between AFW flow and RCS heat transfer.Reference(s) - Sim/Plant design, System Description, EPP-4, EPP-Foldout HProposed References to be provided to applicants during examination - NoneLearning Objective -

AFW 010Question Source - ILC-11-1 NRC Exam Question Cognitive Level - H 10 CFR Part 55 Content -

41.5 / 45.7Comments - K/A met because candidate must analyze plant conditions given followinga plant trip due to a loss of main feedwater. Based on this analysis the candidate mustidentify the effect of AFW flow due to RCS temperature lowering and determine theappropriate actions of reducing AFW flow.MAB Comment:It looks like this question was used on a recent NRC exam (ILT 11-1). What methodology was used to select this question? How did you ensure that you randomlyselected among all of your bank questions that met this KA?

I search through ourmultiple banks and this was the only exact K/A match identified. If multiple K/Amatches are found then the questions are numbered and selected based on arandom number generator on Random.org.No comments on the question itself.

102

ILC-11-2 NRC Exam

48. 061 K6.02 001Given the following plant conditions: - The Plant is in Mode 3. - "B" MDAFW pump is running. - A small feedline break occurs between FCV-1425, MDAFW pump "B" FCV, and isolation valve V2-16C, SG C AFW Isolation Valve.

- FCV-1425 is closed and the break flow stops.The CRS has directed isolation of the leak from all water sources.Which ONE (1) of the following identifies the SGs available to be fed from "A" MDAFWpump?S/G "A" ONLYS/G "B" ONLYS/Gs "A" and "B" ONLYS/Gs "A", "B" and "C" A.B.C.D.The correct answer is C.A. Incorrect. "B" S/G can be fed using "A" MDAFW pump through V2-16B. B. Incorrect. "A" S/G can be fed using "A" MDAFW pump through V2-20A and V2-16A.C. Correct.

D. Incorrect. The break location requires that V2-16C and V2-20B be closed. "C" S/Gwould have to be fed via the SDAFW pump in an emergency condition.

Question 48Tier/Group 2 / 1 K/A Importance Rating - RO 2.6 SRO 2.7Knowledge of the effect that a loss or malfunction of the following will have on the AFWComponents: Pumps.Reference(s) - SD-042, Figure 2, Page 39 of 50Proposed References to be provided to applicants during examination - NONELearning Objective - AFW 003Question Source - BANK (Last used on 2007 NRC Exam.)

Question Cognitive Level - H 10 CFR Part 55 Content - 41.7 / 45.7 Comments -

103

ILC-11-2 NRC Exam

49. 062 A2.10 001Given the following plant conditions: - Unit operating at 50% RTP. - "A" Train of CR HVAC is in service. - Breaker 52/21A, Feed to MCC-5 (NORM POWER) & MCC-16, trips open. - CRS has directed that MCC-5 be transferred to the DS Bus.Which ONE (1) of the following completes the statements below?

MCC-16 __(1)__ re-energize when MCC-5 is transferred to the DS Bus. "A" Train of Control Room HVAC (2) be available.(1) will(2) will(1) will(2) will NOT(1) will NOT (2) will NOT(1) will NOT (2) will A.B.C.D.

104

ILC-11-2 NRC ExamThe correct answer is C.A. Incorrect - The feeder breaker on 480V Bus E-1 is a double lugged breaker andfeeds both MCC-5 and 16. The kirk key switch for MCC-5 transfer is downstream of thecable split which only supplies MCC-5 from the DS Bus when the kirk key switch istransferred. This causes MCC-16 to remain de-energized when the kirk key switch istransferred to the DS Bus. "A" Train of CR HVAC is powered from MCC-16 and will notbe available while MCC-5 is powered from the DS Bus.B. Incorrect - See discussion in "A" above.C. Correct - "B" Train of CR HVAC will start automatically upon a loss of "A" train.D. Incorrect - "A" Train will not have power available due to the MCC-16 beingde-energized.

Question 49Tier/Group 2/1 K/A Importance Rating - RO 3.0 SRO 3.3Ability to (a) predict the impacts of the following malfunctions or operations on the acdistribution system; and (b) based on those predictions, use proc edures to correct,control, or mitigate the consequences of those malfunctions or operations: Effects ofswitching power supplies on instruments and controlsReference(s) - Sim/Plant design, System Description, EDP-003Proposed References to be provided to applicants during examination - NoneLearning Objective - VAC 005 Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content -

41.5 / 43.5 / 45.3 / 45.13Comments -

105

ILC-11-2 NRC Exam

50. 063 A1.01 001Given the following plant conditions: - A Loss of Offsite Power has occurred. - BOTH EDGs have failed to auto start. - EPP-1, Loss of All AC Power, has been implemented.Which ONE (1) of the following completes the statement below with respect to loadshedding and station battery design?IAW EPP-1, low priority loads (1) required to be shed from Instrument Buses 2and 3 to minimize the discharge rate on both DC buses to assure that the stationbatteries achieve their (2) design time limitation. (1) are(2) 30 minute(1) are(2) 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />(1) are NOT(2) 30 minute(1) are NOT (2) 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> A.B.C.D.

106

ILC-11-2 NRC ExamThe correct answer is B.

A. Incorrect - The first part of distractor is correct. PATH-1 has a continuous action stepthat requires a battery charger to be restarted within 30 minutes of a power loss. The30 minutes is to allow for a 30 minute margin to the design limit of 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and ensuresthat the batteries are not completely discharged.B. Correct.C. Incorrect - EPP-1, Attachment 2, Load Shed Listing, contains a list of all low priorityloads that are to be shed to extend the life of the batteries. Attachment 2 contains loadsfrom both DC buses and Instrument Buses 2, 7B and 3. Instrument Buses 2 and 3 arepowered from Inverters A and B, respectively. PATH-1 has a continuous action stepthat requires a battery charger to be restarted within 30 minutes of a power loss. The 30 minutes is to allow for a 30 minute margin to the design limit of 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and ensuresthat the batteries are not completely discharged.D. Incorrect - EPP-1, Attachment 2, Load Shed Listing, contains a list of all low priorityloads that are to be shed to extend the life of the batteries. Attachment 2 contains loadsfrom both DC buses and Instrument Buses 2, 7B and 3. Instrument Buses 2 and 3 arepowered from Inverters A and B, respectively. The second part of the distractor iscorrect.

107

ILC-11-2 NRC Exam Question 50Tier/Group 2/1 K/A Importance Rating - RO 2.5 SRO 3.3Ability to predict and/or monitor changes in parameters associated with operating theDC electrical system controls including: Battery capacity as it is affected by dischargerateReference(s) - Sim/Plant design, System Description, EPP-1, EPP-1BDProposed References to be provided to applicants during examination - NoneLearning Objective - DC 004 Question Source - NEW Question Cognitive Level - F 10 CFR Part 55 Content - 41.5 / 45.7 Comments - MAB Comment:

The question statement does not address both parts of the question -it only asks for the time limitations. The question should solicit everything being askedfor in the fill in the blank and answer choices.

Added "and required actions toachieve this time limitation" to the stem of the question.C(1) and D(1) are not plausible. You have provided the applicants with two kinds ofloads to be shed, both of which would reduce load on the batteries. It is not crediblethat the applicant would choose to shed an inverter when the other choice is a LOWpriority load.

Revised the question to ask if loads are shed from both DC busesAND IB or DC buses ONLY.Revise the stem of the question to ask "Which ONE (1) of the followingcompletes the statement below with respect to load shedding and station batterydesign?" instead of "Which ONE (1) of the following identifies the time limitationsof the design capacity of the station batteries and required action to achieve thistime limitation?". Revision based on validation comments.

108

ILC-11-2 NRC Exam

51. 064 K6.07 001Given the following plant conditions: - APP-010-B2, EDG A START AIR LO PRESS, has been received. - EDG A Air Receiver relief valve DA-11A has lifted and blown down the air receiverpressure to 80 psig prior to reseating.

Which ONE (1) of the following identifies the LOWEST pressure at which the "A" EDG Air Receiver will be pressurized to a value that supports 8 cold starts of the EDG?

100 210 216 220 A.B.C.D.Answer is BA. Incorrect - At 100 psig the EDG is assured to start once if called upon.B. Correct - 210 psig is the ITS LCO 3.8.3 limit and assures that at least 8 cold starts ofthe EDG can be performed.C. Incorrect - The 216 psig air receiver pressure is the AIR START LO PRESS alarmsetpoint.D. Incorrect - The 220 psig air receiver pressure is the automatic starting pressuresetpoint for the EDG Air Compressor when in AUTO.

109

ILC-11-2 NRC Exam Question 51Tier/Group 2/1 K/A Importance Rating - RO 2.7 SRO 2.9Knowledge of the effect of a loss or malfunction of the following will have on the ED/Gsystem: Air receiversReference(s) - Sim/Plant design, OP-604, APP-010, ITS 3.8.4Proposed References to be provided to applicants during examination - NoneLearning Objective - EDG 008Question Source - NEW Question Cognitive Level - F 10 CFR Part 55 Content - 41.7 / 45.7 Comments - MAB Comments: What benefit does it add to test their ability to extrapolate to a point in time thatcoincides with a certain value? This is at least the third question that has done this. Does your air compressor raise pressure at a linear rate of 1 psig/min? If not, then thisis not an operationally valid question. Also, would you expect an operator to know therate at which a compressor will charge your EDG air receivers and then calculate thetime that will support 8 cold starts? Is this testing meaningful information?

Revised thequestion to simply ask for the EDG air receiver pressure value that supports 8cold starts of the EDG.I see no supporting documentation that supports the air receivers raising pressure at 1psig/min.Suggest just testing the various pressures (100, 210, 216, and 220).

110

ILC-11-2 NRC Exam

52. 073 G2.2.12 001Given the following plant conditions: - OST-924-2, Process Radiation Monitoring System, Section 8.10, Fuel HandlingBuilding Upper Level Monitor Test, is in progress. - The CKT TEST pushbutton on R-21 has been depressed and held in the depressed position.Given the above conditions, which ONE(1) of the following completes the statement?While the CKT TEST pushbutton is depressed, the operator is required to checkHVS-4 and (1)

OFF and when the CKT TEST pushbutton is released those fansare required to be checked (2)

.HVS-4, Fuel Handling Building Supply Air Handling UnitHVE-15, Spent Fuel Building Exhaust Air Handling UnitHVE-15A, Spent Fuel Building Exhaust Air Handling Unit(1) HVE-15(2) ON(1) HVE-15(2) OFF(1) HVE-15A(2) ON(1) HVE-15A (2) OFF A.B.C.D.

111

ILC-11-2 NRC ExamThe correct answer is A.A. CorrectB. Incorrect - The automatic functions provided by the Process Rad. Monitor will bedeactivated when the CKT TEST pushbutton is released. This is also specified in theOST to verify that the fans are ON once the CKT TEST pushbutton is released.C. Incorrect - HVE-15A includes charcoal filters and is placed in service whenperforming spent fuel activities. HVE-15A provides filtered exhaust for the spent fuelbuilding with HVS-4 providing the supply. R-21 does not have any automatic functionsassociated with HVE-15A.D. Incorrect - HVE-15A includes charcoal filters and is placed in service whenperforming spent fuel activities. HVE-15A provides filtered exhaust for the spent fuelbuilding with HVS-4 providing the supply. R-21 does not have any automatic functionsassociated with HVE-15A.

Question 52Tier/Group 2/1 K/A Importance Rating - RO 3.7 SRO 4.1Process Radiation Monitoring (PRM) System: Knowledge of surveillance procedures.Reference(s) - Sim/Plant design, OP-924-2, System DescriptionProposed References to be provided to applicants during examination - NoneLearning Objective - RMS 009Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.10 / 45.13 Comments - MAB Comments: Add to the question statement that you are asking the question with the CKT TESTpushbutton depressed iaw OST-924-2. I.E. Given the above conditions, which one ofthe following completes the statement?

Revised stem of question as recommended.

112

ILC-11-2 NRC Exam

53. 076 G2.4.18 001Given the following plant conditions: - A plant trip and safety injection has occurred due to multiple events. - The crew is implementing PATH-1. - "C" and "D" SW Pumps have tripped and cannot be restarted. - North and South SW Header pressures are 35 psig.Which ONE(1) of the following completes the statement below?

Based on the conditions given above, an action required by PATH-1 to isolate theService Water Supply to the Turbine Building is to close valve (1) and the basisfor this action is to ensure (2)

.(1) V6-16A, SW NORTH HEADER SUPPLY TO TURBINE BUILDING(2) adequate cooling flow to the EDGs(1) V6-16C, SW ISOLATION TO TURBINE BUILDING(2) adequate cooling flow to the EDGs(1) V6-16A, SW NORTH HEADER SUPPLY TO TURBINE BUILDING(2) SW Booster Pumps will NOT trip on low SW pressure(1) V6-16C, SW ISOLATION TO TURBINE BUILDING (2) SW Booster Pumps will NOT trip on low SW pressure A.B.C.D.

113

ILC-11-2 NRC ExamThe correct answer is B.A. Incorrect - Only closing V6-16A will not isolate SW to the Turbine Building. V6-16Bmust also be closed or V6-16C. Candidate may think that since "C" and "D" SWPstripped that V6-16A is the only valve requir ed to be closed since these pumps supplythe North Header. The second part of the distractor is correct. B. Correct -

C. Incorrect - Only closing V6-16A will not isolate SW to the Turbine Building. V6-16Bmust also be closed or V6-16C. Candidate may think that since "C" and "D" SWPstripped that V6-16A is the only valve requir ed to be closed since these pumps supplythe North Header. Under normal and blackout conditions, if SW Booster pump suctionpressure drops below 12 psig for 10 seconds the SW Booster pump will trip. However, this is not the bases for isolating the turbine building on low header pressure.D. Correct. The first part of the distractor is correct. Under normal and blackoutconditions, if SW Booster pump suction pressure drops below 12 psig for 10 secondsthe SW Booster pump will trip. However, this is not the bases for isolating the turbinebuilding on low header pressure.

Question 53Tier/Group 2/1 K/A Importance Rating - RO 3.3 SRO 4.0Service Water System (SWS): Knowledge of the specific bases for EOPs.Reference(s) - Sim/Plant design, System DescriptionProposed References to be provided to applicants during examination - NoneLearning Objective - SW 007Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.10 / 43.1 / 45.13 Comments - MAB Comments:ONLY does not work in this case. Will PATH-1 have the operators close ANYTHINGelse? More precise language needs to be used here. I understand why you tried touse ONLY, because just closing 16A, without also closing 16B, will not isolate SW to the turbine building. By wording it in this fashion, there is also an argument that thereis no correct answer because closing 16C is not the only valve that PATH-1 will directto be closed.Added "to isolate the Service Water Supply to the Turbine Building" to the stemof the question. Removed the word "ONLY" from the stem.

114

ILC-11-2 NRC Exam

54. 078 K2.02 001Given the following plant conditions: - The unit tripped due to a loss of off-site power. - "A" EDG output breaker failed to close and cannot be manually closed. - EPP-25, Energizing Supplemental Plant Equipment using the DSDG, has beencompleted.Which ONE(1) of the following identifies the air compressor(s) available to be restartedunder these conditions?Instrument Air Compressor "A" ONLYInstrument Air Compressor "B" ONLYInstrument Air Compressors "A" AND "B" ONLYInstrument Air Compressors "A" AND "B" and the Primary Air Compressor.

A.B.C.D.The correct answer is C.A. Incorrect. "B" IAC is also available since E-2 is energized.B. Incorrect. "A" IAC is also available since MCC-5 has been energized by the DSDG. This answer would have been correct had EPP-25 not been implemented.C. Correct.

D. Incorrect. The Primary Air Compressor is powered from 480V Bus 2A. EPP-25does have steps to perform a backfeed that could re-energize 480V Bus 2A, however,this was not given in the stem of the question.

Question 54Tier/Group 2/1 K/A Importance Rating - RO 3.3 SRO 3.5Knowledge of bus power supplies to the following: Emergency air compressorReference(s) - Sim/Plant design, System Description, EDPs, EPP-25Proposed References to be provided to applicants during examination - NoneLearning Objective - AIR 005Question Source - NEW Question Cognitive Level - F 10 CFR Part 55 Content - 41.7 Comments -

115

ILC-11-2 NRC Exam

55. 103 A4.09 001Given the following plant conditions:Initial Conditions - Plant is in Mode 3 at 547°F and 2235 psig. - A spurious Safety Injection signal has been received.Current Conditions - EPP-7, SI Termination, has been completed. - APP-002-B7, CV NAR RANGE HI/LO PRESS illuminates. - CV Pressure indicates

- 0.4 psig and degrading.Which ONE (1) of the following identifies the actions necessary to clear the alarm IAWOP-921, Containment Air Handling?Reset Phase "A" and open Containment Pressure Relief Valves V12-10 andV12-11.Reset Containment Ventilation Isolation and open Containment Pressure ReliefValves V12-10 and V12-11.Reset Containment Ventilation Isolation and open Containment Vacuum ReliefValves V12-12 and V12-13.Reset Phase "A" and open Containment Vacuum Relief Valves V12-12 andV12-13.A.B.C.D.The correct answer is C.A: Incorrect. Resetting the Phase "A" will not allow the Pressure Relief Valves to open. The Containment Ventilation signal must be reset. Additionally, the vacuum reliefvalves are required to be opened based on given plant conditions.B: Incorrect. The first part of the distractor is correct. The vacuum relief valves arerequired to be opened based on the given plant conditions, not the pressure reliefvalves.C: Correct. Opening the CV Vacuum Relief valves will correct a negative pressure in the CV.D: Incorrect. Resetting Phase "A" will not allow the vacuum relief valves to open. TheContainment Ventilation Isolation signal must be reset.

116

ILC-11-2 NRC Exam Question 55Tier/Group 2/1 K/A Importance Rating - RO 3.1 SRO 3.7Ability to manually operate and/or monitor in the control room: Containment vacuumsystem.Reference(s) - Sim/Plant design, OP-921 Section 8.4.3, APP-002Proposed References to be provided to applicants during examination - NoneLearning Objective -CV-007, CVHVAC Objective 3 Question Source - NEW Question Cognitive Level - F 10 CFR Part 55 Content - 41.7 / 45.4 to 45.8 Comments - It looks like this question was used on a recent NRC exam (ILT 11-1). How was thisquestion selectedES-401: If the bank contains more than one question that fits a specific K/Astatement, randomly select from among the available questions unless there isan appropriate basis for selecting a specific question (e.g., higher cognitive level,better discrimination validity, more operationally oriented, or site-specific priority).No further comments.

A search was performed of our various test banks and thiswas the only question identified that had the exact K/A match. If additional questions are found with the exact K/A match then they are assigned a numberand selected based on a random number generator from Random.org.

117

ILC-11-2 NRC Exam

56. 001 A3.05 001Given the following plant conditions: - The plant is operating at 25% RTP. - Control Bank C step counters indicate 225 steps. - Control Bank D step counters indicate 105 steps. - Rod Control is in AUTOMATIC. - A malfunction in the Automatic Rod Control Circuitry causes the rods to insert. - The rods are stopped when the Rod Bank Selector Switch is taken to Manual(M). - The Group Step Counters for Control Bank C and D did not function properly. - A review of ERFIS identified that Control Bank D Rods inserted 10 inches.Which ONE(1) of the following identifies what the Group Step Counters for ControlBanks C and D would indicate if operating properly?

Bank C Bank D 217 steps 89 steps 223 steps 95 steps 215 steps 95 steps 209 steps 89 steps A.B.C.D.The correct answer is A.A. Correct. 10 inches equates to 16 steps. Control Bank D will step in 16 steps to 89steps. Control Bank C will not begin stepping in until Control Bank D is at 97 steps. Control Bank C will therefore only step in 8 steps to a final position of 217 steps.B. Incorrect - This distractor incorrectly correlates 10 inches of IRPI to 10 steps on theGroup Step Counters. The distractor for Bank C has to correct overlap assuming 10steps on Bank D.C. Incorrect - This distractor incorrectly correlates 10 inches of IRPI to 10 steps on theGroup Step Counters. The distractor for Bank C does not account for the properoverlap and incorrectly assumes that the Bank C rods will move once Bank D rods begin to insert. D. Incorrect - The position given for Bank D is correct. The position given for Bank Cdoes not account for proper overlap and incorrectly assumes that the Bank C rods willmove once Bank D ro ds begin to insert.

118

ILC-11-2 NRC Exam Question 56Tier/Group 2/2 K/A Importance Rating - RO 3.5 SRO 3.5Ability to monitor automatic operation of the Control Rod Drive System, including:Individual vs. group rod positionReference(s) - Sim/Plant design, System Description, ITSProposed References to be provided to applicants during examination - NoneLearning Objective -RDCNT 007 Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.7 / 45.13 Comments - .

119

ILC-11-2 NRC Exam

57. 011 K2.02 001Which ONE (1) of the following identifies (in the order presented) the normal powersupplies for the Pressurizer Heaters?Control Group

, Backup Group A

, Backup Group B

1. 480V Bus 12. 480V Bus 2A
3. 480V Bus 2B
4. 480V Bus 33, 1, 23, 2, 44, 3, 12, 1, 3 A.B.C.D.The correct answer is A.A. Correct.B. Incorrect. First P/S is correct. Bus 2A is the P/S for B/U Group B. Bus 3 does notprovide normal power supply but is used if necessary to energize pressurizer heatersthrough the DS Bus.C. Incorrect. Bus 3 does not provide normal power supply but is used if necessary toenergize pressurizer heaters through the DS Bus. The second and third choices doprovide power to PZR heaters, just not to those groups.D. Incorrect. All three of the busses provide power to pressurizer heaters, they arelisted in the incorrect order.

Question 57Tier/Group 2/2 K/A Importance Rating - RO 3.1 SRO 3.2Knowledge of bus power supplies to the following: PZR heatersReference(s) - Sim/Plant design, System DescriptionProposed References to be provided to applicants during examination - NoneLearning Objective - PZR 005Question Source - NEW Question Cognitive Level - F 10 CFR Part 55 Content - 41.7 Comments -

120

ILC-11-2 NRC Exam

58. 015 K6.01 001Given the following plant conditions: - Plant is at 100% RTP.The following alarms are subsequently received: - APP-005-A3, PR DROP ROD

- APP-005-C3, PR CHANNEL DEV

- APP-005-F3, PR UPPER CH HI FLUX DEV / AUTO DEFEAT - It has been determined that N-44 Power Range Detector A failed LOWWhich ONE (1) of the following completes the statement below?The NI-44C, Delta Flux Meter, will indicate pegged (1) and the Rod ControlSelector Switch is __(2)__ to be selected to the MANUAL (M) position.(1) HIGH(2) NOT required(1) HIGH (2) required(1) LOW(2) NOT required(1) LOW (2) required A.B.C.D.The correct answer is CDetector A is the upper detector for the power ranges. The failure of the detector lowwill cause the % power indication on N-44 to deflect to approximately half of the actualpower level, since the upper and lower detectors combine through a summator tocreate the overall % power output on the NI drawer. The delta flux meter is driven fromthe QTop - QBottom = Delta flux signal. The QTop signal has been lost and will drivethe output of the delta flux circuit negative, and thus indicate pegged low. APP-005-F3,PR UPPER CH HI FLUX DEV will be received and the Misc Drawer will indicate that anupper section deviation has occurred. EC67518 removed the power mismatch circuitry associated with N-44 in October 2008. In the past a failure of N-44 would require the operator to place the rods in manual tostop rod motion.

121

ILC-11-2 NRC Exam Question 58Tier/Group 2/2 K/A Importance Rating - RO 2.9 SRO 3.2Knowledge of the effect of a loss or malfunction on the following will have on the NIS:Sensors, detectors, and indicatorsReference(s) - Sim/Plant design, System Description, OWP-011, APP-005, FMP-009Proposed References to be provided to applicants during examination - NoneLearning Objective - NIS SD-010-010Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.7 / 45.7 Comments - MAB Comments:"D" is not plausible. The interplay between the first and second half does not makesense. If the lower section fails low, then all (or most) power would be indicated in thetop. Therefore making the delta high. Even if an applicant has a misconception thatthe delta was an absolute value, the number would still be high, not low."A" also has minimal credibility.The alarm in question should be referred to by its official designation and name as youhave on other questions. What is the official designation for the Section DeviationAlarm?Revised the stem of question to include the expected APP-005 alarms withofficial designations. Revised the ac tual question. No longer asking thedesignation of the alarm. The question now asks the expected Delta Flux MeterAND N-42, Power Range A Percent Full Power indications.

122

ILC-11-2 NRC Exam

59. 016 K3.09 001Given the following plant conditions: - The plant is in Mode 3 with GP-007, Plant Cooldown from Hot Shutdown to ColdShutdown, in progress. - RCS is at 510°F and 1150 psig. - The PZR PRESS / HI STM LINE DP switch has failed to block the HI STM LINE DPsignal.Which ONE(1) of the following completes the statement below?If the cooldown continues, the highest S/G pressure at which a HI STEAM LINE DPSafety Injection will be received is psig.685 614 585 485 A.B.C.D.The correct answer is D.A. Incorrect - 685 psig is 100 psig ABOVE the steam header pressure electronicallylimited minimum value of 585 psig. Candidate would have to think that the setpointwas line minus header instead of header minus line.B. Incorrect - 614 psig is the low steam line pressure setpoint in the high steam lineflow logic.C. Incorrect - 585 psig is electronically limited minimum value for the steam header pressure.D. Correct.

123

ILC-11-2 NRC Exam Question 59Tier/Group 2/2 K/A Importance Rating - RO 3.5 SRO 3.7Knowledge of the effect that a loss or malfunction of the NNIS will have on thefollowing: ESFASReference(s) - Sim/Plant design, System Description, Logic DiagramsProposed References to be provided to applicants during examination - NoneLearning Objective - ESF 004Question Source - BANK (Not used on an NRC Exam form 2004 to present.)

Question Cognitive Level - H 10 CFR Part 55 Content - 41.7 / 45.6 Comments - MAB Comments:

"A" and "C" are not plausible. We are evaluating high dP betweensteam lines. Therefore, if the same failures, whether it be high or low, occur on eachsteam line, then how does that impact differences between the steam lines?At RNP, high steam line D/P is calculated by subtracting steam line pressurefrom the steam header pressure (ie. Pheader - P line). This SI signal only requiresone S/G to have the condition, which is a concept that is often missed bycandidates.

124

ILC-11-2 NRC Exam

60. 028 A4.02 001Given the following plant conditions: - A LOCA has just occurred and CV Pressure indicates 15 psig on ERFIS.Which ONE(1) of the following completes the statement below?In addition to ERFIS and AR-100C, CV Conditions Recorder, CV Pr essure is indicatedin the control room by (1)

Wide Range Indicators on the RTGB and (2)

Extended Range indicator(s) on the PAM Panel.(1) three(2) one(1) six(2) two(1) six(2) one(1) three (2) two A.B.C.D.The correct answer is B. A. Incorrect - There are six pressure indicators enclosed in three edge meter panels. Two indications per edge meter panel. There is only one narrow range indicator on theRTGB, however, there are two extended range indicators on the PAM Panel.B. Correct C. Incorrect - The first part is correct. There is only one narrow range indicator on theRTGB, however, there are two extended range indicators on the PAM Panel.D. Incorrect. There are six pressure indicators enclosed in three edge meter panels. Two indications per edge meter panel. The second part of distractor is correct.

125

ILC-11-2 NRC Exam Question 60Tier/Group 2/2 K/A Importance Rating - RO 3.7 SRO 3.9Ability to manually operate and/or monitor in the control room: Location andinterpretation of containment pressure indicationsReference(s) - Sim/Plant design, System DescriptionProposed References to be provided to applicants during examination - NoneLearning Objective - CV 005Question Source - NEW Question Cognitive Level - F 10 CFR Part 55 Content - 41.7 / 45.5 to 45.8 Comments -

126

ILC-11-2 NRC Exam

61. 041 G2.4.11 001Given the following plant conditions: - The plant is operating at 100% RTP. - A 20% Secondary Load Rejection has occurred. - Steam dump valves did NOT actuate.Which ONE (1) of the following identifies the sequence of actions required to beperformed IAW AOP-015, Secondary Load Rejection, to operate the steam dumpvalves to reduce RCS Tavg?Place PC-464B, Steam Header Press Controller, in Manual and adjust outputas necessary.Place the Steam Dump Mode Switch to STEAM PRESS and manually adjustoutput as necessary.Place PC-464B, Steam Header Press Controller, in Manual and adjust output toMINIMUM. Place the Steam Dump Mode Selector Switch to STEAM PRESS and manually adjust output as necessary.Place the Steam Dump Mode Switch to RESET, then place the switch to STEAMPRESS and manually adjust output as necessary.

A.B.C.D.The correct answer is C. A. Incorrect - The steam dumps will be operated in Manual. However, Steam DumpMode Selector Switch must be placed in STEAM PRESS before the steam dumps willrespond to a manual signal.B. Incorrect - These actions would cause the steam dumps to open rapidly if a demandsignal was present on PC-464B. To prevent the steam dumps from potentially instantlyopening due to a large demand signal the controller is adjusted to MINIMUM prior toselecting STEAM PRESS mode.C. Correct. The output on the controller is verified first to be at zero prior to transferringto steam pressure mode. This will prevent the steam dump from instantly opening dueto a large demand signal.D. Incorrect - These actions will not cause the steam dumps to operate since there willbe no output signal on PC-464B. With these actions taken, if the controller had beenplaced in Manual and output adjusted the steam dumps would have operated.

127

ILC-11-2 NRC Exam Question 61Tier/Group 2/2 K/A Importance Rating - RO 4.0 SRO 4.2Steam Dump System (SDS) and Turbine Bypass Control: Knowledge of abnormalcondition procedures.Reference(s) - Sim/Plant design, AOP-015Proposed References to be provided to applicants during examination - NoneLearning Objective - SD 008Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.10 / 43.5 / 45.13 Comments - MAB Comments:"D" does not appear to be plausible. No justification is supplied for its plausibility. Would BYPASS TAVG INTERLOCK ever be used at power with higher RCStemperatures?

Revised "D" to remove "Place the Steam Dump Control Switchmomentarily to Bypass Tavg Interlock."

128

ILC-11-2 NRC Exam

62. 071 K1.06 001Given the following plant conditions: - Plant is in Mode 3. - A release is in progress from "A" Waste Gas Decay Tank. - R-14C, PLANT STACK NOBLE GAS LOW RANGE, FAIL light illuminates.Which ONE (1) of the following completes the statement below?The condition would cause (1) to alarm and RCV-014, Waste Gas ReleaseIsolation, would (2)

.(1) APP-036-E7, RAD MONITOR TROUBLE,(2) remain OPEN(1) APP-036-E7, RAD MONITOR TROUBLE,(2) CLOSE(1) APP-036-D8, PROCESS MONITOR HI RAD,(2) remain OPEN(1) APP-036-D8, PROCESS MONITOR HI RAD, (2) CLOSE A.B.C.D.The correct answer is B.A. Incorrect. A FAIL signal for R-14C will send a signal to automatically close RCV-014to terminate the release. The FAIL light for R-18, R-11 and R-12 will not causeautomatic actions to secure releases via their applicable paths.B. Correct.

C. Incorrect. No high radiation condition exists, therefore the HI RAD alarm would notbe illuminated. This alarm could be received from temporary spikes or malfunctions,which is why the alarm is verified in APP-036 action steps. The FAIL light for R-18,R-11 and R-12 will not cause automatic actions to secure releases via their applicable

paths.D. Incorrect - No high radiation condition exists, therefore the HI RAD alarm would notbe illuminated. This alarm could be received from temporary spikes or malfunctions,which is why the alarm is verified in APP-036 action steps. Second half of distractor iscorrect.

129

ILC-11-2 NRC Exam Question 62Tier/Group 2/2 K/A Importance Rating - RO 3.1 SRO 3.1Knowledge of the physical connections and/or cause-effect relationships between theWaste Gas Disposal System and the following systems: ARM and PRM systemsReference(s) - Sim/Plant design, APP-036Proposed References to be provided to applicants during examination - NoneLearning Objective - RMS 009Question Source - BANK (Has not been used on NRC Exam from 2004 to present.)Question Cognitive Level - F 10 CFR Part 55 Content - 41.2 TO 41.9 / 45.7 TO 45.8 Comments -

130

ILC-11-2 NRC Exam

63. 072 K5.01 001Given the following plant conditions: - R-4, Charging Pump Room, is in alarm and has been validated. - All non-essential personnel have been evacuated from the Charging Pump Room. - The reason for the alarm is unknown.Which ONE(1) of the following completes the statement below?

R-4, Charging Pump Room, Area Radiation Monitor measures (1) and the NEXT required action to be performed IAW AOP-005, Radiation Monitoring System, is to (2)

. (1) both gamma and beta(2) align the Auxiliary Building Exhaust through the Charcoal Filter Unit(1) gamma ONLY(2) align the Auxiliary Building Exhaust through the Charcoal Filter Unit(1) both gamma and beta(2) inspect the room for system leakage(1) gamma ONLY (2) inspect the room for system leakage A.B.C.D.The correct answer is D.A. Incorrect - R-4 utilizes a detector that is a halogen quenched GM tube to measuregamma fields. The tube is placed in a phenolic tube holder, which is used as a betashield. If leakage is identified in the Charging Pump Room then the Charcoal FilterUnit will be aligned.B. Incorrect - The first part of the distractor is correct. If leakage is identified in theCharging Pump Room then the Charcoal Filter Unit will be aligned.C. Incorrect - R-4 utilizes a detector that is a halogen quenched GM tube to measuregamma fields. The tube is placed in a phenolic tube holder, which is used as a betashield. The second part of the distractor is correct.D. Correct. A leak must be identified in the Charging Pump Room prior to aligning theAuxiliary Building Charoal Filter Unit.

131

ILC-11-2 NRC Exam Question 63Tier/Group 2/2 K/A Importance Rating - RO 2.7 SRO 3.0Knowledge of the operational implications of the following concepts as they apply to theARM system: Radiation theory, including sources, types, units, and effectsReference(s) - Sim/Plant design, System Description, AOP-005Proposed References to be provided to applicants during examination - NoneLearning Objective - RMS 002 Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.6 / 45.4 Comments - MAB Comments: Why is the second part of the answer choices included? Just with part (1) alone, youhave provided 4 unique answer choices, therefore none of part (2) is needed to arriveat the correct answer. Only information that is needed to make that answer choiceunique should be included. Extra information only acts to lower the credibility of thedistracters by providing additional ways to disqualify that distractor. Knowledge of theKA must be required to arrive at the correct answer in order to meet the KA. In thiscase, all I need to know is what is detected and how does the instrument display it. Operational implications needs to be tested to meet the KA. Revised the question to ask what types of radiation R-4 measures and therequired action in AOP-005 for a valid R-4 alarm. Revised stem of the question tosupport the required answers.Bolded the word "NEXT" in the stem of the question. Resulted from validationcomments.

132

ILC-11-2 NRC Exam

64. 079 K4.01 001Given the following plant conditions: - The plant is operating at 100% RTP. - A loss of Instrument Air has occurred with pressure currently at 75 psig. - The crew is implementing AOP-017, Loss of Instrument Air.Which ONE(1) of the following identifies the preferred flowpath when Station Air isrequired to be cross-connected with Instrument Air IAW AOP-017?Flow is from the Station Air Compressor -----

>Station Air coalescing filter -----

> Instrument Air Headerbypass the Station Air coalescing filter -----

> Instrument Air Dryers A/B -----

>Instrument Air HeaderStation Air coalescing filter -----

> Instrument Air Dryers A/B -----

> Instrument AirHeaderbypass the Station Air coalescing filter -----

> Instrument Air Header A.B.C.D.The correct answer is A.A. CorrectB. Incorrect - AOP-017 does give an option to bypass the coalescing filter if the inletand/or outlet to the filter cannot be opened. This is not preferred since SA has high oiland moisture content. Normal instrument air flow goes through the air dryers. Aflowpath does not exist for SA to go through the air dryers. In AOP-017, an option doesexist to bypass the IA dryers if necessary to provide IA from the IA compressors.C. Incorrect - A flowpath does not exist for SA to go through the air dryers. Normalinstrument air flow does go through air dryers to remove moisture.D. Incorrect - This flowpath is an option if the inlet and/or outlet to the filter cannot beopened. This is not preferred since SA has high oil and moisture content.

133

ILC-11-2 NRC Exam Question 64Tier/Group 2/2 K/A Importance Rating - RO 2.9 SRO 3.2Knowledge of SAS design feature(s) and/or interlock(s) which provide for the following:Cross-connect with IASReference(s) - Sim/Plant design, System Description, AOP-017Proposed References to be provided to applicants during examination - NoneLearning Objective - AIR 009Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.7 Comments -

134

ILC-11-2 NRC Exam

65. 086 A1.05 001Given the following plant conditions: - During clearance restoration on a drained section of Fire Water piping an isolationvalve is opened too quickly and Fire Water pressure drops to 83 psig.Based on the conditions given, which ONE (1) of the following identifies the impact onthe Fire Water Pumps?MDFP - Motor Driven Fire PumpEDFP - Engine Driven Fire PumpMDFP will start immediately AND the EDFP will start following a 2 sec. time delayMDFP will start following a 2 sec. time delay and the EDFP will start immediatelyMDFP AND EDFP will both start following a 2 sec. time delayMDFP AND EDFP will both start immediately A.B.C.D.The correct answer is A.A. Correct.A. Incorrect - The MDFP will start immediately and the EDFP will start following a 2 sec.time delay. The candidate may feel the time delay is warranted on the MDFP to minimze excessive starting currents on the electrical bus.C. Incorrect. Only the EDFP has a 2 sec. time delay. Candidate may think both pumpshave a time delay to prevent spurious starting of either pump from pressure spikes.D. Incorrect. Candidate may not think a time delay is prudent for fire pumps and thinkthey both start immediately.

135

ILC-11-2 NRC Exam Question 65Tier/Group 2/2 K/A Importance Rating - RO 2.9 SRO 3.1Ability to predict and/or monitor changes in parameters (to prevent exceeding designlimits) associated with Fire Protection System operating the controls including: FPSlineupsReference(s) - Sim/Plant design, System Description, OST-603Proposed References to be provided to applicants during examination - NoneLearning Objective - FPW 006 Question Source - NEW Question Cognitive Level - F 10 CFR Part 55 Content - 41.5 / 45.5 Comments - MAB Comments: The supporting documentation suggests that the MDFP may not start until 95 or 96psig. The documentation suggests that the MDFP could start anywhere between 95and 105 psig. Does this mean that it is possible that someone could argue that "A" isan alternate correct answer?"C" is not plausible. I am having trouble believing that someone would think that anengine would be started before an electrical motor would be used.Changed the stem of the question to have the fire water pressure drop to 83 psig. Question tests the knowledge of the starting sequence for the various fire waterpumps associated with a time delay.

136

ILC-11-2 NRC Exam

66. G2.1.15 001Which ONE (1) of the following statements identifies the administrative requirements ofStanding Instructions IAW OPS-NGGC-1000, Fleet Conduct of Operations?A member of plant management is required to be listed as the Closure Contact.Standing Instructions shall NOT be used to communicate emergency technicalspecification changes that have NOT been formally issued.All active Standing Instructions issued since last standing watch must be reviewed.Standing Instructions for Operational Issues are NOT required to have an expiration date.A.B.C.D.The correct answer is C.A. Incorrect. The Master Standing Instruction Book - Control Room is required even ifa database has been created.B. Incorrect - IAW OPS-NGGC-1000, Standing Instructions may be utilized tocommunicate emergency tecnical specification changes that have not been formallyissued.C. Correct. Only have to review the SIs that were approved since you last stood watch. Periodically review all SIs.D. Incorrect. Operational Issues SIs have a maximum life of 92 days. SIs used foritems to inform the shift of procedural changes have a maximum life of 35 days.

137

ILC-11-2 NRC Exam Question 66Tier 3 K/A Importance Rating - RO 2.7 SRO 3.4Knowledge of administrative requirements for temporary management directives, suchas standing orders, night orders, Operations memos, etc.Reference(s) - Sim/Plant design, OPS-NGGC-1000Proposed References to be provided to applicants during examination - NoneLearning Objective - Admin Self StudyQuestion Source - NEW Question Cognitive Level - F 10 CFR Part 55 Content - 41.10 / 45.12 Comments - MAB Comments: OPS-NGGC-1000, Section 9.17.5.1 (f) states that for site-specific standing instructionsmay use a database OR Attachment 8 (which could be placed in a book). The questionappears to pertain to site-specific standing instructions - therefore, could "A" be analternate correct answer? Is there a procedure contradiction here? Does this warrant aprocedure change request? I would think that most standing instructions would be sitespecific; therefore (f) would be the applicable section to follow.

In all cases, a Master Standing Instruction Book has to be maintained in the control room. Thisrequirements ensures that all Standing Instructions are captured should theDatabase become corrupted or "crash." "B" is not plausible. I understand what you have used for plausibility justification, but it still does not seem credible that someone could pull a procedure off the shelf and begin to use it - not knowing that it has been altered by a standing order. It is only logical to believe that the procedure itself must be changed to ensure that a task is performedcorrectly. Revised "B" to "Standing Instructions shall not be used to communicateemergency technical specification changes that have not been formally issued."

138

ILC-11-2 NRC Exam

67. G2.1.17 001Given the following plant conditions: - A plant event is in progress. - The plant alarms are out-of-service. - A Site Area Emergency has been declared.Based on the conditions above, which ONE (1) of the following completes thestatements below?IAW OMM-001-4, Communications, the SM (1) required to communicate through the CRS to have an operator to place the VLC Switch to the emergencyposition. IAW OMM-001-7,Notifications, the emergency announcements should be repeated (2) times.(1) is NOT(2) TWO(1) is NOT(2) THREE(1) is(2) TWO(1) is (2) THREE A.B.C.D.The correct answer is B.A. Incorrect - The Emergency Preparedness procedures require that plantannouncements for declarations be made twice. However, OMM-001-7 requires that the announcements be made three times if the alarms are OOS.B. Correct.

C. Incorrect - An acknowledgement from the current Operations shift personnel wouldensure that they received and understood the announcement. This is part of normalthree-way communication. However, this acknowledgement is not procedurallyrequired.D. Incorrect - An acknowledgement from both the TSC and EOF would ensure that theyreceived and understood the announcement. This is part of normal three-waycommunication. However, this acknowledgement is not procedurally required.

139

ILC-11-2 NRC Exam Question 67Tier 3 K/A Importance Rating - RO 3.9 SRO 4.0Ability to make accurate, clear, and concise verbal reports.Reference(s) - Sim/Plant design, OMM-001-7Proposed References to be provided to applicants during examination - NoneLearning Objective - Admin Self StudyQuestion Source - BANK (Last used on the 2007 NRC Exam.)Question Cognitive Level - F 10 CFR Part 55 Content - 41.10 / 45.12 / 45.13 Comments - MAB Comments:"C" is not plausible. This is a plant announcement - an announcement to the entireplant. When an announcement is made to the entire plant, would it be credible thateveryone be required to respond?

Revised "C" to state "until acknowledged bycurrent Operations shift personnel."

"D" also is not plausible. Nothing in the stem even indicates that the TSC and EOFhave been activated. Even if the EOF was activated - it is located off site. Why wouldthere be a requirement for the announcement to be in a continuous do-loop until anoff-site acknowledgement is made for an announcement?

At RNP the TSC and EOFare located within the protected area and can hear plant announcements and arein communication with the control room. The EOF does not have the capabilityto sound alarms and has to contact the control room to sound alarms asnecessary. Therefore, it would be credible to think that they would acknowledgeannouncments if plant alarms are OOS.For a plant announcement, what mechanism exists for three way communications? Three way communications typically is done only one to one or in small groups.

Threeway communication can occur over the phone when the individual acknowledgesthe alarm.I also noted that this question was used on the 2007 NRC exam.

140

ILC-11-2 NRC Exam

68. G2.1.27 001Which ONE (1) of the following completes the statement below?The Inadequate Core Cooling Monitor (ICCM) is designed to monitor for inadequatecore cooling during a

.Large Break LOCASmall Break LOCALoss of All AC PowerLoss of Heat Sink Accident A.B.C.D.The correct answer is B.A. Incorrect - The ICCM is capable of surviving a large-break LOCA transient so that itcan be used for post-accident monitoring and recovery. However, instrumentationassociated with the Reactor Protection System identifies a large-break LOCA andinitiated emergency core cooling systems before the control room operator can respondto the ICCM.B. CorrectC. Incorrect - Parameters are utilized from the ICCM during the mitigation of a Loss ofall AC. The ICCM is powered from DC supplied Instrument Buses and will remainenergized for some time following a loss of all AC Power.D. Incorrect. Parameters are utilized from the ICCM during the mitigation of a Loss ofHeat Sink, such as CETC temperatures. However, ICCM is designed primarily for aSmall Break LOCA.

141

ILC-11-2 NRC Exam Question 68Tier 3 K/A Importance Rating - RO 3.7 SRO 3.9Knowledge of system purpose and/or function.Reference(s) - Sim/Plant design, System DescriptionProposed References to be provided to applicants during examination - NoneLearning Objective - ICCM 001Question Source - BANK (Not used on an NRC Exam from 2004 to present.)Question Cognitive Level - F 10 CFR Part 55 Content - 41.7 Comments - MAB Comments: The wording of this question does not sound right to me. The design function of theICCM is a SB LOCA? I think what you are trying to test is that the ICCM is designed tomonitor for inadequate core cooling during a SB LOCA. I think some modification tothe wording of the question and/or answer choices is necessary. Revised the wording to ask " The ICCM is designed to monitor for inadequatecore cooling during a

."C" is not plausible. A steam line break will cool the core - cooling will not beinadequate. Changed "C" to Loss of All AC Power. The ICCM will remainenergized via the station batteries during a loss of all AC.

142

ILC-11-2 NRC Exam

69. G2.2.6 001Which ONE (1) of the following statements applies to the temporary procedure changeprocess IAW PRO-NGGC-0204, PROCEDURE REVIEW AND APPROVAL?PNSC - Plant Nuclear Safety CommitteeThe expiration date of the temporary change shall not exceed 21 days from theapproval date.Two SROs, one of which is a PNSC member, must approve a temporary change ifthe revision is a change of intent.Two SROs, none of which are required to be a PNSC member, must approve atemporary change if the revision is a change of intent.The expiration date of the temporary change shall not exceed four months from theinterim approval date.

A.B.C.D.The correct answer is A. A. CorrectB. Incorrect - A temporary change has to be approved by Management personnel, but itdoes NOT require the Procedure Owner to approve it before use by the shift operators.C. Incorrect - Temporary Procedure Change Interim Approver at RNP are required tobe a member of management AND the Shift Manager or designee with a SRO license. Since two personnel are required for approval of an temporary change the candidatemay think that both must hold an SRO license. A temporary procedure change is notallowed for a change of intent. Candidate may think that a change of intent is a specialtype of temporary procedure change that requires two SROs. D. Incorrect - Four months is the expiration date for temporary procedure revisions forALL other Progress Energy sites.

143

ILC-11-2 NRC Exam Question 69Tier 3 K/A Importance Rating - RO 3.0 SRO 3.6Knowledge of the process for making changes to procedures.Reference(s) - Sim/Plant design, PRO-NGGC-0204Proposed References to be provided to applicants during examination - NoneLearning Objective - Admin Self StudyQuestion Source - BANK (Used on the 2008 NRC Exam.)Question Cognitive Level - F 10 CFR Part 55 Content - 41.10 / 43.3 / 45.13 Comments - Discussed with P. Capehart on 6/15/11:

Discussed concern that RNPdoes not utilize temporary procedure changes. All procedure changes are performedutilizing the normal process and procedure writers are called out to make necessarychanges if conditions warrant. It was agreed to prepare a question to the K/A and ifdifficulty in preparing plausible distracters becomes evident then this K/A will be re-addressed.MAB Comments:What is PI-2089 at Robinson?

Removed from question stem. This was a made up instrument."B" is not plausible. The procedure in question is an AOP. Therefore, the plant is in anabnormal condition - potentially on a backshift. Is it credib le to think that the procedureowner would be required to approve the temporary procedure change?

"C" is not plausible for similar reasons. How long does the normal procedure changeprocess take? The plant is in an abnormal condition. Is it reasonable that a typo wouldprevent the crew from taking care of the plant?Removed AOP from the stem of the question. Question now simply asks whichof the following statements applies to the temporary proce dure change processIAW PRO-NGGC-0204.

144

ILC-11-2 NRC Exam

70. G2.2.7 001Operations has been scheduled to perform a new Special Test that has beendesignated as an Infrequently Performed Test or Evolution IAW OPS-NGGC-1315, Conduct of Infrequently Performed Tests or Evolutions (IPTE).Which ONE(1) of the following completes the statement below?IAW OPS-NGGC-1315, the

___

is required to designate the IPTE Manager.Shift ManagerManager - Shift OperationsOperations Manager Plant General Manager A.B.C.D.The correct answer is D.A. Incorrect - The Shift Manager will be involved in the IPTE and will most likely contactthe PGM to determine the IPTE manager. The PGM will desingate the IPTE Manager.B. Incorrect - The Manager - Shift Operations could be involved with requesting anIPTE Manager and could also be designated as the IPTE manager. However, thePGM is required to designate the IPTE Manager.C. Incorrect - The Operations Manager could be involved with requesting an IPTEManager and could also be designated as the IPTE manager. However, the PGM isrequired to designate the IPTE ManagerD. Correct.

145

ILC-11-2 NRC Exam Question 70Tier 3 K/A Importance Rating - RO 2.9 SRO 3.6Knowledge of the process for conducting special or infrequent tests.Reference(s) - Sim/Plant design, OPS-NGGC-1315Proposed References to be provided to applicants during examination - NoneLearning Objective - Admin Self StudyQuestion Source - NEW Question Cognitive Level - F 10 CFR Part 55 Content - 41.10 / 43.3 / 45.13 Comments - MAB Comments: This type of information is usually tested on the SRO portion of the exam. Is this ROrequired knowledge at Robinson? Is there an RO learning objective for thisinformation? If this question appears in its current form in the final submittal, then it willbe considered as RO knowledge at Robinson.

RO Knowledge.No comments on the material aspects of the question.Question revised to only ask who is required to designate the IPTE Manager. Result from validation comments.

146

ILC-11-2 NRC Exam

71. G2.3.13 001Given the following plant conditions: - RCS cooldown is in progress IAW GP-007, Plant Cooldown from Hot Shutdown to Cold Shutdown. - The RCS Filter radiation levels are 1100 mrem/hr at 30 cm from the filter housing. - You have been assigned by the WCC SRO to hang a clearance on the filter for replacement.

Which ONE (1) of the following identifies The radiation area is required to be classified as a (1) and the Independent /Concurrent Verification (2) be waived IAW OPS-NGGC-1303, IndependentVerification.

(1) Locked High Radiation Area(2) can(1) High Radiation Area(2) can(1) Locked High Radiation Area (2) cannot(1) High Radiation Area (2) cannot A.B.C.D.The correct answer is A. A. Correct. Reference AP-031. A LHRA is in excess of 1000 mrem in one hour at 30cm from the source. IAW OPS-NGGC-1303, IV can be waived if excessive radiationexposures would result to conduct the IV. As a guideline, an exposure of greater than10 mrem would be considered excessive. If the IV took 1 minute the person performing the IV could received approximately 18 mrem.B. Incorrect. HRA is >100 mR in 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. The second part of the distractor is correct. See discussion in "A" above.C. Incorrect. Classification correct. IAW OPS-NGGC-1303, IV can be waived ifexcessive radiation exposures would result to conduct the IV. As a guideline, an exposure of greater than 10 mrem would be considered excessive. If the IV took 1minute the person performing the IV could received approximately 18 mrem.D. Incorrect. Both parts are incorrect. See discussions above. These areas typicallynot LHRAs, but HRAs.

147

ILC-11-2 NRC Exam Question 71Tier 3 K/A Importance Rating - RO 3.4 SRO 3.7Knowledge of radiological safety procedures pertaining to licensed operator duties,such as response to radiation monitor alarms, containment entry requirements, fuelhandling responsibilities, access to locked high-radiation areas, aligning filters, etc.Reference(s) - Sim/Plant design, HPS-NGGC-0003, AP-031.Proposed References to be provided to applicants during examination - NoneLearning Objective - Admin Self Study, Rad. Work Training Question Source - ILC-09 NRC EXAM Question Cognitive Level - F 10 CFR Part 55 Content -

41.12 / 43.4 / 45.9 / 45.10Comments - MAB Comments:Nuclear Shift Manager does not appear to contain plausibility for a LHRA entry approval. A normal evolution is occurring and the issue is with high radiation levels. Suggest replacing the approval part. What about equipment verifications in a highdose area - are their alternate methods that can be used to maintain does ALARA? Question revised as recommended. Question no longer asks who must approveentry. Question now ask the candidate to classify the area and determine if IV/CVcan be waived due to the dose concerns.Question was on the ILC-09 NRC Exam.

Question revised. No longer matches thequestion from ILC-09 NRC Exam.How was this question selected? Have the licensee walk through in detail, theselection process used for this question.

Random.org is more than one questionfound that matches the K/A.NUREG-1021, ES-401, Page 8 of 33, states, "If the bank contains more than onequestion that fits a specific KA statement, randomly select from among the availablequestions unless there is an appropriate basis for selecting a specific question (e.g.,higher cognitive level, better discrimination validity, more operationally oriented, orsite-specific priority)."

148

ILC-11-2 NRC Exam

72. G2.3.4 001Which ONE (1) of the following are the correct values for the 10CFR20 Federal AdultOccupational Dose Limits?

Skin Lens of Eye 50 rem/yr 5 rem/yr 50 rem/yr 15 rem/yr 15 rem/yr 5 rem/yr 15 rem/yr 15 rem/yr A.B.C.D.The correct answer is B.A. Incorrect - Plausible since the lens of eye limit listed is lowest value, which isexpected. B. Correct C. Incorrect - Plausible since the lens of eye limit listed is the lowest value, which isexpected. D. Incorrect - Plausible because SKIn and Extremities have the same limit of 50 rem/yr. Candidate may confuse this fact and think that Skin and Lens of Eye are the samelimit.

149

ILC-11-2 NRC Exam Question 72Tier 3 K/A Importance Rating - RO 3.2 SRO 3.7Knowledge of radiation exposure limits under normal or emergency conditions.Reference(s) - Sim/Plant design, DOS-NGGC-0004Proposed References to be provided to applicants during examination - NoneLearning Objective - Admin Self Study, Rad. Worker TrainingQuestion Source - BANK (Not used an NRC Exam from 2004 to present.)Question Cognitive Level - F 10 CFR Part 55 Content - 41.12 / 43.4 / 45.10 Comments - MAB Comments:Why are three columns of information included? Only include information in thedistractors that is needed to make the answer choices unique. In this case you cancompletely delete the first column (Extremities) and you still have 4 unique answer choices. The only purpose the extra information serves is to reduce the plausibility ofdistractors by providing more ways to disqualify the distractors.

Deleted the firstcolumn as recommended.

150

ILC-11-2 NRC Exam

73. G2.4.25 001Which ONE (1) of the following identifies the procedure that provides the IncidentCommander with detailed method of attack strategies for a fire in the MDAFW PumpRoom?AOP-041, Response to Fire EventOMM-002, Fire Protection ManualOMM-003, Fire Protection Pre-PlansAPP-044, Fire Alarm Response Manual A.B.C.D.The correct answer is C.A. Incorrect - AOP-041 is a relatively new AOP that provides control room direction onhow to address a fire in the plant. However, this procedure does not contain specificattack strategies for specific plant areas.B. Incorrect - This procedure establishes the responsibilities and methods forimplementation of the RNP Fire Protection Program.C. CorrectD. Incorrect - This procedure provides control room responses for Fire Alarm Consolealarms. Does not provide attack strategies for the fire brigade.

Question 73Tier 3 K/A Importance Rating - RO 3.3 SRO 3.7Knowledge of fire protection procedures.Reference(s) - Sim/Plant design, AOP-041, OMM-002, OMM-003, APP-044Proposed References to be provided to applicants during examination - NoneLearning Objective - OMM-003-003Question Source - BANK (Last used on 2004 NRC Exam.) Question Cognitive Level - F 10 CFR Part 55 Content - 41.10 / 43.5 / 45.13 Comments - K/A match because candidate must know that OMM-003 provides theplans and strategies for safe and effective fire suppression by the Unit 2 Fire Brigadeand offsite fire companies. Reviewed and approved by MAB.

151

ILC-11-2 NRC Exam

74. G2.4.39 001Given the following plant conditions: - Plant was at 100% RTP. - At time 1205 a Reactor Trip and several events occurred. - At time 1215 an ALERT is declared by the CR-SEC. - At time 1225 the Emergency Notification Form is completed and approved by the CR-SEC.Which ONE(1) of the following identifies the LATEST time that the initial notification tothe State and County officials is due?

1220 1230 1235 1240 A.B.C.D.The correct answer is B.A. Incorrect. This is the time at which the declaration must be made by the CR-SEC.B. Correct.C. Incorrect. The CR-SEC has 15 minutes to declare the event and then 15 minutesfrom declaration to notify the state and counties. This theoretically gives the CR-SEC 30 minutes to make a notification. However, since the declaration was made at 1215the notification must be made by 1230. This distractor is based on 30 minutes from 1205.D. Incorrect. This distractor is based on 15 minutes incorrectly added to the time theENF form was completed and approved. The notification must be made within 15minutes of the event declaration.

Question 74Tier 3 K/A Importance Rating - RO 3.9 SRO 3.8Knowledge of RO responsibilities in emergency plan implementation.Reference(s) - Sim/Plant design, EPNOT-01, EPCLA-01Proposed References to be provided to applicants during examination - NoneLearning Objective - Emergency Communicator QualificationQuestion Source - BANK (Used on the 2007 NRC Exam.)Question Cognitive Level - F 10 CFR Part 55 Content - 41.10 / 45.11 Comments -

152

ILC-11-2 NRC Exam

75. G2.4.9 001Given the following plant conditions: - Plant cooldown is in progress. RCS Temperature is at 290°F. - Excessive leakage has been identified in "C" RCP Bay. - "A" RHR pump is providing decay heat removal. - RCS letdown has been isolated.

- Two charging pumps are running at maximum speed. - PZR level is 12% and lowering.

- RCS subcooling is 40°F.Which ONE (1) of the following completes the statement below?IAW AOP-033, Shutdown LOCA, the NEXT step required to be performed formitigation strategy is to ......check SI Pump Suction Line to RWST - ANY REASON TO BELIEVE STEAMBOUND.start the remaining Charging Pump and raise speed to maximum.verify available SI Pump Breakers - RACKED INstop "A" RHR Pump.

A.B.C.D.The correct answer is B.A. Incorrect - If all three charging pumps were running at maximum speed with theindications given then this would be the correct answer.B. Correct - AOP-033, Step 8, has the operator to check all charging pumps running atfull speed if PZR level is lowering and letdown is isolated.C. Incorrect - SI pump breakers are verified racked in once the SI pump suction line toRWST has been verified to not to be steam bound. AOP-016 directs the crew to tripthe reactor and go to PATH-1 if PZR level cannot be maintained with two chargingpumps at maximum speed and letdown isolated. This makes starting a SI pump aplausible distractor.D. Incorrect - "A" RHR pump would be stopped if PZR level is less than 10% or RCSsubcooling is less than 35°F. These conditions are not met, however, PZR level iscontinuing to lower.

153

ILC-11-2 NRC Exam Question 75Tier 3 K/A Importance Rating - RO 3.8 SRO 4.2Knowledge of low power/shutdown implications in accident (e.g., loss of coolantaccident or loss of residual heat removal) mitigation strategies.Reference(s) - Sim/Plant design, AOP-033Proposed References to be provided to applicants during examination - NoneLearning Objective - AOP-033-004Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.10 / 43.5 / 45.13 Comments - MAB Comment:

How would the operators know that there were no indications that theleak was in the RHR system? No sump/rad alarms in aux bld would not tell the entirestory? I just want to ensure that the conditions provided are operationally valid to placethem in the right procedure location to support the correct answer.Removed the statements that a LOCA had occurred and CV pressure elevatedfrom the stem. Revise bullet to state that "A" RHR pump is providing decay heatremoval vice core cooling. Also removed the statement "There is no indication ofa rupture in the RHR System." Added "Excessive leakage has been identified in"C" RCP Bay" to the stem of the question. This statement means that theleakage would be downstream of the RHR-744s which are located outside the missile barrier.Bolded the word "NEXT" in the stem of the question. Result of validationcomments.

154

ILC-11-2 NRC Exam

76. 038 EG2.4.11 SRO 001Given the following plant conditions: - The plant is operating at 100% RTP. - The crew is implementing AOP-035, S/G Tube Leak, due to an identified tube leakin "B" S/G. - Two charging pumps are running at maximum output and all letdown flowpathshave been isolated. - RO reports that PZR Level is at 22% and continuing to lower in an uncontrolledmanner.Which ONE (1) of the following is the proper procedural progression for the givenconditions?EPP-7, SI TerminationEPP-12, Post-SGTR Cooldown Using BackfillTrip the Reactor --> Manual SI

--> PATH-1 --> PATH-2 --> EPP-12Trip the Reactor

--> Manual SI

--> PATH-1 --> PATH-2 --> EPP-7 --> EPP-12Continue in AOP-035 --> Trip the Reactor and actuate SI when PZR level reaches 10% --> PATH-1 --> PATH-2 --> EPP-12Continue in AOP-035, start the remaining charging pump and raise speed tomaximum and monitor PZR level.

A.B.C.D.The correct answer is A.A. Correct.

B. Incorrect. EPP-7 is not entered for a tube rupture. PATH-2 and EPP-12 will providedirection on when to secure SI pumps and resetting of ECCS components.C. Incorrect. Foldout "A" does contain requir ements to actuate SI if PZR Level cannotbe maintained greater than 10%. AOP-035 does not provide this direction. AOP-035requires that the reactor be tripped if RCS level is lowering uncontrollably with twocharging pumps at maximum speed and letdown isolated.D. Incorrect. This was the correct process up to a few years ago. In the past the thirdcharging pump was started and taken to maximum speed after letdown was isolated. This was removed during a recent revision as a prudent action to trip the reactor withonly two charging pumps running at maximum speed and letdown isolated.

155

ILC-11-2 NRC Exam Question 76Tier/Group 1/1 K/A Importance Rating - RO 4.0 SRO 4.2Steam Generator Tube Rupture: Knowledge of abnormal condition procedures.Reference(s) - Sim/Plant design, AOP-035, PATH-1/2, EPP-12, EPP-7Proposed References to be provided to applicants during examination - NoneLearning Objective - AOP-035-004Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.10 / 43.5 / 45.13Comments - Discussed with P. Capehart on 6/15/11:

Knowledge of abnormalcondition procedures relative to a SGTR. At RNP a SGTR is mitigated utilizing theEOP network procedures. A S/G Tube Leak is mitigated using an AOP. Agreed that"abnormal condition procedures" also included the EOP network proceduresSRO: Assessing plant conditions and then selecting a procedure or section of aprocedure to mitigate, recover, or which to proceed.

156

ILC-11-2 NRC Exam

77. 054 AG2.4.11 SRO 001Given the following plant conditions:Initial Conditions: - The plant is at 100% RTP. - OST-010, Power Range Calorimetric During Power Operation Daily, was performedat 1000 hours0.0116 days <br />0.278 hours <br />0.00165 weeks <br />3.805e-4 months <br />.Current Conditions: - FWUFM declared out of service at 1300 hours0.015 days <br />0.361 hours <br />0.00215 weeks <br />4.9465e-4 months <br />. - A feedwater flow transient has occurred. - HCV-1459, LP Heaters Bypass Valve, is observed to be OPEN with its controlswitch in AUTO. - Main Feedwater Pump suction pressure is currently 375 psig.Which ONE (1) of the following completes the statements below?IAW OMM-001-2, Shift Routines and Operating Practices, Reactor Thermal Power islimited to a maximum of (1)

MWth briefly power excursions.AOP-010, Main Feedwater/Condensate Malfunction, (2) contain steps to reducepower.(1) 2346 MWth(2) does(1) 2339 MWth(2) does(1) 2339 MWth(2) does NOT(1) 2346 MWth (2) does NOT A.B.C.D.

157

ILC-11-2 NRC ExamThe correct answer is A.

A. Correct.B. Incorrect. With HCV-1459 open the feedwater will become cooler due to bypassingthe LP FW Heaters. This will cause reactor power to increase. 2339 is 100% RTPwhen FWUFM is in service. This is the power level that the operators attempt tomaintain. With FWUFM OOS the operators will have to control power to a maximum of2300 MWth when it has been OOS longer than allowed by TRM 3.25. Duringsteady-state operations the 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> average power is required to 2339 MWth or less. Ifa valid calorimetric Power Alarm is received, reactor power is required to be reduced toless than 2339 MWth. The second part of the distractor is correct.C. Incorrect. See "B" above for discussion concerning 2339 MWth. AOP-010 doesdirect the operators to control reactor power to less than 100%. Power will be loweredso that MFP suction pressure is greater than 400 psig. At 400 psig MFP suctionpressure HCV-1459 should automatically open with the control switch in AUTO. In thepast, ~ 6 years ago, directions to control power were added to the AOPs so thatOP-105 would not have to be entered everytime a power reduction was required.D. Incorrect. With HCV-1459 open the feedwater will become cooler due to bypassingthe LP FW Heaters. This will cause reactor power to increase. OMM-001-2 does allowfor power excursions to occur for short periods of time as long as the absoutemaximum RTP of 2346 MWth is not exceeded. (102% of 2300MWth is 2346MWth)AOP-010 does direct the operators to control reactor power to less than 100%. Powerwill be lowered so that MFP suction pressure is greater than 400 psig. At 400 psig MFP suction pressure HCV-1459 should automatically open with the control switch inAUTO. In the past, ~ 6 years ago, directions to control power were added to the AOPsso that OP-105 would not have to be entered everytime a power reduction wasrequired.

158

ILC-11-2 NRC Exam Question 77Tier/Group 1/1 K/A Importance Rating - RO 4.0 SRO 4.2Loss of Main Feedwater (MFW): Knowledge of abnormal condition procedures.Reference(s) - Sim/Plant design, AOP-010, OMM-001-2Proposed References to be provided to applicants during examination - NoneLearning Objective - AOP-010-006Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.10 / 43.5 / 45.13 Comments - SRO: Assessing plant conditions and then selecting a section of a procedure tomitigate, recover, or with which to proceed. Also knowledge of maximum licensedthermal power limitations.RAB Comments:Why is 2385 MWth plausible? What documents refer to 2385 MWth? No documentation was provided to justify its plausibility. (I am assuming 102% of rated?) There may be two acceptable options: (1)To enhance plausibility, consider makingUFMs out of service and iterate on 2346 MWth and 2300 MWth. OR (2) providesupporting documentation for the plausibility of 2385 MWth.

Removed 2385 MWth. Replaced with 2339 and revised the question stem to ask what is the maximumallowed Reactor Thermal Power for short power excursions.Why is OP-105 an incorrect choice? I see no explanation or documentation with thequestion that supports OP-105 being incorrect. Consider iterating on (1) AOP-10contains steps to reduce power. AND (2) AOP-10 does not contain steps to reducepower. Revised as recommended. Question now asked whether or not AOP-010contains steps to reduce power.The last sentence in the analysis of answer choice B does not appear to be correct. Itstates that 2385 MWth is correct - yet the correct answer has 2346 MWth as correct. Typo. 2385 no longer is part of the answers.Knowledge of max licensed power limits is RO knowledge - after all the ROs areoperating the plant.

Agreed.Made "FWUFM out of service." a separate bullet in the stem of question. Alsochanged "allow to increase" to "limited". Comments from exam validation.

159

ILC-11-2 NRC Exam

78. 055 EA2.01 SRO 001Given the following plant conditions: - GP-007, Plant Cooldown From Hot Shutdown to Cold Shutdown is in progress.- RCS temperature is 225°F with RHR Pump "A" in service. - At time 1500 the SUT has failed and both EDGs have tripped.- At time 1520 efforts to restore power are still in progress.Which ONE (1) of the following completes the statement below?

FCV-605 and HCV-758 will fail (1) and the Emergency Action Level required tobe declared IAW the EAL Matrices is a(n)

(2)

. FCV-605, RHR HX BYPASS FLOWHCV-758, RHR HX DISCH FLOW(Reference Provided)(1) SHUT(2) Alert(1) OPEN(2) Alert(1) OPEN(2) Site Area Emergency(1) SHUT (2) Site Area Emergency A.B.C.D.

160

ILC-11-2 NRC ExamThe correct answer is D.A: Incorrect - Both FCV-605 and HCV-758 fail SHUT on loss of IA. A SAE will be declaredsince the plant is still in Mode 4 and power not restored within 15 minutes. Ifcandidate uses the Cold Conditions matrix then the Alert is a plausible answer.B: Incorrect - Both FCV-605 and HCV-758 fail SHUT on loss of IA. A SAE will be declaredsince the plant is still in Mode 4 and power not restored within 15 minutes. If candidate uses the Cold Conditions matrix then the Alert is a plausible answer.C: Incorrect - Both FCV-605 and HCV-758 fail SHUT on loss of IA. Second part of distractor iscorrect.D: Correct -

161

ILC-11-2 NRC Exam Question 78Tier/Group 1/1 K/A Importance Rating - RO 3.4 SRO 3.7Ability to determine or interpret the following as they apply to a Station Blackout:Existing valve positioning on a loss of instrument air system.Reference(s) - Sim/Plant design, AOP-017, Pages 3 and 36; SD-003, RHR, Figure 3.,OMM-022.Proposed References to be provided to applicants during examination - NoneLearning Objective - AOP-017-006 Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 43.5 / 45.13 Comments - SRO: The candidate must have knowledge of administrative procedures that specifyhierarchy, implementation, and/or coordination of plant normal, abnormal, andemergency procedures. OMM-022, Emergency Operating Procedures User's Guide, contains the instructions for the use of Emergency and Abnormal OperatingProcedures.MAB Comments:KA/SRO-only: The KA is not met at the SRO level. EPP-1 is a major EOP as definedin the SRO guidance. RO knowledge can be used to know that EPP-1 does not apply. Knowing failure modes for a valve is RO knowledge.

Removed procedure entryportion of question and replaced with e-plan question.

Could e-plan be used to hit the KA at the SRO level?

Revised the question to havecandidate determine the EAL action level. Revised stem of question to providenecessary information to properly utilize the EAL matrices. Candidate mustrecognize that even though a cooldown to cold shutdown is in progress the plant is still in Mode 4 and the Hot Conditions Matrix applies.How does the question map through the SRO guidance document?

162

ILC-11-2 NRC Exam

79. 058 AA2.03 SRO 001The plant was operating at 100% RTP when the following occurs: - "B" DC Bus has de-energized. - EPP-27, Loss of DC Bus "B", has been entered. - The batteries and the in-service battery charger are determined to be damaged.Which ONE (1) of the following completes the statements below?

OCBs 52/8 AND 52/9 (1)

.Within four hours of the failure the standby battery charger is aligned to energize the bus to nominal voltage. IAW ITS 3.8, Electrical Power Systems, operability of the bus (2) restored.(1) must be locally tripped (2) is NOT(1) must be locally tripped(2) is(1) will trip on Generator Lockout(2) is NOT(1) will trip on Generator Lockout (2) is A.B.C.D.

163

ILC-11-2 NRC ExamThe correct answer is A.

A. Correct. The OCBs must be locally tripped by a maintenance crew. The DC bus isnot operable. In Modes 1 - 4, for a DC Bus to be considered operable the battery andat least one battery charger must be operable. In Modes 5 and 6 a DC Bus isconsidered operable with either the battery OR a battery charger. The ITS section forModes 5 and 6 is titled 3.8.5 DC Sources - Shutdown.B. Incorrect - The first half of answer is correct. The second half is incorrect. The DCbus is not operable. In Modes 1 - 4, for a DC Bus to be considered operable thebattery and at least one battery charger must be operable. In Modes 5 and 6 a DC Busis considered operable with either the battery OR a battery charger. The ITS sectionfor Modes 5 and 6 is titled 3.8.5 DC Sources - Shutdown. Candidate may think thissection applies since the plant is shutdown.

C. Incorrect - The first half is incorrect. A generator lockout will be received but cannotopen the OCBs due to the loss of their control power. The second half of distractor iscorrect. D. Incorrect. The first half is incorrect. A generator lockout will be received but cannotopen the OCBs due to the loss of their control power. The DC bus is not operable. InModes 1 - 4, for a DC Bus to be considered operable the battery and at least onebattery charger must be operable. In Modes 5 and 6 a DC Bus is considered operablewith either the battery OR a battery charger. The ITS section for Modes 5 and 6 istitled 3.8.5 DC Sources - Shutdown. Candidate may think this section applies since theplant is shutdown.

164

ILC-11-2 NRC Exam Question 79Tier/Group 1/1 K/A Importance Rating - RO 3.5 SRO 3.9Ability to determine and interpret the following as they apply to the Loss of DC Power:DC loads lost; impact on ability to operate and monitor plant systemsReference(s) - Sim/Plant design, EPP-4/7, EPP-27, Foldout HProposed References to be provided to applicants during examination - NoneLearning Objective - EPP-27-002Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 43.5 / 45.13 Comments - SRO: Assessing plant conditions and then selecting a procedure or section of aprocedure to mitigate, recover, or with which to proceed. Candidate must alsodemonstrate knowledge of the content of the procedure.MAB Comments:SRO-only: If the plant conditions do not result in an SI, then using RO knowledge, theapplicant would conclude that EPP-7 is not a valid answer choice. Then systemresponse knowledge is the only thing needed to analyze the second part of the answer choices also.

Revised the questin to ask if the OCBs must be locally tripped or wilautomatically trip with a loss of DC Bus "B". Then the candidate is asked todetermine the operability of the bus with a return of the standby battery charger. SRO knowledge is required to determine operability based on knowledge of theITS bases document.How does the question map through the SRO guidance document?

165

ILC-11-2 NRC Exam

80. W/E 04 EG2.4.3 SRO 001The Plant has experienced a LOCA Outside of Containment and the crew hasimplemented PATH-1 and transitioned to EPP-20, LOCA Outside Containment.Which ONE (1) of the following completes the statements below?If ALL of the instruments were operable, (1) are the Reg. Guide 1.97 instrumentsthat would be utilized by EPP-20 to diagnose and mitigate the accident.Given the values listed for each instrument, the conditions of ITS LCO 3.3.3, PostAccident Monitoring (PAM) Instrumentation are (2)

.PI-455, PZR Pressure - 1750 psig and lowering PI-456, PZR Pressure - 1725 psig and lowering PI-457, PZR Pressure - Failed LOWPI-511AA, RCS Wide Range Pressure - 1750 psig and lowering PI-511BA, RCS Wide Range Pressure - 1750 psig and loweringPI-402, RCS Wide Range Pressure - 1725 psig and lowering PI-501, RCS Wide Range Pressure - Failed LOW LT-459, PZR Level Transmitter - 5% and lowering LT-460, PZR Level Transmitter - 5% and lowering LT-461, PZR Level Transmitter - 5% and lowering(REFERENCE PROVIDED)(1) PI-455, 456, 457, 402, 501, LT-459, 460, 461 (NOT PI-511AA, 511BA)(2) NOT met(1) PI-455, 456, 457, 402, 501 (NOT LT-459, 460 , 461, PI-511AA, 511BA)(2) NOT met(1) PI-511AA, 511BA, 402, 501 (NOT LT-459, 460 , 461, PI-455, 456, 457)(2) met(1) PI-511AA, 511BA, LT-459, 460 , 461 (NOT PI-455, 456, 457, 402, 501)(2) met A.B.C.D.

166

ILC-11-2 NRC ExamThe correct answer is C.

A. Incorrect. PI-455,456,457 are not Reg. Guide 1.97 instruments. EPP-20 only usespressure indication only as a means of diagnosis and mitigation for LOCA OutsideContainment. As sections of systems are is olated RCS pressure is monitored to see ifa rising trend is observed. Plausible if the candidate thinks that PI-402 and PI-501,which are Reg Guide 1.97, are the instruments credited for in ITS 3.3.3. The bases for ITS 3.3.3 states that the RCS Pressure (Wide Range) instruments are the indications from the Inadequate Core Cooling Monitor. PI-402 and PI-501 are not part of the ICCMand are therefore not credited in ITS 3.3.3.B. Incorrect. See discussion A above.

C. Correct. PI-511AA, 511BA, 402 and 501 are the only Reg. Guide 1.97 instrumentslisted in the stem of the question. EPP-020 only uses RCS pressure as an indication todetermine if actions to isolate the LOCA have been successful. ITS LCO 3.3.3 requiresthat 2 RCS Wide Range Pressure instruments be operable. The bases for ITS 3.3.3states that the RCS Pressure (Wide Range) instruments are the indications from the Inadequate Core Cooling Monitor. PI-402 and PI-501 are not part of the ICCM and aretherefore not credited in ITS 3.3.3.

D. Incorrect. See distractor A discussion. The second half of the distractor is correct.

Question 80Tier/Group 1/1 K/A Importance Rating - RO 3.7 SRO 3.9LOCA Outside Containment: Ability to identify post-accident instrumentation.Reference(s) - Sim/Plant design, EPP-20, OMM-007, TMM-026, ITS LCO 3.3.3 and bases.

Proposed References to be provided to applicants during examination - ITS 3.3.3Learning Objective -EPP-20-004 Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.6 / 45.4 Comments - K/A match because candidate must know which instruments listed areutilized in EPP-20 and what the requirements are for PAM instrumentation operability. SRO: Candidate must demonstrate knowledge of TS bases that is required to analyzeTS required actions and terminology. The TS bases is the only document that specifiesthat the Wide Range Pressure indication on the ICCM are the ITS 3.3.3 credited RCS

pressure indications.Revise stem of the question to add "If AL L of the instruments were operable". Made the stem of the question two separate questions. Revision based on validation comments

.

167

ILC-11-2 NRC Exam

81. W/E 05 EA2.1 SRO 001Given the following plant conditions: - Plant is operating at 100% RTP. - A seismic event results in a rupture of the common AFW suction line to all AFWpumps coincident with a break in the RCS piping. - Containment pressure reached 4.2 psig and is currently 3.5 psig and lowering. - The crew has transitioned from PATH-1 to FRP-H.1, Response to Loss ofSecondary Heat Sink. - RCS temperature is 360°F and pressure is 275 psig. - S/G conditions:

S/G Level (WR)

Pressure A

42%

800 psig

B 44% 810 psig

C 44%

810 psigWhich ONE (1) of the following completes the statement below?For the conditions given above, a heat sink (1) required. The required proceduralprogression would be to (2)

. (1) is NOT(2) transition to PATH-1, Entry Point A(1) is NOT(2) transition to PATH-1, Entry Point C(1) is(2) remain in FRP-H.1(1) is (2) transition to Supplement I, Aligning RHR System for Core Cooling Mode A.B.C.D.

168

ILC-11-2 NRC ExamThe correct answer is B.

A. Incorrect. The first part is correct. Based on given conditions a LOCA has occurredand a Heat Sink is not required. FRP-H.1 will direct the crew to PATH-1, Enty Point Csince RCS pressure is not greater than any non-faulted steam generator. Entry Point Ais a standard re-entry point to PATH-1 if an incorrect transition is made while inPATH-1.B. Correct.C. Incorrect. Heat sink is not required due to RCS pressure less than all non-faultedS/G pressures. Candidate may not remember this requirement and feel that remaining in FRP-H.1 is higher priority.D. Incorrect. Heat sink is not required due to RCS pressure less than all non-faultedS/G pressures. FRP-H.1 does have a requirement to transition to Supplement I if RCStemperature is less than 350°F. However, this step would not be reached since theLOCA has a higher priority and a heat sink is not required.

169

ILC-11-2 NRC Exam Question 81Tier/Group 1/1 K/A Importance Rating - RO 3.4 SRO 4.4Ability to determine and interpret the following as they apply to the (Loss of SecondaryHeat Sink): Facility conditions and selection of appropriate procedures during abnormaland emergency operations.Reference(s) - Sim/Plant design, FRP-H.1, OMM-022Proposed References to be provided to applicants during examination - NoneLearning Objective - FRP-H.1-001, -004 Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 43.5 / 45.13 SRO: The candidate must assess the given plant conditions during the emergencygiven and then determine if a given section is applicable. This is equivalent to theknowledge of diagnostic steps and decision points in the EOP network that involves transitions to event specific sub-procedures or emergency contingency procedures.MAB Comments:SRO-only: Red path procedure entry is RO knowledge. Mitigatingstrategy is RO knowledge. No SRO level procedure selection is tested in the question. Part of the H.1 strategy is to limit heat input to the RCS - I.E. stop RCPs. Testingdetails of a procedure is not SRO knowledge. Details of a procedure could only beSRO only knowledge if that information is needed to make a procedure selection. Inthis case, stopping an RCP is not a procedure selection - it is a single action that alsohappens to be part of the overall mitigating strategy.

Revised the question to have aseismic event result in a loss of the common AFW suction line, included RCStemperature ad pressure and S/G pressures. Question now asks whether or nota heat sink is required and the procedural progression.How did this question map through the SRO guidance document?

170

ILC-11-2 NRC Exam

82. W/E 015 EG2.1.32 SRO 001Given the following plant conditions: - A seismic event has lead to a LOCA and rupture of SW piping to all HVH units incontainment. - PATH-1 completed to the point of transition to another procedure. - Only one train of CV Spray is operating properly. - The following conditions exist in Containment:

- Containment Pressure is 24 psig and rising. - Containment Sump Level is 385 inches and rising.Which ONE (1) of the following completes the statement below?Based on the current conditions, containment (1) is the highest priority and thebasis for this is (2)

.(1) pressure(2) one train of CV Spray cannot maintain pressure below the containment design pressure(1) pressure(2) due to containment pressure being greater than 10 psig with limitedContainment Cooling(1) sump level (2) potential flooding of critical system s and components needed for future plantrecovery may occur(1) sump level(2) dilution of sump water with SW may potentially cause a return to criticality A.B.C.D.

171

ILC-11-2 NRC ExamThe correct answer is C.

A. Incorrect. As long as one train of CV spray is operating containment pressure will notbecome the top priority until pressure reaches 42 psig. Since above 10 psig, theoperator is sent to a section in the CSFSTs that verifies adequate spray flow.B. Incorrect. As long as one train of CV spray is operating containment pressure will notbecome the top priority until pressure reaches 42 psig. Since above 10 psig, theoperator is sent to a section in the CSFSTs that verifies adequate spray flow.C. Correct.D. Incorrect. The first half of distractor is correct. The basis for FRP-J.2, ContainmentFlooding, does NOT address reactivity as a concern. The rupture of SW will cause adilution of the CV Sump water. The basis for a fire water rupture does address dilutionof sump water in the CV following a LOCA.

172

ILC-11-2 NRC Exam Question 82Tier/Group 1/1 K/A Importance Rating - RO 3.8 SRO 4.0Containment Flooding: Ability to explain and apply system limits and precautions.Reference(s) - Sim/Plant design, CSFST, FRP-J.1 / J.2, FRP-J.2BDProposed References to be provided to applicants during examination - NoneLearning Objective - FRP-J.2-002, --3Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.10 / 43.2 / 45.12SRO: Candidate must know the hierarchy of the Critical Safety Function Status Treeswith respect to containment parameters. Candidate must also know the bases for thisfunctional restoration procedure.MAB Comments:Prior to the STA reporting to the control room, who is responsible for monitoring safetyfunction status trees? Where are these responsibilities defined in administrativeprocedures? At most plants, monitoring of safety functions is RO required knowledge. Does Robinson have an SRO-learning objective for knowing the hierarchy of safetyfunctions?

IAW OMM-022 the CRS is the designated primary SPDS user while theSTA is available to assist.Does Robinson require their operators to have Orange Path FRPs committed tomemory? YESI see no supporting documentation to justify the second part of the answer choices. Before this question can be rated as satisfactory, I will need to see documentation that justifies plausibility and incorrectness of distractors as well as the correctness of theanswer. The basis for the prioritization potentially could be used to justify SRO-only because the guidance document is silent on EOP basis information.

AOP-032 Basesdocument states that a firewater rupture in the CV represents an unanalyzedcondition that would dilute LOCA water before a sump recirc condition. ReviseB(2) so that it will be differenct from A(2) and is based on a misinterpretation ofthe Containment CSF.

173

ILC-11-2 NRC Exam

83. 037 AG2.4.41 SRO 001Given the following plant conditions: - The plant is at 100% RTP. - A tube leak is identified in "C" S/G. - Two charging pumps running at maximum speed are able to control and stabilizePZR level with one 45 gpm letdown orifice in service. - Total RCP Seal Leakoff flow is 7.5 gpm.Which ONE (1) of the following completes the statement below?The required action to address this condition is to (1) and EAL Classification forthis event is (2)

.AOP-035, S/G Tube LeakGP-006-1, Normal Plant Shutdown from Power Operation to Hot Shutdown.(REFERENCE PROVIDED)(1) Shutdown the plant IAW GP-006-1 while concurrently performing AOP-035(2) Unusual Event SU6.1, RCS leakage(1) Shutdown the plant IAW GP-006-1 while concurrently performing AOP-035(2) Alert FA1.1, Any loss or any potential loss of either Fuel Clad or RCS(1) Perform AOP-035, Attachment 1, Local S/G Isolation, on "C" S/G and thencommence a plant shutdown IAW GP-006-1(2) Unusual Event SU6.1, RCS leakage(1) Perform AOP-035, Attachment 1, Local S/G Isolation, on "C" S/G and thencommence a plant shutdown IAW GP-006-1(2) Alert FA1.1, Any loss or any potential loss of either Fuel Clad or RCS A.B.C.D.

174

ILC-11-2 NRC ExamThe correct answer is B.A. Incorrect. The first half of distractor is correct. The EAL classification is incorrectbecause the leak rate given is greater than the capacity of one charging pump. A UEwould be valid up to primary to secondary leak rate of 77 gpm.B. Correct.

C. Incorrect. Isolation of the S/G is not a prerequisite to commencing the plantshutdown. However in some cases the crew may progress through AOP-035 S/Gisolation prior to actually starting the shutdown. The EAL classification is incorrectbecause the leak rate given is greater than the capacity of one charging pump. A UEwould be valid up to primary to secondary leak rate of 77 gpm.D. Incorrect. Isolation of the S/G is not a prerequisite to commencing the plantshutdown. However in some cases the crew may progress through AOP-035 S/Gisolation prior to actually starting the shutdown. The second half of the distractor iscorrect.Leak Rate = 154 gpm - 52.5 gpm = 101.5 gpm154 gpm is two charging pumps at maximum speed.52.5 gpm is 45 gpm letdown orifice plus 7.5 gpm total leakoff flow.

175

ILC-11-2 NRC Exam Question 83Tier/Group 1/2 K/A Importance Rating - RO 2.9 SRO 4.6Steam Generator Tube Leak: Knowledge of the emergency action level thresholds andclassifications.Reference(s) - Sim/Plant design,Proposed References to be provided to applicants during examination - EAL MatrixLearning Objective - AOP-035-004, EAL 004Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.10 / 43.5 / 45.11 Comments - SRO: Candidate must know the proper procedure progression for the given conditionand requires that an EAL classification be properly determined.MAB Comments:Do Robinson procedures actually allow a SG to be isolated prior to shutting down? If aSG is isolated at 100% power, how would the plant respond? My guess is that isolatingthe C SG at 100% power would result in a trip. Therefore, the first part of C and D arenot plausible unless the licensee can provide sufficient justification for plausibility.

Theisolation that is discussed in AOP-035 is local isolation of various paths thatwould not result in a complete isolation of the S/G.Have the licensee show the leakrate calc that results in greater than 77 gpm leakage.Leak Rate = 154 gpm - 52.5 gpm = 101.5 gpm154 gpm is two charging pumps at maximum speed.52.5 gpm is 45 gpm letdown orifice plus 7.5 gpm total leakoff flow.

176

ILC-11-2 NRC Exam

84. 076 AA2.05 SRO 001

- Plant is stable at 100% RTP.

- R-9, Letdown Line Area, radiation monitor had a valid alarm and a reading of15,000 mrem/hr prior to R-9 failing. - RCS samples indicate an RCS Activity of 550

µCi/gm I-131 Dose Equivalent.Which ONE(1) of the following completes the statement below? IAW AOP-005, Radiation Monitoring System, letdown flow (1) and IAW theEmergency Action Level Matrices, an (2) must be declared. (REFERENCE PROVIDED)(1) may remain as-is(2) Unusual Event(1) may remain as-is(2) Alert(1) is required to be reduced(2) Unusual Event(1) is required to be reduced (2) Alert A.B.C.D.

177

ILC-11-2 NRC ExamThe correct answer is D.A. Incorrect. The given letdown flow reading is indicative of one 60 gpm and one 45gpm letdown orifices being in service. AOP-005 requires that letdown be reduced to less than or equal to one letdown orifice valve open. Therefore, letdown flow isrequired to be reduced. The second part is incorrect. The candidate may confuse the 550 µCi/gm I-131 Dose Equivalent reading as being greater than a R-9 reading of 500mrem/hr on the EAL Matrix for an Unusual Event. The activity reading exceeds the 300µCi/gm I-131 Dose Equivalent limit for a loss of the Fuel Cladding Barrier which resultsin meeting the Alert declaration criteria.B. Incorrect. The given letdown flow reading is indicative of one 60 gpm and one 45gpm letdown orifices being in service. AOP-005 requires that letdown be reduced to less than or equal to one letdown orifice valve open. Therefore, letdown flow isrequired to be reduced. The second part of distractor is correct.C. Incorrect - The given letdown flow reading is indicative of one 60 gpm and one 45gpm letdown orifices being in service. AOP-005 requires that letdown be reduced to less than or equal to one letdown orifice valve open. Therefore, letdown flow isrequired to be reduced. The candidate may confuse the 550

µCi/gm I-131 DoseEquivalent reading as being greater than a R-9 reading of 500 mrem/hr on the EALMatrix for an Unusual Event. The activity reading exceeds the 300

µCi/gm I-131 DoseEquivalent limit for a loss of the Fuel Cladding Barrier which results in meeting the Alertdeclaration criteria.D. Correct Question 84Tier/Group 1/2 K/A Importance Rating - RO 2.2 SRO 2.5Ability to determine and interpret the following as they apply to the High ReactorCoolant Activity: CVCS letdown flow rate indicationReference(s) - Sim/Plant design, Proposed References to be provided to applicants during examination - EAL MatrixLearning Objective - AOP-005-004, EAL 004Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 43.5 / 45.13 Comments - SRO: Candidate must make an EAL Declaration, which is an SRO function.

178

ILC-11-2 NRC Exam

85. W/E 09 EA2.1 SRO 001Given the following plant conditions:

Initial Conditions- A loss of off-site power and reactor trip has occurred.- A rupture in the Instrument Air System has resulted in Instrument Air pressurelowering to 20 psig.- The crew performed actions of PATH-1 and has transitioned to EPP-4, ReactorTrip Response.Current Conditions after 15 minutes- CETC temperature is 555°F and rising.- S/G pressure is 1075 psig and rising.Which ONE (1) of the following completes the statements below?

RCS Natural Circulation (1) exist. In the situation described above, detailed steps for restoration of RCS temperaturecontrol will be provided in (2) _

.(1) does(2) AOP-017, Loss of Instrument Air(1) does(2) EPP-4, Reactor Trip Response(1) does NOT(2) EPP-4, Reactor Trip Response(1) does NOT (2) AOP-017, Loss of Instrument Air A.B.C.D.

179

ILC-11-2 NRC ExamCorrect answer is D.

A. Incorrect. NC does not exist with Tave at 555°F and S/G pressures at 1185 psig. Also, nitrogen must be manually aligned to S/G PORVs on a loss of air.B. Incorrect. NC does not exist. AOP-017 provides the procedural direction on how tocontrol S/G pressure and RCS temperature on a loss of instrument air. AOP-017 is aconcurrent use procedure.C. Incorrect. Nitrogen must be manually aligned to S/G PORVs on a loss of Air inaccordance with AOP-017.D. Correct.

180

ILC-11-2 NRC Exam Question 85Tier/Group 1/2 K/A Importance Rating - RO 3.1 SRO 3.8Ability to determine and interpret the following as they apply to the (Natural CirculationOperations): Facility conditions and selection of appropriate procedures during abnormal and emergency operations.Reference(s) - Sim/Plant design, Supplement E, AOP-017, EPP-4, EPP-5Proposed References to be provided to applicants during examination - NoneLearning Objective - EPP-5-004 Question Source - BANK (Last used on 2007 NRC Exam. Format of question modified significantly.)

Question Cognitive Level - H 10 CFR Part 55 Content - 43.5 / 45.13Comments - SRO: Candidate must have knowledge of when to implement attachments withinabnormal / emergency procedures. Candidate must know that the steps to controlRCS temperature using nitrogen aligned to the S/G PORVs is contained in AOP-017and not EPP-4. Procedure selection and knowledge of procedure content versusknowledge of procedure mitigation strategy.MAB Comments:The display of information is a little confusing. The second to last bu llet states that it is15 minutes after the trip. Is the last bullet also 15 minutes after the trip? The secondbullet lists conditions after the trip, yet the third bullet list conditions at the time of trip. To clarify, consider providing sets of conditions at various times - like INITIALCONDITIONS, then CURRENT CONDITIONS.

Revised as recommended.In this case, I believe that procedure selection is being tested in that direction forcontrolling temperature is found in both procedures. The applicant must know morethan just one action and the applicant must know more than the mitigation strategy. Also, more than just entry conditions for the AOP and major EOPs are needed.The KA must be met at the SRO level. The KA requires selection of procedures fornatural circ. How is the procedure selection in the form of temperature controlassociated with natural circ. It seems like the procedure selection may just beassociated with a loss of air. Discuss with licensee to enhance my understanding. AOP-017 is a concurrent use procedure that will be performed along with EPP-4. AOP-017 contains the detailed steps on how to control RCS temperature. EPP-4provides the broad procedure guidance. Bleeding of steam is needed to startnatural circulation.Revised stem of question to read as follows: "In the situation described above,detailed steps for restoration of RCS temperature control will be provided in (2) ." Comments from exam validation.

181

ILC-11-2 NRC Exam

86. 003 A2.03 SRO 001Given the following plant conditions:Initial Conditions: - Plant is operating at 100% RTP. - "A" RCP Motor Upper Thrust Bearing temperature indicates 230°F. - "C" RCP Motor Upper Guide Bearing temperature indicates 205°F.Current Conditions: - RTBs open.

- S/G Levels within normal band. - Pressurizer pressure is normal.Which ONE (1) of the following correctly describes whether RCPs "A" and/or "C" arerequired to be shutdown and whether the conditions of LCO 3.4.5, RCS Loops - Mode3, are met?Both "A" and "C" RCPs are required to be secured.Conditions of LCO 3.4.5 met. "A" RCP is required to be secured. "C" RCP is NOT required to be secured.Conditions of LCO 3.4.5 met.Both "A" and "C" RCPs are required to be secured.Conditions of LCO 3.4.5 NOT met."A" RCP is required to be secured. "C" RCP is NOT required to be secured.Conditions of LCO 3.4.5 NOT met.

A.B.C.D.

182

ILC-11-2 NRC ExamThe correct answer is C.

A. Incorrect. The first part of distractor is correct. Both AOP-018 and AOP-014 statethat the RCP is to be tripped if any RCP motor bearing temperature is greater than200°F. The conditions of LCO 3.4.5 are NOT met. LCO 3.4.5 requires that two RCS loops be operable and one RCS loop shall be in operation as long as the RTBs areopen. Candidate may think that the loop is operable since the S/Gs are greater than16%. However, LCO 3.4.5 bases states that an Operable RCS loop consists of oneOperable RCP and one Operable S/G, which has a minimum water level specified in SR 3.4.5.2 (>= 16%). An RCP is Operable if it is capable of being powered and is ableto provide forced flow if required. Since the B and C RCPs had to be secured due tohigh motor bearing temperatures then they are not available for operation.B. Incorrect. Candidate incorrectly assumed that operation of "C" RCP is allowed atgreater than 200°F Motor Bearing Temperature. The plausibility for this is that the limitfor RCP Pump Bearing temperature is 225°F. See "A" above for remaining justification.C. Correct.

D. Incorrect. Candidate incorrectly assumed that operation of "C" RCP is allowed atgreater than 200°F Motor Bearing Temperature. The plausibility for this is that the limitfor RCP Pump Bearing temperature is 225°F. It is plausible for the candidate to applythe conditions of LCO 3.4.4, RCS Loops - Modes 1 and 2, to this situation and thinkthat 3.4.5 are NOT met. LCO 3.4.4 requires that all three loops be operable and inoperation. Also, the candidate could have simply assumed that LCO 3.4.5 required allthree loops to be Operable.

183

ILC-11-2 NRC Exam Question 86 Tier/Group 2/1 K/A Importance Rating - RO 2.7 SRO 3.1Ability to (a) predict the impacts of the following malfunctions or operations on theRCPS; and (b) based on those predictions, use procedures to correct, control, ormitigate the consequences of those malfunctions or operations: Problems associatedwith RCP motors, including faulty motors and current, and winding and bearingtemperature problemsReference(s) - Sim/Plant design, APP-001, AOP-014, AOP-018, ITS 3.4.4, 3.4.5Proposed References to be provided to applicants during examination - NoneLearning Objective - AOP-014-004 Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content -

41.5 / 43.5 / 45.3 / 45.13Comments -

SRO: Motor parameter being out of spec (above manual trip setpoint) requires RCPs tobe secured, which renders RCS loops inoperable. Procedures, in the form of TechSpecs and AOPs, must be applied to mitigate the conditions. The question wouldqualify as SRO-only because the applicant must apply basis information to determinewhether the loop is operable.Reviewed and approved by MAB.

184

ILC-11-2 NRC Exam

87. 007 A2.05 SRO 001Given the following plant conditions: - Plant is operating at 90% RTP following a refueling outage. - PCV-455C, PZR PORV, has developed excessive seat leakage. - APP-003-B3, PRT HI TEMP AND APP-003-C3, PRT HI PRESS, has alarmed. - PRT Pressure is 6.1 psig and rising.

- RC-536, PZR PORV BLOCK, has been closed to isolate the leakage.Which ONE (1) of the following completes the statements below?IAW ITS LCO 3.4.11 Bases, PCV-455C (1) operable and power (2) requiredto be removed from RC-536.(1) is NOT(2) is NOT(1) is(2) is(1) is(2) is NOT(1) is NOT (2) is A.B.C.D.

185

ILC-11-2 NRC ExamThe correct answer is A.A. Correct.B. Incorrect. ITS LCO 3.4.11 bases states that an Operable PORV is required to becapable of manually opening and closing, and not experiencing excessive seatleakage. This is a recent change to the ITS bases. In the past the bases did notaddress seat leakage. The PORV was only required to be capable of manuallyopening and closing to be considered operable. Candidate may think that since thePORV is leaking and must be isolated that it would be prudent to remove power toprevent inadvertent reinitiation of the PORV seat leakage.C. Incorrect. ITS LCO 3.4.11 bases states that an Operable PORV is required to becapable of manually opening and closing, and not experiencing excessive seatleakage. This is a recent change to the ITS bases. In the past the bases did notaddress seat leakage. The PORV was only required to be capable of manuallyopening and closing to be considered operable. For this distractor the candidateincorrectly determines that the PORV is Operable. Therefore, it would seem logicalthat the PORV block valve would not have power removed.D. Incorrect. The first part of the distractor is correct. The second part of the distractorwould be correct if the PORV was inoperable and not capable of being manuallycycled. In the situation given, the PORV is inoperable solely on the fact that it hasexcessive seat leakage.

Question 87Tier/Group 2/1 K/A Importance Rating - RO 3.2 SRO 3.6Ability to (a) predict the impacts of the following malfunctions or operations on thePRTS; and (b) based on those predictions, use procedures to correct, control, ormitigate the consequences of those malfunctions or operations: Exceeding PRThigh-pressure limitsReference(s) - Sim/Plant design, AOP-019, AOP-016Proposed References to be provided to applicants during examination - NoneLearning Objective - AOP-016-002, AOP-019-002, PZR004Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content -

41.5 / 43.5 / 45.3 / 45.13Comments - K/A match because candidate must determine the correct actions to takefor a condition given that could lead to exceeding the pressure limits of the PRT.SRO: The candidate must demonstrate knowledge of TS bases to determine theoperability of a plant component. Reviewed and approved by MAB.

186

ILC-11-2 NRC Exam

88. 022 G2.4.50 SRO 001Given the following plant conditions: - The plant is operating at 100% RTP. - HVH-1 is under clearance due to bearing damage. - "B" CV Spray Pump has been declared inoperable due to a crack discovered in thecasing. - APP-002-A7, HVH-1/2/3/4 HI VIB, is received and the HIGH VIBRATION white lightis illuminated for HVH-3.Which ONE (1) of the following completes the statements below?To attempt to reset the High Vibration Alarm, APP-002-A7 directs (1)

. Due to local observations the SM has directed that HVH-3 be declared inoperable. The most time limiting ITS LCO required action is that (2)

.(REFERENCE PROVIDED)(1) stopping HVH-3 prior to depressing the vibration switch reset pushbutton(2) the containment spray train AND one containment cooling train be restored toOPERABLE status in 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />(1) resetting the high vibration alarm without stopping HVH-3(2) entry into LCO 3.0.3 be performed immediately(1) stopping HVH-3 prior to depressing the vibration switch reset pushbutton(2) entry into LCO 3.0.3 be performed immediately(1) resetting the high vibration alarm without stopping HVH-3(2) the containment spray train AND one containment cooling train be restored toOPERABLE status in 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> A.B.C.D.

187

ILC-11-2 NRC ExamThe correct answer is B.

A. Incorrect. The fan does not need to be stopped to reset the vibration alarm. Plausible since some components are required to be stopped to reset variousfunctions. Entry into LCO 3.0.3 is required based on the given plant conditions withone train of CV Spray OOS and two trains of CV Cooling OOS.B. Correct.C. Incorrect. The fan does not need to be stopped to reset the vibration alarm. Plausible since some components are required to be stopped to reset variousfunctions. The second half of the distractor is correct. D. Incorrect. The first half of the distractor is correct. Entry into LCO 3.0.3 is requiredbased on the given plant conditions with one train of CV Spray OOS and two trains ofCV Cooling OOS.

188

ILC-11-2 NRC Exam Question 88Tier/Group 2/1 K/A Importance Rating - RO 4.2 SRO 4.0Containment Cooling System (CCS): Ability to verify system alarm setpoints andoperate controls identified in the alarm response manual.Reference(s) - Sim/Plant design, APP-002-A7, ITS 3.6.6Proposed References to be provided to applicants during examination - ITS 3.6.6Learning Objective - CVHVAC 008Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.10 / 43.5 / 45.3 Comments - SRO: Application of Required Actions of Tech Specs.

Entry into ITS 3.0.3 will have theSRO direct controls of the plant to commence a plant shutdown to meet the timelinessof the ITS required actions. MAB Comments:The question tests what "should" be done. Why would it be wrong to stop HVH-3 whenit has high vibes? Would it be possible for me to find an admin procedure that wouldallow an operator to secure a piece of equipment to protect it against further damage? The concern here is having one and only one correct answer. Why would C really bewrong? Suggestion: Reword the first part of the question: To reset the High VibrationAlarm, APP-002-A7 directs: stopping HVH-3 prior to resetting the vibration alarm

vs.resetting the high vibration alarm without stopping HVH-3.

Revised asrecommended.Does a motor calculation error make the "B" CV Pump inoperable? Does it depend onthe specifics of the calculational error? How does your procedures define OOS? Cana piece of equipment simply be off and be considered OOS?

Stem revised to statethat the spray pump is OOS due to a crack discovered in pump casing.Does the High Vibe alarm make HVH-3 inoperable? The question is set up to leaveHVH-3 running, therefore, would it be wrong to assume operable until an operability recommendation could be produced by engineering? If it is clearly inoperable, thenwhy would an operator try to restart them as stated in two of the distractors?

Questionrevised to remove this concern. The question focus is now on how to reset theHigh Vibration Alarm.

189

ILC-11-2 NRC Exam

89. 059 A2.03 SRO 001Given the following plant conditions: - The plant has experienced a Small Break LOCA inside Containment. - PATH-1 is currently being implemented. - The BOP became distracted and allowed AFW to feed the S/Gs to the followingNarrow Range levels. - "A" S/G: 2%

- "B" S/G: 10%

- "C" S/G: 86%Which ONE (1) of the following completes the statement below?The major concern with "C" S/G is the increased dead weight (1) and isolation offeedwater to "C" S/G is required to be performed IAW (2)

. (1) and water hammer effects on main steamlines(2) FRP-H.3, Response to Steam Generator High Level(1) and water hammer effects on main steamlines(2) Supplement G, Steam Generator Isolation(1) on the S/G vessel external supports in the CV(2) FRP-H.3, Response to Steam Generator High Level(1) on the S/G vessel external supports in the CV(2) Supplement G, Steam Generator Isolation A.B.C.D.

190

ILC-11-2 NRC ExamThe correct answer is A.

A. Correct.B. Incorrect. The first part of the distractor is correct. The second half of the distractorwould reduce S/G level, however, FRP-H.3 has the operator isolate steam prior to draining the S/G.C. Incorrect. The S/G supports would experience a higher load, however, the S/Gsupports are designed to handle full S/Gs as experienced during cold shutdownconditions when S/Gs are placed in wet layup. The steam line supports may bechallenged and the need for additional bracing is addressed in FRP-H.3. The secondhalf of the distractor is correct.D. Incorrect. The S/G supports would experience a higher load, however, the S/Gsupports are designed to handle full S/Gs as experienced during cold shutdownconditions when S/Gs are placed in wet layup. The steam line supports may bechallenged and the need for additional bracing is addressed in FRP-H.3. The secondhalf of the distractor would reduce S/G level, however, FRP-H.3 has the operator isolate steam prior to draining the S/G.The S/G supports would experience a higher load, however, the S/G supports aredesigned to handle full S/Gs as experienced during cold shutdown conditions whenS/Gs are placed in wet layup. The steam line supports may be challenged and theneed for additional bracing is addressed in FRP-H.3.

191

ILC-11-2 NRC Exam Question 89Tier/Group 1/1 K/A Importance Rating - RO 3.7 SRO 3.9Ability to (a) predict the impacts of the following malfunctions or operations on theMFW; and (b) based on those predictions, use procedures to correct, control, ormitigate the consequences of those malfunctions or operations: Overfeeding eventReference(s) - Sim/Plant design, APP-006-F2, FRP-H.3, FRP-H.3BD, Supplement G.Proposed References to be provided to applicants during examination - NoneLearning Objective - FRP-H.3-003 Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content -

41.5 / 43.5 / 45.3 / 45.13Comments - Originally had "increased dead weight on the steam generator vesselsupports." However, every validator chose this distractor due to it being so similar tothe concern with the structural concerns associated with the steam lines.SRO: Assessing plant conditions and then selecting a procedure to mitigate, recover, orwith which to proceed. Procedure selection that is not a major EOP or Red/OrangeFRP. The procedure required to be selected is a Yellow priority FRP. Also, testing theknowledge of the basis for the FRP.MAB Comments:Why is the second part of the distractors incorrect? I do not see any documentationthat supports Supplement G being incorrect. Discuss with licensee to ensure that thereis only one correct answer.

Revised the question to test knowledge of so that thefirst part of the answers will be shorter. C1 and D1 are incorrect since theconcern is with increased dead weight on the main steamline supports and not the steam generator supports.H.3 is a yellow path. The question does not include a reference for the applicant. Isyellow path info required closed book knowledge at Robinson?

No, just knowlege ofthe purpose of the procedure.

192

ILC-11-2 NRC Exam

90. 064 G2.4.46 SRO 001Given the following plant conditions. - The plant was at 100% RTP and experienced a reactor trip coincident with a loss ofthe SUT. - "A" and "B" EDG are supplying power to 480V buses E-1 and E-2. - APP-010-E5, EDG RM A COOL FAN HI TEMP/OVLD, alarm is received. - Readings from a calibrated temperature instrument indicate that EDG A room is at 128°F.Which ONE (1) of the following completes the statements below?"A" EDG (1) required to be declared inoperable. The actions required due to thealarm and temperature reading is to (2)

. (1) is NOT(2) notify the System Engineer to investigate the cause and initiate corrective actionIAW APP-010-E5(1) is NOT(2) shutdown IAW OP-604, Diesel Generators "A" and "B"(1) is(2) notify the System Engineer to investigate the cause and initiate corrective actionIAW APP-010-E5(1) is(2) shutdown IAW OP-604, Diesel Generators "A" and "B" A.B.C.D.

193

ILC-11-2 NRC ExamThe correct answer is A.

A. Correct - Per APP-010-E5, the EDG A must not be declared inoperable unless theroom exceeds 130°F. With the high temperature the system engineer must be notifiedand the cause of the alarm must be investigated and corrective actions initiated.B. Incorrect. The first part of the distractor is correct. If the EDG was running for testingand the high temperature / alarm was due to a fan breaker tripping then the EDG wouldbe shutdown IAW OP-604. Fan operation is not discussed in the stem of the question.This makes this distractor plausible.C. Incorrect. The EDG room temperature must exceed 130°F prior to requiring that theEDG be declared OOS. The second part of the distractor is correct. D. Incorrect - The EDG room temperature must exceed 130°F prior to requiring thatthe EDG be declared OOS. If the EDG was running for testing and the hightemperature / alarm was due to a fan breaker tripping then the EDG would be shutdown IAW OP-604. Fan operation is not discussed in the stem of the question.This makes this distractor plausible.

Question 90Tier/Group 2/1 K/A Importance Rating - RO 4.2 SRO 4.2Emergency Diesel Generator: Ability to verify that the alarms are consistent with theplant conditions.Reference(s) - Sim/Plant design, APP-010, OST-401-2, OP-604Proposed References to be provided to applicants during examination - NoneLearning Objective - EDG06Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content -

41.5 / 43.5 / 45.3 / 45.13Comments - K/A match because candidate know the high temperature limit for EDGoperability.SRO: Candidate must assess plant conditions and then select a procedure to mitigatethe conditions given. In this situation the SRO must know the content of APP-010-E5. Revised 100% power to 100% RTP. Exam validation comment.

194

ILC-11-2 NRC Exam

91. 011 G2.2.38 SRO 001Given the following plant conditions: - Plant is in Mode 3. - PZR level transmitter LT-459 fails LOW. - No operator actions are taken. - At 1700 PZR level is 85.1% and rising at a rate of 0.5%/min. - PZR pressure is being maintained constant.Which ONE(1) of the following completes the statements below?At the current rate of level rise (1) is the EARLIEST time at which the ITS 3.4.9,Pressurizer, will NOT be met. The bases for the limit in this Mode is to ensure that the (2)

. (1) 1712(2) RCS does NOT go solid when criticality is achieved and preserves a steamspace for pressure control(1) 1714(2) RCS does NOT go solid when criticality is achieved and preserves a steamspace for pressure control(1) 1712(2) PZR level remains within the calibrated level range and provide protectionagainst water relief through the PZR PORVs(1) 1714(2) PZR level remains within the calibrated level range and provide protectionagainst water relief through the PZR PORVs A.B.C.D.

195

ILC-11-2 NRC ExamThe correct answer is B.

A. Incorrect. The time given is based on the Pressurizer Water Level - High reactor tripsetpoint of 91%. The second half of the answer is correct.B. Correct.

C. Incorrect. The time given is based on the Pressurizer Water Level - High reactor tripsetpoint of 91%. The last half of the second distractor is from the basis for thePressurizer Water Level-High reactor trip with the exception that it is to provideprotection against water relief through the pressurizer safety valves. The PZR level indication is calibrated throughout the full range of indication. D. Incorrect. The first half of the distractor is correct. The last half of the seconddistractor is from the basis for the Pressurizer Water Level-High reactor trip with theexception that it is to provide protection against water relief through the pressurizersafety valves. The PZR level indication is calibrated throughout the full range ofindication.

Question 91Tier/Group 2/2 K/A Importance Rating - RO 3.6 SRO 4.5Pressurizer Level Control System (PZR LCS): Knowledge of conditions and limitationsin the facility license.Reference(s) - Sim/Plant design, System Description, ITS 3.4.9, ITS 3.4.9 BasesProposed References to be provided to applicants during examination - NoneLearning Objective - PZR 010, 012Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.6 / 45.4 Comments - . SRO: Knowledge of TS bases.

196

ILC-11-2 NRC Exam

92. 045 A2.11 SRO 001Given the following plant conditions: - The plant was at 100% RTP. - Power Distribution Control target values (100%).

N-41: -2.0% N-43: -2.0% N-42: -2.0% N-44: -2.0% - Target Band +/- 5% - APL = 102%

- At 1600 the plant has just experienced two spurious OT Delta T turbine runbacks. - At 1602 the plant stabilized at 88% RTP.

Time N-41AFD N-42 AFD N-43 AFD N-44 AFD 1603 -10.1 -10.2 -10.1 -10.3 1617 - 8.9 -9.0 -8.9 -9.1 1642 - 7.1 -7.2 -7.1 -7.3 1705 - 6.9 -7.0 -6.9 -7.1 1710 - 6.5 -6.6 -6.5 -6.6 Which ONE (1) of the following completes the statement below?IAW ITS 3.2.3, Axial Flux Difference, reactor thermal power (1) and the basis for this action is (2)

.(REFERENCE PROVIDED)(1) is limited to a maximum of 90% RTP (2) the xenon axial distribution at this power level is not a significant accidentanalysis parameter(1) is limited to a maximum of 90% RTP (2) the radial xenon peaking factors assumed in the accident analysis cannot beexceeded at this power level(1) must be reduced to below 50% RTP(2) the xenon axial distribution at this power level is not a significant accidentanalysis parameter(1) must be reduced to below 50% RTP(2) the radial xenon peaking factors assumed in the accident analysis cannot beexceeded at this power level A.B.C.D.

197

ILC-11-2 NRC ExamThe correct answer is C.A. Incorrect. The penalty points have exceeded 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. Per ITS 3.2.3 power must bereduced to below 50%. Power could have stayed between 50% and 90% had less than1 hour of penalty points been accumulated. The second half of the answer is correct.B. Incorrect. The penalty points have exceeded 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. Per ITS 3.2.3 power must bereduced to below 50%. Power could have stayed between 50% and 90% had less than1 hour of penalty points been accumulated. The second half of the distractor is similarto the basis for being outside the acceptable operation limits. Distractor also refers toradial xenon peaking factor vice axial peaking factors.C. Correct.

D. Incorrect. The first half of the distractor is correct. The second half of the distractoris similar to the basis for being outside the acceptable operation limits. Distractor alsorefers to radial xenon peaking factor vice axial peaking factors.

Question 92Tier/Group 2/2 K/A Importance Rating - RO 2.4 SRO 2.9Ability to (a) predict the impacts of the following malfunctions or operation on the MT/Gsystem; and (b) based on those predictions, use procedures to correct, control, ormitigate the consequences of those malfunctions or operations: Control problems inprimary, e.g., axial flux imbalance; need to reduce load on secondaryReference(s) - Sim/Plant design, ITS 3.2.3, FMP-009, ITS 3.2.3 BasesProposed References to be provided to applicants during examination - FMP-009Target and Operating Band Diagram Learning Objective - AOP-15-004, FMP-009-007 Question Source - NEW Question Cognitive Level - H10 CFR Part 55 Content -

41.5 / 43.5 / 45.3 / 45.5Comments - SRO: Application of required actions in accordance with Tech. Specs. and bases ofTech. Specs.

198

ILC-11-2 NRC Exam

93. 029 A2.01 SRO 001Given the following plant conditions: - The plant is at 100% RTP. - Maintenance is preparing to enter the CV to repair a leak on a sensing line. - CV Pressure Relief is in progress with CV pressure cu rrently at 0.05 psig. - CV Purge Gaseous Waste Release Permit has been issued to allow the CV Purgeto commence. - Both R-11 AND R-12 are in service.Which ONE (1) of the following completes the statements below?The CV Purge and CV Pressure Relief (1) be performed concurrently inaccordance with Tech Specs.R-14C, Auxiliary Building Vent Stack Noble Gas Monitor, (2) required to beoperable during the CV Purge in accordance with the ODCM. (1) may(2) is NOT(1) may(2) is(1) may NOT(2) is NOT(1) may NOT (2) is A.B.C.D.The correct answer is C.A. Incorrect. A CV Purge and CV Pressure Relief may not be performed concurrently. This is 3.6.3 prohibits opening the 42 inch purge and 6 inch pressure relief valvessimultaneously. R-14C is normally in service during a pressure relief and purge, but is not required as long as R-11 AND R-12 are both operable. This requirement isspecified in the ODCM and EMP-022, Gaseous Waste Release Permits.

B. Incorrect. See discussion in "A" above. C. Correct.D. Incorrect. The first part of the distractor is correct. See discussion in "A" above.

199

ILC-11-2 NRC Exam Question 93Tier/Group 2 / 2 K/A Importance Rating - RO 2.6 SRO 2.8Ability to (a) predict the impacts of the following malfunctions or operations on theContainment Purge System; and (b) based on those predictions, use procedures tocorrect, control, or mitigate the consequences of those malfunctions or operations:Maintenance or other activity taking place inside containmentReference(s) - Sim/Plant design, EMP-022, ODCM, OP-921Proposed References to be provided to applicants during examination - NoneLearning Objective - CVHVAC 007 Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content -

41.5 / 43.5 / 45.3 / 45.13Comments - SRO: Knowledge Tech Spec requirements that are below the double line and greaterthan 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. Application of Offsite Dose Calculation Manual (ODCM) requirements.

Knowledge of requirements for gaseous release approvals, i.e., release permits.RAB Comments:Add "in accordance with Tech Specs" to the end of the first question statement.Add "in accordance with ODCM" to the end of the first question statement.Revised as recommended.

200

ILC-11-2 NRC Exam

94. G2.1.31 SRO 001Given the following plant conditions: - The Motor Driven Fire Pump (MDFP) was started remotely per OST-603, MDFPand EDFP Test (Weekly). - The MDFP supply breaker tripped open during OST-603.Which ONE(1) of the following completes the statement below?

MDFP indication (1) available on the Containm ent Fire Protection Panel.The Fire Suppression Water Supply System is considered (2)

IAW FP-012, FireProtection Systems Minimum Equipment and Compensatory Actions. (1) is NOT(2) Operable(1) is(2) Operable(1) is NOT(2) Inoperable(1) is (2) Inoperable A.B.C.D.The correct answer is B.A. Incorrect. The pump status lights on the CFPP in the control room will show dualindication. Second half of the distractor correct.B. Correct.

C. Incorrect. The pump status lights on the CFPP in the control room will show dualindication. Per FP-012, only ONE fire pump is required for the Fire Suppression WaterSupply System to be considered OPERABLE. This requirement is met by the EngineDriven Fire Pump being operable. An EIR will be filled out on the MDFP with a sevenday return to service time or initiate an NCR.D. Incorrect. First part of the distractor is correct. Per FP-012, only ONE fire pump isrequired for the Fire Suppression Water Supply System to be considered OPERABLE. This requirement is met by the Engine Driven Fire Pump being operable. An EIR willbe filled out on the MDFP with a seven day return to service time or initiate an NCR.

201

ILC-11-2 NRC ExamExert from FP-012.8.2 Fire Suppression Water Supply System NOTE: Each fire pump provides 100% of the required flow.

Therefore, the loss of one (1)fire pump does not cause the Fire Suppression Water Supply System to be inoperable as described in 8.2.3. 8.2.1 The Fire Suppression Water Supply System shall be operable with: 1. Two (2) fire pumps, each with a capacity of 2,500 gpm, with theirdischarge aligned to the yard loop, AND 2. An operable flow path capable of taking suction from the Unit 2 intake structure AND transferring the water through distribution piping withoperable sectionalizing OR isolation valves to the systems identified inSections 8.3 and 8.4. 8.2.2 With less than the above required equipment operable, restore the inoperableequipment to operable status within seven (7) days.

Question 94Tier 3 K/A Importance Rating - RO 4.2 SRO 4.2Ability to locate control room switches, controls, and indications, and to determine thatthey correctly reflect the desired plant lineup.Reference(s) - Sim/Plant design, FP-012, System DescriptionProposed References to be provided to applicants during examination - NoneLearning Objective - FPW007Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.10, 45.12 Comments - K/A match because candidate must know where the status of the MDFPcan be obtained in the control room.SRO: This question is SRO level because it is administration of fire protection programrequirements for determining operability of the Fire Suppression Water Supply System.Reviewed and approved by MAB.

202

ILC-11-2 NRC Exam

95. G2.1.41 SRO 001The plant is in a refueling outage with core reload in progress.Which ONE(1) of the following completes the statements below with respect to therequired Approval Authority for refueling activities?The (1) is the required Approval Authority for bypassing refueling interlocks.The (2) is the required Approval Authority for unlatching a fuel assembly in the core.(1) Refueling SRO(2) Refueling SRO(1) Shift Manager(2) Refueling SRO(1) Refueling SRO(2) Reactivity Monitor (Reactor Engineer)(1) Shift Manager (2) Reactivity Monitor (Reactor Engineer)

A.B.C.D.

203

ILC-11-2 NRC ExamThe Correct Answer is B.

1. Incorrect - The Shift Manager is the approval authority for bypassing refuelinginterlocks. The second part of distractor is correct.2. Correct
3. Incorrect - The Shift Manager is the approval authority for bypassing refuelinginterlocks. The refueling SRO will make the recommendation. The reactivity monitorwill inform the refueling SRO that all indications are acceptable and recommendsunlatching the fuel assembly. The refueling SRO is the approval authority.4. Incorrect - The first part of distractor is correct. The reactivity monitor will inform therefueling SRO that all indications are acceptable and recommends unlatching the fuelassembly. The refueling SRO is the approval authority.

204

ILC-11-2 NRC Exam Question 95 Tier 3 K/A Importance Rating - RO 4.6 SRO 4.3Knowledge of the refueling processes.Reference(s) - AOP-020, Section B., Proposed References to be provided to applicants during examination - NoneLearning Objective - AOP-020-04 Question Source - NEWQuestion Cognitive Level - F10 CFR Part 55 Content -

41.2 / 41.1 / 43.6 / 45.13Comments - SRO: Fuel handling in the CV is an SRO only function. Refuel floor SROresponsibilities.

205

ILC-11-2 NRC Exam

96. G2.2.35 SRO 001Given the following plant conditions: - A plant heatup from a refueling outage is currently in progress. - Highest available RCS temperature is 325°F and rising. - The "A" MDAFW Pump has been declared OOS.Which ONE (1) of the following completes the statement below?

The current technical specification operational MODE is (1) and IAW the TechSpecs, a change to the next higher MODE based on conditions given is (2)

.(1) 3(2) allowed(1) 4(2) allowed (1) 3(2) NOT allowed(1) 4 (2) NOT allowed A.B.C.D.

206

ILC-11-2 NRC ExamThe correct answer is D.A. Incorrect. LCO 3.0.4b (risk assessment evaluation) is not applicable for ITS 3.7.4,Auxiliary Feedwater (AFW) System. Mode is incorrect.B. Incorrect. LCO 3.0.4b (risk assessment evaluation) is not applicable for ITS 3.7.4,Auxiliary Feedwater (AFW) System. Mode is correct.C. Incorrect. Mode is incorrect. Mode 3 is not entered until temperature is greater thanor equal to 350°F.D. Correct. LCO 3.0.4b (risk assessment evaluation) is not applicable for ITS 3.7.4,Auxiliary Feedwater (AFW) System.Exert from LCO 3.0.4LCO 3.0.4 When an LCO is not met, entry into a MODE or other specifiedcondition in the Applicability shall only be made:a. When the associated ACTIONS to be entered permit continuedoperation in the MODE or other specified condition in the Applicability for an unlimited period of time, orb. After performance of a risk assessment addressinginoperable systems and components, consideration of theresults, determination of the acceptability of entering theMODE or other specified condition in the Applicability, andestablishment of risk management actions, if appropriate;exceptions to this Specification are stated in the individualSpecifications, orc. When an allowance is stated in the individual value, parameter, or other Specification.This Specification shall not prevent changes in MODES or otherspecified conditions in the Applicability that are requiredto comply with ACTIONS or that are part of a shutdown of theunit.

207

ILC-11-2 NRC Exam Question 96Tier 3 K/A Importance Rating - RO 3.6 SRO 4.5Ability to determine Technical Specification Mode of Operation.Reference(s) - Sim/Plant design, ITS Section 1.1, 3.0, 3.7.4Proposed References to be provided to applicants during examination - NoneLearning Objective - Intro to Tech Specs 001, 005; AFW 012Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content -

41.7 / 41.10 / 43.2 / 45.13Comments - SRO: Application of generic Limiting Condition of Operation requirements (LCO 3.0.1thru 3.0.7)MAB Comments:Suggest changing A(2) and B(2) to "Allowed". I do not think conditionalizing the answerchoices adds plausibility.

Revised as recommended.

208

ILC-11-2 NRC Exam

97. G2.2.42 SRO 001Given the following plant conditions:Initial Conditions at 1300 hour0.015 days <br />0.361 hours <br />0.00215 weeks <br />4.9465e-4 months <br />s: - The plant is at 100% RTP. - "B" CCW Pump is under clearance for maintenance. - Subsequently, "B" EDG is declared inoperable due to a broken fuel oil line.Current Conditions at 1700 hour0.0197 days <br />0.472 hours <br />0.00281 weeks <br />6.4685e-4 months <br />s: - Plant continues to operate at 100% RTP with the stated equipment inoperable.Which ONE (1) of the following completes the statement below, based on the currentplant conditions?"C" CCW Pump is (1)

. The most limiting ITS LCO required action is / was (2)

.(1) inoperable(2) ITS LCO 3.0.3.(1) inoperable(2) restore either "B" OR "C" CCW Pump to operable status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.(1) operable(2) the one hour off-site power verification.(1) operable (2) restore either "B" OR "C" CCW Pump to operable status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.

A.B.C.D.

209

ILC-11-2 NRC ExamThe correct answer is A.

A. Correct - Candidate must apply the fact that with "B" EDG inoperable and theredundant CCW pump inoperable the respective feature supported by "B" EDG mustbe declared inoperable. Therefore, both CCW pumps that are powered fromemergency buses are inoperable and ITS LCO 3.0.3 must be entered.B. Incorrect - The first part of the distractor is correct. ITS 3.7.6 does not have an actionstatement for both trains OOS. TheC. Incorrect - The candidate may misapply the section in ITS 3.8.1 that requires you todeclare required features supported by the inoperable DG inoperable when its requiredredundant feature is inoperable. The second half of the distractor would be correct ifonly "B" CCW pump was inoperable with "B" EDG inoperable. The one hour off-sitepower verification still has to occur even with the ITS 3.0.3 entry.D. Incorrect. The candidate may misapply the section in ITS 3.8.1 that requires you todeclare required features supported by the inoperable DG inoperable when its requiredredundant feature is inoperable. The second half of the distractor is correct with onlyone CCW powered from an emergency bus inoperable.

210

ILC-11-2 NRC Exam Question 97Tier 3 K/A Importance Rating - RO 3.9 SRO 4.6Ability to recognize system parameters that are entry-level conditions for TechnicalSpecifications.Reference(s) - Sim/Plant design, ITS 3.7.6, ITS 3.8.1, ITS 3.0.3Proposed References to be provided to applicants during examination - NoneLearning Objective - Intro to Tech Specs 005Question Source - NEW Question Cognitive Level - H 10 CFR Part 55 Content - 41.7

/ 41.10 / 43.2 / 43.3 / 45.3Comments - SRO: Application of required actions in ITS beyond one hour time requirements.MAB Comments:A reference is required to be provided to the applicant if testing greater than one hourTech Spec actions. I think the reference will cause the Mode 3 entry piece to not beplausible.Also, the KA does not appear to be met at the SRO level. The Tech Spec entry is thepart that meets the KA, but that is RO knowledge.Suggestion: write a question where the PORV is on its backup nitrogen supply. Iwould expect the RO to know that the PORV will work, but it would be the SRO thatwould be required to know whether the PORV was operable. This is just one idea -there may be others.Totally revised the question to have one CCW pump OOS with an EDGsubsequently going OOS. Candidate is testing on knowledge of cascading LOCactions with an EDG OOS and application of ITS 3.0.3.Based on exam validation comments, added Initial Conditions at 1300 hours0.015 days <br />0.361 hours <br />0.00215 weeks <br />4.9465e-4 months <br /> andCurrent Conditions at 1700 hours0.0197 days <br />0.472 hours <br />0.00281 weeks <br />6.4685e-4 months <br /> to the stem of the question.

Since fours hourshas elapsed the "C" CCW pump must be declared inoperable.

211

ILC-11-2 NRC Exam

98. G2.3.4 SRO 001Given the following plant conditions: - A Site Area Emergency has been declared and all facilities are activated. - The general radiation levels in Charging Pump Room is 130 Rem/hr. - Entry into the area is required to perform a life saving activity. Which ONE(1) of the following completes the statement below?

Based on EPOSC-04, Emergency Work Control , (1) is the maximum dose that the (2) can authorize the assigned worker.(1) 25 Rem (2) Radiological Control Director(1) 25 Rem(2) Site Emerge ncy Coordinator(1) 10 Rem(2) Radiological Control Director(1) 10 Rem (2) Site Emerge ncy Coordinator A.B.C.D.The correct answer is B.A. Incorrect - The first part of distractor is correct. The RCD can authorize up to 5 Remand must approve several work activities during an event such as waiving requirementsof the Emergency Work Permit. However, the SEC has the approval authority foremergency dose levels to save a life.B. Correct - C. Incorrect - 10 Rem is the maximum for protecting a piece of plant equipment. TheRCD can authorize up to 5 Rem and must approve several work activities during anevent. D. Incorrect - 10 Rem is the maximum for protecting a piece of plant equipment. Thesecond part of the distractor is correct.

212

ILC-11-2 NRC Exam Question 98Tier 3 K/A Importance Rating - RO 3.2 SRO 3.7Knowledge of radiation exposure limits under normal or emergency conditions.Reference(s) - Sim/Plant design, EALs, DOS-NGGC-0004Proposed References to be provided to applicants during examination - EAL MatrixLearning Objective - EAL 004Question Source - BANK Question Cognitive Level - H 10 CFR Part 55 Content - 41.12 / 43.4 / 45.10 Comments - SRO: Emergency Action Level Classification and determination of administrative doselimits.MAB Comments:The KA is not met at the SRO level. Radiation exposure limits are being tested at thebasic rad worker (or RO) level. To hit the KA at the appropriate level, I would suggesttesting emergency dose approval authorization for saving life or equipment. This is acommon SRO question for this KA.The E-Plan classification is not related to the KA.Revised the question to test the candidate's knowledge of approval authority foremergency dose limits and the emergency limits for a life saving activity.

213

ILC-11-2 NRC Exam

99. G2.4.30 SRO 001Given the following plant conditions:A plant event has occurred that has resulted in 10 CFR50.54(x) being invoked fordeviation from approved emergency procedures.IAW AP-030, NRC Reporting Requirements, the NRC is required to be notified within hour(s).1 48 24 A.B.C.D.The correct answer is A.A. Correct.

214

ILC-11-2 NRC Exam Question 99Tier 3 K/A Importance Rating - RO 2.7 SRO 4.1Knowledge of events related to system operation/status that must be reported tointernal organizations or external agencies, such as the State, the NRC, or thetransmission system operator.Reference(s) - AP-030Proposed References to be provided to applicants during examination - NoneLearning Objective - AP-030-003 Question Source - New Question Cognitive Level - H 10 CFR Part 55 Content - 41.10 / 43.5 / 45.11 Comments - SRO: Off-site reporting requirements.MAB Comments:Does Robinson have a learning objective that supports asking this question in a closedbook format? I am asking this to ensure that Robinson Training and OperationsManagement all agree that this is closed book knowledge at your facility. This questionappearing in its current form in your Final Submittal will be viewed as the licenseeofficially agreeing that this is closed book knowledge for SROs at Robinson andtherefore acceptable to appear in that manner on their NRC exam.Operations Management has been consulted.

215

ILC-11-2 NRC Exam 100. G2.4.43 SRO 001Which ONE (1) of the following correctly completes the statements below regarding theprocess for which the NRC Headquarters Operations Officer (HOO) will contact thecontrol room with a notification of a Nuclear Power Plant Attack Message?

An authentication code is contained in a book in the control room that (1) classified as safeguards information. If the incorrect code is given, IAW OMM-001-4,Communications, the SM or his designee is required to (2)

.(1) is NOT(2) receive the message and contact security to validate the threat(1) is(2) receive the message and contact security to validate the threat(1) is NOT(2) hang up and immediately call back the HOO(1) is (2) hang up and immediately call back the HOO A.B.C.D.The correct answer is C.A. Incorrect - The first part is correct. The second part are the actions if a threat wascommunicated to the control room via another source. These actions are IAW withAttachment 1 of AOP-034, Security Events. The question specifically states IAWOMM-001-4 with the call coming from the NRC.B. Incorrect. This information is not safeguards information. Safeguards informationmust be kept unter lock and key and available only to qualified personnel on aneed-to-know basis. The second part are the actions if a threat was communicated tothe control room via another source. These actions are IAW with Attachment 1 ofAOP-034, Security Events. The question specifically states IAW OMM-001-4 with the call coming from the NRC.C. Correct.D. Incorrect - This information is not safeguards information. Safeguards informationmust be kept unter lock and key and available only to qualified personnel on aneed-to-know basis. The second part of the answer is correct.

216

ILC-11-2 NRC ExamQuestion 100Tier 3 K/A Importance Rating - RO 3.2 SRO 3.8Knowledge of emergency communications systems and techniques.Reference(s) - Sim/Plant design, OMM-001-4Proposed References to be provided to applicants during examination - NoneLearning Objective - OMM-001-4 Self StudyQuestion Source - NEW Question Cognitive Level - F 10 CFR Part 55 Content - 41.10 / 45.13 Comments - SRO: Recieving emergency communications from the NRC is an SRO only function atRNP.MAB Comments:This question tests what the HOO will do. Maybe the licensee should not test what the HOO might do? The HOO is not required to follow your OMM procedures. Would it notbe possible that the HOO could ask if you were ready for the code, or wanted the code,prior to providing it? Maybe they would do that to ensure you were ready to receive theinformation. Would that be wrong?

Suggestion: Test where the code is stored or whether or not the code is safeguardsinformation, or something of that nature. The second part of the answer choices areOK. Just the first part needs some work. There appears to be enough info in the OMMprocedure to test something that will ensure only one correct answer to a further extent.Revised the question to test whether or not the information is safeguardsinformation and the actions is the incorrect code is given.

217