05000382/FIN-2012004-03: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 1: | Line 1: | ||
{{finding | {{finding | ||
| title = Failure to Identify and Correct a Torn Diaphragm of a | | title = Failure to Identify and Correct a Torn Diaphragm of a SAFETY-RELATED Air Operated Valve Associated with the Emergency Feedwater System | ||
| docket = 05000382 | | docket = 05000382 | ||
| inspection report = IR 05000382/2012004 | | inspection report = IR 05000382/2012004 |
Latest revision as of 23:15, 29 May 2018
Site: | Waterford |
---|---|
Report | IR 05000382/2012004 Section 1R12 |
Date counted | Sep 30, 2012 (2012Q3) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.12 |
Inspectors (proximate) | P Elkmann M Davis D Allen W Sifre J Laughlin R Cureton R Azua D Overland C Speer |
CCA | P.2, Evaluation |
INPO aspect | PI.2 |
' | |