{{#Wiki_filter:
{{#Wiki_filter:OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION UNITED STATES NUCLEAR REGULATORY COMMISSION REGION III 2443 WARRENVILLE ROAD, SUITE 210 LISLE, IL 60532-4352  January 11, 2013 
[[Issue date::January 11, 2013]]
EA-12-179  Mr. Raymond Lieb
Site Vice President
FirstEnergy Nuclear Operating Company
Davis-Besse Nuclear Power Station 5501 North State Route 2, Mail Stop A-DB-3080 Oak Harbor, OH  43449-9760
SUBJECT: RESPONSE TO DISPUTED CROSS-CUTTING ASPECT DAVIS-BESSE NUCLEAR POWER STATION INSPECTION REPORT NO. 05000346/2012403(DRS)  Dear Mr. Lieb:    On October 17, 2012, you provided a response to a U.S. Nuclear Regulatory Commission (NRC) Inspection Report issued on September 7, 2012, concerning activities conducted at your facility.  Specifically, the letter described FirstEnergy Nuclear Operating Company's (FENOC) dispute of the cross-cutting aspect assigned to a finding.  As a result, the NRC conducted an independent review of the issue.  The enclosure to this letter documents that the NRC
determined that the assigned cross-cutting aspect was appropriate and will remain as
documented in the inspection report.  In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records System (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS).  ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).  However, the material enclosed herewith contains Security-Related Information in accordance with 10 CFR 2.390(d)(1) and its disclosure to unauthorized individuals could present a security
vulnerability.  Therefore, the material in the enclosure will not be made available electronically for public inspection in the NRC Public Document Room or from the PARS component of NRC's ADAMS.  If you choose to provide a response and Security-Related Information is necessary to provide an acceptable response, please mark your entire response "Security-Related
Information - Withhold from public disclosure under 10 CFR 2.390" in accordance with
10 CFR 2.390(d)(1) and follow the instructions for withholding in 10 CFR 2.390 (b)(1).  In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response.  Enclosure contains Sensitive Unclassified Non-Safeguards Information.  When separated from enclosure, this transmittal document is decontrolled. 
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION R. Lieb      -2- 
Should you have any questions concerning this inspection, we will be pleased to discuss them with you. Sincerely,  /RA/ 
Cynthia D. Pederson Deputy Regional Administrator 
Docket No. 50-346
License No. NPF-3 Nonpublic Enclosure: NRC Assessment of Disputed Cross-Cutting Aspect to Finding 05000346/2012403-01  cc w/encl: S. Coker, NSIR/DSO/DDSO/ST  R. Albert, NSIR
T. Dimitriadis, RI
B. Desai, RII  M. Haire, RIV  M. Bear, State Liaison Officer,
  Ohio Emergency Management Agency 
cc w/o encl: Distribution via ListServŽ 
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION R. Lieb      -2-  Should you have any questions concerning this inspection, we will be pleased to discuss them with you. Sincerely,  /RA/ 
Cynthia D. Pederson Deputy Regional Administrator  Docket No. 50-346 License No. NPF-3 Nonpublic Enclosure: NRC Assessment of Disputed Cross-Cutting Aspect to Finding 05000346/2012403-01  cc w/encl: S. Coker, NSIR/DSO/DDSO/ST  R. Albert, NSIR  T. Dimitriadis, RI
B. Desai, RII  M. Haire, RIV  M. Bear, State Liaison Officer,
  Ohio Emergency Management Agency  cc w/o encl: Distribution via ListServŽ
DISTRIBUTION w/o encl: John Cassidy
RidsNrrDorlLpl3-2 Resource  RidsNrrPMDavisBesse Resource RidsNrrDirsIrib Resource Chuck Casto Cynthia Pederson
Steven Orth Jared Heck Allan Barker
Christine Lipa Carole Ariano Linda Linn DRPIII DRSIII
Tammy Tomczak ROPreports.Resource@nrc.gov 
 
DOCUMENT NAME:  Ltr 011113 Davis-Besse Response to Cross-Cutting Aspect Dispute OUO - Cover Letter.docx  Publicly Available  Non-Publicly Available  Sensitive  Non-Sensitive To receive a copy of this document, indicate in the concurrence box "C" = Copy without attach/encl "E" = Copy with attach/encl "N" = No copy OFFICE RIII  RIII  RIII  RIII  RIII  NAME NEgan:cs JMaynen for RSkokowski KO'Brien PLougheed for SOrth CPederson DATE 12/19/12 12/20/12 12/21/12 12/21/12 01/11/13 OFFICIAL RECORD COPY 


EA-12-179 Mr. Raymond Lieb Site Vice President FirstEnergy Nuclear Operating Company Davis-Besse Nuclear Power Station 5501 North State Route 2, Mail Stop A-DB-3080 Oak Harbor, OH 43449-9760
SUBJECT: RESPONSE TO DISPUTED CROSS-CUTTING ASPECT DAVIS-BESSE NUCLEAR POWER STATION INSPECTION REPORT NO. 05000346/2012403(DRS)
==Dear Mr. Lieb:==
On October 17, 2012, you provided a response to a U.S. Nuclear Regulatory Commission (NRC) Inspection Report issued on September 7, 2012, concerning activities conducted at your facility. Specifically, the letter described FirstEnergy Nuclear Operating Company's (FENOC) dispute of the cross-cutting aspect assigned to a finding. As a result, the NRC conducted an independent review of the issue. The enclosure to this letter documents that the NRC determined that the assigned cross-cutting aspect was appropriate and will remain as documented in the inspection report. In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records System (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, the material enclosed herewith contains Security-Related Information in accordance with 10 CFR 2.390(d)(1) and its disclosure to unauthorized individuals could present a security vulnerability. Therefore, the material in the enclosure will not be made available electronically for public inspection in the NRC Public Document Room or from the PARS component of NRC's ADAMS. If you choose to provide a response and Security-Related Information is necessary to provide an acceptable response, please mark your entire response "Security-Related Information - Withhold from public disclosure under 10 CFR 2.390" in accordance with 10 CFR 2.390(d)(1) and follow the instructions for withholding in 10 CFR 2.390 (b)(1). In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response. Enclosure contains Sensitive Unclassified Non-Safeguards Information. When separated from enclosure, this transmittal document is decontrolled. Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely,/RA/
Cynthia D. Pederson Deputy Regional Administrator Docket No. 50-346 License No. NPF-3 Nonpublic
===Enclosure:===
NRC Assessment of Disputed Cross-Cutting Aspect to Finding 05000346/2012403-01 cc w/encl: S. Coker, NSIR/DSO/DDSO/ST R. Albert, NSIR T. Dimitriadis, RI B. Desai, RII M. Haire, RIV M. Bear, State Liaison Officer, Ohio Emergency Management Agency cc w/o encl: Distribution via ListServŽ
}}
}}

Revision as of 08:25, 28 March 2018

Ltr 01/11/13 Davis-Besse Response to Disputed Cross-Cutting Aspect in Inspection Report No. 05000346-12-403(DRS) (Cover Letter Only)
ML13014A387
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 01/11/2013
From: Pederson C D
Region 3 Administrator
To: Lieb R
FirstEnergy Nuclear Generation Corp
References
EA-12-179, IR-12-403
Download: ML13014A387 (3)


See also: IR 05000346/2012403

Text

OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION UNITED STATES NUCLEAR REGULATORY COMMISSION REGION III 2443 WARRENVILLE ROAD, SUITE 210 LISLE, IL 60532-4352 January 11, 2013

EA-12-179 Mr. Raymond Lieb

Site Vice President

FirstEnergy Nuclear Operating Company

Davis-Besse Nuclear Power Station 5501 North State Route 2, Mail Stop A-DB-3080 Oak Harbor, OH 43449-9760

SUBJECT: RESPONSE TO DISPUTED CROSS-CUTTING ASPECT DAVIS-BESSE NUCLEAR POWER STATION INSPECTION REPORT NO. 05000346/2012403(DRS) Dear Mr. Lieb: On October 17, 2012, you provided a response to a U.S. Nuclear Regulatory Commission (NRC) Inspection Report issued on September 7, 2012, concerning activities conducted at your facility. Specifically, the letter described FirstEnergy Nuclear Operating Company's (FENOC) dispute of the cross-cutting aspect assigned to a finding. As a result, the NRC conducted an independent review of the issue. The enclosure to this letter documents that the NRC

determined that the assigned cross-cutting aspect was appropriate and will remain as

documented in the inspection report. In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records System (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, the material enclosed herewith contains Security-Related Information in accordance with 10 CFR 2.390(d)(1) and its disclosure to unauthorized individuals could present a security

vulnerability. Therefore, the material in the enclosure will not be made available electronically for public inspection in the NRC Public Document Room or from the PARS component of NRC's ADAMS. If you choose to provide a response and Security-Related Information is necessary to provide an acceptable response, please mark your entire response "Security-Related

Information - Withhold from public disclosure under 10 CFR 2.390" in accordance with

10 CFR 2.390(d)(1) and follow the instructions for withholding in 10 CFR 2.390 (b)(1). In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response. Enclosure contains Sensitive Unclassified Non-Safeguards Information. When separated from enclosure, this transmittal document is decontrolled.

OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION R. Lieb -2-

Should you have any questions concerning this inspection, we will be pleased to discuss them with you. Sincerely, /RA/

Cynthia D. Pederson Deputy Regional Administrator

Docket No. 50-346

License No. NPF-3 Nonpublic Enclosure: NRC Assessment of Disputed Cross-Cutting Aspect to Finding 05000346/2012403-01 cc w/encl: S. Coker, NSIR/DSO/DDSO/ST R. Albert, NSIR

T. Dimitriadis, RI

B. Desai, RII M. Haire, RIV M. Bear, State Liaison Officer,

Ohio Emergency Management Agency

cc w/o encl: Distribution via ListServŽ

OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION R. Lieb -2- Should you have any questions concerning this inspection, we will be pleased to discuss them with you. Sincerely, /RA/

Cynthia D. Pederson Deputy Regional Administrator Docket No. 50-346 License No. NPF-3 Nonpublic Enclosure: NRC Assessment of Disputed Cross-Cutting Aspect to Finding 05000346/2012403-01 cc w/encl: S. Coker, NSIR/DSO/DDSO/ST R. Albert, NSIR T. Dimitriadis, RI

B. Desai, RII M. Haire, RIV M. Bear, State Liaison Officer,

Ohio Emergency Management Agency cc w/o encl: Distribution via ListServŽ

DISTRIBUTION w/o encl: John Cassidy

RidsNrrDorlLpl3-2 Resource RidsNrrPMDavisBesse Resource RidsNrrDirsIrib Resource Chuck Casto Cynthia Pederson

Steven Orth Jared Heck Allan Barker

Christine Lipa Carole Ariano Linda Linn DRPIII DRSIII

Tammy Tomczak ROPreports.Resource@nrc.gov

DOCUMENT NAME: Ltr 011113 Davis-Besse Response to Cross-Cutting Aspect Dispute OUO - Cover Letter.docx Publicly Available Non-Publicly Available Sensitive Non-Sensitive To receive a copy of this document, indicate in the concurrence box "C" = Copy without attach/encl "E" = Copy with attach/encl "N" = No copy OFFICE RIII RIII RIII RIII RIII NAME NEgan:cs JMaynen for RSkokowski KO'Brien PLougheed for SOrth CPederson DATE 12/19/12 12/20/12 12/21/12 12/21/12 01/11/13 OFFICIAL RECORD COPY