IR 05000346/2024401

From kanterella
Jump to navigation Jump to search
Security Baseline Inspection Report 05000346/2024401
ML24208A155
Person / Time
Site: Davis Besse 
Issue date: 07/30/2024
From: Michael Ziolkowski
NRC/RGN-III/DRSS
To: Tony Brown
Vistra Operations Company
References
IR 2024401
Download: ML24208A155 (1)


Text

SUBJECT:

DAVIS-BESSE NUCLEAR POWER STATION - SECURITY BASELINE INSPECTION REPORT 05000346/2024401

Dear Terry Brown:

On June 20, 2024, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Davis-Besse Nuclear Power Station and discussed the results of this inspection with you and other members of your staff. The results of this inspection are documented in the enclosed report.

No findings or violations of more than minor significance were identified during this inspection.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely, Michael E. Ziolkowski, Chief Security, Emergency Preparedness, and Incident Response Branch Division of Radiological Safety and Security Docket No. 05000346 License No. NPF-3

Enclosure:

As stated

Inspection Report

Docket Number:

05000346

License Number:

NPF-3

Report Number:

05000346/2024401

Enterprise Identifier:

I-2024-401-0078

Licensee:

Vistra Operations Company LLC

Facility:

Davis-Besse Nuclear Power Station

Location:

Oak Harbor, OH

Inspection Dates:

April 15, 2024, to June 20, 2024

Inspectors:

S. Cavanaugh, Physical Security Inspector

N. Egan, Senior Physical Security Inspector

Approved By:

Michael E. Ziolkowski, Chief

Security, Emergency Preparedness, and Incident Response Branch

Division of Radiological Safety and Security

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting a security baseline inspection at Davis-Besse Nuclear Power Station, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors.

Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.

List of Findings and Violations

No findings or violations of more than minor significance were identified.

Additional Tracking Items

None.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html.

Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2201, Security Inspection Program for Commercial Nuclear Power Reactors. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.

SAFEGUARDS

71130.01 - Access Authorization

The inspectors evaluated the access authorization program. The following elements were evaluated:

Access Authorization

(1)

  • Tier I: All Requirements
  • Tier II: 02.05 a-b; 02.06 a-b; 02.08 a-b
  • Tier III: 02.10 a-c; 02.11 a

71130.04 - Equipment Performance, Testing, and Maintenance

The inspectors evaluated the security equipment testing and maintenance program. The following elements were evaluated from this IP dated January 1, 2024.

Equipment Performance, Testing, and Maintenance (1 Sample)

(1)

  • Tier I: All
  • Tier II: 02.11 a-b; 02.12 a; 02.13 a
  • Tier III: 02.15 a-b

71130.05 - Protective Strategy Evaluation

The inspectors evaluated the licensee's protective strategy through completion of the following

procedure elements: Protective Strategy Evaluation

(1)

  • Observed annual force-on-force exercise on May 15, 2024

71130.09 - Security Plan Changes

The inspectors evaluated the security plan changes through completion of the following procedure elements:

Security Plan Changes (1 Partial)

(1)

(Partial)

The opportunity to apply this procedure was not available in accordance with IMC 0306. This sample was not available because the licensee did not conduct the activity covered by this IP. Specifically, the licensee has not initiated a physical security plan change in accordance with 10 CFR 50.54(p(2) since the last performance of this IP.

OTHER ACTIVITIES - BASELINE

===71151 - Performance Indicator Verification The inspectors verified licensee performance indicators submittals listed below:

PP01: Protected Area Security Equipment Performance Index Sample (IP Section 02.17)

=

(1)

  • March 1, 2023, through March 1,

INSPECTION RESULTS

No findings were identified.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

  • On June 20, 2024, the inspectors presented the security baseline inspection results to Terry Brown and other members of the licensee staff.

DOCUMENTS REVIEWED

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

Miscellaneous

Select Access Authorization Personnel Packages from

April 1, 2021, to April 1, 2024

NOBP-LP-1001

Fingerprint Processing

NOBP-LP-1003

Unescorted Access In-Processing

NOBP-LP-1004

Behavioral Observation

NOBP-LP-1005

Potentially Disqualifying Information Adjudication, Denial,

and Appeal

NOBP-LP-1006

PADS Security Operations and Control

NOBP-LP-1008

Protection of Confidential Information

NOBP-LP-1010

Unescorted Access Background Investigation

NOBP-LP-1017

Critical Group

NOBP-LP-1018

HR Background Investigation Guidance for Reviewing

Officials

Procedures

NOP-LP-1002

Fitness For Duty Program

ATA-2023-2858

NRC Access Authorization (Corporate) Inspection

IP71130.01 Self-Assessment

01/04/2024

EHN-NSQ-23-

0005

Industry Audit of All Clear Screening, Inc.

03/31/2023

EHN-NSQ-23-

0018

Industry Audit of Confidential Services, Inc.

06/19/2023

71130.01

Self-Assessments

MS-C-23-08-20

Quality Assurance Audit Report

09/18/2023

CR-2024-03364

04/17/2024

CR-2024-03368

04/17/2024

Corrective Action

Documents

CR-2024-03412

04/18/2024

IS-DP-00501

Testing and Maintenance of Security Systems

IS-DP-00503

Security Communications

IS-DP-00513

Weapons Program

IS-DP-04001

Operational Test for the Walk-Through Metal Detector

IS-DP-04011

Inspection of the Vehicle Barrier Systems

IS-DP-04016

Semi-Automatic Rifle Inspection

71130.04

Procedures

IS-DP-04907

Intrusion Detection Equipment

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

IS-DP-04920

Nuclear Security Weekly Operability Testing

IS-DP-04920

Nuclear Security Weekly Operability Testing

IS-DP-04922

Quarterly Test of Security Alarms and Tampers

IS-DP-04923

Motorized Delay Barrier Operability Test

IS-DP-04931

ROCA Intrusion Detection Equipment

IS-DP-04934

Monthly ROCA Operability Test

NOP-LP-1301

Security Testing, Maintenance and Inspection

Self-Assessments

ATA-2023-11896

24 Security Equipment Performance, Testing and

Maintenance

71130.05

Corrective Action

Documents

Resulting from

Inspection

CR-2024-04445

05/16/2024

71151

Miscellaneous

Security Performance Indicator Data from March 2023 to

March 2024