| title = Untimely Corrective Action To Address Crescent Area Unit Cooler Operability
| title = Untimely Corrective Action to Address Crescent Area Unit Cooler Operability
| docket = 05000333
| docket = 05000333
| inspection report = IR 05000333/2012004
| inspection report = IR 05000333/2012004

Latest revision as of 20:45, 20 February 2018

01
Site: FitzPatrick Constellation icon.png
Report IR 05000333/2012004 Section 1R15
Date counted Sep 30, 2012 (2012Q3)
Type: NCV: Green
cornerstone Mitigating Systems
Identified by: NRC identified
Inspection Procedure: IP 71111.15
Inspectors (proximate) L Scholl
M Gray
T Burns
J Laughlin
E Knutson
B Sienel
R Rolph
S Hammann
CCA P.3, Resolution
INPO aspect PI.3
'