{{#Wiki_filter:October 30, 2008 Dr. John Bernard Director of Reactor Operations MIT Nuclear Reactor Laboratory Mail Stop NW12-208a 138 Albany Street Cambridge, MA 02139  
{{#Wiki_filter:October 30, 2008 Dr. John Bernard Director of Reactor Operations MIT Nuclear Reactor Laboratory Mail Stop NW12-208a 138 Albany Street Cambridge, MA 02139


==SUBJECT:==
==SUBJECT:==
MASSACHUSETTS INSTITUTE OF TECHNOLOGY-REQUEST FOR ADDITIONAL INFORMATION REGARDING AMENDMENT REQUEST (TAC No. MC 5155)  
MASSACHUSETTS INSTITUTE OF TECHNOLOGY-REQUEST FOR ADDITIONAL INFORMATION REGARDING AMENDMENT REQUEST (TAC No.
MC 5155)


==Dear Dr. Bernard:==
==Dear Dr. Bernard:==
We are continuing our review of your request for amendment for Amended Facility Operating License No. R-37 for the Massachusetts Institute of Technology (MIT) Nuclear Reactor which you submitted on May 7, 2008. Questions have arisen for which we require additional information and clarification. Please provide responses to the enclosed request for additional information within 30 days of the date of this letter. In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation. Following receipt of the additional information, we will continue our evaluation of your request for amendment. If you have any questions regarding this review, please contact me at 301-415-3398. Sincerely, /RA/ Cindy Montgomery, Project Manager Research and Test Reactors Branch A Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-20 License No. R-37  
 
We are continuing our review of your request for amendment for Amended Facility Operating License No. R-37 for the Massachusetts Institute of Technology (MIT) Nuclear Reactor which you submitted on May 7, 2008. Questions have arisen for which we require additional information and clarification. Please provide responses to the enclosed request for additional information within 30 days of the date of this letter. In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation. Following receipt of the additional information, we will continue our evaluation of your request for amendment.
If you have any questions regarding this review, please contact me at 301-415-3398.
Sincerely,
                                              /RA/
Cindy Montgomery, Project Manager Research and Test Reactors Branch A Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-20 License No. R-37


==Enclosure:==
==Enclosure:==
As stated cc w/enclosure: See next page Massachusetts Institute of Technology Docket No. 50-20 cc:
City Manager City Hall Cambridge, MA  02139


Department of Environmental Protection One Winter Street Boston, MA  02108
As stated cc w/enclosure: See next page


Director Radiation Control Program Department of Public Health 90 Washington Street Dorchester, MA 02121  
Massachusetts Institute of Technology    Docket No. 50-20 cc:
City Manager City Hall Cambridge, MA 02139 Department of Environmental Protection One Winter Street Boston, MA 02108 Director Radiation Control Program Department of Public Health 90 Washington Street Dorchester, MA 02121 Nuclear Preparedness Manager Massachusetts Emergency Management Agency 400 Worcester Road Framingham, MA 01702-5399 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611


Nuclear Preparedness Manager Massachusetts Emergency Management Agency  400 Worcester Road  Framingham, MA 01702-5399
October 30, 2008 Dr. John Bernard Director of Reactor Operations MIT Nuclear Reactor Laboratory Mail Stop NW12-208a 138 Albany Street Cambridge, MA 02139
 
Test, Research, and Training  Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL  32611
 
October 30, 2008 Dr. John Bernard Director of Reactor Operations MIT Nuclear Reactor Laboratory Mail Stop NW12-208a 138 Albany Street Cambridge, MA 02139  


==SUBJECT:==
==SUBJECT:==
MASSACHUSETTS INSTITUTE OF TECHNOLOGY-REQUEST FOR ADDITIONAL INFORMATION REGARDING AMENDMENT REQUEST (TAC No. MC 5155)  
MASSACHUSETTS INSTITUTE OF TECHNOLOGY-REQUEST FOR ADDITIONAL INFORMATION REGARDING AMENDMENT REQUEST (TAC No.
MC 5155)


==Dear Dr. Bernard:==
==Dear Dr. Bernard:==
We are continuing our review of your request for amendment for Amended Facility Operating License No. R-37 for the Massachusetts Institute of Technology (MIT) Nuclear Reactor which you submitted on May 7, 2008. Questions have arisen for which we require additional information and clarification. Please provide responses to the enclosed request for additional information within 30 days of the date of this letter. In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation. Following receipt of the additional information, we will continue our evaluation of your request for amendment. If you have any questions regarding this review, please contact me at 301-415-3398.       Sincerely,       /RA/ Cindy Montgomery, Project Manager Research and Test Reactors Branch A Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-20 License No. R-37  
 
We are continuing our review of your request for amendment for Amended Facility Operating License No. R-37 for the Massachusetts Institute of Technology (MIT) Nuclear Reactor which you submitted on May 7, 2008. Questions have arisen for which we require additional information and clarification. Please provide responses to the enclosed request for additional information within 30 days of the date of this letter. In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation. Following receipt of the additional information, we will continue our evaluation of your request for amendment.
If you have any questions regarding this review, please contact me at 301-415-3398.
Sincerely,
                                              /RA/
Cindy Montgomery, Project Manager Research and Test Reactors Branch A Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-20 License No. R-37


==Enclosure:==
==Enclosure:==


As stated cc w/enclosure: See next page DISTRIBUTION
As stated cc w/enclosure: See next page DISTRIBUTION:
: PUBLIC PRTA r/f RidsNrrDprPrta Accession Number: ML083020303 OFFICE PRTA:PM PRTA:LA PRTA:BC PRTA: PM NAME CMontgomery ckm EBarnhill eeb KBrock kmb AAdams aa DATE 10/30/08 10/30/08 10/30/08 10/30/08 OFFICIAL RECORD COPY REQUEST FOR ADDITIONAL INFORMATION REGARDING APPLICATION FOR LICENSE AMENDMENT MIT NUCLEAR REACTOR DOCKET NO. 50-20
PUBLIC                 PRTA r/f             RidsNrrDprPrta Accession Number: ML083020303 OFFICE             PRTA:PM             PRTA:LA               PRTA:BC             PRTA: PM NAME             CMontgomery ckm         EBarnhill eeb         KBrock kmb       AAdams aa DATE           10/30/08               10/30/08                 10/30/08       10/30/08 OFFICIAL RECORD COPY
: 1. What would the radiological impact be if the new sole heat exchanger developed a leak?   How quickly would a leak be detected both when in operation and when shutdown? 2. Please provide additional detail to the statement "We note that reactor safety is not a function of the number of heat exchangers. The issue is whether or not the total heat transfer surface area needed for system heat removal is available."}}
 
REQUEST FOR ADDITIONAL INFORMATION REGARDING APPLICATION FOR LICENSE AMENDMENT MIT NUCLEAR REACTOR DOCKET NO. 50-20
: 1. What would the radiological impact be if the new sole heat exchanger developed a leak?
How quickly would a leak be detected both when in operation and when shutdown?
: 2. Please provide additional detail to the statement We note that reactor safety is not a function of the number of heat exchangers. The issue is whether or not the total heat transfer surface area needed for system heat removal is available.}}

Latest revision as of 12:43, 14 November 2019

Massachusetts Institute of Technology-Request for Additional Information Regarding Amendment Request
ML083020303
Person / Time
Site: MIT Nuclear Research Reactor
Issue date: 10/30/2008
From: Cindy Montgomery
Division of Policy and Rulemaking
To: Bernard J
Massachusetts Institute of Technology (MIT)
montgomery c 415-3398
References
TAC MC5155
Download: ML083020303 (5)


Text

October 30, 2008 Dr. John Bernard Director of Reactor Operations MIT Nuclear Reactor Laboratory Mail Stop NW12-208a 138 Albany Street Cambridge, MA 02139

SUBJECT:

MASSACHUSETTS INSTITUTE OF TECHNOLOGY-REQUEST FOR ADDITIONAL INFORMATION REGARDING AMENDMENT REQUEST (TAC No.

MC 5155)

Dear Dr. Bernard:

We are continuing our review of your request for amendment for Amended Facility Operating License No. R-37 for the Massachusetts Institute of Technology (MIT) Nuclear Reactor which you submitted on May 7, 2008. Questions have arisen for which we require additional information and clarification. Please provide responses to the enclosed request for additional information within 30 days of the date of this letter. In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation. Following receipt of the additional information, we will continue our evaluation of your request for amendment.

If you have any questions regarding this review, please contact me at 301-415-3398.

Sincerely,

/RA/

Cindy Montgomery, Project Manager Research and Test Reactors Branch A Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-20 License No. R-37

Enclosure:

As stated cc w/enclosure: See next page

Massachusetts Institute of Technology Docket No. 50-20 cc:

City Manager City Hall Cambridge, MA 02139 Department of Environmental Protection One Winter Street Boston, MA 02108 Director Radiation Control Program Department of Public Health 90 Washington Street Dorchester, MA 02121 Nuclear Preparedness Manager Massachusetts Emergency Management Agency 400 Worcester Road Framingham, MA 01702-5399 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611

October 30, 2008 Dr. John Bernard Director of Reactor Operations MIT Nuclear Reactor Laboratory Mail Stop NW12-208a 138 Albany Street Cambridge, MA 02139

SUBJECT:

MASSACHUSETTS INSTITUTE OF TECHNOLOGY-REQUEST FOR ADDITIONAL INFORMATION REGARDING AMENDMENT REQUEST (TAC No.

MC 5155)

Dear Dr. Bernard:

We are continuing our review of your request for amendment for Amended Facility Operating License No. R-37 for the Massachusetts Institute of Technology (MIT) Nuclear Reactor which you submitted on May 7, 2008. Questions have arisen for which we require additional information and clarification. Please provide responses to the enclosed request for additional information within 30 days of the date of this letter. In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation. Following receipt of the additional information, we will continue our evaluation of your request for amendment.

If you have any questions regarding this review, please contact me at 301-415-3398.

Sincerely,

/RA/

Cindy Montgomery, Project Manager Research and Test Reactors Branch A Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-20 License No. R-37

Enclosure:

As stated cc w/enclosure: See next page DISTRIBUTION:

PUBLIC PRTA r/f RidsNrrDprPrta Accession Number: ML083020303 OFFICE PRTA:PM PRTA:LA PRTA:BC PRTA: PM NAME CMontgomery ckm EBarnhill eeb KBrock kmb AAdams aa DATE 10/30/08 10/30/08 10/30/08 10/30/08 OFFICIAL RECORD COPY

REQUEST FOR ADDITIONAL INFORMATION REGARDING APPLICATION FOR LICENSE AMENDMENT MIT NUCLEAR REACTOR DOCKET NO. 50-20

1. What would the radiological impact be if the new sole heat exchanger developed a leak?

How quickly would a leak be detected both when in operation and when shutdown?

2. Please provide additional detail to the statement We note that reactor safety is not a function of the number of heat exchangers. The issue is whether or not the total heat transfer surface area needed for system heat removal is available.