MONTHYEARML20211A1421999-08-19019 August 1999 Ack Receipt of Application for License Renewal for Massachusetts Institute of Technology Research Reactor Dtd 990708.Existing License Will Not Be Deemed to Have Expired Until Application Has Been Finally Determined by Commission Project stage: Other ML0215003512002-06-0606 June 2002 Mit - Request for Additional Information License Renewal Request Project stage: RAI ML0733404852007-11-30030 November 2007 Massachusetts Institute of Technology, Request for Additional Information, License Renewal Project stage: RAI ML0803900392008-02-0808 February 2008 E-mail Draft RAIs Project stage: Draft Other ML0803900352008-02-0808 February 2008 Mitr RAIs Project stage: Other ML0803804532008-02-0808 February 2008 Massachusetts Institute of Technology (Mit) Draft RAI Regarding Application for License Renewal Project stage: Draft RAI ML0810006272008-02-22022 February 2008 Massachusetts Institute of Technology Research Reactor, Response to Request for Additional Information 2/22/08 Project stage: Response to RAI ML0807103522008-03-12012 March 2008 Massachusetts Institute of Technology - Request for Additional Information License Renewal Request Project stage: RAI ML0810205372008-04-21021 April 2008 Massachusetts Institute of Technology - Request for Additional Information License Renewal Request Project stage: RAI ML0808404452008-05-0202 May 2008 Determination of Acceptability and Sufficiency for Docketing and Opportunity for a Hearing Regarding the Application from the Massachusetts Institute of Technology (Mit) for Renewal of the Facility Operating License for the Mit Reactor Project stage: Other ML0815602462008-05-29029 May 2008 Massachusetts Institute of Technology - Response to Request for Additional Information License Renewal Request Project stage: Response to RAI ML0824010502008-08-21021 August 2008 Massachusetts Institute of Technology, Response to Request for Additional Information License Renewal Request 14.1 Project stage: Response to RAI ML0824705622008-08-26026 August 2008 Massachusetts Institute of Technology - Response to Request for Additional Information License Renewal Request Project stage: Response to RAI ML0825608062008-09-24024 September 2008 Massachusetts Institute of Technology, Request for Additional Information, Application for License Renewal Project stage: RAI ML0829004882008-10-0606 October 2008 Massachusetts Institute of Technology - Request for Additional Information License Renewal Request (TAC No. MA6084); Response Project stage: Request ML0829102412008-10-0707 October 2008 Massachusetts Institute of Technology - Request for Additional Information License Renewal Request Project stage: Request ML0834300062008-12-0101 December 2008 Massachusetts Institute of Technology, Submittal of Response to Request for Additional Information for License Renewal Project stage: Response to RAI ML0915907372009-07-21021 July 2009 Massachusetts Institute of Technology - Request for Additional Information Concerning Application for License Renewal Project stage: RAI ML0929302732009-10-0505 October 2009 Massachusetts Institute of Technology - Submittal of Revised Technical Specifications for Relicensing Project stage: Request ML0929302782009-10-0909 October 2009 Massachusetts Institute of Technology, Response to Request for Additional Information, Dated 07/02/09 Project stage: Response to RAI ML0935216702009-12-23023 December 2009 Massachusetts Institute of Technology, Request for Additional Information Regarding License Renewal Project stage: RAI ML1009703682010-03-30030 March 2010 Mit - Response to Request for Additional Information Regarding Renewal of License No. R-37, Dated 12/23/2009 Project stage: Response to RAI ML1019500022010-07-16016 July 2010 Massachusetts Institute of Technology (Mit), Request for Additional Information Regarding Mit Research Reactor License Renewal Project stage: RAI ML1023100322010-08-0606 August 2010 Mit Nuclear Reactor Lab, Response to Request for Additional Information Re Relicensing Project stage: Response to RAI ML1024401222010-08-26026 August 2010 Massachusetts Institute of Technology, Submittal of Revised Pages for TS No. 3.3.5 and No. 4.2(4) Project stage: Other ML1010202812010-09-27027 September 2010 FRN: General Notice, Massachusetts Institute of Technology Docket No. 50-020 Massachusetts Institute of Technology Research Reactor Environmental Assessment and Finding of No Significant Impact Project stage: Request ML1010202112010-10-0505 October 2010 Massachusetts Institute of Technology-Environmental Assessment Regarding Renewal of Facility Operating License No. R-37 for the Massachusetts Institute of Technology Research Reactor Project stage: Other ML1025002472010-11-0101 November 2010 Massachusetts Institute of Technology, Issuance of Renewed Facility Operating License No. R-37 Project stage: Request NRC-2010-0313, FRN: General Notice, Notice of Issuance of Massachusetts Institute of Technology Renewed Facility Operating License No. R-372010-11-0101 November 2010 FRN: General Notice, Notice of Issuance of Massachusetts Institute of Technology Renewed Facility Operating License No. R-37 Project stage: Approval ML1023200682010-11-0101 November 2010 Massachusetts Institute of Technology, Technical Specifications, Renewed Operating License No. R-37 Project stage: Other ML1023200822010-11-0101 November 2010 Massachusetts Institute of Technology, Safety Evaluation, Renewed Facility Operating License No. R-37 Project stage: Approval ML1023201012010-11-0101 November 2010 FRN: General Notice, Notice of Issuance of Massachusetts Institute of Technology Renewed Facility Operating License No. R-37 Project stage: Approval ML1023105452010-11-0101 November 2010 Massachusetts Institute of Technology-Issuance of Renewed Facility License No. R-37 for the Massachusetts Institute of Technology Reactor Project stage: Approval 2008-08-21
[Table View] |
Text
Docket No. 50-20 cc: See next page November 30, 2007 Dr. John A. Bernard, Director Nuclear Reactor Laboratory Massachusetts Institute of Technology 138 Albany Street Cambridge, MA 02139-4296
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION, RE: LICENSE RENEWAL (TAC NO. MA6084)
Dear Dr. Bernard:
We are continuing our review of your July 8, 1999 application, and associated supplements, for the renewal of the Massachusetts Institute of Technologys (MIT) Research Reactor Amended Facility Operating License No. R-37. MITs January 29, 2004, response to an NRC request for additional information (RAI) made the following statements:
Response 33.a) "Process uncertainty is addressed by selecting initial conditions that correspond to the LSSS instead of the normal operational values or even the scram values. This was not done originally for all safety analyses but, as a result of other questions in this series, it has now been done."
Response 78. "All transient calculations in Chapter 13 (loss of primary flow, ramp reactivity insertion, step reactivity insertion) have been redone using primary coolant flow of 1800 gpm, which is the LSSS."
Please provide copies of the following:
- 1) Each of the redone Chapter 13 calculations and supporting documentation.
- 2) The dose calculations for the MHA analysis, including the dispersion analysis and supporting documentation.
In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation.
Sincerely,
/RA/
Marvin Mendonca, Senior Project Manager Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation
Massachusetts Institute of Technology Docket No. 50-20 cc:
City Manager City Hall Cambridge, MA 02139 Department of Environmental Protection One Winter Street Boston, MA 02108 Director Radiation Control Program Department of Public Health 90 Washington Street Dorchester, MA 02121 Nuclear Preparedness Manager Massachusetts Emergency Management Agency 40 Worcester Road Framingham, MA 01702-5399 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
ML073340485 OFFICE DPR/PRTA DPR/PRTA:LA DPR/PRTB:PM DPR/PRTA:BC NAME SPierce EHylton MMendonca DCollins DATE 11/30/07 11/30/07 11/30/07 11/30/07