{{#Wiki_filter:NC STATE UNIVERSITY No v ember 1, 2018 N ucl ea r Re ac tor Pro gra m Depa11111 e 111 of Nuclear En gi n eering nc.n cs u.e du/nrp U.S. Nuclea r Regulatory Commission Document Control Desk W as hington , DC Cam p us Box 7909 2500 S1 inso n Drive Ra l eigh, NC 27695-7909 919.5 1 5.7294 (vo i ce) 9!9.51 3.1 276 (fax) SUBJECT RESPONSE SUBMITTAL 1 TO THE REQUEST FOR ADDITIONAL INFORMATION FOR LICENSE RENEWAL APPLICATION FOR FACILITY OPERATING LICENSE R-120 FOR THE NORTH CAROLINA STATE UNIVERSITY PULSTAR RESEARCH REACTOR (EPID NO. L-2017-RNW-0026) License No. R-120 Docket No. 50-297 Please find en cl osed a partial response to th e Request for Add iti o nal I nformation fo r the License Renewal App lication (EP ID N O. L-2017-RNW-0026).
{{#Wiki_filter:Nuclea r Reactor Program                            Campus Box 7909 NC STATE                                 Depa11111e111 of Nuclear Engineering                2500 S1inson Drive Raleigh, NC 27695-7909
Responses to the Reques t for Addit i onal Informati on q ues t ions 1, 4, 5, 6(b), 6(c), a nd 6(d) a re be in g submi tted. The r espo n se to question 2, 3, an d 6(a) wi ll be sub mitt ed separately. If yo u have any questions regarding this amendment or require addit i onal information , please contact Andrew Cook at (919) 515-4602 or atcook@ncsu.edu. I declare u nder penalty of perjury that the forgoing is true and correct Executed on 1 November 2018. S incerely, Ay m an I. Hawari , Ph.D. Director , Nuclear Reactor Program North Carolina State University En closures: S ub m ittal 1 -Response to Req u est fo r Add itional Inform a ti on for LRA Attac hm ent 1 -NCSU PULSTAR Reactor Fi na n cia l Qua lifi ca ti ons Report 1-NOV-2018 Attac hm ent 2 -NCSU PU L STAR Reactor ROTRP 1-NOV-201 8 Attach m ent 3 -NCSU Burl ing ton Hall Researc h Reacto r Pip i ng Upgrade Fina l Engineer ing Report Attachment 4 -NCSU Ca l cu l ation No. NRP-98-0 1 Criticality Analysis for a 250 Fresh Pin Storage Rack Attachment 5 -Computation of De l ayed Fissio n Product Gamma Ray Dose Rates from NCSU PULST AR Reactor using a Monte Carlo Number Albedo Approach Attachment 6 -Monte Carlo Simulation of the Ga mm a Dose Rate in a Loss-of-Water Acc i dent at the North Carol in a Sta te Un i versity Research Reactor}}
                                        \\~vw. nc.ncsu.edu/nrp UNIVERSITY                                                                                    919.5 15.7294 (voice) 9!9.513. 1276 (fax)
November 1, 2018 U.S. Nuclear Regulatory Commission Document Control Desk Washington , DC SUBJECT         RESPONSE SUBMITTAL 1 TO THE REQUEST FOR ADDITIONAL INFORMATION FOR LICENSE RENEWAL APPLICATION FOR FACILITY OPERATING LICENSE R-120 FOR THE NORTH CAROLINA STATE UNIVERSITY PULSTAR RESEARCH REACTOR (EPID NO. L-2017-RNW-0026)
License No. R-120 Docket No. 50-297 Please find enclosed a partial response to th e Request for Additional Information for the License Renewal Application (EPID NO. L-2017-RNW-0026). Responses to the Request for Additional Information questions 1, 4, 5, 6(b) , 6(c) , and 6(d) are being submitted. The response to question 2, 3, and 6(a) will be submitted separately.
If you have any questions regarding this amendment or require additional information , please contact Andrew Cook at (919) 515-4602 or atcook@ncsu.edu .
I declare under penalty of perjury that the forgoing is true and correct Executed on 1 November 2018.
Sincerely, Ayman I. Hawari, Ph.D.
Director, Nuclear Reactor Program North Carolina State University
 
==Enclosures:==
 
Submittal 1 - Response to Request for Additional Information for LRA Attachment 1 - NCSU PULSTAR Reactor Financia l Qualifications Report 1-NOV-2018 Attachment 2 - NCSU PU LSTAR Reactor ROTRP 1-NOV-201 8 Attachment 3 - NCSU Burlington Hall Research Reactor Piping Upgrade Final Engineering Report Attachment 4 - NCSU Calculation No. NRP-98-01 Criticality Analysis for a 250 Fresh Pin Storage Rack Attachment 5 - Computation of Delayed Fission Product Gamma Ray Dose Rates from NCSU PULSTAR Reactor using a Monte Carlo Number Albedo Approach Attachment 6 - Monte Carlo Simulation of the Gamma Dose Rate in a Loss-of-Water Accident at the North Carolina State University Research Reactor}}

Latest revision as of 11:59, 20 October 2019

Response Submittal 1 to the Request for Additional Information for License Renewal Application for Facility Operating License R-120 for the North Carolina State University Pulstar Research Reactor
ML18312A303
Person / Time
Site: North Carolina State University
Issue date: 11/01/2018
From: Hawari A
North Carolina State University
To:
Document Control Desk, Office of Nuclear Reactor Regulation
Shared Package
ML18312A302 List:
References
EPID L-2017-RNW-0026
Download: ML18312A303 (1)


Text

Nuclea r Reactor Program Campus Box 7909 NC STATE Depa11111e111 of Nuclear Engineering 2500 S1inson Drive Raleigh, NC 27695-7909

\\~vw. nc.ncsu.edu/nrp UNIVERSITY 919.5 15.7294 (voice) 9!9.513. 1276 (fax)

November 1, 2018 U.S. Nuclear Regulatory Commission Document Control Desk Washington , DC SUBJECT RESPONSE SUBMITTAL 1 TO THE REQUEST FOR ADDITIONAL INFORMATION FOR LICENSE RENEWAL APPLICATION FOR FACILITY OPERATING LICENSE R-120 FOR THE NORTH CAROLINA STATE UNIVERSITY PULSTAR RESEARCH REACTOR (EPID NO. L-2017-RNW-0026)

License No. R-120 Docket No. 50-297 Please find enclosed a partial response to th e Request for Additional Information for the License Renewal Application (EPID NO. L-2017-RNW-0026). Responses to the Request for Additional Information questions 1, 4, 5, 6(b) , 6(c) , and 6(d) are being submitted. The response to question 2, 3, and 6(a) will be submitted separately.

If you have any questions regarding this amendment or require additional information , please contact Andrew Cook at (919) 515-4602 or atcook@ncsu.edu .

I declare under penalty of perjury that the forgoing is true and correct Executed on 1 November 2018.

Sincerely, Ayman I. Hawari, Ph.D.

Director, Nuclear Reactor Program North Carolina State University

Enclosures:

Submittal 1 - Response to Request for Additional Information for LRA Attachment 1 - NCSU PULSTAR Reactor Financia l Qualifications Report 1-NOV-2018 Attachment 2 - NCSU PU LSTAR Reactor ROTRP 1-NOV-201 8 Attachment 3 - NCSU Burlington Hall Research Reactor Piping Upgrade Final Engineering Report Attachment 4 - NCSU Calculation No. NRP-98-01 Criticality Analysis for a 250 Fresh Pin Storage Rack Attachment 5 - Computation of Delayed Fission Product Gamma Ray Dose Rates from NCSU PULSTAR Reactor using a Monte Carlo Number Albedo Approach Attachment 6 - Monte Carlo Simulation of the Gamma Dose Rate in a Loss-of-Water Accident at the North Carolina State University Research Reactor