MONTHYEARML18312A3101984-12-31031 December 1984 Computation of Delayed Fission Product Gamma Ray Dose Rates from NCSU Pulstar Reactor Using a Monte Carlo Number Albedo Approach - B. E. Hey Project stage: Other ML18312A3111985-05-0606 May 1985 Monte Carolo Simulation of the Gamma Dose Rate in a Loss-of-Water Accident at the North Carolina State University Research Reactor Project stage: Other ML18312A3091998-11-23023 November 1998 North Carolina State University - Calculation No. NRP-98-01: Criticality Analysis for a 250 Fresh Pin Storage Rack Project stage: Other ML18128A0472018-05-21021 May 2018 North Carolina State University Pulstar Research Reactor - Letter Request for Additional Information Regarding the Renewal of Facility Operating License No. R-120, Docket No. 50-297 Project stage: RAI ML18201A2002018-07-17017 July 2018 North Carolina State Univ., Response to Request for Additional Information Regarding Physical Security Plan Review for Renewal of Facility Operating Project stage: Response to RAI ML18268A3582018-10-18018 October 2018 North Carolina State University - Request for Additional Information License Renewal Application for Facility Operating License R-120 for the North Carolina State University Pulstar Research Reactor Project stage: RAI ML18312A3072018-11-0101 November 2018 North Carolina State University - Burlington Hall Research Reactor Piping Upgrade Final Engineering Report Project stage: Other ML18312A3062018-11-0101 November 2018 North Carolina State University - Reactor Operator Training and Requalification Program Project stage: Other ML18312A3052018-11-0101 November 2018 North Carolina State University - Financial Qualifications Report Project stage: Other ML18312A3042018-11-0101 November 2018 North Carolina State University - Response to Request for Additional Information Project stage: Response to RAI ML18312A3032018-11-0101 November 2018 Response Submittal 1 to the Request for Additional Information for License Renewal Application for Facility Operating License R-120 for the North Carolina State University Pulstar Research Reactor Project stage: Request ML18348A0132018-12-13013 December 2018 Request for Time Extension for the Request for Additional Information for License Renewal Application for Facility Operating License R-120 for the North Carolina State University Pulstar Research Reactor Project stage: Request ML19046A0332019-02-14014 February 2019 North Carolina State Univ., Safety Analysis for Assessing 2 MW Power Upgrade Project stage: Other ML19046A0302019-02-14014 February 2019 North Carolina State Univ., Response Submittal 2 to the Request for Additional Information for License Renewal Application Project stage: Request ML19046A0322019-02-14014 February 2019 North Carolina State Univ., Response to Request for Additional Information for License Renewal Application Project stage: Response to RAI ML19046A0312019-02-14014 February 2019 North Carolina State Univ., Response Submittal 2 to the Request for Additional Information for License Renewal Application Project stage: Request ML19221B5962019-06-21021 June 2019, 9 August 2019 North Carolina State University - Updated FSAR for License Renewal Application for Facility Operating License R-120 for Pulstar Research Reactor Project stage: Request ML19221B6022019-06-21021 June 2019 North Carolina State University, Safety Analysis in Support of Fueled Experiments for the NCSU Pulstar Reactor Project stage: Other ML19221B6012019-08-0909 August 2019 North Carolina State University, Updated Safety Analysis Report Project stage: Other ML19221B5972019-08-0909 August 2019 North Carolina State University - Updated FSAR for License Renewal Application for Facility Operating License R-120 for Pulstar Research Reactor Project stage: Request ML19269B7072019-09-25025 September 2019 Pulstar Reactor Appendix a Technical Specifications Project stage: Other ML19269B7052019-09-25025 September 2019 Updated Technical Specifications for License Renewal Application for Facility Operating License R-120 for the North Carolina State University Pulstar Research Reactor Project stage: Request ML19269B7062019-09-25025 September 2019 Updated Technical Specifications for License Renewal Application for Facility Operating License R-120 for the North Carolina State University Pulstar Research Reactor Project stage: Request ML19308C7172019-11-0505 November 2019 North Carolina State University; Regulatory Audit License Renewal and Power Increase of the Pulstar Research Reactor Project stage: Other ML20084K7132020-02-11011 February 2020 North Carolina State Univ., Reactor Thermal Power and Scram Setpoint Determination Project stage: Other ML20084K7162020-03-24024 March 2020 North Carolina State Univ., Safety Analysis in Support of Fueled Experiments for Pulstar Reactor Project stage: Other ML20084K7042020-03-24024 March 2020 North Carolina State Univ., Submittal of Updated Technical Specifications for License Renewal Application for Facility Operating License R-120 Project stage: Request ML20084K7082020-03-24024 March 2020 North Carolina State Univ., Appendix a for the Pulstar Reactor Project stage: Other ML20149K7592020-05-26026 May 2020 Updated FSAR for License Renewal Application for Facility Operating License R-120 for the North Carolina State University Pulstar Research Reactor Project stage: Request ML21210A4272021-08-23023 August 2021 North Carolina State University - Request for Additional Information License Renewal Application for Facility Operating License No. R-120 for the North Carolina State University Pulstar Research Reactor Project stage: RAI ML22033A2452022-02-0202 February 2022 North Carolina State Univ., Response to Request for Additional Information License Renewal Application Project stage: Response to RAI ML22159A2372022-06-0707 June 2022 Supplemental Information for Cladding Fuel Accident - Updated FSAR Section 13 for License Renewal Application for Facility Operating License R-120 for the North Carolina State University Pulstar Research Reactor Project stage: Supplement ML24040A1602024-01-25025 January 2024 Email; Cfleming, NCSU to Dhardesty, USNRC-NC State Pulstar License Renewal Approach from Nc State (Jan. 2024) Project stage: Other 2019-02-14
[Table View] |
Text
RESPONSE TO LRA RAI - SUBMITTAL 2 1
RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION FOR LICENSE RENEWAL APPLICATION FOR FACILITY OPERATING LICENSE NO. R-120 FOR THE NORTH CAROLINA STATE UNIVERSITY PULSTAR RESEARCH REACTOR (EPID NO. L-2017-RNW-0026)
SUBMITTAL 2 NORTH CAROLINA STATE UNIVERSITY LICENSE NO. R-120; DOCKET NO. 50-297 FEBRUARY 14TH, 2019
- 2.
Environmental Report (ADAMS Accession No: ML17088A836)
The NCSU LRA letter (ADAMS Accession No: ML17088A819) requested a power level increase of its Facility Operating License from 1.0 megawatt (MWt) to 2.6 MWt. Included in the LRA environmental report (ER), Section 4, Environmental Effects of Facility Operation, was the following statement: Operation of the reactor at 2 MW will not cause a significant increase in radiation levels or effluent. The NRC staff is not clear if the ER was performed at the proposed 2.0 MWt or 2.6 MWt power levels.
The regulations in 10 CFR 51.45(c) contain the requirements for an applicants ER, and states that an ER should contain sufficient data to aid the Commission in its development of an independent analysis.
Provide an updated ER with an environmental impact analysis that describes the operational changes associated with the proposed power level increase including effluents, doses, cooling demand, makeup water usage, and waste generation, including batch discharges to the sanitary sewer for operation at the proposed power level of 2.6 MWt, or justify why no changes are needed.
Note: The updated ER should properly bound the impacts commensurate with the proposed power level increase, including reference to a documented analysis methodology that identifies assumptions and accounts for any margins for instrument inaccuracies and measurement uncertainty in determining maximum power for the analysis.
RESPONSE
Per communication with NRC regarding the reduction in the peak cladding temperature limit and the addition of an oxidation limit, the Safety Analysis for Assessing 2 MW Power Upgrade for the NCSU PULSTAR Reactor report was revised resulting in a Limiting Safety System Setting of 2.0 MWt for the power level. Therefore, the 2.0 MWt used as the basis in the Environmental Report is correct and an update is not necessary.
RESPONSE TO LRA RAI - SUBMITTAL 2 2
- 3.
Safety Analysis Report (ADAMS Accession No: ML17201Q129)
The NCSU LRA requested a power level increase from 1.0 MWt to 2.6 MWt. Included in LRA SAR, Section 11, Radiation Protection Program and Waste Management, were radiation dose calculations that appear to assume operation at 2.0 MWt. The NRC staff is not clear if the dose calculations were performed at 2.0 MWt rather than the proposed 2.6 MWt power level.
The regulations in 10 CFR Part 20 require that doses to workers and members of the public be limited. LRA SAR Section 11 provided various dose calculations that would be necessary to make this determination (i.e., the concentrations of and the doses to workers/members of the public from any radiological effluents).
Provide clarification that the dose calculations provided in LRA SAR Section 11 comply with the limits in 10 CFR Part 20 for the proposed power level increase of 2.6 MWt or justify why no changes are needed.
RESPONSE
Per communication with NRC regarding the reduction in the peak cladding temperature limit and the addition of an oxidation limit, the Safety Analysis for Assessing 2 MW Power Upgrade for the NCSU PULSTAR Reactor report was revised resulting in a Limiting Safety System Setting of 2.0 MWt for the power level. Therefore, the 2.0 MWt used as the basis in Section 11 of the LRA SAR is correct.
RESPONSE TO LRA RAI - SUBMITTAL 2 3
- 6.
Supporting Information The regulations in 10 CFR 50.9, Completeness and accuracy of information, require that information provided to the Commission by a licensee shall be complete and accurate in all material respects.
The NRC staff, in its review of the NCSU LRA, finds that the following supporting information is necessary to continue its review:
- a. North Carolina State University PULSTAR Reactor, Safety Analysis for Assessing 2 MW Power Upgrade for the NCSU PULSTAR Reactor, March 2017.
Provide the following information or justify why the supporting information cannot or will not be provided.
RESPONSE
The document requested in 6(a) Safety Analysis for Assessing 2 MW Power Upgrade for the NCSU PULSTAR Reactor has been revised to reflect the cladding temperature limit of 1200 °C (2200 °F) along with a 17% cladding oxidation limit that was set based on discussion with the NRC via teleconference and followed up by an email on August 1, 2018.
The supporting information requested in (a) is included as Attachment 1 of this submittal.