MONTHYEARML18312A3101984-12-31031 December 1984 Computation of Delayed Fission Product Gamma Ray Dose Rates from NCSU Pulstar Reactor Using a Monte Carlo Number Albedo Approach - B. E. Hey Project stage: Other ML18312A3111985-05-0606 May 1985 Monte Carolo Simulation of the Gamma Dose Rate in a Loss-of-Water Accident at the North Carolina State University Research Reactor Project stage: Other ML18312A3091998-11-23023 November 1998 North Carolina State University - Calculation No. NRP-98-01: Criticality Analysis for a 250 Fresh Pin Storage Rack Project stage: Other ML18128A0472018-05-21021 May 2018 North Carolina State University Pulstar Research Reactor - Letter Request for Additional Information Regarding the Renewal of Facility Operating License No. R-120, Docket No. 50-297 Project stage: RAI ML18201A2002018-07-17017 July 2018 North Carolina State Univ., Response to Request for Additional Information Regarding Physical Security Plan Review for Renewal of Facility Operating Project stage: Response to RAI ML18268A3582018-10-18018 October 2018 North Carolina State University - Request for Additional Information License Renewal Application for Facility Operating License R-120 for the North Carolina State University Pulstar Research Reactor Project stage: RAI ML18312A3072018-11-0101 November 2018 North Carolina State University - Burlington Hall Research Reactor Piping Upgrade Final Engineering Report Project stage: Other ML18312A3062018-11-0101 November 2018 North Carolina State University - Reactor Operator Training and Requalification Program Project stage: Other ML18312A3052018-11-0101 November 2018 North Carolina State University - Financial Qualifications Report Project stage: Other ML18312A3042018-11-0101 November 2018 North Carolina State University - Response to Request for Additional Information Project stage: Response to RAI ML18312A3032018-11-0101 November 2018 Response Submittal 1 to the Request for Additional Information for License Renewal Application for Facility Operating License R-120 for the North Carolina State University Pulstar Research Reactor Project stage: Request ML18348A0132018-12-13013 December 2018 Request for Time Extension for the Request for Additional Information for License Renewal Application for Facility Operating License R-120 for the North Carolina State University Pulstar Research Reactor Project stage: Request ML19046A0332019-02-14014 February 2019 North Carolina State Univ., Safety Analysis for Assessing 2 MW Power Upgrade Project stage: Other ML19046A0302019-02-14014 February 2019 North Carolina State Univ., Response Submittal 2 to the Request for Additional Information for License Renewal Application Project stage: Request ML19046A0322019-02-14014 February 2019 North Carolina State Univ., Response to Request for Additional Information for License Renewal Application Project stage: Response to RAI ML19046A0312019-02-14014 February 2019 North Carolina State Univ., Response Submittal 2 to the Request for Additional Information for License Renewal Application Project stage: Request ML19221B5962019-06-21021 June 2019, 9 August 2019 North Carolina State University - Updated FSAR for License Renewal Application for Facility Operating License R-120 for Pulstar Research Reactor Project stage: Request ML19221B6022019-06-21021 June 2019 North Carolina State University, Safety Analysis in Support of Fueled Experiments for the NCSU Pulstar Reactor Project stage: Other ML19221B6012019-08-0909 August 2019 North Carolina State University, Updated Safety Analysis Report Project stage: Other ML19221B5972019-08-0909 August 2019 North Carolina State University - Updated FSAR for License Renewal Application for Facility Operating License R-120 for Pulstar Research Reactor Project stage: Request ML19269B7072019-09-25025 September 2019 Pulstar Reactor Appendix a Technical Specifications Project stage: Other ML19269B7052019-09-25025 September 2019 Updated Technical Specifications for License Renewal Application for Facility Operating License R-120 for the North Carolina State University Pulstar Research Reactor Project stage: Request ML19269B7062019-09-25025 September 2019 Updated Technical Specifications for License Renewal Application for Facility Operating License R-120 for the North Carolina State University Pulstar Research Reactor Project stage: Request ML19308C7172019-11-0505 November 2019 North Carolina State University; Regulatory Audit License Renewal and Power Increase of the Pulstar Research Reactor Project stage: Other ML20084K7132020-02-11011 February 2020 North Carolina State Univ., Reactor Thermal Power and Scram Setpoint Determination Project stage: Other ML20084K7162020-03-24024 March 2020 North Carolina State Univ., Safety Analysis in Support of Fueled Experiments for Pulstar Reactor Project stage: Other ML20084K7042020-03-24024 March 2020 North Carolina State Univ., Submittal of Updated Technical Specifications for License Renewal Application for Facility Operating License R-120 Project stage: Request ML20084K7082020-03-24024 March 2020 North Carolina State Univ., Appendix a for the Pulstar Reactor Project stage: Other ML20149K7592020-05-26026 May 2020 Updated FSAR for License Renewal Application for Facility Operating License R-120 for the North Carolina State University Pulstar Research Reactor Project stage: Request ML21210A4272021-08-23023 August 2021 North Carolina State University - Request for Additional Information License Renewal Application for Facility Operating License No. R-120 for the North Carolina State University Pulstar Research Reactor Project stage: RAI ML22033A2452022-02-0202 February 2022 North Carolina State Univ., Response to Request for Additional Information License Renewal Application Project stage: Response to RAI ML22159A2372022-06-0707 June 2022 Supplemental Information for Cladding Fuel Accident - Updated FSAR Section 13 for License Renewal Application for Facility Operating License R-120 for the North Carolina State University Pulstar Research Reactor Project stage: Supplement ML24040A1602024-01-25025 January 2024 Email; Cfleming, NCSU to Dhardesty, USNRC-NC State Pulstar License Renewal Approach from Nc State (Jan. 2024) Project stage: Other 2019-02-14
[Table View] |
Text
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION May 21, 2018 Dr. Ayman I. Hawari, Director Nuclear Reactor Program Department of Nuclear Engineering North Carolina State University 2500 Stinson Drive Raleigh, NC 27695-7909
SUBJECT:
NORTH CAROLINA STATE UNIVERSITY - REQUEST FOR ADDITIONAL INFORMATION RE: PHYSICAL SECURITY PLAN REVIEW FOR RENEWAL OF FACILITY OPERATING LICENSE R-120 FOR THE NORTH CAROLINA STATE UNIVERSITY PULSTAR RESEARCH REACTOR (EPID NO. L-2017-RNW-0026)
Dear Dr. Hawari:
The U.S. Nuclear Regulatory Commission (NRC) staff is continuing its review of the North Carolina State University (NCSU) PULSTAR Research Reactor license renewal application dated March 29, 2017 (Agencywide Documents Access and Management System Accession No. ML17201Q129). The license renewal review includes NRC staffs review of Revision 15 of the physical security plan (PSP) for the protection of special nuclear material for the NCSU PULSTAR Research Reactor, dated March 30, 2017, submitted under Title 10 of the Code of Federal Regulations (10 CFR) Part 73, Physical Protection of Plants and Materials, and the additional security measures identified in the NCSU Compensatory Measures Implementation Plan, dated March 18, 2004, that were incorporated into the PSP as stated in the NCSU letter dated August 5, 2009. In the course of reviewing the NCSU PSP, the NRC staff has identified that additional information is needed to complete its review. It is requested that NCSU provide responses to the enclosed request for additional information within 60 days from the date of this letter.
In accordance with 10 CFR 50.30(b), Oath or affirmation, NCSU must execute its response in a signed original document under oath or affirmation. The response must be submitted in accordance with 10 CFR 50.4, Written communications. Information included in your response that is considered sensitive or proprietary, that you seek to have withheld from the public, must be marked in accordance with 10 CFR 2.390, Public inspections, exemptions, requests for withholding. Any safeguards information included in your response should be submitted in accordance with 10 CFR 73.21, Protection of Safeguards Information:
Performance Requirements. Following receipt of the additional information, the NRC staff will continue its evaluation of the renewal request application.
Enclosure transmitted herewith contains Official Use Only -
Security-Related Information. When separated from Enclosure, this transmittal document is decontrolled.
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION If you have any questions, or need additional time to respond to this request, contact me at (301) 415-3724, or by electronic mail at Duane.Hardesty@nrc.gov.
Sincerely,
/RA by Steven Lynch for/
Duane A. Hardesty, Senior Project Manager Research and Test Reactors Licensing Branch Division of Licensing Projects Office of Nuclear Reactor Regulation Docket No. 50-297 License No. R-120
Enclosure:
As stated cc: w/o enclosure: See next page
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION North Carolina State University Docket No. 50-297 cc:
Office of Intergovernmental Relations 116 West Jones Street Raleigh, NC 27603 Dr. Kostadin Ivanov, Head Department of Nuclear Engineering North Carolina State University Campus Box 7909 Raleigh, NC 27695-7909 W. Lee Cox, Section Chief Department of Health and Human Services Division of Health Service Regulation Radiation Protection Section 1645 Mail Service Center Raleigh, NC 27699-1645 Dr. Louis Martin-Vega, Dean College of Engineering North Carolina State University 113 Page Hall Campus Box 7901 Raleigh, NC 27695-7901 Test, Research and Training Reactor Newsletter P.O. Box 118300 University of Florida Gainesville, FL 32611 Gerald Wicks, CHP Reactor Health Physicist Department of Nuclear Engineering North Carolina State University Campus Box 7909 2500 Stinson Drive Raleigh, NC 27695-7909 Andrew T. Cook Manager of Engineering and Operations Nuclear Reactor Program Department of Nuclear Engineering North Carolina State University Campus Box 7909 2500 Stinson Drive Raleigh, NC 27695-7909
ML18128A047
- concurrence via email NRR-088 OFFICE NRR/DLP/PRLB/PM NRR/DLP/PRLB/LA*
NRR/DLP/PRLB/ABC NRR/DLP/PRLB/PM NAME DHardesty NParker SLynch DHardesty (SLynch for)
DATE 5/10/2018 5/10/2018 5/21/2018 5/21/2018