September 25, 2020 US Nuclear Regulatory Commission Document Control Desk Washington, DC 20555
SUBJECT:
REPLY TO A NOTICE OF VIOLATION; 50-120/2020-201-01 LICENSE NO. R-120 DOCKET NO. 50-297 Enclosed please find supplemental data for the 2017 Annual Operating Report. This data is being provided as stated in our letter dated August 31, 2020 in response to Notice of Violation 50-120/2020-201-01.
If you have any questions regarding the above information, please contact Scott Lassell at 919-515-3347 (salassel@ncsu.edu).
I declare under penalty of perjury that the forgoing is true and correct. Executed on 25 September 2020.
Sincerely, Ayman I. Hawari, Ph.D.
Director, Nuclear Reactor Program
Enclosures:
Supplement to 2017 Annual Operating Report Nuclear Reactor Program Department of Nuclear Engineering www.ne.ncsu.edu/nrp Campus Box 7909 2500 Stinson Drive Raleigh, NC 27695-7909 919.515.7294 (voice) 919.513.1276 (fax)
Supplemental Data for 2017 Annual Operating Report, Section 6.7.4.f Liquid Waste iv.
Releases to Unrestricted Areas An unaccounted loss of water from the reactor coolant system (RCS) occurred during the reporting period (calendar year). The RCS water loss is measured every work day and occurred at variable rates over the year. RCS water was not observed in surface locations or storm sewer locations outside the reactor building. Therefore, the unaccounted RCS water was assumed to be continuously released to grounds beneath the surface on the reactor site at the measured RCS loss rates over the year.
The average annual concentrations of radioactive material in the RCS water did not exceed values given in 10 CFR Part 20 Appendix B Table 2 Column 2 for liquid effluents. Therefore, no additional dilution was needed. Detected radionuclides were tritium and activation products associated with reactor operation. No fission products were detected. No tritium or activation products were detected in environmental samples (refer to Section 6.7.4.i).
RCS water activity and volume assumed to be released to unrestricted areas is shown below:
Period Total Ci Tritium Ci Volume Liters 01 JAN - 31 MAR 2017 6,906 6,852 27,096 1 APR - 30 JUN 2017 6,025 5,973 31,139 1 JUL - 30 SEP 2017 7,637 7,591 36,551 1 OCT - 31 DEC 2017 9,494 9,338 40,864 CALENDAR YEAR 2017 30,062 29,754 135,650 10a