Line 1: |
Line 1: |
| #REDIRECT [[ML21090A250]] | | {{Adams |
| | | number = ML21090A249 |
| | | issue date = 03/31/2021 |
| | | title = ECCS Evaluation Model Revisions |
| | | author name = Bianco F |
| | | author affiliation = Ameren Missouri, Union Electric Co |
| | | addressee name = |
| | | addressee affiliation = NRC/Document Control Desk, NRC/NRR |
| | | docket = 05000483 |
| | | license number = NPF-030 |
| | | contact person = |
| | | case reference number = ULNRC-06645 |
| | | package number = ML21090A248 |
| | | document type = Letter type:ULNRC |
| | | page count = 4 |
| | }} |
| | |
| | =Text= |
| | {{#Wiki_filter:Callaway Plant MISSOURI March 31, 2021 ULNRC-06645 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-000 1 10 CfR 50.46 Ladies and Gentlemen: |
| | DOCKET NUMBER 50-483 CALLAWAY PLANT UNIT 1 UNION ELECTRIC CO. |
| | RENEWED FACILITY OPERATING LICENSE NPF-30 ECCS EVALUATION MODEL REVISIONS Ameren Missouri hereby submits the annual report required per 10 CFR 50.46(a)(3) for Callaway Plant. Attachment 1 to this letter describes those changes to the Westinghouse ECCS Large Break and Small Break Loss of Coolant Accident (LOCA) Evaluation Models that have been implemented for Callaway during the time period from March 2020 to March 2021 Attachment 2 provides an ECCS Evaluation Model Margin Assessment which accounts for all peak cladding temperature (PCi) changes resulting from the resolution of prior issues as they apply to Callaway. No new PCi penalties are included in these attachments. |
| | References 1 through 15 (listed on page 2 ofthis letter) provided annual 10 CFR 50.46 reports that were issued after the LOCA analyses were revised to reflect the installation ofthe replacement steam generators in 2005. The PCT values determined in the Large Break and Small Break LOCA analyses of record, when combined with all PCT margin allocations, remain below the 2200°F regulatory limit. |
| | However, in March 2014, Ameren Missouri was informed by Westinghouse that the absolute magnitude ofthe Large Break Loss ofCoolant Accident (LBLOCA) penalty assessments that have accumulated since the current analysis of record (replacement steam generator analysis approved in Callaway License Amendment 168) exceeded 50°F. As such, Reference 9 was submitted within the requirements of 10 CFR 50.46(a)(3)(ii), and contains a commitment to reanalyze the Large Break and Small Break Loss of Coolant Accidents using the NRC-approved version of WCAP-16996-P, Realistic LOCA Evaluation Methodology Applied to the Full Spectrum ofBreak Sizes (FULL SPECTRUM LOCA Methodology). This reanalysis will be completed on a schedule to be determined as part ofthe 10 CFR 50.46c rulemaking process. |
| | 8315 County Road 459 : Steedman, MO 65077 : AmerenMissouri.com |
| | |
| | ULNRC-06645 March 31, 2021 Page 2 of 4 This letter does not contain new commitments. for any questions on this report, please contact Mr. |
| | Tom Elwood at (314) 225-1905. |
| | ianco Senior Director, Nuclear Operations JLB/mlp |
| | |
| | ==References:== |
| | : 1) ULNRC-05260 dated 3-9-06 |
| | : 2) ULNRC-05378 dated 3-7-07 |
| | : 3) ULNRC-05475 dated 3-4-08 |
| | : 4) ULNRC-05600 dated 3-4-09 |
| | : 5) ULNRC-05683 dated 3-1-10 |
| | : 6) ULNRC-05769 dated 3-1-11 |
| | : 7) ULNRC-05840 dated 3-1-12 |
| | : 8) ULNRC-05968 dated 3-6-13 |
| | : 9) ULNRC-06098 dated 3-25-14 |
| | : 10) ULNRC-06203 dated 3-31-15 |
| | : 11) ULNRC-06292 dated 3-30-16 |
| | : 12) ULNRC-06361 dated 3-30-17 |
| | : 13) ULNRC-06428 dated 3-29-18 |
| | : 14) ULNRC-06497 dated 3-28-19 |
| | : 15) ULNRC-06571 dated 3-31-20 Attachments: |
| | 1 Changes to the Westinghouse ECCS Evaluation Model and PCT Penalty Assessments |
| | : 2. ECCS Evaluation Model Margin Assessment for Callaway |
| | ::::::::::::::::::::::::::.:::::::..2. ::::::::::: .::::::::::: .2::::: .::::::::: .:::: .::::::::::::::::::::::::::::::::: .:::: .::::::::::::::::::::. ::::::::: .:::: .2:::::. |
| | |
| | ULNRC-06645 March 31, 2021 Page 3 of 4 cc: Mr. Scoff A. Morris Regional Administrator U. S. Nuclear Regulatory Commission Region IV 1600 East Lamar Boulevard Arlington, TX 76011-4511 Senior Resident Inspector Callaway Resident Office U.S Nuclear Regulatory Commission |
| | $201 NRC Road Steedman, MO 65077 Mr. M. Chawla Project Manager, Callaway Plant Office ofNuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop 0$B1A Washington, DC 20555-0001 |
| | |
| | ULNRC-06645 March 31, 2021 Page 4 of 4 Index and send hardcopy to QA file A160.0761 Hardcopy: |
| | Certrec Corporation 6500 West Freeway, Suite 400 Fort Worth, TX 76116 (Certrec receives ALL attachments as long as they are non-safeguards and may be publicly disclosed.) |
| | Electronic distribution for the following can be made via Other Situations ULNRC Distribution: |
| | F. M. Diya B. L. Cox F. J. Bianco S. P. Banker S. J. Meyer R. C. Wink T. B. Elwood NSRB Secretary STARS Regulatory Affairs Mr. Jay Silberg (Pillsbury Winthrop Shaw Pittman LLP) |
| | Ms. Kathleen McNelis (Public Service Commission) |
| | Ms. Claire Eubanks (Public Service Commission)}} |
|
---|
Category:Letter type:ULNRC
MONTHYEARULNRC-06901, Concurrent Inoperability of Control Room Air Conditioning System Train and Opposite Train Emergency Diesel Generator Results in Condition Prohibited by Technical Specifications Limiting (Letter)2024-10-0101 October 2024 Concurrent Inoperability of Control Room Air Conditioning System Train and Opposite Train Emergency Diesel Generator Results in Condition Prohibited by Technical Specifications Limiting (Letter) ULNRC-06892, Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Canister HGMPC00062024-06-26026 June 2024 Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Canister HGMPC0006 ULNRC-06891, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC00052024-06-26026 June 2024 Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC0005 ULNRC-06886, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC00042024-06-12012 June 2024 Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC0004 ULNRC-06885, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC00032024-06-12012 June 2024 Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC0003 ULNRC-06884, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC00022024-06-12012 June 2024 Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC0002 ULNRC-06882, Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Canister HGMPC00122024-05-16016 May 2024 Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Canister HGMPC0012 ULNRC-06877, Final Safety Analysis Report Revision OL-27 and Technical Specification Bases Revision 252024-05-0606 May 2024 Final Safety Analysis Report Revision OL-27 and Technical Specification Bases Revision 25 ULNRC-06856, CFR 50.59 and 10 CFR 72.48 Summary Report2024-05-0101 May 2024 CFR 50.59 and 10 CFR 72.48 Summary Report ULNRC-06869, Submittal of Callaway, Unit 1, 2023 Annual Radiological Environmental Operating Report2024-04-30030 April 2024 Submittal of Callaway, Unit 1, 2023 Annual Radiological Environmental Operating Report ULNRC-06876, Registration of Dry Spent Fuel Storage Canister HGMPC00102024-04-25025 April 2024 Registration of Dry Spent Fuel Storage Canister HGMPC0010 ULNRC-06866, Submittal of Cycle 26 Commitment Change Summary Report2024-04-17017 April 2024 Submittal of Cycle 26 Commitment Change Summary Report ULNRC-06871, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC00072024-04-17017 April 2024 Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC0007 ULNRC-06872, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC00082024-04-17017 April 2024 Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC0008 ULNRC-06863, Submittal of Annual Exposure Report for 20232024-03-20020 March 2024 Submittal of Annual Exposure Report for 2023 ULNRC-06852, Owners Activity Reports (OAR-1 Forms) for Cycle/Refuel 262024-03-0505 March 2024 Owners Activity Reports (OAR-1 Forms) for Cycle/Refuel 26 ULNRC-06858, Completion of License Renewal Activities Prior to Entering the Period of Extended Operation2024-02-21021 February 2024 Completion of License Renewal Activities Prior to Entering the Period of Extended Operation ULNRC-06853, Submittal of 2023 Fitness for Duty Performance Data Per Per 10 CFR 26.7172024-01-29029 January 2024 Submittal of 2023 Fitness for Duty Performance Data Per Per 10 CFR 26.717 ULNRC-06847, Supplement to Relief Request from Requirements of ASME BPV Code, Section XI, Subsection Iwl Regarding Examination and Testing of the Unbonded Post-Tensioning System (Relief Request C3R-01)2023-12-21021 December 2023 Supplement to Relief Request from Requirements of ASME BPV Code, Section XI, Subsection Iwl Regarding Examination and Testing of the Unbonded Post-Tensioning System (Relief Request C3R-01) ULNRC-06844, Request for Exemption from Specific Requirements in 2023 Security Rule, Enhanced Weapons, Firearms Background Checks, and Security Event Notification2023-12-0707 December 2023 Request for Exemption from Specific Requirements in 2023 Security Rule, Enhanced Weapons, Firearms Background Checks, and Security Event Notification ULNRC-06827, Supplement to License Amendment Request Regarding Support System Requirements for Residual Heat Removal and Control Room Air Conditioning Systems Under Technical Specifications 3.4.8, 3.7.11, and 3.9.6 (LDCN 22-0029)2023-11-20020 November 2023 Supplement to License Amendment Request Regarding Support System Requirements for Residual Heat Removal and Control Room Air Conditioning Systems Under Technical Specifications 3.4.8, 3.7.11, and 3.9.6 (LDCN 22-0029) ULNRC-06824, Response to Request for Additional Information Regarding Operating Quality Assurance Manual (Oqam) Revision 36A2023-08-17017 August 2023 Response to Request for Additional Information Regarding Operating Quality Assurance Manual (Oqam) Revision 36A ULNRC-06223, Minor Correction to License Amendment Request to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak Rate Test Frequencies (LDCN 2020-0004)2023-07-25025 July 2023 Minor Correction to License Amendment Request to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak Rate Test Frequencies (LDCN 2020-0004) ULNRC-06799, Submittal of Licensee Event Report 2022-003-01, Class 1E Electrical Air Conditioning System Thermal Expansion Valve Failure Resulted in Condition Prohibited by Technical Specifications2023-07-13013 July 2023 Submittal of Licensee Event Report 2022-003-01, Class 1E Electrical Air Conditioning System Thermal Expansion Valve Failure Resulted in Condition Prohibited by Technical Specifications ULNRC-06821, Post-Audit Follow-Up Information in Support of Callaways License Amendment Request and Proposed Exemption to Allow Use of Framatome Gaia Fuel (LDCN 22-0002) (EPID L-2022-LLA-0150 and EPID L-2022-LLE-00301)2023-06-21021 June 2023 Post-Audit Follow-Up Information in Support of Callaways License Amendment Request and Proposed Exemption to Allow Use of Framatome Gaia Fuel (LDCN 22-0002) (EPID L-2022-LLA-0150 and EPID L-2022-LLE-00301) ULNRC-06818, Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak Rate .2023-06-0505 June 2023 Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak Rate . ULNRC-06815, Request for NRC Approval of Operating Quality Assurance Manual, Revision 36a2023-06-0505 June 2023 Request for NRC Approval of Operating Quality Assurance Manual, Revision 36a ULNRC-06816, Withdrawal of Previously Submitted Enclosures Regarding License Amendment Request for Adoption of Alternative Source Term and Revision of Technical Specifications (LDCN 21-0015)2023-05-0909 May 2023 Withdrawal of Previously Submitted Enclosures Regarding License Amendment Request for Adoption of Alternative Source Term and Revision of Technical Specifications (LDCN 21-0015) ULNRC-06807, Submittal of Single Positive Test Forms2023-04-0303 April 2023 Submittal of Single Positive Test Forms ULNRC-06801, CFR 50.46 Annual Report Regarding ECCS Evaluation Model Revisions2023-03-30030 March 2023 CFR 50.46 Annual Report Regarding ECCS Evaluation Model Revisions ULNRC-06798, Submittal of Status of Plant Decommissioning Funding and ISFSI Decommissioning Funding Plan2023-03-30030 March 2023 Submittal of Status of Plant Decommissioning Funding and ISFSI Decommissioning Funding Plan ULNRC-06803, Submittal of Response to Request for Additional Information Regarding Results of Steam Generator Tube In-Service Inspection2023-03-29029 March 2023 Submittal of Response to Request for Additional Information Regarding Results of Steam Generator Tube In-Service Inspection ULNRC-06805, Transmittal of Special Report 2023-02 Non-Functionality of Containment Hydrogen Analyzer Channel for Greater than 30 Days2023-03-21021 March 2023 Transmittal of Special Report 2023-02 Non-Functionality of Containment Hydrogen Analyzer Channel for Greater than 30 Days ULNRC-06802, Special Report 2023-01 (PAM Report); Non-Functionality of a Post-Accident Monitoring Instrument2023-03-0909 March 2023 Special Report 2023-01 (PAM Report); Non-Functionality of a Post-Accident Monitoring Instrument ULNRC-06795, Submittal of Fitness for Duty Reports for 2022, Including Single Positive Test Forms2023-01-24024 January 2023 Submittal of Fitness for Duty Reports for 2022, Including Single Positive Test Forms ULNRC-06794, Submittal of Fitness for Duty Program Data for 20222023-01-24024 January 2023 Submittal of Fitness for Duty Program Data for 2022 ULNRC-06787, Response to Request for Additional Information Regarding License Amendment Request for Adoption of Alternate Source Term and Revision of Technical Specifications (LDCN 21-0015)2022-12-0808 December 2022 Response to Request for Additional Information Regarding License Amendment Request for Adoption of Alternate Source Term and Revision of Technical Specifications (LDCN 21-0015) ULNRC-06780, Additional Supplement to License Amendment Request to Adopt TSTF-439 and TSTF-505, LDCN 20-0072022-11-30030 November 2022 Additional Supplement to License Amendment Request to Adopt TSTF-439 and TSTF-505, LDCN 20-007 ULNRC-06772, 10 CFR 50.59 and 10 CFR 72.48 Summary Report2022-11-23023 November 2022 10 CFR 50.59 and 10 CFR 72.48 Summary Report ULNRC-06779, ULNRC-06779: Contesting of Green NCV 05000483/2022010-03, Failure to Perform Required Inservice Testing of Residual Heat Removal Heat Exchanger Pneumatically (Air) Operated Outlet and Bypass Valves2022-11-14014 November 2022 ULNRC-06779: Contesting of Green NCV 05000483/2022010-03, Failure to Perform Required Inservice Testing of Residual Heat Removal Heat Exchanger Pneumatically (Air) Operated Outlet and Bypass Valves ULNRC-06773, Results of Steam Generator Tube In-Service Inspection2022-11-0101 November 2022 Results of Steam Generator Tube In-Service Inspection ULNRC-06775, Submittal of Non-Functionality of Loose-Part Detection System Channel for Greater than 30 Days2022-10-27027 October 2022 Submittal of Non-Functionality of Loose-Part Detection System Channel for Greater than 30 Days ULNRC-06771, Correction to Application to Revise Technical Specifications to Adopt TSTF 577, Revised Frequencies for Steam Generator Tube Inspections (LDCN 21-0013)2022-10-25025 October 2022 Correction to Application to Revise Technical Specifications to Adopt TSTF 577, Revised Frequencies for Steam Generator Tube Inspections (LDCN 21-0013) ULNRC-06770, Cycle 25 Commitment Change Summary Report2022-10-19019 October 2022 Cycle 25 Commitment Change Summary Report ULNRC-06763, Supplement to Application to Revise Technical Specifications to Adopt TSTF 577, Revised Frequencies for Steam Generator Tube Inspection (LDCN 21-0013)2022-09-0101 September 2022 Supplement to Application to Revise Technical Specifications to Adopt TSTF 577, Revised Frequencies for Steam Generator Tube Inspection (LDCN 21-0013) ULNRC-06758, Union Electric Co. - Renewed Facility Operating License NPF-30, Withdrawal of License Amendment Request and Exemption Request Regarding Transition to Framatome Fuel (LDCN 22-0002)2022-08-0404 August 2022 Union Electric Co. - Renewed Facility Operating License NPF-30, Withdrawal of License Amendment Request and Exemption Request Regarding Transition to Framatome Fuel (LDCN 22-0002) ULNRC-06755, Enclosure 2: Ameren Missouri Verification Ofagreement Letters with State and EPZ Counties for Proposed Revision to Radiological Emergency Response Plan Regarding Response and Notification Goals2022-07-13013 July 2022 Enclosure 2: Ameren Missouri Verification Ofagreement Letters with State and EPZ Counties for Proposed Revision to Radiological Emergency Response Plan Regarding Response and Notification Goals ULNRC-06754, Response to Request for Additional Information Regarding Licensee Amendment Request for Adoption of Alternate Source Term and Revision of Technical Specifications2022-07-0505 July 2022 Response to Request for Additional Information Regarding Licensee Amendment Request for Adoption of Alternate Source Term and Revision of Technical Specifications ULNRC-06739, Post-Audit Supplement to License Amendment Request to Adopt TSTF-439 and TSTF-505 (LDCN 20-0007)2022-06-30030 June 2022 Post-Audit Supplement to License Amendment Request to Adopt TSTF-439 and TSTF-505 (LDCN 20-0007) ULNRC-06752, Evacuation Time Estimates Report2022-06-27027 June 2022 Evacuation Time Estimates Report 2024-06-26
[Table view] |
Text
Callaway Plant MISSOURI March 31, 2021 ULNRC-06645 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-000 1 10 CfR 50.46 Ladies and Gentlemen:
DOCKET NUMBER 50-483 CALLAWAY PLANT UNIT 1 UNION ELECTRIC CO.
RENEWED FACILITY OPERATING LICENSE NPF-30 ECCS EVALUATION MODEL REVISIONS Ameren Missouri hereby submits the annual report required per 10 CFR 50.46(a)(3) for Callaway Plant. Attachment 1 to this letter describes those changes to the Westinghouse ECCS Large Break and Small Break Loss of Coolant Accident (LOCA) Evaluation Models that have been implemented for Callaway during the time period from March 2020 to March 2021 Attachment 2 provides an ECCS Evaluation Model Margin Assessment which accounts for all peak cladding temperature (PCi) changes resulting from the resolution of prior issues as they apply to Callaway. No new PCi penalties are included in these attachments.
References 1 through 15 (listed on page 2 ofthis letter) provided annual 10 CFR 50.46 reports that were issued after the LOCA analyses were revised to reflect the installation ofthe replacement steam generators in 2005. The PCT values determined in the Large Break and Small Break LOCA analyses of record, when combined with all PCT margin allocations, remain below the 2200°F regulatory limit.
However, in March 2014, Ameren Missouri was informed by Westinghouse that the absolute magnitude ofthe Large Break Loss ofCoolant Accident (LBLOCA) penalty assessments that have accumulated since the current analysis of record (replacement steam generator analysis approved in Callaway License Amendment 168) exceeded 50°F. As such, Reference 9 was submitted within the requirements of 10 CFR 50.46(a)(3)(ii), and contains a commitment to reanalyze the Large Break and Small Break Loss of Coolant Accidents using the NRC-approved version of WCAP-16996-P, Realistic LOCA Evaluation Methodology Applied to the Full Spectrum ofBreak Sizes (FULL SPECTRUM LOCA Methodology). This reanalysis will be completed on a schedule to be determined as part ofthe 10 CFR 50.46c rulemaking process.
8315 County Road 459 : Steedman, MO 65077 : AmerenMissouri.com
ULNRC-06645 March 31, 2021 Page 2 of 4 This letter does not contain new commitments. for any questions on this report, please contact Mr.
Tom Elwood at (314) 225-1905.
ianco Senior Director, Nuclear Operations JLB/mlp
References:
- 1) ULNRC-05260 dated 3-9-06
- 2) ULNRC-05378 dated 3-7-07
- 3) ULNRC-05475 dated 3-4-08
- 4) ULNRC-05600 dated 3-4-09
- 5) ULNRC-05683 dated 3-1-10
- 6) ULNRC-05769 dated 3-1-11
- 7) ULNRC-05840 dated 3-1-12
- 8) ULNRC-05968 dated 3-6-13
- 9) ULNRC-06098 dated 3-25-14
- 10) ULNRC-06203 dated 3-31-15
- 11) ULNRC-06292 dated 3-30-16
- 12) ULNRC-06361 dated 3-30-17
- 13) ULNRC-06428 dated 3-29-18
- 14) ULNRC-06497 dated 3-28-19
- 15) ULNRC-06571 dated 3-31-20 Attachments:
1 Changes to the Westinghouse ECCS Evaluation Model and PCT Penalty Assessments
- 2. ECCS Evaluation Model Margin Assessment for Callaway
- .:::::::..2. ::::::::::: .::::::::::: .2::::: .::::::::: .:::: .::::::::::::::::::::::::::::::::: .:::: .::::::::::::::::::::. ::::::::: .:::: .2:::::.
ULNRC-06645 March 31, 2021 Page 3 of 4 cc: Mr. Scoff A. Morris Regional Administrator U. S. Nuclear Regulatory Commission Region IV 1600 East Lamar Boulevard Arlington, TX 76011-4511 Senior Resident Inspector Callaway Resident Office U.S Nuclear Regulatory Commission
$201 NRC Road Steedman, MO 65077 Mr. M. Chawla Project Manager, Callaway Plant Office ofNuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop 0$B1A Washington, DC 20555-0001
ULNRC-06645 March 31, 2021 Page 4 of 4 Index and send hardcopy to QA file A160.0761 Hardcopy:
Certrec Corporation 6500 West Freeway, Suite 400 Fort Worth, TX 76116 (Certrec receives ALL attachments as long as they are non-safeguards and may be publicly disclosed.)
Electronic distribution for the following can be made via Other Situations ULNRC Distribution:
F. M. Diya B. L. Cox F. J. Bianco S. P. Banker S. J. Meyer R. C. Wink T. B. Elwood NSRB Secretary STARS Regulatory Affairs Mr. Jay Silberg (Pillsbury Winthrop Shaw Pittman LLP)
Ms. Kathleen McNelis (Public Service Commission)
Ms. Claire Eubanks (Public Service Commission)