{{#Wiki_filter:Code of Federal Regulations
{{#Wiki_filter:March 06, 2019 Mr. Peter Hastings Vice President, Regulatory Affairs and Quality Kairos Power LLC 707 W Tower Ave Alameda, CA 94501


     /RA/}}
==SUBJECT:==
ACCEPTANCE FOR REVIEW OF KAIROS POWER LLC, PRINCIPAL DESIGN CRITERIA FOR THE KAIROS POWER FLUORIDE SALT-COOLED, HIGH TEMPERATURE REACTOR TOPICAL REPORT (CAC NO. 000431)
 
==Dear Mr. Hastings:==
 
By letter dated December 21, 2018, Kairos Power LLC (Kairos) submitted for U.S. Nuclear Regulatory Commission (NRC) staff review, Principal Design Criteria for the Kairos Power Fluoride Salt-Cooled, High Temperature Reactor Topical Report, (Agencywide Documents Access and Management System Accession No. ML18355B067). The NRC staff has performed an acceptance review of the Principal Design Criteria for the Kairos Power Fluoride Salt-Cooled, High Temperature Reactor Topical Report, and found that the material presented provides the technical information in sufficient detail to enable the staff to complete a detailed technical review. The NRC staff expects to issue its request for additional information (RAI) by April 30, 2019, and issue its draft safety evaluation by September 30, 2019. A portion of the basis for completion of the evaluation on this schedule is Kairos response to the RAI within 30 days of your receipt. The NRC staff estimates that the review will require approximately 600 staff hours, including project management time.
The Advisory Committee for Reactor Safeguards (ACRS) will be notified of the, Principal Design Criteria for the Kairos Power Fluoride Salt-Cooled, High Temperature Reactor Topical Report, review and may choose to discuss the report at an ACRS meeting. This may result in a delay in issuing the final safety evaluation to Kairos.
The review schedule milestones and estimated review costs were discussed and agreed upon during a meeting between yourself and Stewart Magruder, Senior Project Manager, Advanced Reactor Policy Branch, NRC on February 25, 2019.
Section 170.21 of Title 10 of the Code of Federal Regulations requires that topical reports are subject to fees based on the full cost of the review. You did not request a fee waiver; therefore, NRC staff hours will be billed accordingly.
 
P. Hastings                                      2 If you have questions regarding this matter, please contact Stewart Magruder at (301) 348-5766 or Stewart.Magruder@NRC.gov.
Sincerely,
                                                /RA/
John P. Segala, Chief Advanced Reactor and Policy Branch Division of Safety Systems, Risk Assessment and Advanced Reactors Office of New Reactors Project No. 99902069
 
P.Hastings                            3 ACCEPTANCE FOR REVIEW OF KAIROS POWER LLC, PRINCIPAL DESIGN CRITERIA FOR THE KAIROS POWER FLUORIDE SALT-COOLED, HIGH TEMPERATURE REACTOR TOPICAL REPORT (CAC NO. 000431) - DATED March 06, 2019 DISTRIBUTION:
Public JMonninger KCoyne SMagruder RidsAcrsAcnw_MailCTRResource RidsOgcMailCenterResource RidsNroDsraArpbResource RIdsOpaMailResource ADAMS Accession Number: ML19059A355                            NRO-002 OFFICE     NRO/DSRA                      NRO/DSRA NAME      SMagruder                      JSegala DATE      03/04/2019                    03/06/2019 OFFICIAL RECORD COPY}}

Latest revision as of 00:47, 20 October 2019

Acceptance for Review of Kairos Power LLC, Principal Design Criteria for the Kairos Power Fluoride Salt-Cooled, High Temperature Reactor Topical Report (CAC No. 000431)
ML19059A355
Person / Time
Site: 99902069
Issue date: 03/06/2019
From: John Segala
NRC/NRO/DSRA/ARPB
To: Hastings P
Kairos Power
Magruder S, NRO/DSRA/ARPB, 301-348-576
References
CAC 000431
Download: ML19059A355 (3)


Text

March 06, 2019 Mr. Peter Hastings Vice President, Regulatory Affairs and Quality Kairos Power LLC 707 W Tower Ave Alameda, CA 94501

SUBJECT:

ACCEPTANCE FOR REVIEW OF KAIROS POWER LLC, PRINCIPAL DESIGN CRITERIA FOR THE KAIROS POWER FLUORIDE SALT-COOLED, HIGH TEMPERATURE REACTOR TOPICAL REPORT (CAC NO. 000431)

Dear Mr. Hastings:

By letter dated December 21, 2018, Kairos Power LLC (Kairos) submitted for U.S. Nuclear Regulatory Commission (NRC) staff review, Principal Design Criteria for the Kairos Power Fluoride Salt-Cooled, High Temperature Reactor Topical Report, (Agencywide Documents Access and Management System Accession No. ML18355B067). The NRC staff has performed an acceptance review of the Principal Design Criteria for the Kairos Power Fluoride Salt-Cooled, High Temperature Reactor Topical Report, and found that the material presented provides the technical information in sufficient detail to enable the staff to complete a detailed technical review. The NRC staff expects to issue its request for additional information (RAI) by April 30, 2019, and issue its draft safety evaluation by September 30, 2019. A portion of the basis for completion of the evaluation on this schedule is Kairos response to the RAI within 30 days of your receipt. The NRC staff estimates that the review will require approximately 600 staff hours, including project management time.

The Advisory Committee for Reactor Safeguards (ACRS) will be notified of the, Principal Design Criteria for the Kairos Power Fluoride Salt-Cooled, High Temperature Reactor Topical Report, review and may choose to discuss the report at an ACRS meeting. This may result in a delay in issuing the final safety evaluation to Kairos.

The review schedule milestones and estimated review costs were discussed and agreed upon during a meeting between yourself and Stewart Magruder, Senior Project Manager, Advanced Reactor Policy Branch, NRC on February 25, 2019.

Section 170.21 of Title 10 of the Code of Federal Regulations requires that topical reports are subject to fees based on the full cost of the review. You did not request a fee waiver; therefore, NRC staff hours will be billed accordingly.

P. Hastings 2 If you have questions regarding this matter, please contact Stewart Magruder at (301) 348-5766 or Stewart.Magruder@NRC.gov.

Sincerely,

/RA/

John P. Segala, Chief Advanced Reactor and Policy Branch Division of Safety Systems, Risk Assessment and Advanced Reactors Office of New Reactors Project No. 99902069

P.Hastings 3 ACCEPTANCE FOR REVIEW OF KAIROS POWER LLC, PRINCIPAL DESIGN CRITERIA FOR THE KAIROS POWER FLUORIDE SALT-COOLED, HIGH TEMPERATURE REACTOR TOPICAL REPORT (CAC NO. 000431) - DATED March 06, 2019 DISTRIBUTION:

Public JMonninger KCoyne SMagruder RidsAcrsAcnw_MailCTRResource RidsOgcMailCenterResource RidsNroDsraArpbResource RIdsOpaMailResource ADAMS Accession Number: ML19059A355 NRO-002 OFFICE NRO/DSRA NRO/DSRA NAME SMagruder JSegala DATE 03/04/2019 03/06/2019 OFFICIAL RECORD COPY